MAURY USCG vessel records Sign in
← All vessels

CAPE MAIL

CAPE MAIL is a 1984 freight ship. The Coast Guard has recorded 66 inspections since 1984, most recently in December 2020, along with 73 deficiencies and 5 operational controls.

Records from 1984 to 2020. Most recent: inspection, 12 December 2020.

Built
1984
Last inspected
12 December 2020
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8401107 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
236277
Flag
VANUATU
338636000, 368333000 (licence lapsed)
Maury page id
psix-236277

Inspections, by type

…with no type recorded13
Years with a record 28 calendar years (1984–2020)
The 66 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it385 - Regulatory (Subpart C or D), Gross Ton
858 - Convention (Subpart B), Gross Ton
262 - Regulatory (Subpart C or D), Net Ton
257 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDD9049MMSI 368333000 · cancelled · compulsorily equipped · granted 3 August 2007, cancelled 4 April 2016 · licensed under a name not among this hull’s recorded names (not shown)
WCW9249MMSI 338636000 · expired · voluntarily equipped · granted 4 October 2006, cancelled 31 December 2016 · licensed under a name not among this hull’s recorded names (not shown)
WSQ4014MMSI not assigned · expired · compulsorily equipped · granted 17 August 1995, cancelled 7 January 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 66

12 December 2020 PSC A · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7110043
8 June 2020 PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6969004
19 April 2020 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6941041
9 October 2019 PII Safety Exam · ISPS III Exam · CCSSC Examination · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6829972
8 April 2019 ISPS III Exam · CCSSC Examination · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6656736
14 October 2018 Ballast Water Examination · PI Safety Exam · ISPS III Exam · CCSSC Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6560832
1 May 2018 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6403341
11 April 2018 Ballast Water Examination · CCSSC Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6389356
24 October 2017 Ballast Water Examination · CCSSC Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6280470
10 April 2017 Ballast Water Examination · ISPS II Exam · CCSSC Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6121059
17 March 2017 CCSSC Examination · Deficiency Check · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6105480
23 December 2016 Administrative Inspection · In-Service Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6061683
31 October 2016 ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6032280
12 September 2016 NPV Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5996608
4 May 2009 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3467285
11 December 2008 Examination of Repairs · Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3377079
1 October 2007 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3073850
11 October 2006 Examination of Repairs · Deficiency Check · Hull Examination · Cargo Tank Internal · Internal Structural Exam · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2798150
15 February 2006 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2585554
25 November 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2541610
12 September 2005 COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2490629
21 July 2005 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2434662
8 September 2004 Annual Inspection · MTSA Verification
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2200219
18 June 2004 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2102673
14 May 2004 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2078056
11 December 2003 Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1962354
10 June 2003 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1813834
19 November 2002 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1707354
12 October 2001 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1401577
13 September 2000 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1361701
22 November 1999 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1365455
27 September 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1037632
10 December 1998 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1381394
25 September 1998 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1436121
31 August 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1409955
13 November 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1121684
30 October 1997 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1436000
27 September 1996 Hull Examination · COI Inspection · Inclining Experiment
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1428686
7 May 1996 Permit to Proceed
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1363637
21 April 1996 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1085806
1 July 1995 Permit to Proceed
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1385493
7 February 1994 Permit to Proceed
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1442099
21 May 1992 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1264540
7 May 1992 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 951847
13 March 1992 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 953439
7 January 1992 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 961431
6 November 1990 COI Inspection · Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 932844
18 October 1990 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1243218
28 September 1989 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1335300
21 August 1989 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1204524
9 November 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 893024
28 September 1988 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1196214
28 October 1987 Hull Examination · Re-Inspection
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1332718
6 July 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1012913
29 June 1987 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1317097
