SOUTH SEAS II

SOUTH SEAS II is a 1984 passenger vessel (inspected). The Coast Guard has recorded 87 inspections since 1985, most recently in November 2025, along with 136 deficiencies, 1 operational control and 2 casualty investigations between 2019 and 2025.

Records from 1985 to 2025. Most recent: inspection, 24 November 2025.

Built
1984
Last inspected
24 November 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCV3804
235288
Flag
UNITED STATES
367064220
Maury page id
psix-235288

Inspections, by type

…with no type recorded13
Years with a record 36 calendar years (1985–2025)
The 87 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)38.0 ft × 12.5 ft × 5.2 ft
Registered tonnagegross 17 / net 13
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDELTA BOAT WORKS · CAPE CANAVERAL FL, UNITED STATES · built 1984
Hull materialFRP (Fiberglass)
PropulsionDiesel
Hull shapeShip
Hull configurationMonohull
Hailing portWAIANAE, HI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 13 November 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it17 - Simplified, Gross Ton
13 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCV3804MMSI 367064220 · active · compulsorily equipped · granted 1 January 2026, expires 6 November 2035
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 87

24 November 2025 Vessel Attendance · Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8268323
21 March 2025 Damage Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8097356
20 March 2025 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8114013
11 December 2024 Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8012130
3 September 2024 Deficiency Check · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7975051
10 January 2024 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7847667
17 October 2022 Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7568210
21 January 2022 Drydock Exam · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7385771
2 November 2020 Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7088665
21 October 2020 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7082059
27 August 2020 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7035759
28 January 2020 Deficiency Check · Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6897894
16 October 2019 Administrative Inspection · Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6835836
16 October 2019 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6841600
23 August 2018 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6512434
3 May 2018 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6408542
18 January 2018 Drydock Exam · Internal Structural Exam · Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6338846
15 November 2017 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6307351
7 November 2016 Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6041028
19 January 2016 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5799994
20 August 2015 Administrative Inspection · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5192874
17 January 2012 Hull Examination · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4225988
12 February 2011 Type not recorded
No type recorded · USCGC AHI (WPB 87364) · USCG Oceania District (CGD-O) · Activity 3946117
3 November 2010 Type not recorded
No type recorded · USCG Oceania District (dre) · USCG Oceania District (CGD-O) · Activity 3884337
24 October 2010 Type not recorded
No type recorded · USCGC AHI (WPB 87364) · USCG Oceania District (CGD-O) · Activity 3876593
12 January 2010 Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3659973
2 October 2008 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3337482
22 January 2008 Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3134490
21 November 2007 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3102577
2 April 2007 Type not recorded
No type recorded · USCGC AHI (WPB 87364) · USCG Oceania District (CGD-O) · Activity 2903267
24 February 2007 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2876093
5 June 2006 Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2671449
13 February 2006 Internal Structural Exam · Construction Oversight · Hull Examination · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2584351
28 September 2005 Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2503338
4 November 2004 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2229765
6 January 2004 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1945448
19 November 2003 Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1951033
24 September 2002 Deficiency Check · Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1673756
28 January 2002 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1478571
10 October 2001 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1373637
13 September 2000 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1055057
5 September 2000 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1441742
14 January 2000 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 814041
14 January 2000 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1432241
22 December 1999 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 811865
12 November 1999 Deficiency Check · Drydock Extension
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1369418
19 October 1999 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1471212
13 October 1998 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1375527
13 April 1998 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 788678
18 November 1997 Hull Examination · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1411561
21 October 1997 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 780867
5 September 1997 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1368386
18 June 1997 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1111880
9 June 1997 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1428779
2 February 1997 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 65346
25 September 1996 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 144361
5 September 1996 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1363775
8 December 1995 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1377565
27 October 1995 Re-Inspection · Hull Examination · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1437030
6 September 1994 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1367167
22 March 1994 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1456150
7 January 1994 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 159682
20 September 1993 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1442061
22 January 1993 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 25769
19 October 1992 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1244475
3 September 1992 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 945018
21 May 1992 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 160975
16 April 1992 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1268978
26 March 1992 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 944949
24 September 1991 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1004502
13 September 1991 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 938099
9 September 1991 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1254292
24 April 1991 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 927989
20 February 1991 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 921566
17 September 1990 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1236164
14 November 1989 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 919854
25 September 1989 Hull Examination · Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 899240
12 September 1989 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1037681
19 September 1988 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1036872
9 September 1988 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1037029
14 July 1988 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1343068
9 June 1988 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1033538
4 December 1987 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1308391
28 September 1987 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1015372
