TADRIB EXPRESS is a 1984 offshore supply vessel. The Coast Guard has recorded 10 inspections since 1986, most recently in April 1992, along with 34 deficiencies.

Records from 1986 to 1992. Most recent: inspection, 28 April 1992.

Built
1984
Last inspected
28 April 1992
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8215089 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WSS6904
234482
Flag
UNITED STATES
—
Maury page id
psix-234482

Inspections, by type

Years with a record 7 calendar years (1986–1992)
The 10 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 34 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it961 - Convention (Subpart B), Gross Ton
299 - Regulatory (Subpart C or D), Gross Ton
288 - Convention (Subpart B), Net Ton
203 - Regulatory (Subpart C or D), Net Ton
1365 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 10

28 April 1992 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 951665
20 March 1991 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 902805
18 January 1991 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 939964
17 May 1990 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1243340
6 May 1990 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1222300
31 July 1989 Hull Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1221434
30 August 1988 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1347231
1 May 1988 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1346691
17 March 1987 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1324884
5 June 1986 Credit Drydock · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1309172

Deficiency record · 34

Lifesaving
Issued 6 May 1990 Resolved
REPLACE OUTDATED SHOULDER LINE THROWING GUN CARDRIGES.
Condition: Unknown
Due 15 June 1990
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 6 May 1990 Resolved
REPLACE THREE 1 1/2" 50' FIRE HOSES ON MAIN DECK THAT ARE LEAKING WITH NEW UL APPROVED HOSES.
Condition: Unknown
Due 6 May 1990
Resolved 6 May 1990
Engineering
Issued 6 May 1990 Resolved
OBTAIN AND INSTALL ON BOTH SHIPS SERVICE AIR RECEIVERS NEW ASME SAFETY VALVES NOT TO EXCEED 250 PSI SET PRESSURE AND OF ADEQUATE RELIEF CAPACITY.
Condition: Unknown
Due 6 May 1990
Resolved 6 May 1990
Accommodation/Occupational Safety
Issued 6 May 1990 Resolved
MAKE OPERABLE MAIN DECK VENTLATION EMERGENCY SHUT DOWN.
Condition: Unknown
Due 6 May 1990
Resolved 6 May 1990
Navigation
Issued 6 May 1990 Resolved
PROVIDE ONBOARD CURRENT 46 CFR SUBCHAPTERS F & I AND 33 CFR.
Condition: Unknown
Due 6 May 1990
Resolved 6 May 1990
Documentation
Issued 31 July 1989 Resolved
PROVIDE TO [name withheld] AN UPDATED CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 31 July 1989
Resolved 31 July 1989
Documentation
Issued 31 July 1989 Resolved
PROVIDE TO [name withheld] A COPY OF UPDATED ANNUAL LOAD LINE CERTIFICATE.
Condition: Unknown
Due 31 July 1989
Resolved 31 July 1989
Electrical
Issued 31 July 1989 Resolved
REMOVE AND PROPERLY CONNECT ELECTRICAL WIRING TO ELECTRICAL PANEL AT ENTRANCE TO E/R PASSAGEWAY AND INSTALL COVER AND PANEL BOARD TO SAME.
Condition: Unknown
Due 31 July 1989