29 May 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1025826
8 May 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1334399
31 March 1987 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1314200
25 November 1986 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1332856
12 September 1986 Hull Examination · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1319615
5 August 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1296761
27 June 1986 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 996157
2 June 1986 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1294488
2 April 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1304569
28 January 1986 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1293399
7 September 1984 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 975672

Deficiency record · 73

11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 12 December 2020 Resolved
Rescue boats shall be stowed in a state of continuous readiness in not more than 5 min. Rescue boat davit wire rope was found outside of the sheave, rendering it inoperable. CCSSC 4.9.8.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 12 December 2020
Resolved 12 December 2020
Resolution: Crew members were able to get the wire rope back on the sheave and a satisfactory lowering and raising of the rescue boat was completed.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 12 December 2020 Resolved
Every ship of 100 gross tonnage and above... shall carry a garbage management plan... and such plan shall be base on the guidelines developed by the Organization and MEPC.277(70). Garbage Management Plan did not include procedures for e-waste. Also, vessels garbage receipts need to reflect e-waste category. MARPOL 2017 Annex X/Reg. 10.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 December 2020
Resolved 3 January 2021
Resolution: Vessel updated their garbage management plan to include E-waste.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 12 December 2020 Resolved
The company and the ship shall comply with the requirements of the ISM code. The inspections mentioned in 10.2 as well as the measures referred to in 10.3 should be integrated into the ships operational maintenance routine. Heat detectors in engine room were tested using a lighter. Vessels SMS does not include procedures for properly testing heat and smoke detectors. 74 SOLAS (2014 cons.) Ch. IX/Reg. 3.1 ISM Code Part A/10.4
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 December 2020
Resolved 3 January 2021
Resolution: Vessels SMS was updated and included testing procedures for heat detectors based on manufacturers recommendations.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 9 October 2019 Resolved
03102 - The ring, lines and letters shall be painted in white or yellow on a dark ground or in black on a light ground. The "F" in the Tropical Fresh load line marking is painted the same color of the hull. ICLL 66/88 Ch 1 Reg 8
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 October 2019
Resolved 21 October 2019
Resolution: PHOTO PROVIDED SHOWING EVIDENCE OF CONTRASTING PAINT.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 9 October 2019 Resolved
07113 - The condition of the ship and it's equipment is maintained to conform with the provisions of this code. The hose on the emergency firepump had pultiple small holes throughout the etire length of the hose. CCSSC 1.11.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 October 2019
Resolved 21 October 2019
Resolution: HOSES REPLACED AND TESTED SATISFACTORILY
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 October 2018 Resolved
Vessel must maintain annual record of inspections onboard. VGP and NOI are not onboard. VGP pt 4.1.3 & 4.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 October 2018
Resolved 16 October 2018
Resolution: VGP NOI permit provided and accepted by Coast Guard.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 15 October 2018 Resolved
Every ship shall be provided with not less than six rocket parachute flares, six hand held red flare signals, and two buoyant orange smoke signals. Vessel could only provide 12 rocket parachute flares. CCSSC CHAPTER 4.14
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 October 2018
Resolution: Vessel acquired and can provide all required distress flares.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 October 2018 Resolved
According to the Non-tank vessel response plan, the vessel is to conduct Qualified Individual (QI) notification excercises quarterly. Vessel has not conducted any QI notifications. 33CFR 155.1060
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 October 2018
Resolution: Flag attestation received and accepted by PSCO.
Documentation › Logs/Records › Logbook (official)
Issued 11 April 2018 Resolved
0190 - Documentation - A record shall be kept to the satisfaction of the Administration and as required by radio regulations in reference to IMO Resolution A.694(17). Vessel did not log weekly or monthly checks in GMDSS logbook. 74SOLAS(Cons.)IV/17 - 16bc
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2018
Resolved 18 April 2018
Resolution: Received Flag attestation letter stating that GMDSS monthly and weekly checks were completed and logged. A copy of the log was also received for verification.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 10 April 2017 Resolved
Fire Control Plans shall be kept up to date. Plan indicates eyewash station location at aft bulkhead of galley. Eyewash station is missing water bottle to wash eyes. CCSS(15)ch.3/3.13.2. Action 40bc
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 November 2017
Resolution: Flag Attestation received and reviewed by PSCO
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 10 April 2017 Resolved
Condition of the ship and its equipment is maintained to conform with the Code to ensure the ship will remain fit to proceed to sea without danger to ship, persons on board, or environment. Port and Starboard propeller shaft seal has excessive leakage. CCSS(15)ch.1/1.11.1. Action 10c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 April 2017
Resolved 10 April 2017
Resolution: Replaced both seals during the exam. No further leakage present at time of exam.