20 October 1986 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1008864
29 April 1986 Credit Drydock
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1000708
17 October 1985 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1298576

Deficiency record · 136

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 November 2025 Resolved
For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Evidence of the required inspections and tests for the pre-engineered fixed gas fire extinguishing system not provided. Provide evidence of the required inspections and test system in the presence of the attending marine inspector. 46 CFR 176.810(b)(2)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 November 2025
Resolution: Received documentation of fire boy service by Kewalo Marine Service.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 November 2025 Resolved
A pre-engineered fixed gas fire extinguishing system must: be installed in accordance with the manufacturer's instructions. The engine room containing the vessel's pre-engineered fixed gas fire extinguishing system had multiple unsealed openings through both forward and aft bulkheads. Seal all openings in engine room bulkheads, so that pre-engineered fixed gas fire extinguishing system is installed in accordance with manufacturer's instructions to the satisfaction of the attending marine inspector. 46 CFR 181.420(a)(4)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 November 2025
Resolution: Sealed boundaries surrounding pre-engineered fire system protected space.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 25 November 2025 Resolved
At each initial and subsequent inspection for certification, the marine inspector may require that an abandon ship or man overboard drill be held under simulated emergency conditions as specified by the inspector. Vessel was unable to go underway and demonstrate competency in man overboard and abandon ship drills due to no sail deficiencies. Clear deficiencies and conduct man overboard drill in the presence of the attending marine inspector. 46 CFR 176.808(d)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 November 2025
Resolution: Conducted satisfactory man overboard drill.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 25 November 2025 Resolved
At each initial and subsequent inspection for certification, the marine inspector may require that a fire drill be held under simulated emergency conditions to be specified by the inspector. Vessel was unable to go underway and demonstrate competency in fire drill due to no sail deficiencies. Clear deficiencies and conduct man overboard drill in the presence of the attending marine inspector. 46 CFR 176.810(d)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 November 2025
Resolution: Conducted satisfactory fire drill.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 November 2025 Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10. Required fire extinguisher's pressure gauge in the forward cabin reflected "recharge". Recharge or replace fire extinguisher to the satisfaction of the attending marine inspector. 46 CFR 176.810(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 November 2025
Resolution: Replaced all three portable fire extinguishers.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 25 November 2025 Resolved
A vessel on an oceans, coastwise, limited coastwise, or Great Lakes route must carry: six red flare distress signals approved in accordance with 160.021 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.121, and six hand orange smoke distress signals approved in accordance with 160.037 in subchapter Q of this chapter, or other standard specified by the Commandant. All of the flares on board the vessel were expired. Replace all flares to include six orange, and six red flares, to the satisfaction of the attending marine inspector. 46 CFR 180.68(a)(1)&(2)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 November 2025
Resolution: Purchased new distress signals.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 November 2025 Resolved
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a) only on a vessel of not more than 19.8 meters in length carrying not more than 49 passengers, provided that: the pump is listed by an independent laboratory as meeting the requirements in UL 1113. All three submersible electric bilge pumps on board did not meet UL 1113. Obtain and install submersible electric bilge pumps meeting the UL 1113 standard to the satisfaction of the attending marine inspector. 46 CFR 182.520(e)(1)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 November 2025
Resolution: Installed three new UL approved submersible electric bilge pumps.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 November 2025 Resolved
Provisions shall be made by means of plugs, covers, etc., to prevent the admission of air into the space protected. Covers for ventilation ducts were not properly installed and/or wasted. Ensure that all ventilation covers are in good working order to satisfaction of attending marine inspector. 46 CFR 181.20-35 (Old T)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 November 2025
Resolution: Provided covers for ventilation ducts that can actuate from outside the engine room.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 25 November 2025 Resolved
A vessel at anchor shall exhibit where it can best be seen:(ii) At or near the stern and at a lower level than the light prescribed in paragraph (i) of this Rule, an all-round white light. Anchor light configuration is currently one all around white light near helm and a 135 degree white stern light. Reconfigure anchor light to ensure only one all around light is lit to satisfaction of attending marine inspector. 33 CFR 83.30 (a)(ii)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 November 2025
Resolution: Adjusted anchor light configuration to the white all around mast only.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 November 2025 Resolved
Each life jacket must be approved in accordance with either 160.002, 160.005, or 160.055 in subchapter Q of this chapter. Found 12 adult life jackets and 3 child life jackets condemned on site due to degradation. Passenger count reduced to 13 adult passengers and 0 child passengers until life jackets are replaced to satisfaction of attending marine inspector. 46 CFR 180.71 (c)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 3 December 2025
Resolution: Received photos of newly procured life jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 November 2025 Resolved
Each ring life buoy on a vessel must be approved in accordance with 160.050 in subchapter Q of this chapter. MI found 01 life ring buoy with a wasted plug and grab line. Replace ring life buoy to satisfaction of attending marine inspector. 46 CFR 180.70(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 December 2025
Resolved 3 December 2025
Resolution: Received photos of newly procured life ring buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 November 2025 Resolved
At least one ring life buoy must be fitted with a 60 foot lifeline. Found lifeline fitted on 01 ring life buoy to be wasted. Replace to satisfaction of attending marine inspector. 46 CFR 180.70(c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 December 2025
Resolved 3 December 2025
Resolution: Received photos of newly procured life line.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 25 November 2025 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. First aid kit missing 48 doses of analgesic medication. Provide doses of analgesic medication to satisfaction of attending marine inspector. 46 CFR 184.710
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 December 2025
Resolved 9 December 2025
Resolution: Received photos of analgesic medicine onboard.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 25 November 2025 Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications. Station license is expired and no crew has a marine radio operator permit. Renew license and obtain permit to satisfaction of attending marine inspector. 46 CFR 184.502
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 December 2025
Resolved 1 January 2026
