Records from 2005 to 2026. Most recent: inspection, 31 January 2026.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 9 May 2025
Resolved
The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. If any of the equipment or records have not been properly maintained, a qualified servicing facility must perform the required inspections, maintenance procedures, and hydrostatic pressure tests. A tag issued by a qualified servicing organization, and attached to each extinguisher, may be accepted as evidence that the necessary maintenance procedures have been conducted.
Fixed CO2 system and fire extinguishers are due for annual inspection.
46 CFR 176.810
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2025
Resolution: Resolved
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 May 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to:(a) Provide services necessary for safety under normal and emergency conditions;(b) Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock;(c) Minimize accidental personnel contact with energized parts; Multiple wires under helm need to be properly dead ended. PA panel has an open space that needs to be filled.
46 CFR 183.200
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 May 2025
Resolution: RESOLVED
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 26 August 2024
Resolved
Training and drills (1) Every crewmember with emergency duties assigned on the muster list must be familiar with their assigned duties before the voyage begins. Vessel's crew was not on board to conduct drills. Provide visual evidence of drills prior to loading passengers.
46 cfr 199.180b1
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 August 2024
Resolution: Received video evidence of regular crew conducting drills.
09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 26 August 2024
Resolved
Stowage and care of cylinders. (1) Cylinders must always be secured and, when not in use, they must be stowed in a rack in an upright position, with the valve protection cap in place. Oxygen tanks must be secured in a non-electrical space.
46 cfr 147.60b1
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 September 2024
Resolution: Oxygen tanks were properly secured.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 August 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to (b) Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. The junction box on the port blower, fwd of the main engine, above gen set needs a cover, power lugs need to be installed above the port gen set and battery panel, the electric panel in the port aft bulkhead has a reset pulley that is not readily available.
46 cfr 183.200b
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 September 2024
Resolution: All items listed were properly rectified.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 26 August 2024
Resolved
An exposed hazard such as gears or rotating machinery, must be properly protected by a cover, guard or rail. Install a guard at the rotating shaft on the port main.
46 cfr 177.960
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 September 2024
Resolution: Guard was properly installed.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 26 August 2024
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. Stairwell railing on the second deck is loose and needs to be tightened. Refrigerator needs to be secured to the vessel.
46 cfr 177.100
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 September 2024
Resolution: Hand rail was properly mounted and refridgerator was properly secured.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 August 2024
Resolved
Each fixed power bilge pump must be self priming. It may be driven off the main engine or other source of power. It must be permanently connected to the bilge manifold and may also be connected to the fire main. If of sufficient capacity, a power bilge pump may also serve
as a fire pump. Bilge crossover is inoperable from both port and stbd side. Port side bilge has no suction.
46 cfr 182.520c
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 August 2024
Resolution: Resolved
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 August 2024
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from fire or machinery failure. Stbd fire pump has a small leak and was unable to attain 60 psi when tested.
46 cfr 182.100
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 August 2024
Resolution: Resolved
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 21 August 2024
Resolved
Fixed gas fire extinguishing systems. A storage cylinder must be securely fastened, supported, and protected against damage. The CO2 storage tank on the
port side has a damaged bracket.
46cfr 181.410c4
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 August 2024
Resolution: Resolved
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 August 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to: (b) Protect passengers, crew, other persons and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Junction box cover not installed in the MSD space.
46 cfr 183.200b
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 August 2024
Resolution: Resolved
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 21 August 2024
Resolved
An exposed hazard such as gears or rotating machinery, must be properly protected by a cover, guard or rail.Port side fire pump is missing a guard around the shaft. Stbd side main engine belt is missing a guard. Provide cover or guard as required to the satisfaction of the attending Marine Inspector.
46 cfr 177.960
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 August 2024
Resolution: Resolved
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 21 August 2024
Resolved
System design and installation must be in accordance with the Marine Design, Installation, Operation, and Maintenance Manual approved for the system by the Commandant. Charge indicator valve on the stbd CO2 system is indicating system is pressurized.
46 cfr 181.410 a 3
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 August 2024
Resolution: Resolved
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 21 August 2024
Resolved
Each battery must be located as high above the bilge as practicable, secured to protect against shifting with the roll and pitch of the vessel, and free from exposure to water splash or spray. Secure both port and stbd engine room battery banks to prevent shifting. Ensure
straps are securing battery covers.
46 cfr 183.350
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 August 2024
Resolution: Resolved
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 August 2024
Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operation, in which case no floating waterlight is required. Aft stbd ring buoy waterlight did not energize when activated.