Operations/Management › Pollution › Control of Garbage
Issued 10 April 2017 Resolved
A ship when in port of another Party is subject to inspection by officers duly authorized by such Party concerning operational requirements under this Annex. Appendix to Annex V form of Garbage Record Book. The master should obtain a receipt or certificate specifying the estimated amount of garbage transferred and receipts must be kept on board the ship. There are no receipts for garbage transfer.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 November 2017
Resolution: Flag state attestation received and reviewed by PSCO
Documentation › Certificates/Documents › Safety Management Certificate (ISM)
Issued 17 March 2017 Resolved
2515 - The company and the ship shall comply with the requirements of the ISM. AS of 03 March 2017 the vessel has been operating without a Safety Managment Company as indicated on their CSR invalidating their Safety Managment Certificate. 74 SOLAS (14 Cons.) CH. IX/Reg. 3.1
Action required: 705 - Other - as specified
Resolved 21 March 2017
Resolution: Vessel reinstated ISM requirements.
Operations/Management › Vessel Safety Management › Company Responsibilities/Authority
Issued 17 March 2017 Resolved
2550 - The safety-management system shall be maintained in accordance with the provisions of the International Safety Management Code. The vessel does not maintain a safety-management system and the Flag surveyor stated to the Port State Control Officers that the vessel is not required to abide by the International Safety Management Code. 74 SOLAS (14 Cons.) Ch. IX / Reg. 5 (30bc)
Action required: 705 - Other - as specified
Resolved 21 March 2017
Resolution: Vessel reinstated ISM requirements.
Lifesaving › Lifeboat › Markings
Issued 17 March 2017 Resolved
0615 - Each survival craft and rescue boat shall be marked in accordance with the requirements of the LSA Code as applicable. Rescue boat is not marked in accordance with the LSA Code. CCSSC Ch. 4 / Reg. 4.5 (17bc)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2017
Resolution: Vessel marked rescue boat IAW LSA Code.
Lifesaving › Lifebuoys › Self-Activitating Smoke Signals
Issued 17 March 2017 Resolved
In ships of 50 meters in length and over at least two of the lifebuoys provided with self-igniting lights shall also be provided with self-activating smoke signals. Vessel does not have at least two lifebuoys equipped with self-igniting lights and self-activating smoke signals. CCSSC Ch. 4 / Reg. 4.12.3 (17bc)
Action required: 705 - Other - as specified
Resolved 21 March 2017
Resolution: Vessel installed self-activating smoke bouys IAW CCSSC requiremts.
Engineering › Compressed Air System (control) › Compressor
Issued 23 December 2016 Resolved
1499: Owner or Master of every ship to which this Code applies should ensure that the condition of the ship and its equipment is maintained to ensure that the ship in all respects will remain fit to proceed to sea. Air compressors #1/#2 are leaking air and not working properly. The air tanks which provide air to control maneuverability of the ship cannot be filled as needed due to compressors.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 December 2016
Resolution: 2255 lcl - PSC/Duty MI has verified all necessary repairs have been made to the vessel to facilitate a safe departure from PEV. The COTP has been rescinded and the vessel agent NTFD. The vessel will make permanent repairs, verified by their Flag Represent
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 12 September 2016 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 31 October 2016
Resolution: PSCO verified all crew members had proper licenses and endorsements.
