Records from 1986 to 1992. Most recent: inspection, 28 April 1992.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Lifesaving
Issued 6 May 1990
Resolved
REPLACE OUTDATED SHOULDER LINE THROWING GUN CARDRIGES.
Condition: Unknown
Due 15 June 1990
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 6 May 1990
Resolved
REPLACE THREE 1 1/2" 50' FIRE HOSES ON MAIN DECK THAT ARE LEAKING WITH NEW UL APPROVED HOSES.
Condition: Unknown
Due 6 May 1990
Resolved 6 May 1990
Engineering
Issued 6 May 1990
Resolved
OBTAIN AND INSTALL ON BOTH SHIPS SERVICE AIR RECEIVERS NEW ASME SAFETY VALVES NOT TO EXCEED 250 PSI SET PRESSURE AND OF ADEQUATE RELIEF CAPACITY.
Condition: Unknown
Due 6 May 1990
Resolved 6 May 1990
Accommodation/Occupational Safety
Issued 6 May 1990
Resolved
MAKE OPERABLE MAIN DECK VENTLATION EMERGENCY SHUT DOWN.
Condition: Unknown
Due 6 May 1990
Resolved 6 May 1990
Navigation
Issued 6 May 1990
Resolved
PROVIDE ONBOARD CURRENT 46 CFR SUBCHAPTERS F & I AND 33 CFR.
Condition: Unknown
Due 6 May 1990
Resolved 6 May 1990
Documentation
Issued 31 July 1989
Resolved
PROVIDE TO [name withheld] AN UPDATED CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 31 July 1989
Resolved 31 July 1989
Documentation
Issued 31 July 1989
Resolved
PROVIDE TO [name withheld] A COPY OF UPDATED ANNUAL LOAD LINE CERTIFICATE.
Condition: Unknown
Due 31 July 1989
Resolved 31 July 1989
Electrical
Issued 31 July 1989
Resolved
REMOVE AND PROPERLY CONNECT ELECTRICAL WIRING TO ELECTRICAL PANEL AT ENTRANCE TO E/R PASSAGEWAY AND INSTALL COVER AND PANEL BOARD TO SAME.
Condition: Unknown
Due 31 July 1989
Resolved 31 July 1989
Construction/Loadline
Issued 31 July 1989
Resolved
INSTALL CLOSURE AND OPENING HANDLES ON ALL BILGE AND BALLAST LINES IN AFTERSTEERING COMPARTMENT.
Condition: Unknown
Due 31 July 1989
Resolved 31 July 1989
Engineering
Issued 31 July 1989
Resolved
FIX ENGINE ROOM AUDIBLE ALARMS.
Condition: Unknown
Due 31 July 1989
Resolved 31 July 1989
Electrical
Issued 31 July 1989
Resolved
REPAIR OR REPLACE PORT GENERATOR TACOMETER AND PROVE PROPER OPERATION OF OVERSPEED OF SAME.
Condition: Unknown
Due 31 July 1989
Resolved 31 July 1989
Fire Fighting
Issued 1 May 1988
Resolved
PROVIDE STORAGE RACK FOR ALL SCBA CYLINDERS.
Condition: Unknown
Due 1 May 1988
Resolved 1 May 1988
Fire Fighting
Issued 1 May 1988
Resolved
HYDRO STATICALLY TEST ALL SPARE SCBA CYLINDERS THAT HAVE NOT BEEN TESTED INLAST 5 YEARS.
Condition: Unknown
Due 1 May 1988
Resolved 1 May 1988
Fire Fighting
Issued 1 May 1988
Resolved
INSTALL CG APPROVED 15 LB CO2 CYLINDER FOR FIXED CO2 SYSTEM IN PAINT LOCKER
Condition: Unknown
Due 1 May 1988
Resolved 1 May 1988
Navigation
Issued 1 May 1988
Resolved
INSTALL AFT ANCHOR LIGHT AT LEAST 4.5 METERS LOWER THAN FWD ANCHOR LIGHT.