Resolution: Received photo of FCC documents.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 November 2025 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Placard present but not visible to passengers. Relocate placard to satisfaction of attending marine inspector. 46 CFR 185.516
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 December 2025
Resolved 28 November 2025
Resolution: Relocated placard.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 25 November 2025 Resolved
The EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable. Found no testing or log of EPIRB testing onboard. Properly test and document log of EPIRB testing to the satisfaction of attending marine inspector. 46 CFR 185.702 (c)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 December 2025
Resolved 9 December 2025
Resolution: Received photos of new EPIRB testing log.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 25 November 2025 Resolved
When operating a vessel on a body of water where the discharge of untreated sewage is prohibited the operator must secure each Type III device in a manner which prevents discharge of sewage. Acceptable methods of securing the device include—(1) Closing each valve leading to an overboard discharge and removing the handle;(2) Padlocking each valve leading to an overboard discharge in the closed position; or(3) Using a non-releasable wire-tie to hold each valve leading to an overboard discharge in the closed position. Sewage overboard valve not secured. Secure to satisfaction of attending marine inspector. 33 CFR 159.7 (c)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 December 2025
Resolved 9 December 2025
Resolution: Received photo of valve handle removed.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 25 November 2025 Resolved
Flexible hose may be used provided it is fitted with suitable connection fittings and has high resistance to saltwater, petroleum oils, and vibration. Non SAE J-1942 hoses installed in fuel system with barbed (non SAE J-1475) connection fittings. Replace with fire rated hose with SAE J-1942 hose and SAE J-1475 connection fittings to satisfaction of attending marine inspector. 46 CFR 182.20-40 (Old T)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 December 2025
Resolved 9 December 2025
Resolution: Received photo of newly installed approved hose.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 25 November 2025 Resolved
The discharge ends of vent pipes shall be fitted with removable flame screens or flame arrestors. The flame screens shall consist of a single screen of corrosion resistant wire of at least 30x30 mesh. Flame screen for fuel tank vent is painted over. Remove paint or replace flame screen to satisfaction of attending marine inspector. 46 CFR 182.20-35 (Old T)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 December 2025
Resolved 15 December 2025
Resolution: Received photo of flame screen properly installed.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 25 November 2025 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Fuel tank vent hose is wasted posing risk of fuel leaking into bilge. Replace fuel tank vent hose to satisfaction of attending marine inspector. 46 CFR 176.830
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 December 2025
Resolved 9 December 2025
Resolution: Received photo of new fuel tank vent line installed.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 25 November 2025 Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information:(1) Date of the drill and training; and(2) General description of the drill scenario and training topics. Only one man overboard drill was logged and provided upon request. Establish abandon ship and man overboard drill log for vessel to satisfaction of attending marine inspector. 46 CFR 185.520
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 December 2025
Resolved 9 December 2025
Resolution: Received photos of logged drills.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 25 November 2025 Resolved
Fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information:(1) Date of the drill and training; and(2) General description of the drill scenario and training topics. No fire fighting drills logged. Establish fire fighting drill log for vessel to satisfaction of attending marine inspector. 46 CFR 185.524
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 December 2025
Resolved 9 December 2025
Resolution: Received photo of logged drills.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 25 November 2025 Resolved
Except as otherwise provided in this section, rails or equivalent protection shall be installed near the periphery of all weather decks accessible to passengers and crew. Swim step railing socket is broken and does not provide protection to passengers. Repair swim step railing to satisfaction of attending marine inspector. 46 CFR 177.35-1 (Old T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 December 2025
Resolved 9 December 2025
Resolution: Received photo of repaired socket.
09 - Working and Living Conditions › 091 - Living Conditions › Drainage
Issued 25 November 2025 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Port engine space hatch cover drainage piping is broken/missing allowing water to drain freely into the engine room bilge. Repair drainage piping to satisfaction of attending marine inspector. 46 CFR 176.830
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 December 2025
Resolved 9 December 2025
Resolution: Received photo of drainage piping repaired.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 November 2025 Resolved
Employers must ensure that they and their crew members meet the requirements of this part. 1) No written EAP program is in place for the company; 2) No crew or supervisor training; and 3) Missing company policy statement. Chemical testing program compliance audit required. Schedule audit and complete audit by 19 December 2025, to satisfaction of attending marine inspector. 46 CFR 16.203(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 December 2025
Resolved 8 January 2026
Resolution: Vessel owner scheduled the DAPI audit. Refer to Activity #8292479 for audit results.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 March 2025 Resolved
The OCMI may require an inspection and testing whenever a repair or alteration is undertaken. Vessel experience marine casualty. Make vessel ready for inspection. 46 CFR 176.700(d)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 21 March 2025
Resolution: Vessel was inspected and repairs made to the satisfaction of attending marine inspector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 December 2024 Resolved
The OCMI may require the vessel to get underway. Get underway in presence of marine inspector to conduct fire and man overboard drills. 46 CFR 176.404 (a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 December 2024
Resolved 12 December 2024
Resolution: Vessel got underway to conduct drills.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 11 December 2024 Resolved
A hatch exposed to the weather must be watertight. Gasket material for lazarette deck hatch is missing. 46 CFR 179.360(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 December 2024
Resolved 12 December 2024
Resolution: Vessel renewed gasket material.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 11 December 2024 Resolved
A hatch cover must be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. Port side engine room hatch not secured. 46 CFR 179.360(b)(2)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 December 2024
Resolved 12 December 2024
Resolution: Vessel added lanyard to hatch.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 11 December 2024 Resolved
The person in command of a documented vessel must have on board that vessel the original Certificate of Documentation currently in effect for that vessel. Valid COD is not onboard the vessel. 46 CFR 67.313(a)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 December 2024
Resolved 25 December 2024
Resolution: Vessel posted valid COD.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 December 2024 Resolved