Documentation › Certificates/Documents › Exemption Certificate (SOLAS)
Issued 12 September 2016 Resolved
0100 - Ship's Certificates - A ship which is not normally engaged on international voyages but is required to take a single international voyage may be exempted by the Administration. Vessel could not provide letter of exemption for certificates. - SOLAS(14)I/4(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 September 2016
Resolution: The Administration provided an exemption for one voyage.
Construction/Loadline › Hull › Transverse Frame
Issued 31 December 2008 Resolved
Make permenant repairs to all intgral structural members called out for cropping and renewing. Dry Bulktanks #1P, #1S, 2P, and 2S will remain out-of-service until all repairs are completed to the satisfaction of of the attending US Coast Guard Inspector.
Due 7 May 2009
Resolved 31 October 2016
Resolution: Administratively closed due to change of flag and owner.
Communications › Public Address System › Loudspeaker
Issued 30 December 2008 Resolved
Install additional PA Speakers to service all normally manned spaces including berthing areas.
Due 11 January 2009
Resolved 31 December 2008
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 30 December 2008 Resolved
Repair Fuel Leak on F/O Transfer Pum
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 December 2008
Electrical › Lighting (emergency) › Lighting Fixture
Issued 30 December 2008 Resolved
Demonstrate proper operation of all emergency lights
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 December 2008
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 11 December 2008 Resolved
Remove Grease, Oil, and Debris from Engine Bilge area
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 December 2008
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 11 October 2006 Resolved
Provide radio operators permit for licensed mate
Due 27 November 2006
Resolved 13 November 2006
Navigation › Collision/Grounding Avoidance › Radar
Issued 11 October 2006 Resolved
Demonstrate proper operation of Port RADAR.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 November 2006
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 11 October 2006 Resolved
Post location of stove disconnect next to stove.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 November 2006
Fire Fighting › Means of Escape › Blocked
Issued 11 October 2006 Resolved
Label emergency escapes from engine room, "Emergency Escape, do not block."
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 November 2006
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 11 October 2006 Resolved
Demonstrate proper operation of starboard shaft tachometer.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 November 2006
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 11 October 2006 Resolved
Make lifelines easily deployable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 November 2006
Pollution Prevention/Response › Prevention Equipment
Issued 19 November 2002 Resolved
PROVIDE MSD 3/4 TANK LEVEL INDICATOR AS REQUIRED BY 33 CFR 159.83 LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Action required: 705 - Other - as specified
Due 20 December 2002
Resolved 11 December 2003
Lifesaving
Issued 22 November 1999 Resolved
DEMONSTRATE COMPLIANCE WITH D8 POLICY LETTER DATED 12NOV98 "RESCUE BOAT REQUIREMENTS ON OFFSHORE SUPPLY VESSELS" TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 22 November 1999
Resolved 22 November 1999
Documentation
Issued 7 January 1992 Resolved
SUBMIT FIRE CONTROL AND SAFETY PLAN WITH CHANGES MAKE TO USCG MARINE SAFETYOFFICE, NEW ORLEANS FOR REVIEW AND APPROVAL.
Condition: Unknown
Due 7 January 1992
Resolved 7 January 1992
Engineering
Issued 7 January 1992 Resolved
REPLACE FLAME SCREEN ON NO. 2 PORT FUEL OIL TANK VENT.
Condition: Unknown
Due 7 January 1992
Resolved 7 January 1992
Electrical
Issued 7 January 1992 Resolved
REMOVE OR REPAIR PLUG HANGING IN STBD ESCAPE TRUNK IN MACHINERY SPACE.
Condition: Unknown
Due 7 January 1992
Resolved 7 January 1992
Electrical
Issued 7 January 1992 Resolved
PROVIDE COVER ON JUNCTION BOX OVER BOW THRUSTER ENGINE.
Condition: Unknown
Due 7 January 1992
Resolved 7 January 1992
Fire Fighting
Issued 7 January 1992 Resolved
PROVIDE PROOF OF FIRE FIGHTING EQUIPMENT INSPECTION AND SERVICING TO INCLUDE PORTABLE FIRE EXTINGUISHERS AND FIXED HALON SYSTEM FOR MACHINERY SPACE. TEST OR REPLACE HOSE FROM FWD HALON TANK DUE TO CHAFFING.