Condition: Unknown
Due 1 May 1988
Resolved 1 May 1988
Engineering
Issued 1 May 1988
Resolved
INSTALL REACH RODS FOR ALL F.O. TANK SUCTIONS AND DAY TANK FEEDER TO ENGINES. REACH RODS ARE TO BE OPERABLE FROM MAIN DECK.
Condition: Unknown
Due 1 May 1988
Resolved 1 May 1988
Navigation
Issued 1 May 1988
Resolved
REPOSITION NOT-UNDER-COMMAND AND RESTRICTED INABILITY TO MANEUVER LIGHTS SOTHAT THE HORIZONTAL SECTOR IS NOT OBSTRUCTED MORE THAN 6 DEGREES IN ACCORDANCE WITH COLREGS ANNEX I SEC. 9(B).
Condition: Unknown
Due 1 May 1988
Resolved 1 May 1988
Engineering
Issued 1 May 1988
Resolved
PROVIDE FLAME SHIELD FOR FUEL FILTERS ON BOTH GENERATORS.
Condition: Unknown
Due 1 May 1988
Resolved 1 May 1988
Engineering
Issued 1 May 1988
Resolved
PROVIDE AND PROVE PROPER OPERATION OF ASME RELIEF VALVES FOR BOTH AIR RECEIVERS. NAME PLATE DATE SHALL INDICATE FACTORY SET PRESSURE AND ADJUST- MENT SHALL NOT EXCEED 10% UP OR DOWN FOR RELIEF VALVES MARKED 250 PSI AND BELOW AND 5% FOR VALVES MARKED OVER 250 PSI.
Condition: Unknown
Due 1 May 1988
Resolved 1 May 1988
Deck/Cargo
Issued 1 May 1988
Resolved
PROVIDE PROPER 30X30 MESH/INCH FLAME SCREENS FOR FOLLOWING VENTS: NO.1 P&S FUEL OIL, NO.3&4 PORT F.O. VENT, LUBE OIL VENT PORT & STBD AND HYDRAULIC OIL VENT STBD.
Condition: Unknown
Due 1 May 1988
Resolved 1 May 1988
Lifesaving
Issued 1 May 1988
Resolved
LABEL GENERAL ALARM BELL IN FORWARD TUNNEL.
Condition: Unknown
Due 1 May 1988
Resolved 1 May 1988
Fire Fighting
Issued 5 June 1986
Resolved
DRILL A VENT HOLE OF AT LEAST 1 1/2" DIAMETER IN THE PAINT LOCKER WEATHER DECK BHD,NEAR THE TOP AND AS FAR AWAY AS PRACTICABLE FROM THE CO2 DISCHARGENOZZLE TO RELIEVE EXCESS PRESSURE THAT MAY ACCUMULATE IN THE SPACE WHEN THECO2 IS DISCHARGED.(46 CFR 95.15-40 A)INSTALL FLAME SCREEN OF 20X20 OR 30X30
Condition: Unknown
Due 5 June 1986
Resolved 5 June 1986
Fire Fighting
Issued 5 June 1986
Resolved
PROVIDE EITHER A FLAME SAFETY LAMP OR A COMBINED OXYGEN/EXPLOSIVE METER, FM CSA, OR UL APPROVED FOR CLASS 1, DIV. 1, SPACES AND GROUP B,C,D, AND E GASES FOR THE OTHER FIREMAN'S OUTFIT.
Condition: Unknown
Due 5 June 1986
Resolved 5 June 1986
Engineering
Issued 5 June 1986
Resolved
HYDRO THE TWO ENGINE ROOM(250 PSI MAWP)AIR RECEIVERS TO 1.25XMAWP,PRIOR TO PERORMING THIS HYDROSTATIC TEST,THE AIR RECEIVERS SHALL HAVE INSTALLED(IN THEIR TOP SIDE SHELLS),A NIPPLE WITH A VALVE(TO VENT OFF AIR)WHICH SHALL BEWELDED IN PLACE IN ACCORDANCE WITH AN APPROVED(USCG)WELDING PROCEDURE.