An individual may not be engaged or employed, including self-employment, on a vessel in a position as master, operator, or person in charge for which a credential is required by law or regulation unless all crewmembers covered by this section are subject to the random testing requirements of this section. Crewmembers onboard for inspection have not completed preemployment drug testing and are not enrolled in the consortium. 46 CFR 16.230(k)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 December 2024
Resolved 11 January 2025
Resolution: Operator showed evidence of enrollment in a drug program.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 January 2024 Resolved
On a nonmetallic vessel, the enclosures and frames of electrical equipment must be bonded together to a common ground by a normally non-current carrying conductor. Bonding conductor for steering assembly is disconnected. 46 CFR 183.372(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 January 2024
Resolved 12 January 2024
Resolution: Ground wire reattached to hull.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 10 January 2024 Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. If the ship passes the inspection, the technician will issue a Communications Act Safety Radiotelephony Certificate. Vessel Could not provide a copy of their Safety Radiotelephony Certificate. 47 CFR 80.903
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 January 2024
Resolved 11 January 2024
Resolution: Provided proof of valid Communications Act Safety Radiotelephony Certificate.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 10 January 2024 Resolved
Except as otherwise allowed by this subpart, a vessel must comply with the structural design requirements of one of the standards listed below for the hull material of the vessel. Vessel has hull damage impairing weather tight integrity above the waterline of the hull on the starboard side. To be repaired before credit dry dock. 46 CFR 177.300(a)
Action required: 705 - Other - as specified
Resolved 11 September 2024
Resolution: Satisfactory repairs conducted while in drydock. See narrative for details.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 17 October 2022 Resolved
Provision shall be made by means of plugs, covers, etc., to prevent the admission of air into the space protected. Starboard damper in engine compartment did not actuate when cable was pulled. Provide proper activation of the starboard side damper. 46 CFR 181.20-35 (a) [Old T]
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 November 2022
Resolution: Starboard side dampener was tested sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 October 2022 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Switch for fuel priming pump lacking proper installation. Properly secure switch or remove switch from engine room compartment. 46 CFR 183.01-15 (a) [Old T]
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 October 2022
Resolved 28 October 2022
Resolution: Switch secured.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 17 October 2022 Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. Engine room high water level alarm is inoperable. Replace alarm. Passenger count reduced by one, and supplemented by a crew member to conduct rounds on the engine room. 46 CFR 182.530(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 October 2022
Resolved 2 December 2022
Resolution: Replaced engine room high water level alarm.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 17 October 2022 Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. Forward compartment high water level alarm light is not operational. Fix light. 46 CFR 182.530(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 October 2022
Resolved 2 December 2022
Resolution: Replaced forward compartment high water level alarm light.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 October 2022 Resolved
Electrical equipment must be installed to protect from electrical hazards. Electrical wiring underneath operating station has several exposed and dead end wires. Properly remove or cover to prevent potential shock or fire hazards. 46 CFR 183.200
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 October 2022
Resolved 28 October 2022
Resolution: Dead-end wires removed.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 17 October 2022 Resolved
A vessel must carry either a first aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Identified expired contents in first aid kit. Replace. 46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 October 2022
Resolved 28 October 2022
Resolution: New first-aid kit provided.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 17 October 2022 Resolved
As appropriate for intended voyage, all vessels must carry adequate and up-to-date charts. Vessel did not have up-to-date charts onboard. Provide up-to-date charts. 46 CFR 185.20-35 [Old T]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 October 2022
Resolved 6 January 2023
Resolution: Vessel Operator provided proof of valid charts on vessel.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 November 2020 Resolved
The person in command of a documented vessel must have on board that vessel the original Certificate of Documentation currently in effect for that vessel. Vessel's Certificate of Documentation is expired. 46CFR67.313
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 December 2020
Resolved 24 November 2020
Resolution: COD issued to vessel.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 2 November 2020 Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed. Hydrostatic release for EPIRB is not marked with expiration date. Provide satisfactory receipt for date of installation or replace. 46CFR185.740
Action required: 705 - Other - as specified
Due 2 December 2020
Resolved 16 November 2020
Resolution: Recieved photograph of new hydrostatic release with expiration date marked.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 November 2020 Resolved
An adult life jacket must be provided for each person carried on board a vessel. 02 adult life jackets were cracked. Repair 02 adult life jackets IAW manufacturer's instructions as discussed. 46CFR180.71(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 December 2020
Resolved 16 November 2020
Resolution: Received photographs of maintenance conducted on required PFDs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 November 2020 Resolved
A number of child size life jackets equal to at least 10% of the number of persons permitted on board must be provided. 01 child size life jacket was cracked. Repair child size life jacket IAW manufactuer's instructions. 46CFR180.71(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 December 2020
Resolved 16 November 2020
Resolution: Received photograph of maintenance performed to required PFD.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 2 November 2020 Resolved
A hatch cover must have securing devices and be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strenght to prevent its loss. Provide hatch cover securing device for all deck hatches. 46CFR179.360
Action required: 705 - Other - as specified
Due 2 December 2020
Resolved 2 November 2020
Resolution: Recieved photographs of lanyards for deck hatches.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 November 2020 Resolved
A vessel not required to have a power driven fire pump by 181.300 must have at least three 2 1/2 gallon buckets, with an attached lanyard satisfactory to the cognizant OCMI. Vessel was missing 01 fire bucket. 46CFR181.610
Action required: 10 - Deficiency Rectified
Due 18 November 2020
Resolved 18 November 2020
Resolution: Vessel replaced fire bucket in the presence of the Marine Inspector.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 2 November 2020 Resolved
Electrical equipment on avessel must be installed and maintained to minimize accidental personnel contact with energized parts. Dead end wires found underneath the operating station. Remove or secure dead end wires IAW 46CFR183.200. 46CFR183.200(c)
Action required: 10 - Deficiency Rectified
Due 18 November 2020
Resolved 18 November 2020
Resolution: Dead end wires were removed in the presence of the Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 November 2019 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed. Engine air box is corroded and not providing the necessary protection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2020
