← All vessels
MANDARIN MOON
MANDARIN MOON is a 1984 freight ship. The Coast Guard has recorded 33 inspections since 1984, most recently in January 2008, along with 34 deficiencies and 6 operational controls.
Records from 1984 to 2008. Most recent: inspection, 24 January 2008.
- Built
- 1984
- Last inspected
- 24 January 2008
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 34 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8309359 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
S6IT
234428
Flag
LIBERIA
—
Maury page id
psix-234428
Inspections, by type
The 33 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it23536 - Regulatory (Subpart C or D), Gross Ton
23536 - Convention (Subpart B), Gross Ton
13340 - Regulatory (Subpart C or D), Net Ton
13340 - Convention (Subpart B), Net Ton
39339 - Dead Weight, Ton
47365 - Displacement, Ton
23536 - Convention (Subpart B), Gross Ton
13340 - Regulatory (Subpart C or D), Net Ton
13340 - Convention (Subpart B), Net Ton
39339 - Dead Weight, Ton
47365 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 33
24 January 2008
MARPOL Annex I Examination · MARPOL Annex V Examination · ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3132937
16 July 2007
Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2996867
8 March 2007
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2884072
2 March 2007
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2880983
24 February 2007
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2877114
23 February 2007
Random ISPS/MTSA/PSC
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2876029
11 October 2006
Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2798367
25 August 2006
ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2759171
7 June 2006
PII Safety Exam · Spot Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2658955
13 August 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2461764
10 August 2005
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2458189
8 August 2005
Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex V Examination · ISPS II Exam · NPV Safety Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2456044
22 November 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2246527
13 August 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2165512
5 August 2004
ISPS II Exam · NPV Safety Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2157400
22 January 2003
Ballast Water Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1734039
6 March 2002
Annual Inspection · Deficiency Check · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 1489943
10 March 2001
Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 287810
18 March 2000
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 189161
18 March 2000
PII Safety Exam
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 275940
18 March 2000
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 754407
14 February 1998
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 412752
3 March 1997
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 687154
19 February 1997
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 400746
23 March 1993
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 357013
29 August 1991
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 345466
6 May 1991
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 343658
4 August 1988
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 324813
21 November 1986
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 312782
21 February 1986
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 437356
10 July 1985
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 302939
2 August 1984
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 297432
26 July 1984
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 298076
Deficiency record · 34
Construction/Loadline › Hull › Hull Plating
Issued 23 February 2007
Resolved
6 inch deep and 3 feet long dent found on port side shell, directly on the frame between Engine Control Room and the E/R Workshop. Also, 3 patches found on the OWS.
Documentation › Safety/Response Plans/Programs › Ballast Water Management Plan
Issued 23 February 2007
Resolved
The Ballast Water Management Plan is separated into two documents with each part being incomplete. Recommend combining both plans into one correct plan.
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 23 February 2007
Resolved
Mixed garbage was found in the food waste. The food waste was contained in blue containers instead of green containers as listed in the garbage plan. Oily rags are being stored in black containers and stored in the steering flat. Black container are not listed in the garage plan and neither is the storage area. Records of garbage and quantities being incinerated have not been document in the
Fire Fighting › Ventilation Systems › Ducts
Issued 23 February 2007
Resolved
Numerous air vents throughout the accommodation spaces and the forward bos'n stores can not be closed properly. There are gaps between the vent openings or they are missing their securing devices making them neither air and/or weathertight. Therefore in the event of a fire, the air vent leading into the space can not be properly isolated from the atmosphere. SOLAS 74 (2004 Amend) Reg. II-2/14.2.
Personnel › Training › Personal Safety/Social Responsibilities
Issued 23 February 2007
Resolved
Several crew members did not know how to perform their functions as prescribed in the posted Duties and Responsibilities muster sheet. They failed the first fire drill because the assigned members did not secure fire boundaries and secure ventilation into the space. The second drill was conducted and they did much better following the assigned duties.
Construction/Loadline › Structures › Door
Issued 23 February 2007
Resolved
The following watertight doors had gaps, which showed natural light when fully closed. Caused by worn gaskets or clamping devices not properly adjusted. 1) A-deck door to main deck 2) Fwd Bos'n entrance doors P/S side 3) Door from steering gear room to main deck 4) emergency escape hatch from E/R
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 23 February 2007
Resolved
Sewage treatment plant is not being maintained as per the manufacturer's requirements.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 23 February 2007
Resolved
Two of the lifejackets stowed in the forward Bos'n store were missing their emergency lights.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 8 August 2005
Resolved
Remove metal security grates from outside stairwells between main deck and embarkation. Grates pose a safety hazard since they impede access to embarkation deck.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 5 August 2004
Resolved
Not working as designed. Control panel not sending alarm.
Fire Fighting › Means of Escape › Doorways
Issued 5 August 2004
Resolved
Locked from outside. Mechanical device located inside doorway provides only way to exit, not functioning properly.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 5 August 2004
Resolved
non-air tight packaging and non-water tight recepticals.
