MAURY USCG vessel records
← All vessels

MOBILE

MOBILE is a 1983 towing vessel. The Coast Guard has recorded 32 inspections since 1984, most recently in December 2010, along with 24 deficiencies and 2 casualty investigations between 2008 and 2010.

Records from 1984 to 2010. Most recent: inspection, 31 December 2010.

Built
1983
Last inspected
31 December 2010
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 31 December 2010
…with no type recorded15
Operational controls None recorded without a removal date
Years with a record 16 calendar years (1984–2010)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8001206
235301
Flag
COMOROS
Maury page id
psix-235301

Documentation record

Tonnage as PSIX records it1515 - Regulatory (Subpart C or D), Gross Ton
2438 - Convention (Subpart B), Gross Ton
1030 - Regulatory (Subpart C or D), Net Ton
731 - Convention (Subpart B), Net Ton
820 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

JAMES MCALLISTER Towing Vessel · MISLE 176437 · 16 March 2008 · activity 3183844SIGNET CHALLENGER Towing Vessel · MISLE 637868 · 16 March 2008 · activity 3183844VB 33 Tank Barge · MISLE 54395 · 18 May 1996 · activity 508536

Inspection history · 32

31 December 2010 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3921217
13 December 2010 Ballast Water Examination · PII Safety Exam · ISPS II Exam · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3909847
26 February 2009 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3424300
16 March 2008 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3183844
21 November 2002 Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1700814
10 August 2002 Administrative Inspection
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1659357
29 May 2001 Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1065063
2 November 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 53747
2 December 1996 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 24738
18 May 1996 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 508536
11 February 1994 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 853176
22 December 1992 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1135155
16 September 1992 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 955328
29 January 1992 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 955942
28 January 1992 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1254180
4 December 1991 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 944465
19 October 1991 COI Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1313709
29 November 1990 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 904949
5 October 1990 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 930388
4 November 1989 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 899438
3 October 1988 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1044718
12 September 1988 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1350331
27 August 1988 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1347872
15 November 1987 COI Inspection · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1018095
17 February 1987 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1312566
11 October 1985 Credit Drydock · COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1301136
9 May 1985 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1290663
27 April 1985 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 983643
26 April 1985 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 981294
22 February 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 977878
2 February 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 978864
22 August 1984 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1282761