Resolved 12 February 2020
Resolution: Verified satisfactory repairs were made to engine airbox.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 October 2019 Resolved
A pre-engineered fixed gas fire extinguishing system must be installed in accordance with the manufacturer's instructions. Demonstrate the pre-engineered fixed gas fire extinguishing system operate as designed per manufactures instruction. Vessel is not permitted to operate until CG inspector review the installation and testing of this system.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 November 2019
Resolution: New pre-engineered system installed and tested satisfactorily
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 16 October 2019 Resolved
Each vessel that operates on the high seas or that operates beyond three miles from coastline must have Cat 1, 406 MHZ EPIRB. Registration of EPIRB is outdated.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 November 2019
Resolution: EPIRB registered to expire 16 OCT 2022
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 16 October 2019 Resolved
Vessels operated solely within 20 nautical miles of land must be equipped with a VHF-DSC radiotelephone installation meeting the requirements of § 80.1101(c)(2) VHF radio missing MMSI for DSC operation.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 November 2019
Resolution: Verified MMSI input in VHF radio.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 16 October 2019 Resolved
A Certificate of Documentation is required for operation of a vessel in certain trades, serves as evidence of vessel nationality. Provide original documentation onboard.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 November 2019
Resolution: Original COD verfied onboard.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 16 October 2019 Resolved
FCC Station License require for operation of all maritime services transmitting equipment on board a vessel. FCC Station License is missing.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 November 2019
Resolution: Verified onboard to expire 11/6/2025
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 16 October 2019 Resolved
FCC Safety Radiotelephony Certificate for all radio equipment installation onboard. FCC Form 824 is missing.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 November 2019
Resolution: Verified to expire 10/19/21
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 16 October 2019 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 November 2019
Resolution: Licensed master had operators license
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 October 2019 Resolved
Connections must be made to battery terminals with permanent type connectors. Spring clips or other temporary type clamps are prohibited. Replace wing nut with permanent nut.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 November 2019
Resolution: Hex nuts on battery posts.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 16 October 2019 Resolved
Except for engine exhausts, each inlet or discharge pipe that penetrates the hull below a line drawn parallel to and at least 150 millimeters (6 inches) above the deepest load waterline must have means to prevent water from entering the vessel if the pipe fractures or otherwise fails. Provide valve with handle for overboard discharge in Lazarett.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 November 2019
Resolution: Valve with handle installed inline.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 16 October 2019 Resolved
A vessel must comply with the structural design requirements of one of the standards listed. Stbd aft vertical support beam is rotted in Lazarett. Submit a repair proposal for approval prior to carrying out the repairs.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 November 2019
Resolution: Rotted support frame replaced.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 16 October 2019 Resolved
A vessel must comply with the structural design requirements of one of the standards listed. Engineroom deck structures have fractures and signs of angel hair. Submit a repair proposal for approval prior to carrying out the repairs.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 November 2019
Resolution: Angel hair treated with epoxy resin.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 16 October 2019 Resolved
Deck rails must be designed and constructed to withstand a point load of 91 kilograms (200 pounds) applied at any point in any direction. Port and Stbd fwd rails are loose.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 November 2019
Resolution: All fwd deck rails rebedded and fastened.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 October 2019 Resolved
A vessel must comply with the structural design requirements of one of the standards listed. Swimming platform fractured and wasted. Replace in kind with same weighed swimming platform that does not change overall weight of vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2020
Resolved 12 February 2020
Resolution: Vessel's completed satisfactory repairs to the swim platform.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 4 September 2018 Resolved
On a vessel of at least 26 feet in length, a visual and audible indicator must be provided at the operating station indicate high water level in each normally unmanned space with a through-hull fitting, machinery space, shaft alley, space with non-watertight closure and other spaces subject to flooding. Install and demonstrate operation of audible and visual indicators for each space required.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 November 2018
Resolution: Vessel installed individual bilge alarms, both audible and visual tested sat.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 4 September 2018 Resolved
A visual indicator must be provided at the operating station to indicate when an automatic bilge pump is operating. Install a visual indicator for each automatic bilge pump.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 November 2018
Resolution: Visual indicators provided for automatic bilge pumps.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 4 September 2018 Resolved
Portable extinguishers must be inspected and maintained in accordance with NFPA 10 and the owner or managing operator must provided evidence of the required servicing to the marine inspector. Provide proof that portable extinguishers were internally examined or hydrostatic tested in accordance with NFPA 10.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 November 2018
Resolution: New portable extinguishers provided.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 4 September 2018 Resolved
To include position information in a distress alert, the VHF-DSC radio should be properly connected to a GPS Receiver or have a VHF-DSC marine radio with integral GPS. Vessel's VHF-DSC RADIO is not properly connected to a GPS received.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 November 2018
Resolution: GPS signal integraded into VHF radio.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 4 September 2018 Resolved
Each certificated small passenger vessels that operates in Sector Honolulu's inspection zone, that has a reduced manning endorsement connected to in-water activities, shall prove to the satisfaction of an attending Marine Inspector, that it meets or exceeds the provisions outlined in Sector Honolulu's Work Instruction 31. Provide required documentation and equipment listed in Work Instruction 31. Vessel must maintain the required manning levels specified on COI, one (1) master and one (1) deckhand, on board the vessel at all times when passengers have access to the vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 November 2018
Resolution: Verified compliance with Work Instruction 31.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 23 August 2018 Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have at the operating station, an audible alarm that sounds upon discharge. Repair/renew audible alarm.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 November 2018
Resolution: Audible alarm tested satisfactorily for pre-engineered fixed gas fire extinguisher.
