← All vessels
GREEN BETTER
GREEN BETTER is a 1984 freight ship. The Coast Guard has recorded 29 inspections since 1984, most recently in May 2002, along with 33 deficiencies and 1 operational control.
Records from 1984 to 2002. Most recent: inspection, 16 May 2002.
- Built
- 1984
- Last inspected
- 16 May 2002
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 33 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8201935 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3FPZ2
234440
Flag
PANAMA
—
Maury page id
psix-234440
Inspections, by type
The 29 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 24 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it7017 - Regulatory (Subpart C or D), Gross Ton
3371 - Regulatory (Subpart C or D), Net Ton
9687 - Dead Weight, Ton
13275 - Displacement, Ton
3371 - Regulatory (Subpart C or D), Net Ton
9687 - Dead Weight, Ton
13275 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 29
16 May 2002
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1617581
23 August 2001
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1069257
17 July 2001
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 292144
12 May 2001
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 289907
18 May 2000
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 277961
6 April 2000
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 276617
24 February 2000
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 275074
3 February 2000
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 274309
27 July 1999
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 711744
22 July 1999
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 58355
24 February 1999
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 425857
30 December 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 424205
17 May 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 416225
24 June 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 405111
13 June 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 404683
22 February 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 400791
20 August 1996
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 394451
6 August 1996
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 393954
11 June 1996
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 391970
16 December 1995
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 386060
4 June 1995
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 379156
16 March 1988
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 522763
1 July 1987
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 317633
20 May 1987
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 316449
14 October 1986
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 472338
17 May 1986
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 309123
4 March 1986
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 540616
2 May 1985
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 301784
10 August 1984
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 297436
Deficiency record · 33
Unknown
Issued 17 July 2001
Resolved
Vessel to remove all piping associated with old OWS system. New OWS and piping is installed.
Documentation
Issued 12 May 2001
Resolved
Have class correct Safety Radio Certificate to reflect that ship has duplication of equipment for GMDSS.
Engineering
Issued 12 May 2001
Resolved
Update OTP to include lube oil and new bilge water/OWS pipe layout.
Documentation
Issued 12 May 2001
Resolved
Update SOPEP to reflect new name and current operator [name withheld] approval in behalf of Flag.
Engineering
Issued 6 April 2000
Resolved
Demonstrate proper operation of OWS for USCG inspector. Insure proper maintenance and operating procedures are established and understood by engineering crew.
Engineering
Issued 6 April 2000
Resolved
Provide class society report attesting to the proper operation of the oily water separator to insure unit is cleaning and discharging water meeting the 15 ppm standard.
Fire Fighting
Issued 3 February 2000
Resolved
Prior to February 10, 2000, repair the exhaust leak in way of the emergencyfire pump's diesel engine.
Fire Fighting
Issued 3 February 2000
Resolved
Prior to March 3, 2000, provide on board firehose nozzles incorporating a shut-off and dual purpose (spray/jet).
Accommodation/Occupational Safety
Issued 3 February 2000
Resolved
Prior to using the vessel's Type II MSD in U.S. waters, provide on board a supply of chlorine tablets.
Navigation
Issued 3 February 2000
Resolved
Prove the proper operation of the steering system loss of power alarm bell on the navigation bridge. SOLAS 74, II-1/29
Engineering
Issued 3 February 2000
Resolved
Prior to returning to U.S. waters, provide documentation from ABS attestingto the proper operation of the oily water separator. Reference ABS survey report FL2112 dated February 3, 2000.
Documentation
Issued 30 December 1998
Resolved
UPDATE SOLAS TRAINING MANUAL AS TO REFLECT ALL REQUIRED ENTRIES/EQUIPMENT USE AS OUTLINED IN SOLAS.
Navigation
Issued 30 December 1998
Resolved
PROVIDE EMERGENCY STEERING INSTRUCTIONS AND PROPERLY POST THEM AT STEERING COMPARTMENT. 33 CFR.
Lifesaving
Issued 30 December 1998
Resolved
REPLACE/RENEW/SERVICE 02 HYDROSTATIC RELEASE UNITS FOR PORT AND STARBOARD LIFERAFTS OR PROVIDE EVIDENCE OF SERVICING WITH IN THE LAST YEAR. SOLAS 3 REGULATION 51/53.
Lifesaving
Issued 17 May 1998
Resolved
DISPOSE OF PROPERLY OLD BATTERIES IN BATTERY ROOM. CORRECT PRIOR TO 3JUNE98.