Condition: Unknown
Due 7 January 1992
Resolved 7 January 1992
Electrical
Issued 7 January 1992 Resolved
REMOVE OR REPAIR ELECTRICAL OUTLET ON EXTERIOR AFT HOUSE BULKHEAD ON 01 DECK.
Condition: Unknown
Due 7 January 1992
Resolved 7 January 1992
Lifesaving
Issued 7 January 1992 Resolved
PROVIDE MARKINGS AT PORT/STBD MACHINERY SPACE ESCAPE TRUNKS WHICH READS "EMERGENCY EXIT KEEP CLEAR" IN AT LEAST 2 INCH LETTERS. PROVIDE EMERGENCY LIGHTING FOR ESCAPE TRUNKS.
Condition: Unknown
Due 7 January 1992
Resolved 7 January 1992
Documentation
Issued 7 January 1992 Resolved
PROVIDE LOADLINE CERTIFICATE WITH STABILITY INFORMATION AS REQUIRED BY USCG.
Condition: Unknown
Due 7 January 1992
Resolved 7 January 1992
Electrical
Issued 7 January 1992 Resolved
PROVE PROPER OPERATION OF BOTH GENERATOR OVERSPEED TRIPS.
Condition: Unknown
Due 7 January 1992
Resolved 7 January 1992
Engineering
Issued 7 January 1992 Resolved
REPLACE RELIEF VALVES ON SHIP SERVICE AIR RECEIVERS (P/S) AND PROVE PROPER OPERATION. REPLACE PRESSURE GUAGE ON PORT AIR RECEIVER.
Condition: Unknown
Due 7 January 1992
Resolved 7 January 1992
Deck/Cargo
Issued 7 January 1992 Resolved
MAKE PERMANENT REPAIRS TO LIQUID MUD LINE NO. 1 IN STBD FWD OVERHEAD OF MACHINERY SPACE WHERE RED HAND PATCH IS INSTALLED.
Condition: Unknown
Due 7 January 1992
Resolved 7 January 1992
Electrical
Issued 7 January 1992 Resolved
REPAIR ALL WIRING AND LIGHTING FIXTURES (EXPLOSION PROOF) FOR DECK LIGHTINGPORT AND STBD MAIN DECK AFT.
Condition: Unknown
Due 7 January 1992
Resolved 7 January 1992
Deck/Cargo
Issued 7 January 1992 Resolved
REPLACE STARBOARD ANCHOR, WHICH IS MISSING.
Condition: Unknown
Due 7 January 1992
Resolved 7 January 1992
Unknown
Issued 9 November 1988 Resolved
EFFECT REPAIRS AND PROVE SATISFACTORY OPERATION OF HYDROULIC ACCUMULATOR START UNIT ON NO.2 GENERATOR AS PER 46 CFR 111.10-7.
Condition: Unknown
Due 9 November 1988
Resolved 9 November 1988
Navigation
Issued 28 September 1988 Resolved
EFFECT REPAIRS AND PROVE SATISFACTORY OPERATION OF STEERING GEAR ALARM PANEL IN PILOT HOUSE AS PER 46CFR111.93-13.
Condition: Unknown
Due 28 September 1988
Resolved 28 September 1988
Electrical
Issued 28 September 1988 Resolved
EFFECT REPAIRS AND PROVE SATISFACTORY OPERATION OF REMOTE FUEL-OIL TRANSFER PUMP SHUT-DOWN LOCATED ON MAIN DECK STARBOARD SIDE ENGINE ROOM SCUTTLE AS PER 46CFR111.O3-9.
Condition: Unknown
Due 28 September 1988
Resolved 28 September 1988
Electrical
Issued 28 September 1988 Resolved
EFFECT REPAIRS AND PROVE SATISFACTORY OPERATION OF HYDRAULIC ACCUMULATOR START UNIT ON NO. 2 GENERATOR AS PER 46CFR111.10-7.