46 cfr 180.70d
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 21 August 2024
Resolution: Rectified on the spot
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 August 2023
Resolved
A device must be provided to automatically shut down power ventilation serving the protected space
and engines that draw intake air from the protected space prior to release of the extinguishing agent
into the space. Port side engine did not shut down upon activation of the CO2 pressure switch.
46CFR181.410(b)(10)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 August 2023
Resolution: Wiring was re-installed. System was tested and M/E shut down occured.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 August 2023
Resolved
System design and installation must be in accordance with the Marine Design, Installation,
Operation, and Maintenance Manual approved for the system by the Commandant. Charge indicator valve on the stbd CO2 system is indicating system is pressurized.
46CFR181.410(a)(3)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 August 2023
Resolution: Charge vavle was reset. Service tech confirmed system is operational and ready.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 August 2023
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which
it is installed and capable of operating at constant marine load under such requirements without
exceeding its designed limitations. Stbd engine turbo oil supply line has an excessive oil leak.
46CFR182.200(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 August 2023
Resolution: Gasket on supply line was replaced. M/E was turn on for leak verification. None observed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 August 2023
Resolved
Fire hoses ...lined commercial fire hose that conforms to UL 19 (incorporated by reference, see 46 CFR
175.600) or hose that is listed and labeled by an
independent laboratory... Upper deck fire hose has
multiple holes.
46CFR181.320(b)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 August 2023
Resolution: Fire hose was replaced and placed under pressure. No leaks observed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 August 2023
Resolved
All engines must have at least two means for stopping the engine(s) under any operating conditions. The
fuel oil shutoff required at the engine by § 182.455(b)(4) will satisfy one means of stopping the engine. Stbd fuel shutoff does not fully close (aprox 90% closed) the fuel shutoff ball valve.
46CFR182.200
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 August 2023
Resolution: Fuel shutoff wire was re-routed. New configuration closed the ball valve to fule tank 100%.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 August 2023
Resolved
Complete but simple instructions for the operation of a fixed gas fire extinguishing system must be
located in a conspicuous place at or near each pull box. Stbd CO2 activation station (pull box) does not have instruction on how to activate the CO2 system.
46CFR185.612(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 August 2023
Resolution: Instructions for CO2 system wes re-mounted at pull station.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 22 August 2023
Resolved
There must be a means of accurately determining the amount of fuel in each fuel tank either by sounding,
through a separate sounding pipe or a fill pipe, or by an installed marine type fuel gauge. Port side fuel tank has an inoperable fuel gauge.
46CFR182.445(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 September 2023
Resolution: Fuel tank sending device was replaced with a marine WEMA S3U fuel tank sensor, w/ 14 gauge wiring.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 August 2023
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked. Child life jackets are not marked with the exact amount of life jackets stored on-board.
46CFR180.78(a)(5)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 September 2023
Resolution: Marking of lifejackets was updated to reflect adult and child lifejackets in designated compartment.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 August 2023
Resolved
The stowage locations of the personal flotation devices carried in addition to life jackets under § 180.72, must be separate from the life jackets... Excess adult life jackets are storesd in same compartment as in service life jackets.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 September 2023
Resolution: Excess lifejackets in storage compartment were removed and placed in designated area; all sat.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 August 2023
Resolved
Each portable fire extinguisher on a vessel must be of
an approved type. Fire extinguished bracket at operating station cannot fully secure mounted fire extinguisher.
46CFR181.500(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 September 2023
Resolution: Operating station fire extinguisher was replaced with a new fastening bracket accommodating a 10BC fire extinguisher; all sat.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 22 August 2023
Resolved
Where the station power does not exceed 250 watts carrier power or 1500 watts peak envelope power, the radio operator must hold a marine radio operator permit or higher class license. Vessel captain could not provide marine radio operator license upon request.