Resolved 31 July 1989
Construction/Loadline
Issued 31 July 1989 Resolved
INSTALL CLOSURE AND OPENING HANDLES ON ALL BILGE AND BALLAST LINES IN AFTERSTEERING COMPARTMENT.
Condition: Unknown
Due 31 July 1989
Resolved 31 July 1989
Engineering
Issued 31 July 1989 Resolved
FIX ENGINE ROOM AUDIBLE ALARMS.
Condition: Unknown
Due 31 July 1989
Resolved 31 July 1989
Electrical
Issued 31 July 1989 Resolved
REPAIR OR REPLACE PORT GENERATOR TACOMETER AND PROVE PROPER OPERATION OF OVERSPEED OF SAME.
Condition: Unknown
Due 31 July 1989
Resolved 31 July 1989
Fire Fighting
Issued 1 May 1988 Resolved
PROVIDE STORAGE RACK FOR ALL SCBA CYLINDERS.
Condition: Unknown
Due 1 May 1988
Resolved 1 May 1988
Fire Fighting
Issued 1 May 1988 Resolved
HYDRO STATICALLY TEST ALL SPARE SCBA CYLINDERS THAT HAVE NOT BEEN TESTED INLAST 5 YEARS.
Condition: Unknown
Due 1 May 1988
Resolved 1 May 1988
Fire Fighting
Issued 1 May 1988 Resolved
INSTALL CG APPROVED 15 LB CO2 CYLINDER FOR FIXED CO2 SYSTEM IN PAINT LOCKER
Condition: Unknown
Due 1 May 1988
Resolved 1 May 1988
Navigation
Issued 1 May 1988 Resolved
INSTALL AFT ANCHOR LIGHT AT LEAST 4.5 METERS LOWER THAN FWD ANCHOR LIGHT.
Condition: Unknown
Due 1 May 1988
Resolved 1 May 1988
Engineering
Issued 1 May 1988 Resolved
INSTALL REACH RODS FOR ALL F.O. TANK SUCTIONS AND DAY TANK FEEDER TO ENGINES. REACH RODS ARE TO BE OPERABLE FROM MAIN DECK.
Condition: Unknown
Due 1 May 1988
Resolved 1 May 1988
Navigation
Issued 1 May 1988 Resolved
REPOSITION NOT-UNDER-COMMAND AND RESTRICTED INABILITY TO MANEUVER LIGHTS SOTHAT THE HORIZONTAL SECTOR IS NOT OBSTRUCTED MORE THAN 6 DEGREES IN ACCORDANCE WITH COLREGS ANNEX I SEC. 9(B).
Condition: Unknown
Due 1 May 1988
Resolved 1 May 1988
Engineering
Issued 1 May 1988 Resolved
PROVIDE FLAME SHIELD FOR FUEL FILTERS ON BOTH GENERATORS.
Condition: Unknown
Due 1 May 1988
Resolved 1 May 1988
Engineering
Issued 1 May 1988 Resolved
PROVIDE AND PROVE PROPER OPERATION OF ASME RELIEF VALVES FOR BOTH AIR RECEIVERS. NAME PLATE DATE SHALL INDICATE FACTORY SET PRESSURE AND ADJUST- MENT SHALL NOT EXCEED 10% UP OR DOWN FOR RELIEF VALVES MARKED 250 PSI AND BELOW AND 5% FOR VALVES MARKED OVER 250 PSI.
Condition: Unknown
Due 1 May 1988
Resolved 1 May 1988
Deck/Cargo
Issued 1 May 1988 Resolved
PROVIDE PROPER 30X30 MESH/INCH FLAME SCREENS FOR FOLLOWING VENTS: NO.1 P&S FUEL OIL, NO.3&4 PORT F.O. VENT, LUBE OIL VENT PORT & STBD AND HYDRAULIC OIL VENT STBD.
Condition: Unknown
Due 1 May 1988
Resolved 1 May 1988
Lifesaving
Issued 1 May 1988 Resolved
LABEL GENERAL ALARM BELL IN FORWARD TUNNEL.
Condition: Unknown
Due 1 May 1988
Resolved 1 May 1988
Fire Fighting
Issued 5 June 1986 Resolved
DRILL A VENT HOLE OF AT LEAST 1 1/2" DIAMETER IN THE PAINT LOCKER WEATHER DECK BHD,NEAR THE TOP AND AS FAR AWAY AS PRACTICABLE FROM THE CO2 DISCHARGENOZZLE TO RELIEVE EXCESS PRESSURE THAT MAY ACCUMULATE IN THE SPACE WHEN THECO2 IS DISCHARGED.(46 CFR 95.15-40 A)INSTALL FLAME SCREEN OF 20X20 OR 30X30
Condition: Unknown
Due 5 June 1986
Resolved 5 June 1986
Fire Fighting
Issued 5 June 1986 Resolved
PROVIDE EITHER A FLAME SAFETY LAMP OR A COMBINED OXYGEN/EXPLOSIVE METER, FM CSA, OR UL APPROVED FOR CLASS 1, DIV. 1, SPACES AND GROUP B,C,D, AND E GASES FOR THE OTHER FIREMAN'S OUTFIT.