Deficiency record · 24

Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 23 December 2010 Resolved
1400-Propulsion & Aux. Machinery-Conduct repairs to both SSG#1 and #2 and prove proper capability to carry and load share in both automatic and manual mode. SOLAS 74am I/11
Action required: 705 - Other - as specified
Due 23 December 2010
Resolved 29 December 2010
Resolution: Received, reviewed and accepted report from nominated surveyor attesting to the proper operation of the SGG''''s.
Engineering › Steering Gear System › Power Unit
Issued 23 December 2010 Resolved
0936-Conduct repair to in board P.T.O. pump on port hydraulic steering gear assembly. SOLAS 74am II/I-29
Action required: 705 - Other - as specified
Due 23 December 2010
Resolved 29 December 2010
Resolution: Received, reviewed and accepted report from nominated surveyor attesting to the proper repair to the P.T.O. pump on port hydraulic steering gear assembly.
Operations/Management › Drills/Instruction › Not Conducted
Issued 23 December 2010 Resolved
2540-Emergency preparedness-Conduct satisfactory SOLAS steering gear test. SOLAS 74am II/I-29
Action required: 705 - Other - as specified
Due 23 December 2010
Resolved 29 December 2010
Resolution: Received, reviewed and accepted report from nominated surveyor attesting to the crew conducting a satisfactory SOLAS steering gear test.
Communications › Internal Communications System › Sound-powered Telephone
Issued 23 December 2010 Resolved
2015-Demonstrate fixed communication between bridge and both steering flats. SOLAS 74am I/11
Action required: 705 - Other - as specified
Due 23 December 2010
Resolved 29 December 2010
Resolution: Received, reviewed and accepted report from nominated surveyor attesting to the proper operation of fixed communication between the bridge and steering gear flats.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 23 December 2010 Resolved
2199-Remove all waste oil from both tug and barge. MARPOL 73/78 Annex 1
Action required: 705 - Other - as specified
Due 23 December 2010
Resolved 29 December 2010
Resolution: Received, reviewed and accepted receipt for disposal of 9000 gallons of waste oil/sludge and water to shore side reception facility.
Operations/Management › Drills/Instruction › Fire
Issued 23 December 2010 Resolved
2540-Conduct satisfactory fire and abandonship drill. SOLAS 74am V
Action required: 705 - Other - as specified
Due 23 December 2010
Resolved 29 December 2010
Resolution: Received, reviewed and accepted report from nominated surveyor attesting to the crew conducting a satisfactory abandonship drill.
Engineering › Fuel Oil Service System › Hose
Issued 23 December 2010 Resolved
1400-Pressure test all service lines between tug and barge. SOLAS 74am I/11
Action required: 705 - Other - as specified
Due 23 December 2010
Resolved 29 December 2010
Resolution: Received, reviewed and accepted report from nominated surveyor attesting to the replacement of all service lines between tug and barge.
Engineering › Diesel Engine (propulsion-reduction gear) › Silencer (exhaust)
Issued 13 December 2010 Resolved
1400-Propulsion & Aux. Machinery. Conduct repairs to the failed exhaust silencer in the port stack. SOLAS 74am I/11
Action required: 705 - Other - as specified
Due 31 January 2011
Resolved 2 January 2011
Resolution: Received, reviewed and accepted report from nominated surveyor attesting to the temporary repair to the exhaust silencer.
Navigation
Issued 16 September 1992 Resolved
PROVIDE ABS REPORT FOR STARBOARD RUDDER REPAIR.
Condition: Unknown
Due 16 September 1992
Resolved 16 September 1992
Engineering
Issued 19 October 1991 Resolved
PROVIDE AN APPROVED AUTOMATION TEST PROCEDURE.
Condition: Unknown
Due 19 October 1991
Resolved 19 October 1991
Lifesaving
Issued 19 October 1991 Resolved
PROVIDE POSTERS AND SIGNS IN THE VICINITY OF SURVIVAL CRAFT AND THEIR LAUNCHING CONTROLS AS REQUIRED BY 74 SOLAS CH III REG. 9