47CFR80.159(e)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 August 2023
Resolution: Marine Radio Permit was provided.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 22 August 2023
Resolved
A hatch cover must: (1) Have securing devices. Hatch leading to port and stbd engine room spaces cannot be secured. ***To be rectified by next dry dock.***
46CFR179.360(b)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 September 2023
Resolution: Broken handles were replaced. Hatch can be secured.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 22 August 2023
Resolved
A hatch cover must: (2) Be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. Hatch to stbd fuel tank space does not a chain or other device to prevent the loss of hatch when not secured.***To be rectified by next dry dock.***
46CFR179.360(b)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 September 2023
Resolution: Port and stbd hatch installed with securing line; all sat.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 August 2023
Resolved
Be installed with metal supports spaced not more than 610 millimeters (24 inches) apart, and in
such a manner as to avoid chafing and other damage. Electrical cables support in port side CO2 space have detached from ceiling. ***To be rectified by next dry dock.***
46CFR183.340 (b)(4)
Action required: 705 - Other - as specified
Resolved 28 September 2023
Resolution: Cable mount was re-attached to celling.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 August 2023
Resolved
Equipment, materials, and arrangements not covered by standards in this subchapter may be inspected...as
good marine practice. Mechanical seal on port side fire pump is leaking excessively. ***To be rectified by next dry dock.***
46CFR176.800(a)
Action required: 705 - Other - as specified
Resolved 28 September 2023
Resolution: Mechanical seal was replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 June 2022
Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Electrical outlet in galley, port side aft, below the serving counter did not have a cover plate and was not properly secured to the bulkhead.
46 CFR 183.200(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2022
Resolved 16 June 2022
Resolution: Outlet has been properly secured and a cover plate has been added.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 15 June 2022
Resolved
A fire pump must be capable of both remote operation from the operating station and local operations at the pump. Starboard side local operation switch is inoperable.
46 CFR 181.300(e)
Action required: 10 - Deficiency Rectified
Resolved 15 June 2022
Resolution: Electrician replaced switch and tested SAT.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 June 2022
Resolved
Spanner wrenches must be provided where a 40 millimeter (1.5 inch) diameter firehose is required by § 181.320(b). Main deck aft fire station was missing the spanner wrench.
46 CFR 181.310(d)
Action required: 10 - Deficiency Rectified
Resolved 15 June 2022
Resolution: Spanner wrench was placed at the fire station.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 22 October 2019
Resolved
Prove proper operation of the port fwd engine room fan.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 June 2022
Resolution: Port FWD E/R fan is operable.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 October 2019
Resolved
Both port and starboard engines have exhaust leaks at the turbos.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 June 2022
Resolution: All exhaust leaks repaired SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 October 2019
Resolved
All cable must be installed with metal supports spaced not more than 24 inches apart. In the port engine room, a cable run near the aft end of the engine was held in place with rope. Remove rope and support cables with metallic supports.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 June 2022
Resolution: Wire runs have been properly supported.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 9 October 2019
Resolved
All machinery must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure and personal injury. The heat detector over the port engine was held in place with a plastic wire tie. Remove plastic wire tie and remount heat detector with appropriate hardware.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 June 2022
Resolution: Heat detector has been properly mounted.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 1 October 2019
Resolved
Fire pipe discharge pipe in starboard engine room was wasted and leaking excessively. Wasted hole was covered up with electrical tape as a repair. Repair/renew pipe to original condition.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 9 October 2019
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 11 September 2019
Resolved
Vessel Captain and crew were not familiar with the vessel fire suppression system on board and how it operated.
Action required: 30 - Ship detained
Resolved 9 October 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 September 2019
Resolved
Both port and starboard engines have exhaust leaks at the turbos.
Condition: Damaged By Earlier Event
Action required: 30 - Ship detained
Resolved 9 October 2019
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 11 September 2019
Resolved
Both bilge areas have excessive oil and fuel accumulation to present a significant fire hazard to the vessel.
Action required: 30 - Ship detained
Resolved 10 October 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 11 September 2019
Resolved
Fuel leak found on port side generator prior to operating unit.
Action required: 10 - Deficiency Rectified
Resolved 11 September 2019
Resolution: Repairs were made to correct the fuel leak while inspectors were on nearby vessels. Inspectors attended the vessel and found that the fittings were repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 11 September 2019
Resolved
Port side fwd engine room fan was found to be completely inoperable and provided no ventelation to the space. The space was being filled with engine exhaust at the time of the inspection making it hard to breath inside.
Action required: 10 - Deficiency Rectified
Resolved 11 September 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 September 2019
Resolved
Guard on starboard side aft engine room fan was worn to the point it was missing and could easily cause bodily harm to an individual in the machinery space.
Action required: 10 - Deficiency Rectified
Resolved 11 September 2019
Resolution: New fan guard material was fitted over the fan to protect persons from rotating machinery.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 September 2019
Resolved
Both port and starboard engines were found to have minor jacket water leaks on the exhaust system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 June 2022
Resolution: Jacket water leaks were repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 September 2019
Resolved
Oil cap was found to be missing on the starboard main engine causing oil mist and blow by air to be existing the engine in a constant manner.
