MAURY USCG vessel records Sign in
← All vessels

ANTARES

ANTARES is a 1984 tank ship. The Coast Guard has recorded 53 inspections since 1984, most recently in May 2007, along with 24 deficiencies — 1 with no resolution recorded — and 6 operational controls, 1 with no removal date recorded.

Records from 1984 to 2007. Most recent: operational control imposed, 12 May 2007.

Built
1984
Last inspected
11 May 2007
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

8316572 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
235300
Flag
BAHAMAS, THE
—
Maury page id
psix-235300

Inspections, by type

…with no type recorded36
Years with a record 19 calendar years (1984–2007)
The 53 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it11572 - Convention (Subpart B), Net Ton
11572 - Regulatory (Subpart C or D), Net Ton
16820 - Convention (Subpart B), Gross Ton
16820 - Regulatory (Subpart C or D), Gross Ton
36969 - Displacement, Ton
29954 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 53

11 May 2007 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2928227
31 January 2007 Ballast Water Examination · MARPOL Annex I Examination · COC-CHEM Annual · ISPS II Exam
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2860323
1 September 2005 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2480846
20 August 2005 COC-CHEM Renew · MARPOL Annex I Examination · MARPOL Annex II Examination · ISPS II Exam · Deficiency Check · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2468194
19 August 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2468338
15 August 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2464431
2 August 2003 Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1868114
17 June 2002 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1631919
17 May 2002 Certificate of Compliance
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1616354
27 September 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 294186
13 March 2001 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1072195
26 February 2000 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 275101
26 February 2000 Letter of Compliance (Initial/Renewal)
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 815771
8 January 1999 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 424282
13 May 1998 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 114315
17 April 1998 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 506440
29 March 1998 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 480065
11 April 1997 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 402164
4 April 1997 Letter of Compliance (Initial/Renewal)
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1102275
10 December 1994 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 437649
6 November 1994 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 371982
6 November 1994 Letter of Compliance (Initial/Renewal) · MARPOL Annex I Examination · MARPOL Annex II Examination · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 871712
10 November 1993 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 960396
20 July 1993 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 512417
23 June 1993 Administrative
Administrative · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 842747
8 June 1993 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 840522
21 February 1993 MARPOL Annex I Examination · MARPOL Annex V Examination · Certificate of Compliance
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1389613
9 November 1992 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 354183
29 August 1992 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 507948
20 July 1992 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 351975
11 May 1992 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 350648
22 April 1992 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 666596
13 April 1992 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 350020
13 April 1992 Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1433932
3 October 1991 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 666602
24 September 1991 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 508613
12 August 1991 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 934684
1 March 1991 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 342195
1 March 1991 Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1223070
5 March 1990 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 921013
15 December 1989 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 493174
6 March 1989 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 497887
6 March 1989 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 891422
17 September 1988 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 325675
17 September 1988 Certificate of Compliance
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1042901
4 May 1986 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 438910
16 February 1986 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 990647
18 November 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 451997
15 November 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 305373
15 November 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 996332
9 July 1985 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 480136
22 January 1985 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 445299
24 August 1984 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 297754

