MAURY USCG vessel records Sign in
← All vessels

JUMBO CHALLENGER

JUMBO CHALLENGER is a 1982 freight ship. The Coast Guard has recorded 38 inspections since 1984, most recently in November 2010, along with 21 deficiencies and 2 operational controls.

Records from 1984 to 2010. Most recent: inspection, 2 November 2010.

Built
1982
Last inspected
2 November 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8110887 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
236278
Flag
NETHERLANDS
—
Maury page id
psix-236278

Inspections, by type

…with no type recorded28
Years with a record 21 calendar years (1984–2010)
The 38 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it2610 - Convention (Subpart B), Net Ton
6555 - Convention (Subpart B), Gross Ton
5928 - Dead Weight, Ton
6833 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 38

2 November 2010 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3877178
28 July 2009 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3548572
20 December 2008 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3380464
16 December 2008 ISPS I Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3380903
20 August 2008 MARPOL Annex V Examination · ISPS II Exam · Ballast Water Examination · PII Safety Exam · MARPOL Annex I Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3303282
20 August 2008 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3304069
1 March 2007 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2880003
19 February 2007 Random ISPS/MTSA/PSC · Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2874023
18 February 2007 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2874524
17 February 2007 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2879221
14 February 2007 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2872241
2 September 2006 ISPS III Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2766496
14 October 2005 ISPS II Exam
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2512248
14 January 2005 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2274988
10 March 2003 Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1755297
30 March 2001 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 288562
14 October 2000 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 284633
24 September 2000 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 282363
24 March 2000 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 276868
23 February 1999 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 425766
2 February 1999 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 425183
16 June 1998 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 417398
10 March 1998 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 413510
27 February 1997 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 400949
7 November 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 397201
22 March 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 389268
26 October 1995 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 383741
16 November 1994 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 372423
16 September 1993 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 360740
22 November 1991 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 347245
20 May 1991 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 436401
15 November 1990 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 340327
14 May 1990 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 457679
20 November 1989 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 333770
4 February 1989 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 440110
20 July 1988 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 324567
24 December 1984 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1284912
19 September 1984 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 298052