Action required: 10 - Deficiency Rectified
Resolved 11 September 2019
Resolution: A new cap was fitted.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 1 April 2019
Resolved
The fire pump outlet must be fitted with a pressure gauge; no gauge was provided.
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 10 April 2019
Resolution: Verified a gauge was provided on the discharge side of the pump and witnessed an operational test.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 1 April 2019
Resolved
Piping exceeding 150 degrees must be suitably insulated to prevent injury; part of the stbd engine lagging was removed.
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 10 April 2019
Resolution: Verified lagging was provided.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 April 2019
Resolved
All cable and wire be installed with metal supports not more than 24" apart, plastic tie wraps are limited to bundling, the inboard main wire run in the stbd engine room relies solely on zip ties for support.
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 10 April 2019
Resolution: Verified identified cables were properly supported.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 1 April 2019
Resolved
Penetrations in a watertight bulkhead must be made watertight; sealant for the CO2 piping penetrations in the stbd engine room aft bulkhead was missing.
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 10 April 2019
Resolution: Verified identified watertight bulkhead openeings were properly sealed.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 1 April 2019
Resolved
Remote fuel shutoff valves stations must be clearly marked; provided labels were faded and unreadable.
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 10 April 2019
Resolution: Verified appropriate lables were provided.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 April 2019
Resolved
Each electrical motor must be mounted above the bilge to avoid damage by splash and avoid low lying vapors; identified an msd pump in the bilge of the stbd msd void.
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 10 April 2019
Resolution: Verfied identified motor was mounted higher above the bilge.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 1 April 2019
Resolved
Conduct drills prior to seasonal operations.
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 30 April 2019
Resolution: Completed underway drills all sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 August 2018
Resolved
Prove proper operation of the starboard engine to the USCG inspector attending.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 April 2019
Resolution: Witnessed an operational test of the stbd main diesel engine.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 August 2018
Resolved
make Starboard exhaust pipping water tight.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 April 2019
Resolution: Witnessed an operational test of the stbd main diesel engine and observed no water intrusion through the exhaust piping.
Fire Fighting › Fire Pumps › Arrangement
Issued 10 May 2018
Resolved
A fire pump must be capable of remote operation from the operating station, there are no means to energize fire pump from the bridge.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2018
Resolved 16 August 2018
Resolution: Tested remote start of fire pump from the operating station
Navigation › Piloting/Steering › Marine Charts
Issued 10 May 2018
Resolved
Provide up-to-date nautical charts.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2018
Resolved 11 May 2018
Resolution: Verified up-to-date marine charts were provided
Fire Fighting › Fire Hoses › Condition
Issued 10 May 2018
Resolved
Fire hose length cannot exceed 50', provide proper hose for the main deck station.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 May 2018
Resolved 11 May 2018
Resolution: Verified a proper fire hose was provided.
Construction/Loadline › Penetrations › Pipe Flange
Issued 10 May 2018
Resolved
Sluice valves are not permitted in watertight bulkheads, remove and cap valves on the on both port and starboard collision bulkheads and port and starboard fwd engine room bulkheads.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2018
Resolved 11 May 2018
Resolution: Verified valves were removed and through bulkhead penetrations were capped.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 10 May 2018
Resolved
Flexible pipe sections of fuel fill and sounding pipes must be bonded to protect against static charge.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2018
Resolved 11 May 2018
Resolution: Verified flexible pipe sections of both fuel tanks were bonded.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 8 May 2018
Resolved
Provide MSC approval of submitted CO2 Suppression system plans
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 August 2018
Resolution: Vessel has RCVD MSC approval.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 8 May 2018
Resolved
A pressure relief valve or equivalent set between 2400-2800 psi must be installed in the distribution manifold. A relief devices is not currently installed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 August 2018
Resolution: vessel has installed pressure releif valve.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 8 May 2018
Resolved
Install proper markings for spaces storing carbon dioxide
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2018
Resolution: Verified proper warning sings were provided for the discharge and storage spaces.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 8 May 2018
Resolved
Install schematic diagram of system and instructions detailing alternate methods of releasing extinguishing agent should local manual valve controls fail to operate.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 August 2018
Resolution: Vesselhas installed diagram and releasing instructions.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 8 May 2018
Resolved
