Records from 1983 to 2009. Most recent: inspection, 13 January 2009.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 21
13 January 2009
PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3393493
3 May 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2639745
4 May 2005
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2348938
21 June 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2105826
25 May 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 6476
14 November 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1121204
13 June 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 775720
23 May 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1172903
27 July 1992
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1266465
16 July 1991
Administrative
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1248418
21 June 1991
Damage Survey
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 939502
7 June 1991
COI Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1207767
28 June 1990
Re-Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 932137
7 August 1989
Administrative
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1207924
24 July 1989
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1344271
9 June 1989
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1201457
9 July 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1012329
11 December 1986
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1030011
10 May 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 982117
6 April 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1284245
6 April 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1273557
Construction/Loadline
Issued 21 June 1991
Resolved
IN THE FOLLOWING AREAS DRAIN WATER, CLEAN OUT, AND WELD UP OR INSERT AS NEEDED: AFT END OF PORT SKEG ON BOTTOM; RUB RAIL, PORT SIDE, ABOUT FR 26.
Condition: Unknown
Due 15 August 1991
Resolved 15 August 1991
Construction/Loadline
Issued 21 June 1991
Resolved
MAKE THE FOLLOWING REPAIRS: REPLACE AS ORIGINAL THE DAMAGED AREA AT THE BOW; CROP AND RENEW AROUND THE HOLE FORWARD OF THE BOW THRUSTER, PORT SIDE,AN AREA ABOUT 18" BY 36".
Condition: Unknown
Due 15 August 1991
Resolved 15 August 1991
Construction/Loadline
Issued 21 June 1991
Resolved
IN THE FOLLOWING AREAS GOUGE OUT TO GOOD METAL AND WELD UP: THE CRACK ON STARBOARD SIDE OF KEEL ABOUT 6 FEET AFT OF BOW THRUSTER; PUNCTURE ON BOTTOMNEAR KEEL ON STARBOARD SIDE NEAR KEEL ABOUT FRAME 17.
Condition: Unknown
Due 15 August 1991
Resolved 15 August 1991
Engineering
Issued 7 June 1991
Resolved
MAKE OPERABLE AND TEST #3 GEN OVERSPEED TRIP.
Condition: Unknown
Due 7 June 1991
Resolved 7 June 1991
Electrical
Issued 7 June 1991
Resolved
MAKE LIGHTS IN MAIN ELECTRICAL PANEL OPERABLE.
Condition: Unknown
Due 7 June 1991
Resolved 7 June 1991
Construction/Loadline
Issued 7 June 1991
Resolved
MAKE BALLAST PUMP OPERABLE.
Condition: Unknown
Due 7 June 1991
Resolved 7 June 1991
Documentation
Issued 7 June 1991
Resolved
UPDATE ALL VESSEL DOCUMENTS THAT HAVE EXPIRED DATES.
Condition: Unknown
Due 7 June 1991
Resolved 7 June 1991
Accommodation/Occupational Safety
Issued 24 July 1989
Resolved
REMOVE ALL ADDED BUNKS AND BULKHEADS, RETURN VESSEL TO ORIGINAL DECK ARRANGEMENT. INSTRUMENT AND NAVIGATION ROOMS ARE NOT TO BE USED FOR BERTHING, CAPTAINS ROOM MAYBE USED ONCED RETURNED TO ORIGINAL CONFIGURATIONALL EXCESS BEDDING MUST BE REMOVE PRIOR TO LEAVING VALDEZ, ALASKA.
Condition: Unknown
Due 24 July 1989
Resolved 24 July 1989