Engineering › Diesel Engine (auxiliary)
Issued 22 January 2003
Resolved
No. 3 generator, No.1 cylinder has a spraying fuel oil leak from the fuel supply line to the injection pump. Make repairs to the satisfaction of class. LEGACY COMPONENT DESC: Injector (fuel injection)
Engineering › Fuel Oil Service System
Issued 22 January 2003
Resolved
The fuel oil drain lines on the No.1, No.2 and No.3 generators are routed to buckets with rubber hoses. Repair to the satisfaction of class. LEGACY COMPONENT DESC: Piping
Pollution Prevention/Response › Prevention Equipment
Issued 22 January 2003
Resolved
The oily water separator re-circulation piping is not routed as originally designed. Reroute re-circulation piping to the satisfaction of class prior to operating the separator in U.S. waters. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Fire Fighting › Fire Hoses › Condition
Issued 6 March 2002
Resolved
While conducting fire drill 3 of 4 hoses were bad with water spraying everywhere.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device Recorder
Issued 6 March 2002
Resolved
The echo depth sounder was not recording.
Lifesaving
Issued 18 March 2000
Resolved
VESSEL STARBOARD LIFE BOAT FALLS WERE NOT OF EQUAL LENGTH, AS PER SOLAS 74 I REG 11(A). CLASS REPORT SHOWING REPAIRS HAVE BEEN MADE IS REQUIRED PRIOR TO DEPARTURE.
Lifesaving
Issued 18 March 2000
Resolved
VESSEL HAD STARBOARD LIFEBOAT RUB RAILS SEPERATING FROM LIFE BOAT, AS PER SOLAS 74 I REG 11(A). CLASS REPORT SHOWING REPAIRS HAVE BEEN MADE IS REQUIRED PRIOR TO DEPARTURE.
Lifesaving
Issued 18 March 2000
Resolved
STARBOARD LIFEBOAT BRAKE DOES NOT STOP LIFEBOAT LOWERING AUTOMATICALLY BY GRAVITY.
Accommodation/Occupational Safety
Issued 18 March 2000
Resolved
VESSEL HAD NO EMERGENCY HANDLES ON THE FREEZER OR REFRIGERATION DOORS IN GALLEY, AS PER I.L.O. 147. CORRECT PRIOR TO NEXT U.S. PORT.
Accommodation/Occupational Safety
Issued 18 March 2000
Resolved
VESSEL WAS MISSING REQUIRED LIFE VEST IN HOSPITAL, AS PER I.L.O. 147. CORRECT PRIOR TO NEXT U.S. PORT.
Navigation
Issued 18 March 2000
Resolved
VESSEL WAS MISSING U.S. TIDAL CURRENT TABLE OR FOREIGN EQUIVALENT. CORRECT PRIOR TO DEPARTURE.
Accommodation/Occupational Safety
Issued 18 March 2000
Resolved
VESSEL HAD NO OPERATING TOLIET IN HOSPITAL SPACE AS PER I.L.O. 147. REPAIR FLUSHING DEVICE PRIOR TO NEXT U.S. PORT.
Navigation
Issued 18 March 2000
Resolved
VESSEL WAS MISSING B/A 1082 OR U.S. EQUIVALENT. CORRECT PRIOR TO DEPARTURE.
Lifesaving
Issued 18 March 2000
Resolved
VESSEL FAILED ABANDON SHIP DRILL AS PER SOLAS 74 III 18.3.4. VESSEL MUST CONDUCT SATISFACTORY DRILL PRIOR TO DEPARTURE.
Fire Fighting
Issued 18 March 2000
Resolved
VESSEL HAD SEVERELY DAMAGED FIRE HOSE ON STARBOARD FORWARD DECK AREA, AS PER SOLAS 74 II 2/21. CORRECT PRIOR TO DEPARTURE.
Lifesaving
Issued 14 February 1998
Resolved
Fully charge emergency radio battery prior to next U.S. port.
Engineering
Issued 14 February 1998
Resolved
Prove proper operation of all closures for oil containment prior to next U.S. port._x001C_ 33 C.F.R. 155
Navigation
Issued 19 February 1997
Resolved
VESSEL WAS MISSING CURRENT CORRECTIONS ON CHARTS 18746, 18749, AND 18751. VESSEL CORRECTED WHILE ONBOARD.
Navigation
Issued 6 May 1991
Resolved
VESSELS N.O.S. CHARTS 18720,18740,18746,18749, & 18751 WERE NOT CORRECTED TO DATE AS REQUIRED BY 33CFR164.33(a)(1)(ii).
Lifesaving
Issued 6 May 1991
Resolved
1 OF THE 4 SELF IGNIGHTING LIGHTS REQUIRED BY SOLAS 74' WAS FOUND TO BE INOPERATIVE.
Navigation
Issued 6 May 1991
Resolved
VESSELS U.S. COAST PILOT VOL 7 25th ed. WAS NOT CORRECTED TO DATE AS REQUIRED BY 33CFR164.33(a)(2)(i).
Navigation
Issued 6 May 1991
Resolved
VESSELS B.A. LIST OF LIGHTS VOL G 1989ed WAS NOT CORRECTED TO DATE AS REQUIRED BY 33CFR164.33(b).
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.