Condition: Unknown
Due 5 June 1986
Resolved 5 June 1986
Engineering
Issued 5 June 1986 Resolved
HYDRO THE TWO ENGINE ROOM(250 PSI MAWP)AIR RECEIVERS TO 1.25XMAWP,PRIOR TO PERORMING THIS HYDROSTATIC TEST,THE AIR RECEIVERS SHALL HAVE INSTALLED(IN THEIR TOP SIDE SHELLS),A NIPPLE WITH A VALVE(TO VENT OFF AIR)WHICH SHALL BEWELDED IN PLACE IN ACCORDANCE WITH AN APPROVED(USCG)WELDING PROCEDURE.
Condition: Unknown
Due 5 June 1986
Resolved 5 June 1986
Fire Fighting
Issued 5 June 1986 Resolved
PROVIDE A LOW VELOCITY 4 FT FOG APPLICATOR MEETING THE REQUIREMENTS OF 46 CFR 162.027 AS REQUIRED BY 46 CFR 95.10-10(1)(2)(1-1) FOR THE ENGINE ROOM.
Condition: Unknown
Due 5 June 1986
Resolved 5 June 1986
Accommodation/Occupational Safety
Issued 5 June 1986 Resolved
RE-INSTALL THE RELIEF VALVE IN THE SANITARY HEAD TANK SO THERE IS NOT A VALVE BETWEEN IT AND THE TANK IT SERVES.
Condition: Unknown
Due 5 June 1986
Resolved 5 June 1986
Engineering
Issued 5 June 1986 Resolved
SEVICE OR RENEW THE E/R AIR RECEIVERS' RELIEF VALVES SUCH THAT THEY WILL POP AT OR BELOW 250 PSI.THE NAMEPLATE DATA SHALL STIPULATE ITS FACTORY SET PRESSURE.AND ADJUSTMENT UP OR DOWN SHALL BE NO GREATER THAN 10% OF FACTORY SET PRESSURE.IF THE VALVES ARE RENEWED,THEY SHALL HAVE HAND LIFT DEVICES.
Condition: Unknown
Due 5 June 1986
Resolved 5 June 1986
Lifesaving
Issued 5 June 1986 Resolved
REPLACE TWO (2) RING BUOYS WITH APPROVED MODELS MEETING THE REQUIREMENTS OF46 CFR 93.43.
Condition: Unknown
Due 5 June 1986
Resolved 5 June 1986
Electrical
Issued 5 June 1986 Resolved
REPLACE THE ELECTRICAL FIXTURES IN THE PAINT LOCKER(ON DECK) WITH ONES WHICH ARE RATED BY EITHER FM, UL, OR CSA AS EXPLOSION-PROOF FOR CLASS 1, DIV 1, SPACES AND GOOD FOR GROUPS B,C,D, AND E GASES.
Condition: Unknown
Due 5 June 1986
Resolved 5 June 1986
Electrical
Issued 5 June 1986 Resolved
RENEW THE BROKEN STARBOARD GENERATOR TACHOMETER.
Condition: Unknown
Due 5 June 1986
Resolved 5 June 1986
Engineering
Issued 5 June 1986 Resolved
INSTALL EITHER ONE LARGE SPLASH GUARD OR INDIVIDUAL ONES AROUND EACH FLANGED/MECHANICALLY COUPLED FUEL OIL PIPING UNIONS IN WAY OF THE PORT MAINDIESEL'S FORWARD CORNER AND THE FUEL OIL TRANSFER PIPING.
Condition: Unknown
Due 5 June 1986
Resolved 5 June 1986
Lifesaving
Issued 5 June 1986 Resolved
HAVE ALL FOUR(4) LIFERAFTS SERVICED AT AN APPROVED (USCG) LIFERAFT SERVICING FACILITY IN THE PRESENCE OF A USCG MARINE INSPECTOR.
Condition: Unknown
Due 5 June 1986
Resolved 5 June 1986
Fire Fighting
Issued 5 June 1986 Resolved
PROVIDE ONE FIREMAN'S OUTFIT MEETING THE REQUIREMENTS OF CFR 96.35-10. THE PROTECTIVE CLOTHING SHALL BE A "TRUE" FIREMAN'S OUTFIT. THE FLAME SAFETY LAMP MAY BE REPLACED WITH AN EXPLOSIVE/OXYGEN METER COMBINATION RATED EX- PLOSION-PROOF CLASS 1, DIV. 1, GROUP B,C,D,E GASES BY EITHER UL,FM, OR CSA.
Condition: Unknown
Due 5 June 1986
Resolved 5 June 1986
Lifesaving
Issued 5 June 1986 Resolved
PROVIDE 20 WHISTLES MEETING THE REQUIREMENTS OF 46 CFR 94.42-5 TO REPLACE THE SOLAS APPROVED WHISTLES.
Condition: Unknown
Due 5 June 1986
Resolved 5 June 1986