Condition: Unknown
Due 28 September 1988
Resolved 28 September 1988
Lifesaving
Issued 28 September 1988 Resolved
PROVIDE TWENTY-FIVE (25) CARTRIDGES FOR THE REQUIRED SHOULDER GUN TYPE LINE-THROWING APPLIANCE AS PER 46CFR94.45-15(B)(2).
Condition: Unknown
Due 28 September 1988
Resolved 28 September 1988
Lifesaving
Issued 28 September 1988 Resolved
PROVIDE ONE AUXILIARY LINE FOR THE REQUIRED SHOULDER GUN TYPE LINE-THROWINGAPPLIANCE AS PER 46CFR94.45-15(B)(6).
Condition: Unknown
Due 28 September 1988
Resolved 28 September 1988
Construction/Loadline
Issued 29 June 1987 Resolved
OBTAIN COAST GUARD APPROVAL FOR MODIFICATIONS IN WAY OF VESSELS "P" TANKS. COMPLIANCE DATE IS 20MAR87.
Condition: Unknown
Due 29 June 1987
Resolved 29 June 1987
Documentation
Issued 12 September 1986 Resolved
MAN VESSEL IN ACCORDANCE WITH USCG CERTIFICATE OF INSPECTION INCLUDING PROPER NUMBER OF LICENSED MATE(S), LICENSED ENGINEER(S), AND DOCUMENTED SEAMEN.
Condition: Unknown
Due 12 September 1986
Resolved 12 September 1986
Navigation
Issued 12 September 1986 Resolved
RE-POSITION RED & GREEN SIDELIGHTS ABEAM OF, OR AFT OF, MASTHEAD LIGHT IN ACCORDANCE WITH COLREGS 72 ANNEX I. ALTERNATELY, APPLY TO COMMANDANT,USCG,WASH., D. C., FOR A CERTIFICATE OF ALTERNATIVE COMPLIANCE.
Condition: Unknown
Due 12 September 1986
Resolved 12 September 1986
Lifesaving
Issued 12 September 1986 Resolved
REPLACE RFD, 20 MAN RAFTS WITH USCG APPROVED RAFTS. ALTERNATELY, DEMONSTRATE INSTALLED RFD RAFTS ARE USCG APPROVED. INSTALL WEAK LINKS ON RAFT PAINTER TO CRADLE CONNECTION.
Condition: Unknown
Due 12 September 1986
Resolved 12 September 1986
Lifesaving
Issued 12 September 1986 Resolved
PROVIDE AN APPROVED RESCUE BOAT, PROPERLY EQUIP IT, AND STOW FOR IMMEDIATE SERVICE AS SPECIFIED BY [name withheld].
Condition: Unknown
Due 12 September 1986
Resolved 12 September 1986
Construction/Loadline
Issued 12 September 1986 Resolved
SUBMIT FOR APPROVAL PAINT LOCKER INSTALLATION. ALTERNATELY, REMOVE ALL PAINT FROM VESSEL.
Condition: Unknown
Due 12 September 1986
Resolved 12 September 1986
Unknown
Issued 12 September 1986 Resolved
PROVIDE 4 FOOT APPLICATOR FOR MACHINERY SPACE.
Condition: Unknown
Due 12 September 1986
Resolved 12 September 1986
Unknown
Issued 12 September 1986 Resolved
PROVIDE USCG APPROVED, PROPERLY SIZED AND SERVICED FIRE EXTINGUISHER FOR STATION 8 IN ENGINE ROOM.
Condition: Unknown
Due 12 September 1986
Resolved 12 September 1986
Unknown
Issued 12 September 1986 Resolved
PROVIDE SPARE FIRE EXTINGUISHERS ABOARD VESSEL IN ACCORDANCE WITH 46 CFR 95.50-15(A),
Condition: Unknown
Due 12 September 1986
Resolved 12 September 1986
Unknown
Issued 12 September 1986 Resolved
PROVE OPERATION OF OVERSPEED TRIP ON BOW THRUSTER ENGINE.