Navigation › Piloting/Steering › Marine Charts
Issued 15 November 2017 Resolved
Provide an updated navigational chart for operating area. 46 CFR 184.420(a)
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 December 2017
Resolved 29 November 2017
Resolution: Vessel rep provided documentation of updated marine chart onboard vessel.
Navigation › Piloting/Steering › US Coast Pilot
Issued 15 November 2017 Resolved
Provide an up to date US Coast Pilot for operating area. 46 CFR 184.420(a)(2)
Action required: 705 - Other - as specified
Due 6 December 2017
Resolved 29 November 2017
Resolution: Vessel rep provided documentation of updated US Coast Pilot onboard vessel.
Stability › Watertight Integrity › General
Issued 12 January 2010 Resolved
1. Provide attachments for hatch covers in accordance with 46CFR179.360(b).
Due 12 February 2010
Resolved 5 February 2010
Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 24 February 2007 Resolved
Provide proof of compliance with the Drug and Alcohol Program In accordance with 46 CFR 16.
Due 10 March 2007
Resolved 13 March 2007
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 24 February 2007 Resolved
Replace missing deck rail chain at starboard embarkation point in accordance with 46 CFR 177.900.
Due 10 March 2007
Resolved 13 March 2007
Stability › Watertight Integrity › Deadlight Cover
Issued 24 February 2007 Resolved
Replace missing dead light cover latches (2) below deck in accordance with 46 CFR 179.
Due 10 March 2007
Resolved 13 March 2007
Engineering › Fuel Oil Service System › Tank
Issued 5 June 2006 Resolved
Verify satisfactory installation of new fuel tank IAW 46 CFR 182.440, 182.450, and 182.455.
Due 30 November 2006
Resolved 24 February 2007
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 13 February 2006 Resolved
Renew expired Safety Radio Telephony Certifiacte.
Action required: 705 - Other - as specified
Resolved 24 February 2007
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 13 February 2006 Resolved
Replace (5) structural longitudinal support members under swim step.
Action required: 705 - Other - as specified
Resolved 24 February 2007
Engineering › Diesel Engine (propulsion-direct drive) › Bearing
Issued 13 February 2006 Resolved
Replace worn cutless bearings.
Action required: 705 - Other - as specified
Resolved 20 February 2006
Construction/Loadline › Structures › Superstructure
Issued 13 February 2006 Resolved
Replace missing plexiglass window on the main deck.
Action required: 705 - Other - as specified
Resolved 20 February 2006
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 13 February 2006 Resolved
Replace pitted fuel tank.
Action required: 705 - Other - as specified
Due 5 June 2006
Resolved 5 June 2006
Engineering › Fuel Oil Service System › Filter
Issued 24 September 2002 Resolved
Install valve or plug at primary fuel filter drain IAW 46 CFR 182.455.
Condition: Improper/Lack of Maintenance
Due 8 October 2002
Resolved 30 September 2002
Engineering › Fuel Oil Service System › Hose
Issued 24 September 2002 Resolved
Replace fuel and lube oil hoses to SAE J-1942 standards, IAW 46 CFR 182.720
Condition: Improper/Lack of Maintenance
Due 8 October 2002
Resolved 30 September 2002
Lifesaving
Issued 5 September 2000 Resolved
Provide second paddle for lifefloat in accordance with 46 CFR 185.604(g) and replace lifeline and pendants in accordance with 46 CFR 180.175(f) and 46 CFR 160.010-8. _x001C_
Condition: Unknown
Due 13 September 2000
Resolved 5 October 2000
Electrical
Issued 5 September 2000 Resolved
Repair or replace light fixture in main seating area in accordance with 46 CFR 18.01-5.
Condition: Unknown
Due 13 September 2000
Resolved 5 October 2000
Fire Fighting
Issued 12 November 1999 Resolved
Completely seal bulkhead penetrations leading from/to the engine compartment to create a vapor tight seal for the fixed CO2 fire extinguishing system iaw 46CFR182.465.
Condition: Unknown
Due 12 November 1999
Resolved 12 November 1999
Fire Fighting
Issued 19 October 1999 Resolved
Provide servicing of portable fire extinguishers in accordance with 46 CFR 176.810 (b).
Condition: Unknown
Due 17 November 1999
Resolved 17 November 1999
Documentation
Issued 19 October 1999 Resolved
Provide proof of a current Certificate of Documentation in accordance 46 CFR 67.163.
Condition: Unknown
Due 17 November 1999
Resolved 17 November 1999
Documentation
Issued 19 October 1999 Resolved
Provide proof of an approved drug and alcohol program in accordance with 46CFR 16.
Condition: Unknown
Due 17 November 1999
Resolved 17 November 1999
Fire Fighting
Issued 19 October 1999 Resolved
Install a fixed firefighting system in the machinery space in accordance with 46 CFR 181.400.
Condition: Unknown
Due 17 November 1999
Resolved 17 November 1999
Engineering
Issued 5 September 1997 Resolved
INSTALL 30x30 CORROSION RESISTANT FLAME SCREEN IN FUEL TANK VENT.
Condition: Unknown
Due 5 September 1997
Resolved 5 September 1997
Lifesaving
Issued 5 September 1997 Resolved
MAKE REPAIRS TO CRACKS ON LIFE FLOAT AS PER MANUFACTURER RECOMMENDATION.
Condition: Unknown
Due 5 September 1997
Resolved 5 September 1997
Engineering
Issued 5 September 1997 Resolved
RENEW FUEL TANK MOUNTING BOLTS DURING VESSELS NEXT SCHEDULED DRYDOCK.