Deficiency record · 24

Navigation › Piloting/Steering › Gyro Compass
Issued 23 January 2007 No resolution recorded
Prove proper operation of Gyro Compass, an LOD has been issued.
Action required: 17 - Rectify deficiencies prior to departure
Resolution: Entered in error.
Navigation › Piloting/Steering › Magnetic Compass
Issued 23 January 2007 Resolved
Magnetic compass inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 January 2007
Resolution: Miscommunication between the vessel''s Master and the local agent. Master was requesting a technician to carry out magnetic compass deviation for outbound transit. During inspection of navigation safety equipment, magnetic compass was operating properly
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 2 August 2003 Resolved
Prove proper operation of ODME prior to using unit. LEGACY COMPONENT DESC: Cargo Monitor/Control System
Action required: 705 - Other - as specified
Resolved 20 August 2005
Resolution: Cleared by NEWMS boarding team 20 Aug 05.
Lifesaving › Inflatable Liferafts › Approval
Issued 2 August 2003 Resolved
Safety equipment certificate states 2- 30 person liferafts are required, but there are only 2-25 person on board. Either add liferatfs, or ammend cert to reflect actual number required.
Action required: 705 - Other - as specified
Resolved 20 August 2005
Resolution: Cleared by NEWMS boarding team 20 Aug 05.
Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 2 August 2003 Resolved
Cargo pumproom fixed gas detection shows "fault." Prove proper operation of system
Action required: 705 - Other - as specified
Resolved 20 August 2005
Resolution: Cleared by NEWMS boarding team 20 Aug 05.
Deck/Cargo › Inert Gas System
Issued 17 May 2002 Resolved
Provide span gas (8%) in accordance with calibration procedures set forth in the vessel's IGS Operations Manual IAW SOLAS 74, Regulation 62.18 LEGACY COMPONENT DESC: Oxygen Analyzer
Due 1 June 2002
Resolved 17 June 2002
Resolution: Received proof of receipt of span gas (8%).
Lifesaving
Issued 27 September 2001 Resolved
INSUFFICIENT NUMBER OF RATIONS IN LIFEBOATS. MUST PROVIDE SUFFICIENT RATIONS BEFORE DEPARTING. SOLAS CHAPTER 3 REGULATION 41.8.12
Condition: Unknown
Due 28 September 2001
Resolved 1 October 2001
Lifesaving
Issued 27 September 2001 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 28 September 2001
Resolved 1 October 2001
Deck/Cargo
Issued 26 February 2000 Resolved
REPAIR CARGO LEAKS AT FOLLOWING LOCATIONS: #4C BUTTERWORTH, 1C BUTTERWORTH.
Condition: Unknown
Due 27 February 2000
Resolved 22 March 2000
Fire Fighting
Issued 26 February 2000 Resolved
CORRECT LOCATION OF INT. SHORE CONNECTION ON ALL FIRE PLANS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 September 2000
Resolved 14 September 2000
Fire Fighting
Issued 26 February 2000 Resolved
SERVICE ALL PORTABLE FIRE EXTINGUISHERS PRIOR TO DEPARTURE.
Condition: Unknown
Due 27 February 2000
Resolved 22 March 2000
Deck/Cargo
Issued 26 February 2000 Resolved
REPAIR IGS LEAKS AT FOLLOWING LOCATIONS: IG MAIN ABOVE 3C CARGO TANK, HOLEIN IG SPOOL PIECE IN IG ISOLATION VALVE.
Condition: Unknown
Due 27 February 2000
Resolved 22 March 2000
Deck/Cargo
Issued 26 February 2000 Resolved
REPAIR THE FOLLOWING P/V VALVES: 3P P/V HIGH PRESS. SIDE AND HALDLE, CARGOP/V IS LEAKING PRESS OUT.
Condition: Unknown
Due 27 February 2000
Resolved 22 March 2000
Fire Fighting
Issued 26 February 2000 Resolved
REPAIR EMERGENCY FIRE PUMP EXHAUST LEAK FROM DRAW LINE.
Condition: Unknown
Due 27 February 2000
Resolved 22 March 2000
Deck/Cargo
Issued 26 February 2000 Resolved
PROVE ADEQUATE VAPOR SPACE O2 CONTENT.
Condition: Unknown
Due 27 February 2000
Resolved 22 March 2000
Deck/Cargo
Issued 26 February 2000 Resolved
PROVE PROPER OPERATION OF CARGO PUMP EMERGENCY SHUT DOWNS.
Condition: Unknown
Due 27 February 2000
Resolved 22 March 2000
Documentation
Issued 8 January 1999 Resolved
PROVIDE COPY OF MASTER'S ISM CODE NON-CONFORMITY REPORT TO DESIGNATED PERSON REGARDING DEFICIENCIES OF BOTH LIFEBOATS ISSUED THIS DATE PRIOR TO DEPARTURE FROM THE PORT OF BOSTON.
Condition: Unknown
Due 9 January 1999
Resolved 11 January 1999
Lifesaving
Issued 8 January 1999 Resolved
PROVIDE CLASS SOCIETY REPORT OF PROPER OPERATION OF BOTH PORT AND STBD LIFEBOAT ENGINES PRIOR TO DEPARTING THE PORT OF BOSTON.
Condition: Unknown
Due 9 January 1999
Resolved 11 January 1999
Documentation
Issued 13 April 1992 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 12 May 1992
Resolved 12 May 1992
Deck/Cargo
Issued 1 March 1991 Resolved
PRIOR TO CARGO OPERATIONS, NEXT U.S. PORT, ENSURE THAT:_x001C_ A) OXYGEN/PRESSURE RECORDERS OPERATE PROPERLY ON I.G.S._x001C_ B) HIGH OXYGEN/LOW PRESSURE ALARMS OPERATE AS REQUIRED._x001C_ C) AUTOMATIC SHUTDOWN VALVE OPERATES ON I.G.S. _x001C_
Condition: Unknown
Due 1 March 1991
Resolved 1 March 1991
Documentation
Issued 17 September 1988 Resolved
OIL TRANSFER PROCEDURES DESCRIBED IN 33CFR155.750 AND REQUIRED BY 33CFR155.720 NOT COMPLETE. MISSING WERE PROCEDURES FOR TENDING MOORINGS, FOR TOPPING OFF TANKS, FOR MMAKING NOTIFICATION IN THE EVENT OF A RELEASE OR DISCHARGE, AND A LIST OF PRODUCTES TRANSFERRED.
Condition: Unknown
Due 17 September 1988
Resolved 17 September 1988
Deck/Cargo
Issued 17 September 1988 Resolved
MECHANICAL MEANS OF CLOSING CONTAINMENT NOT AVAILABLE AS REQUIRED BY 33CFR155.310.
Condition: Unknown
Due 17 September 1988
Resolved 17 September 1988
Navigation
Issued 15 November 1985 Resolved
LIGHT LIST, USCG VOLUME 3, DATED 1985 WAS UNCORRECTED. NO FOREIGN EQUIVALENTS WERE AVAILABLE FOR THE ABOVE NOTED DISCREPANCIES.
Condition: Unknown
Due 17 November 1985
Resolved 15 November 1985
Deck/Cargo
Issued 15 November 1985 Resolved
PROVIDE TOXIC GAS DETECTORS FOR ALL CHEMICALS LISTED ON IMO CHEMICAL CERTIFICATE. VESSEL IS RESTRICTED FROM CARRYING THESE CHEMICALS IN U.S. WATERS UNTIL DETECTORS ARE PROVIDED.
Condition: Unknown
Due 15 November 1985
Resolved 15 November 1985

Ownership record