Lifesaving
Issued 17 May 1998
Resolved
INSTALL ELECTRICAL MATING IN FRONT OF CONTROL PANEL IN MARINE SANITATION DEVICE ROOM. CORRECT PRIOR TO 13 JUNE 1998.
Fire Fighting
Issued 17 May 1998
Resolved
REPAIR PIN HOLE IN COOLING LINE TO EMERGENCY FIRE PUMP. CORRECT PRIOR TO 13JUNE 1998.
Fire Fighting
Issued 13 June 1997
Resolved
PROVIDE PROPER BRACKETS TO FIRE EXTINGUISHER IN SEWAGE TREATMENT PLANT ROOMAND PAINT LOCKER.
Electrical
Issued 13 June 1997
Resolved
PROVIDE LIGHT FIXTURE WITH PROTECTIVE COVER LOCATED IN GREASE LOCKER.
Electrical
Issued 13 June 1997
Resolved
PROVIDE LIGHT FIXTURES WITH PROTECTIVE COVERS IN FUEL PURIFIER ROOM AND PAINT LOCKER.
Lifesaving
Issued 22 February 1997
Resolved
RENEW OUTDATED LINE THROWING GUN APPLIANCE. LINES WERE MANUFACTURED ON ON FEB 84.
Construction/Loadline
Issued 22 February 1997
Resolved
PAINT LOADLINE IN CONTRASTING COLOR. ILLC
Electrical
Issued 6 August 1996
Resolved
ENGINE ROOM PORT SIDE-UPPER DECK EMERGENCY LIGHT HOUSING WASTED.
Accommodation/Occupational Safety
Issued 6 August 1996
Resolved
ENGINE ROOM PORT SIDE-UPPER DECK FWD EXIT BLOCKED WITH NO MEANS OF_x001C_ OPENING. VESSEL CORRECTED DEFICIENCY AT NEXT PORT CALL TO SAN JUAN.
Navigation
Issued 6 August 1996
Resolved
STEERING ROOM SYSTEM CONTAIMENT HAS EXCESSIVE HYDRAULIC FLUID IN IT. VESSEL CORRECTED DEFICIENCY ON THEIR NEXT PORT CALL TO SAN JUAN.
Engineering
Issued 11 June 1996
Resolved
RENEW PACKING ON MAIN SALT WATER COOLING PUMP, PORT SIDE FORWARD IN ENGINE ROOM.(CORRECT TO THE SATISFACTION OF CLASS). SOLAS 74 AMMENDED CHAPTER II-1REG. 26, 3-6.
Deck/Cargo
Issued 11 June 1996
Resolved
REPAIR & RENEW BUNKER STATION & BUNKER VENT CONTAINMENT. ALSO PROVIDE DRAINPLUG AND RENEW VALVE HANDLE AT STARBOARD BUNKER CUTOFF VALVE. (CORRECT TO THE SATISFACTION OF CLASS). 33 CFR 155-320 (a) (2).
Electrical
Issued 11 June 1996
Resolved
REINSTALL ELECTRICAL SYSTEM TO POTABLE WATER PUMPS SO AS TO REMOVE ELECTRICAL HAZARD OF EXPOSED WIRING.(CORRECT TO THE SATISFACTION OF CLASS).ILO 147.
Accommodation/Occupational Safety
Issued 11 June 1996
Resolved
REPAIR HANDRAIL BRACKET ON STAIR TOWER THAT LEADS TO SEWAGE ROOM. (CORRECT TO THE SATISFACTION OF CLASS). ILO 147.
Lifesaving
Issued 11 June 1996
Resolved
BOTH LIFEBOATS MISSING RADAR REFLECTORS. (SOLAS 74 AMMENDED CHAPTER III REG. 11) PROVIDE BY COMPLIANCE DATE.
Documentation
Issued 11 June 1996
Resolved
PROVIDE FORM E OF THE SAFETY EQUIPMENT CERTIFICATE. (SOLAS 74 AMMENDED CH. 1 REG. 12) PROVIDE BY COMPLIANCE DATE.
Navigation
Issued 11 June 1996
Resolved
REPAIR OIL LEAK ON #2 STEERING GEAR PUMP, OUT BOARD SIDE, JUST AFT OF SIGHTGLASS. (CORRECT TO THE SATISFACTION OF CLASS). SOLAS 74 AMMENDED CHAPTER II-1 REG. 29-1
Navigation
Issued 11 June 1996
Resolved
INSTALL VALVE HANDLES ON A,B,C & D VALVES ON STEERING GEAR & STENCIL VALVESA,B,C, & D. (CORRECT TO THE SATISFACTION OF CLASS) SOLAS 74 AMMENDED CHAPTER II-1 REG. 29-1
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.