Condition: Unknown
Due 5 September 1997
Resolved 5 September 1997
Lifesaving
Issued 5 September 1997 Resolved
VESSEL RESTRICTED TO NOT MORE THAN 3 NM FROM SHORE UNTIL CATEGORY 1, _x001C_ 406 MHZ EPIRB IS INSTALLED.
Condition: Unknown
Due 5 September 1997
Resolved 5 September 1997
Documentation
Issued 5 September 1997 Resolved
PROVIDE EVIDENCE OF VALID FCC OPERATOR PERMIT.
Condition: Unknown
Due 5 September 1997
Resolved 5 September 1997
Accommodation/Occupational Safety
Issued 27 October 1995 Resolved
Provide label at Marine Sanitation Device through hull discharge valve stating not to open within three miles from land.
Condition: Unknown
Due 13 December 1995
Resolved 13 December 1995
Electrical
Issued 27 October 1995 Resolved
Properly secure electrical transformer located in the forward compartment.
Condition: Unknown
Due 27 October 1995
Resolved 27 October 1995
Construction/Loadline
Issued 27 October 1995 Resolved
Properly secure with a metallic fitting through hull fittings in engine room, 2 port, 1 starboard.
Condition: Unknown
Due 13 December 1995
Resolved 13 December 1995
Documentation
Issued 27 October 1995 Resolved
Provide documenatation indicating Employee Assistance Training for supervisors and crew; to include date, subject, place, attendees, and length of training.
Condition: Unknown
Due 13 December 1995
Resolved 13 December 1995
Navigation
Issued 27 October 1995 Resolved
For night dive operations, provide three all-round lights in a vertical line where they can best be seen. The highest and lowest of these lights shall be red and the middle light shall be white.
Condition: Unknown
Due 13 December 1995
Resolved 13 December 1995
Documentation
Issued 27 October 1995 Resolved
Provide a copy of the vessel's preventive maintenance schedule (PMS).
Condition: Unknown
Due 13 December 1995
Resolved 13 December 1995
Construction/Loadline
Issued 27 October 1995 Resolved
Make watertight all main deck access hatches (4), perform watertight hose test.
Condition: Unknown
Due 13 December 1995
Resolved 13 December 1995
Lifesaving
Issued 3 September 1992 Resolved
PROPERLY SECURE THE PAINTER STORAGE CAN FOR THE LIFE FLOAT.
Condition: Unknown
Due 3 September 1992
Resolved 3 September 1992
Construction/Loadline
Issued 3 September 1992 Resolved
PROVIDE SECURING DEVICES FOR ALL WEATHER DECK HATCH COVERS.
Condition: Unknown
Due 3 September 1992
Resolved 3 September 1992
Construction/Loadline
Issued 3 September 1992 Resolved
PROVIDE WATER TIGHT COAMING 6 INCHES IN HEIGHT FOR THE ACCESS OPENING INTO THE FORWARD CABIN.
Condition: Unknown
Due 3 September 1992
Resolved 3 September 1992
Lifesaving
Issued 3 September 1992 Resolved
PROVIDE PENDANTS FOR LIFE FLOATS 18 INCHES APART OF 1/4" LINE, 12 FEET LONGAND SECURED IN THE MIDDLE. THE LINE MUST BE ULTRAVIOLET LIGHT RESISTANT.
Condition: Unknown
Due 3 September 1992
Resolved 3 September 1992
Construction/Loadline
Issued 26 March 1992 Resolved
PROVIDE PROOF THAT VESSEL IS CONSTRUCTED OF FIRE RETARDANT RESIN OR PROVIDEFIXED FIRE EXTINQUISHING SYSTEMS IN ACCORDANCE WITH 46 CFR 181.20 FOR THE FUEL TANK AND MACHINERY COMPARTMENTS. IF A FIXED HALON SYSTEM IS PROVIDED,IT MUST ALSO HAVE A MEANS TO AUTOMATICALLY SECURE THE ENGINES.
Condition: Unknown
Due 26 March 1992
Resolved 26 March 1992
Lifesaving
Issued 9 September 1991 Resolved
PROVIDE PADDLES AND PROPERLT MARK THEM FOR THE LIFE FLOAT.
Condition: Unknown
Due 9 September 1991
Resolved 9 September 1991
Electrical
Issued 9 September 1991 Resolved
PROVIDE PROPER EMERGENCY LIGHT.
Condition: Unknown
Due 9 September 1991
Resolved 9 September 1991
Navigation
Issued 9 September 1991 Resolved
REPLACE MISSING COMPASS LIGHT BULB.
Condition: Unknown
Due 9 September 1991
Resolved 9 September 1991
Construction/Loadline
Issued 9 September 1991 Resolved
REATTACH THE PARTED DECK DRAIN LINE LOCATED IN THE ENGINE SPACE
Condition: Unknown
Due 9 September 1991
Resolved 9 September 1991
Electrical
Issued 9 September 1991 Resolved
DRAIN BOTH BATTERY BOXES OF STANDING WATER.
Condition: Unknown
Due 9 September 1991
Resolved 9 September 1991
Navigation
Issued 9 September 1991 Resolved
RENEW COTTER PIN IN HYDRAULIC ARM LINKAGE TO RUDDER.
Condition: Unknown
Due 9 September 1991
Resolved 9 September 1991
Navigation
Issued 9 September 1991 Resolved
PROVIDE PROPER NAVIGATION CHART OF OPERATION AREA.
Condition: Unknown
Due 9 September 1991
Resolved 9 September 1991
Engineering
Issued 9 September 1991 Resolved
TIGHTEN OR RENEW LEAKING PACKING GLAND.