Condition: Unknown
Due 19 October 1991
Resolved 19 October 1991
Documentation
Issued 19 October 1991 Resolved
PROVIDE COAST GUARD APPROVED PLANS FOR THE NEW AUTOMATION SYSTEM AND COMPLYWITH ALL COMMENTS PRETAINING TO THESE PLANS.
Condition: Unknown
Due 19 October 1991
Resolved 19 October 1991
Engineering
Issued 19 October 1991 Resolved
THE CHIEF ENGINEER IS TO PROVIDE A LETTER STATING THAT THE WASTE HEAT BOILER SAFETY VALVES WERE TESTED AFTER GETTING UNDER WAY AND DESCRIBING THEIR OPERATION.
Condition: Unknown
Due 6 December 1991
Resolved 6 December 1991
Fire Fighting
Issued 19 October 1991 Resolved
PROVIDE A TOTAL OF FOUR (4) FIREMANS OUTFITS AS REQUIRED BY 74 SOLAS CH. II-2 REG. 17.
Condition: Unknown
Due 19 October 1991
Resolved 19 October 1991
Electrical
Issued 19 October 1991 Resolved
PROVIDE A HIGH JACKET WATER TEMP. AND LOW LUBE OIL ALARM FOR THE EMERGENCY GENERATOR AS REQUIRED BY 46 CFR 112.50-1 (h)
Condition: Unknown
Due 19 October 1991
Resolved 19 October 1991
Fire Fighting
Issued 19 October 1991 Resolved
PROVIDE A TOTAL OF FOUR (4) PORTABLE FOAM APPLICATORS AS REQUIRED BY 74 SOLAS CH. II-2 REG. 61.8.
Condition: Unknown
Due 19 October 1991
Resolved 19 October 1991
Documentation
Issued 19 October 1991 Resolved
PROVIDE A TRAINING MANUAL FOR THE VESSEL AS REQUIRED BY 74 SOLAS CH. III REG. 18. THE CONTENTS OF THE TRAINING MANUAL ARE TO BE AS LISTED IN CH. IIIREG. 51. .
Condition: Unknown
Due 19 October 1991
Resolved 19 October 1991
Accommodation/Occupational Safety
Issued 27 August 1988 Resolved
REMOVE PAINT FROM FORWARD BOATSWAINS LOCKER AND STOW AS PROVIDED IN VESSELSPAINT LOCKER.
Condition: Unknown
Due 27 August 1988
Resolved 27 August 1988
Engineering
Issued 27 August 1988 Resolved
MAKE PERMANENT REPAIRS AND PROVE OPERATION OF THE THE OILY WATER SEPARATOR AND MONITOR IN THE STARBOARD ENGINE ROOM. ALL OILY MIXTURES SHALL BE RETAINED ON BOARD THE TUG OR THE BARGE AND THE VESSEL MAY NOT MAKE ANY FOREIGN VOYAGES UNTIL THE REQUIREMENTS IS CLEARED AND AN IOPP CERT. ISSUED.
Condition: Unknown
Due 27 August 1988
Resolved 27 August 1988
Engineering
Issued 26 April 1985 Resolved
MAKE PERMANENT REPAIRS TO "DONKEY BOILER" SDC 80003 WITH REGARD TO THE BRKCKWORK AND DAMAGED FIREBOX CASING.(A) THE AFT END OF THE BILER. THESE REPAIRS ARE TO BE COMPLETED PRIOR TO THE VESSEL'S DEPARTURE FROM GALVESTON BAY OR IN ANY CASE WITHIN SEVEN (7) DAYS FROM THIS DATE
Condition: Unknown
Due 26 April 1985
Resolved 26 April 1985
Engineering
Issued 26 April 1985 Resolved
MAKE PERMANENT REPAIRS TO STACK GAS LEAKS IN THE HEATING BOILER ABOARD THE BARGE (SERIAL MOB 810) WITHIN FOURTEEN (14) DAYS FROM THIS DATE.
Condition: Unknown
Due 26 April 1985
Resolved 26 April 1985
Accommodation/Occupational Safety
Issued 22 August 1984 Resolved
PROVIDE A SECOND EMERGENCY VENTILATION REMOTE SHUTDOWN IN THE VICINITY OF THE WHEELHOUSE AS REQUIRED BY 46 CFR 111.80-10.
Condition: Unknown
Due 22 August 1984
Resolved 22 August 1984
Accommodation/Occupational Safety
Issued 22 August 1984 Resolved
PROVIDE AN EMERGENCY SHUTDOWN FOR THE MOTORS IN THE QUARTERS AREA AIR CONDITIONING. INCLUDE THIS REMOTE STOP WITH THE EXISTING EMERGENCY SHUTDOWNIN THE ECC ROOM AND IN THE VICINITY OF THE WHEELHOUSE AS REQUIRED BY 46 CFR 111.80-10
Condition: Unknown
Due 22 August 1984
Resolved 22 August 1984
Deck/Cargo
Issued 22 August 1984 Resolved
ALL BUTTERFLY VALVES IN THE INERT GAS SYSTEM, CARGO TANK FRESH AIR PURGE SYSTEM AND CARGO TANK SLOPS PIPING ARE TO BE OPENED FOR U.S. COAST GUARD INSPECTION NOT LATER THAN 22 FEBRUARY 1985. ANY SIGN OF FAILURE WILL REQ. REPLACEMENT OF ALL SUCH VALVES IN AFFECTED SYSTEM.
Condition: Unknown
Due 22 August 1984
Resolved 22 August 1984

Casualty record · 2

16 March 2008Routine · role: Involved in a Marine Casualty · activity 3183844
31 December 2010Routine · role: Involved in a Marine Casualty · activity 3921217
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.