Install dirt traps after the siren in both engine rooms.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2018
Resolution: Verified dirt traps were provided.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 11 October 2017
Resolved
Both time delay bottles failed Port side tripped at 15 seconds and Starboard side at 12.5.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 10 May 2018
Resolution: System was renewed.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 13 October 2016
Resolved
Relocate the two pressure switches for the fixed CO2 suppression system for the port & STBD engineroom as per MTN 01-04 - 16715 22 Sept 2004 & Marine Safety Alert Inspections & Compliance Directorate Alert 05-12 & 6-15.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 April 2017
Resolved 22 May 2017
Resolution: Verified switches were relocated. Switches and disturbed plumbing tested by servicing company, all sat.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 3 May 2016
Resolved
Annual service all onboard portable fire extinguishers. All found past due for annual service/inspection.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 May 2016
Resolved 27 May 2016
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 3 May 2016
Resolved
Renew batteries on all onboard e-lighting. Lights are required to have 2 hr capacity. Found most not working or dying within 10 mins of testing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 27 May 2016
Electrical › Electrical Distribution System (service) › Junction Box
Issued 3 May 2016
Resolved
Replaced missing electrical junction box cover on the forward, stbd side, engine room ventilation fan motor.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 27 May 2016
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 3 May 2016
Resolved
Properly label engine room ventilation dampers and provide training on the system since crew was unable to explain how they operate or how to close the same.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 May 2016
Resolved 27 May 2016
Construction/Loadline › Structures › Transverse Bulkhead
Issued 3 May 2016
Resolved
Properly plug sluice valves in the collision bulkhead both port and stbd hulls.
Condition: Invalid
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 27 May 2016
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 3 May 2016
Resolved
Replace missing cover for the MSD pump electrical motor which exposes high speed fan on the back side of the electrical motor creating a safety hazard for occupants.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 27 May 2016
Fire Fighting › Remote Fuel Shutoff › General
Issued 3 May 2016
Resolved
Properly repair the stbd engine room remote emergency fuel shut off valve which is sticking/binding.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 May 2016
Resolved 27 May 2016
Engineering › Bilge Water Management System › Interface Detector
Issued 3 May 2016
Resolved
Properly mount broken bilge alarm float switch in the stbd hull MSD void.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 27 May 2016
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 3 May 2016
Resolved
Place placard next to typhone alarms in both engine rooms stating "WHEN ALARM SOUNDS-VACATE AT ONCE HALON BEING RELEASED".
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 27 May 2016
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 3 May 2016
Resolved
Renew two broken windows in the vessels pilot house port and stbd side. Drop down windows...
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 27 May 2016
Resolution: Owner renewed windows with proper safety glass hose tested SAT.
Navigation › Piloting/Steering › Binnacle
Issued 3 May 2016
Resolved
Properly repair or renew vsl's compass which is low on fluid. Ethelyn Glycol Distilled Water.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 27 May 2016
Resolution: Install new compass.
Communications › Radio Communications › EPIRB
Issued 3 May 2016
Resolved
Renew vessels NOAA registration. Vsl ltd to no more than 3 miles fm shore until this is resolved.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 27 May 2016
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 3 May 2016
Resolved
Repair broken railing on the port side bow, courses broken off making more than 4"s of space between courses.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 27 May 2016
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 3 May 2016
Resolved
Properly repair exhaust water leak on exhaust flange port MDE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 27 May 2016
Construction/Loadline › Structures › Transverse Bulkhead
Issued 3 May 2016
Resolved
Properly plug/seal two bulk head penetrations on the port side transverse bulk head in steering gear room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 27 May 2016
Construction/Loadline › Structures › Transverse Bulkhead
Issued 3 May 2016
Resolved
Replace missing bolt on manhole cover (acces plate) in the port engine room to make water tight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 27 May 2016
Electrical › Electric Supply System (service) › Battery Charger
Issued 3 May 2016
Resolved
Permanently hard wire battery charger, charging leads in the port side engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 27 May 2016
Electrical › Electrical Distribution System (service) › Junction Box
Issued 3 May 2016
Resolved
Install missing electrical junction box cover port engine room exhaust fan.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 27 May 2016
Construction/Loadline › Hull › Bottom Plating
Issued 3 May 2016
Resolved
At the vsl's next dry dock remove bilge pumps and gauge hull under stainless steel bilge pump suction strainers that are in contact with the aluminum hull with notable pitting starting around the hull in area of contact.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 18 November 2016
Resolution: Gauging indicated 3/8" plate and a visual inspection of the areas revealed surface pitting with a max depth of around 1/16".