Condition: Unknown
Due 5 June 1986
Resolved 5 June 1986
Fire Fighting
Issued 5 June 1986
Resolved
PROVIDE A LOW VELOCITY 4 FT FOG APPLICATOR MEETING THE REQUIREMENTS OF 46 CFR 162.027 AS REQUIRED BY 46 CFR 95.10-10(1)(2)(1-1) FOR THE ENGINE ROOM.
Condition: Unknown
Due 5 June 1986
Resolved 5 June 1986
Accommodation/Occupational Safety
Issued 5 June 1986
Resolved
RE-INSTALL THE RELIEF VALVE IN THE SANITARY HEAD TANK SO THERE IS NOT A VALVE BETWEEN IT AND THE TANK IT SERVES.
Condition: Unknown
Due 5 June 1986
Resolved 5 June 1986
Engineering
Issued 5 June 1986
Resolved
SEVICE OR RENEW THE E/R AIR RECEIVERS' RELIEF VALVES SUCH THAT THEY WILL POP AT OR BELOW 250 PSI.THE NAMEPLATE DATA SHALL STIPULATE ITS FACTORY SET PRESSURE.AND ADJUSTMENT UP OR DOWN SHALL BE NO GREATER THAN 10% OF FACTORY SET PRESSURE.IF THE VALVES ARE RENEWED,THEY SHALL HAVE HAND LIFT DEVICES.
Condition: Unknown
Due 5 June 1986
Resolved 5 June 1986
Lifesaving
Issued 5 June 1986
Resolved
REPLACE TWO (2) RING BUOYS WITH APPROVED MODELS MEETING THE REQUIREMENTS OF46 CFR 93.43.
Condition: Unknown
Due 5 June 1986
Resolved 5 June 1986
Electrical
Issued 5 June 1986
Resolved
REPLACE THE ELECTRICAL FIXTURES IN THE PAINT LOCKER(ON DECK) WITH ONES WHICH ARE RATED BY EITHER FM, UL, OR CSA AS EXPLOSION-PROOF FOR CLASS 1, DIV 1, SPACES AND GOOD FOR GROUPS B,C,D, AND E GASES.
Condition: Unknown
Due 5 June 1986
Resolved 5 June 1986
Electrical
Issued 5 June 1986
Resolved
RENEW THE BROKEN STARBOARD GENERATOR TACHOMETER.
Condition: Unknown
Due 5 June 1986
Resolved 5 June 1986
Engineering
Issued 5 June 1986
Resolved
INSTALL EITHER ONE LARGE SPLASH GUARD OR INDIVIDUAL ONES AROUND EACH FLANGED/MECHANICALLY COUPLED FUEL OIL PIPING UNIONS IN WAY OF THE PORT MAINDIESEL'S FORWARD CORNER AND THE FUEL OIL TRANSFER PIPING.
Condition: Unknown
Due 5 June 1986
Resolved 5 June 1986
Lifesaving
Issued 5 June 1986
Resolved
HAVE ALL FOUR(4) LIFERAFTS SERVICED AT AN APPROVED (USCG) LIFERAFT SERVICING FACILITY IN THE PRESENCE OF A USCG MARINE INSPECTOR.
Condition: Unknown
Due 5 June 1986
Resolved 5 June 1986
Fire Fighting
Issued 5 June 1986
Resolved
PROVIDE ONE FIREMAN'S OUTFIT MEETING THE REQUIREMENTS OF CFR 96.35-10. THE PROTECTIVE CLOTHING SHALL BE A "TRUE" FIREMAN'S OUTFIT. THE FLAME SAFETY LAMP MAY BE REPLACED WITH AN EXPLOSIVE/OXYGEN METER COMBINATION RATED EX- PLOSION-PROOF CLASS 1, DIV. 1, GROUP B,C,D,E GASES BY EITHER UL,FM, OR CSA.
Condition: Unknown
Due 5 June 1986
Resolved 5 June 1986
Lifesaving
Issued 5 June 1986
Resolved
PROVIDE 20 WHISTLES MEETING THE REQUIREMENTS OF 46 CFR 94.42-5 TO REPLACE THE SOLAS APPROVED WHISTLES.
Condition: Unknown
Due 5 June 1986
Resolved 5 June 1986