Condition: Unknown
Due 9 September 1991
Resolved 9 September 1991
Lifesaving
Issued 9 September 1991 Resolved
RENEW THE BROKEN RETAINING RING ON TOP OF THE WATERLIGHT ATTACHED TO THE LIFE RING ON THE BRIDGE.
Condition: Unknown
Due 9 September 1991
Resolved 9 September 1991
Fire Fighting
Issued 9 September 1991 Resolved
PROPERLY MOUNT THE B-II FIRE EXTINGUISHER LOCATED ON THE OUTSIDE OF THE AFTER BULKHEAD TO THE CABIN.
Condition: Unknown
Due 9 September 1991
Resolved 9 September 1991
Lifesaving
Issued 9 September 1991 Resolved
RENEW THE EMERGENCY CHECK OFF LIST, AND TAILOR IT TO VESSEL.
Condition: Unknown
Due 9 September 1991
Resolved 9 September 1991
Fire Fighting
Issued 9 September 1991 Resolved
RENEW THE WORN HOSE ON THE HAND BILGE/FIRE PUMP.
Condition: Unknown
Due 9 September 1991
Resolved 9 September 1991
Engineering
Issued 9 September 1991 Resolved
TIGHTEN OR RENEW THE LEAKING FUEL LINE FITTING ON THE PORT SIDE IN THE ENGINE SPACE.
Condition: Unknown
Due 9 September 1991
Resolved 9 September 1991
Electrical
Issued 9 September 1991 Resolved
REATTACH THE LOOSE GROUND WIRE ON PORT SIDE OF ENGINE IN ENGINE SPACE.
Condition: Unknown
Due 9 September 1991
Resolved 9 September 1991
Construction/Loadline
Issued 20 February 1991 Resolved
REPLACE THE MISSING DOG NUTS ON THE PORT AND STARBOARD PORTHOLES.
Condition: Unknown
Due 20 February 1991
Resolved 20 February 1991
Lifesaving
Issued 12 September 1989 Resolved
PROVIDE A COAST GUARD APPROVED 24 INCH DIAMETER RING BOUY AS REQUIRED IN 46 CODE OF FEDERAL REGULATIONS PART 180.30-5(A). THIS SHALL BE COMPLETED NO LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Documentation
Issued 12 September 1989 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Electrical
Issued 12 September 1989 Resolved
PROVIDE MEANS OF VENTILATION FOR BATTERY BOXES AND SOME MEANS OF DRAINING STANDING WATER OUT.
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Navigation
Issued 12 September 1989 Resolved
CLEAN SIDELIGHT COVERS TO MAKE NAVIGATION LIGHTS VISIBLE.
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Lifesaving
Issued 12 September 1989 Resolved
RENEW BATTERIES FOR WATER LIGHTS ON RING BOUY AND LIFEFLOAT.
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Documentation
Issued 9 September 1988 Resolved
POST THE VESSEL'S CERTIFICATE OF INSPECTION IN A CONSPICUOUS PLACE UNDER GLASS OR OTHER TRANSPARENT MATERIAL.
Condition: Unknown
Due 9 September 1988
Resolved 9 September 1988
Documentation
Issued 9 September 1988 Resolved
POST THE EMERGENCY CHECKOFF LIST IN A CONSPICUOUS PLACE ACCESSIBLE TO THE CREW AND PASSENGERS.
Condition: Unknown
Due 9 September 1988
Resolved 9 September 1988
Lifesaving
Issued 9 September 1988 Resolved
PROVIDE TWO PADDLES AT LEAST FOUR FEET LONG FOR THE LIFE FLOAT.
Condition: Unknown
Due 9 September 1988
Resolved 9 September 1988
Lifesaving
Issued 9 September 1988 Resolved
PROVIDE SUITABLE TRICING LINES FOR THE VESSEL'S LIFE FLOAT.
Condition: Unknown
Due 9 September 1988
Resolved 9 September 1988
Lifesaving
Issued 9 September 1988 Resolved
PROVIDE A FLOAT FREE LINK FOR THE VESSEL'S LIFE FLOAT CERTIFIED TO MEET 46 CFR 160.073 AT PROPER STRENGTH FOR A 15 PERSON LIFE FLOAT.
Condition: Unknown
Due 9 September 1988
Resolved 9 September 1988
Navigation
Issued 9 September 1988 Resolved
PLACE THE COMPASS LIGHT IN OPERATING CONDITION PRIOR TO OPERATING THE VESSEL AT NIGHT.
Condition: Unknown
Due 9 September 1988
Resolved 9 September 1988
Engineering
Issued 9 September 1988 Resolved
PROVIDE A SUITABLE GROUND CONNECTION BETWEEN THE FUEL TANK AND THE DECK FITTING.
Condition: Unknown
Due 9 September 1988
Resolved 9 September 1988
Engineering
Issued 9 September 1988 Resolved
PROVIDE A FLAME CUP FOR THE RACOR FUEL FILTER.
Condition: Unknown
Due 9 September 1988
Resolved 9 September 1988
Engineering
Issued 9 September 1988 Resolved
RENEW THE SHAFT PACKING IN THE STUFFING BOX.
Condition: Unknown
Due 9 September 1988
Resolved 9 September 1988
Lifesaving
Issued 9 September 1988 Resolved
MARK THE LIFE FLOAT CAPACITY WITH LETTERS AND NUMBERS AT LEAST 1 1/2 INCHESHIGH.
Condition: Unknown
Due 9 September 1988
Resolved 9 September 1988

Casualty record · 2

16 October 2019Routine · role: Involved in a Marine Casualty · 1 injured · activity 6841600
20 March 2025Routine · role: Involved in a Marine Casualty · activity 8114013
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.