BULK CAJUN
BULK CAJUN is a 1984 freight ship. The Coast Guard has recorded 39 inspections since 1984, most recently in October 2014, along with 19 deficiencies and 8 operational controls.
Records from 1984 to 2014. Most recent: operational control imposed, 23 October 2014.
- Built
- 1984
- Last inspected
- 23 October 2014
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 19 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8200450 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3FET8
235363
Flag
PANAMA
—
Maury page id
psix-235363
Inspections, by type
…with no type recorded30
Years with a record
24 calendar years (1984–2014)
The 39 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it36958 - Convention (Subpart B), Gross Ton
20723 - Convention (Subpart B), Net Ton
68705 - Dead Weight, Ton
78378 - Displacement, Ton
20723 - Convention (Subpart B), Net Ton
68705 - Dead Weight, Ton
78378 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 39
23 October 2014
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5008016
25 March 2014
Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4817247
7 March 2014
Ballast Water Examination · ISPS III Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4805633
25 February 2011
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3952570
23 February 2011
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3954990
25 October 2010
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3868379
4 January 2010
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3658065
4 January 2010
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3658474
4 January 2010
Type not recorded
No type recorded · USCGC PELICAN (WPB 87327) · USCG Heartland District (CGD-H) · Activity 3670956
1 July 2009
MARPOL Annex I Examination · MARPOL Annex V Examination · MARPOL Annex VI Survey · PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3514398
21 December 2008
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3384598
22 June 2008
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3243957
20 June 2008
Type not recorded
No type recorded · Station Little Creek · USCG East District (CGD-E) · Activity 3245376
3 May 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2348808
23 November 2004
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2246710
16 November 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2243237
26 September 2003
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1913753
5 August 2003
Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1867681
30 July 2003
Type not recorded
No type recorded · GROUP SEATTLE · USCG Northwest District (CGD-NW) · Activity 1861969
28 May 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1804381
26 May 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1802193
1 October 2001
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 294140
4 April 2000
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 276295
1 October 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 421009
26 February 1998
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 412934
11 March 1997
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 401196
16 December 1995
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 385750
6 July 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 380439
14 March 1994
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 365229
5 January 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 355476
5 January 1992
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 355632
17 August 1991
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 345382
17 November 1990
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 340349
22 August 1989
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 332159
6 March 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 321670
20 April 1987
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 315557
23 July 1986
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 462445
7 November 1985
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 304998
27 August 1984
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 297755
Deficiency record · 19
Navigation › Collision/Grounding Avoidance › Radar
Issued 23 October 2014
Resolved
The X-Band Radar was reported as not operational.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 7 March 2014
Resolved
0750-Fire prevention-The ship and its equip shall be maintained to the present regs to ensure that the ship will remain fit to proceed to sea without danger to the ship or person on board. PSCO observed the permanent fire retardant packing material around the elec lines under the elec switchboard in the ECR has been removed. Provide clarification form certificate issuing authority-SOLAS 74 am I/11
Electrical › Electrical Distribution System (service) › Junction Box
Issued 7 March 2014
Resolved
0950-Electric equipment in general-The ship and its equip shall be maintained to the present regs to ensure that the ship will remain fit to proceed to sea without danger to the ship or person on board. PSCO observed severe wastage on the electrical conduit between cargo holds 6 & 7. Provide documentation from certificate issuing authority to the integrity of electrical conduit-SOLAS 74 am I/11
Construction/Loadline › Structures › Door
Issued 7 March 2014
Resolved
1270-Doors-All access openings in bulkheads at ends of enclosed superstructures shall be fitted with doors of steel or equivalent material and weather tight when closed. PSCO observed severe wastage and excessive rust preventing closure of multiple weathertight doors on the superstructure. Provide documentation from certificate issuing authority to weathertight integrity of doors-ICLL Ch. II/10
Navigation › Collision/Grounding Avoidance › Radar
Issued 23 February 2011
Resolved
One of the two required radars was reported as non operational.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 1 July 2009
Resolved
High voltage junction box had significant deterioration at the weld where the pipe penetrates the box.
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 1 July 2009
Resolved
The hydraulic power pack tank level indicator and fill had temporary repairs; significant leaking.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 1 July 2009
Resolved
M/E jacket water cooler, on the inlet side had a temporary patch.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 1 July 2009
Resolved
The G.E.F.W. cooler to the GSG had a temporary patch on the bell housing.
Engineering › Lubricating Oil Storage/Transfer System › Piping
Issued 1 July 2009
Resolved
The cylinder oil storage tank transfer pump to the cylinder oil day tank has been removed. Crew was using a portable pump and a clear hose to transfer from one pump to the other.
Construction/Loadline › Markings
Issued 5 August 2003
Resolved
Loadline markings shall be welded permanently, and marked on the side of the ship in white or yellow color. LEGACY COMPONENT DESC: Load Line Mark
Lifesaving › Buoyant Smoke Signals
Issued 5 August 2003
Resolved
Provide two operational smoke distress signals.
Lifesaving › Lifeboat
Issued 5 August 2003
Resolved
Repair safety line on starboard lifeboat to sufficient length. LEGACY COMPONENT DESC: Lifeline (becketed)
Navigation
Issued 5 January 1992
Resolved
U.S. CHARTS, OF THE AREA TO BE TRANSITED, WERE NOT ON BOARD. MISSING # 11327, 11328 & 11329.
Navigation
Issued 5 January 1992
Resolved
U.S. TIDE TABLES WERE OUTDATED.
Navigation
Issued 5 January 1992
Resolved
U.S. TIDAL CURRENT TABLES WERE NOT ON BOARD.
Navigation
Issued 5 January 1992
Resolved
NO INLAND NAVIGATION RULES ON BOARD.
Documentation
Issued 6 March 1988
Resolved
VSL FAILED TO HAVE COMPLETE OIL TRANSFER PROCEDURES
Navigation
Issued 7 November 1985
Resolved
VESSEL COAST PILOT & LIGHT LIST WERE NOT CURRENTLY CORRECTED.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.