Condition: Unknown
Due 12 September 1986
Resolved 12 September 1986
Unknown
Issued 12 September 1986 Resolved
PROVIDE 10 BULK TANK RELIEF VALVES TO RELIEVE AT OR BELOW THE MAXIMUM ALLOWABLE WORKING PRESSURE OF THE RESPECTIVE TANKS.
Condition: Unknown
Due 12 September 1986
Resolved 12 September 1986
Unknown
Issued 12 September 1986 Resolved
PROVIDE RELIEF VALVE ON HOT WATER HEATER TO RELIEVE AT NOT MORE THAN 100 PSIG AND 200 DEGREES F.
Condition: Unknown
Due 12 September 1986
Resolved 12 September 1986
Unknown
Issued 12 September 1986 Resolved
INSTALL REVERSE POWER RELAY ON MAIN SWITCHBOARD.
Condition: Unknown
Due 12 September 1986
Resolved 12 September 1986
Unknown
Issued 12 September 1986 Resolved
PROVIDE AN ADDITIONAL 2 USCG APPROVED VISUAL DISTRESS SIGNALS (RED FLARES).
Condition: Unknown
Due 12 September 1986
Resolved 12 September 1986
Documentation
Issued 12 September 1986 Resolved
SUBMIT REVISED LIGHTSHIP DATA AND STABILITY CALCULATIONS TO USCG MARINE SAFETY CENTER, WASH. D. C. BASED ON CEMENT EQUIPMENT AND 20 TON CRANE RECENTLY ADDED TO DECK.
Condition: Unknown
Due 12 September 1986
Resolved 12 September 1986
Unknown
Issued 12 September 1986 Resolved
MAKE PERMANENT REPAIRS IN WAY OF #3 PORT & STARBOARD BALLAST TANKS WHERE BULK TANKS HAVE SEPARATED FROM TANK OVERHEAD.
Condition: Unknown
Due 12 September 1986
Resolved 12 September 1986
Unknown
Issued 12 September 1986 Resolved
GROUND ALL 110V OUTLETS INDEPENDENT OF CABLE ARMORING AND THE VESSEL'S HULL.
Condition: Unknown
Due 12 September 1986
Resolved 12 September 1986
Unknown
Issued 12 September 1986 Resolved
TEST FUEL OIL AND LIQUID MUD TRANSFER HOSE TO A MINIMUM OF 225 PSIG.
Condition: Unknown
Due 12 September 1986
Resolved 12 September 1986
Unknown
Issued 12 September 1986 Resolved
PROVE OPERATION OF BILGE HIGH LEVEL ALARMS.
Condition: Unknown
Due 12 September 1986
Resolved 12 September 1986
Construction/Loadline
Issued 5 August 1986 Resolved
PROVIDE ON BOARD IN EACH HAWSEPIPE PORT & STARBOARD ANCHOR AS REQUIRED BY ABS IF THE VESSEL IS CLASSED. 46 CFR 96.07 WHICH REFERS YOU TO ABS RULES.
Condition: Unknown
Due 5 August 1986
Resolved 5 August 1986
Engineering
Issued 28 January 1986 Resolved
PROVIDE COAST GUARD APPROVED TEST PROCEEDURE FOR A MACHINERY AUTOMATION SYSTEM. THIS REQUIREMENT MAY BE CLEARED BY LETTER TO [name withheld].
Condition: Unknown
Due 28 January 1986
Resolved 28 January 1986
Deck/Cargo
Issued 28 January 1986 Resolved
REPAIR OR REPLACE STARBOARD ANCHOR WITH ABS APPROVED ONE NO LATER THAN 30SEP86. THIS REQUIREMENT MAY BE CLEAR BY LETTER TO [name withheld].
Condition: Unknown
Due 28 January 1986
Resolved 28 January 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.