Deficiency record · 21

Fire Fighting › Remote Fuel Shutoff › General
Issued 2 November 2010 Resolved
1499 - Other (Prop. & Aux Mach.) - Hydraulic actuator for remote shutoff valve on HFO service tank leaking hydraulic oil. Valve was tested and found operational. Repair leak to satisfaction of class. - SOLAS 74a II-2/4.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 2 November 2010
Resolved 6 November 2010
Resolution: Received, reviewed and accepted class report from [name withheld] stating the deficiency was rectified. leaking valve was overhauled and tested as verified by the class surveyor.
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 19 February 2007 Resolved
Conduct external audit of ships safety management system. Non-conformities were found in the derrick cranes maintenance records. SOLAS 74 Ch. IX, ISM Code Part A/10
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 March 2007
Resolution: LR completed audit.
Operations/Management › Casualty Reporting/Post-Casualty Actions › Notice of Marine Casualty
Issued 19 February 2007 Resolved
Provide class report of completed damage survey and ascertain vessels seaworthiness.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 March 2007
Resolution: LR submitted report that permanent repairs have been completed.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 19 February 2007 Resolved
Provide written plan for loading cargo hatches to the Coast Guard Sector LA/LB prior to conducting this operation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 March 2007
Resolution: Received class report correcting deficiencies.
Fire Fighting
Issued 24 March 2000 Resolved
PRESSURE FROM EMERGENCY FIRE PUMP SEEMS TO BE SUBSTANDARD. PROVE PROPER OPERATION TO THE SATISFACTION OF CLASS PRIOR TO 01MAY00.
Condition: Unknown
Due 25 September 2000
Resolved 25 September 2000
Deck/Cargo
Issued 23 February 1999 Resolved
VESSELS LIFEBOAT FALLS ARE PAST DUE TO BE END OVER ENDED IN VIOLATION OF SOLAS 74 III/19-4. _x001C_ CORRECT PRIOR TO NEXT US PORT.
Condition: Unknown
Due 14 April 2000
Resolved 14 April 2000
Fire Fighting
Issued 23 February 1999 Resolved
ONE OF THE VESSELS SCBA'S WAS LEAKING IN THE CONNECTION TO THE REGULATOR INVIOLATION OF SOLAS 74 II-2/17-1.2_x001C_ VESSEL MUST CORRECT PRIOR TO DEPARTURE.
Condition: Unknown
Due 25 February 1999
Resolved 25 February 1999
Fire Fighting
Issued 23 February 1999 Resolved
VESSELS EMERGENCY FIRE PUMP INOP. IN VIOLATION OF SOLAS 74 II-2/4-3.3 _x001C_ CORRECT PRIOR TO DEPARTURE.
Condition: Unknown
Due 25 February 1999
Resolved 25 February 1999
Navigation
Issued 23 February 1999 Resolved
VESSEL MISSING CHART 2605 OR U.S. EQUIVALENT. MUST OBTAIN PRIOR TO DEPARTURE.
Condition: Unknown
Due 25 February 1999
Resolved 25 February 1999
Lifesaving
Issued 23 February 1999 Resolved
VESSEL NEEDS TO PERFORM FIRE AND BOAT DRILLS PRIOR TO DEPARTURE.(SOLAS 74 III/18.3) CORRECT PRIOR TO DEPATURE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 February 1999
Resolved 25 February 1999
Documentation
Issued 2 February 1999 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 2 February 1999
Resolved 10 February 1999
Documentation
Issued 2 February 1999 Resolved
Oil Record Book had 15 completed pages not signed by the Master.
Condition: Unknown
Due 10 February 1999
Resolved 10 February 1999
Documentation
Issued 2 February 1999 Resolved
Specific cite: STCW II/1_x001C_ Chief Engineer was sailing with expired license. Flag State approved ChiefEngineer to sail on vessel. Chief Engineer is required to have current license prior to next U.S. port.
Condition: Unknown
Due 25 February 1999
Resolved 25 February 1999
Fire Fighting
Issued 10 March 1998 Resolved
EMERGENCY FIRE PUMP TAKES EXCESSIVE TIME TO GET PRIMED. CREW INSTALLED THEPRIMING TANK.
Condition: Unknown
Due 30 June 1998
Resolved 30 June 1998
Documentation
Issued 7 November 1996 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 27 February 1997
Resolved 27 February 1997
Construction/Loadline
Issued 26 October 1995 Resolved
MAKE PERMANENT REPAIRS TO 4 INCH HOLE ON PORT QUARTER WHERE TRANSOM AND HULL PLATE MEET.
Condition: Unknown
Due 22 March 1996
Resolved 22 March 1996
Documentation
Issued 22 November 1991 Resolved
VESSELS OIL TRANSFER PROCEDURES WERE INCOMPLETE. THE PROCEDURES WERE MISSING DUTIES OF EACH OFFICER REQUIRED FOR OIL TRANSFER OPERATIONS AND PROCEDURES FOR THE MEANS OF COMMUNICATIONS.
Condition: Unknown
Due 16 September 1993
Resolved 16 September 1993
Construction/Loadline
Issued 22 November 1991 Resolved
VESSELS OILY WATER SEPARATOR IS NOT OPERATIONAL DUE TO A DISCHARGE VALVE MALFUNCTION. VESSEL HAS REPLACEMENT PART AND WILL REPLACE UPON DEPARTING SDCMS.
Condition: Unknown
Due 16 September 1993
Resolved 16 September 1993
Navigation
Issued 20 November 1989 Resolved
33CFR164.35(D) VESSELS MAIN GYRO COMPASS NOT OPERABLE. AUTHORITY CITE:33USC1223 PENALTY CITE:33USC1232
Condition: Unknown
Due 20 November 1989
Resolved 20 November 1989
Navigation
Issued 20 November 1989 Resolved
33CFR164.53(B)VESSEL DID NOT REQUEST DEVIATION FROM THE RULES FOR ENTRY INTO HOUMS ZONE WITHOUT AN OPERABLE MAIN GYRO COMPASS. AUTHORITY CITE:33USC1223 PENALTY CITE:33USC1232
Condition: Unknown
Due 20 November 1989
Resolved 20 November 1989
Documentation
Issued 20 July 1988 Resolved
A VIO OF 33 CFR 156.170 IN THAT THE EQUIPMENT TEST & INSPECTIONS REQ. BY 33 CFR 156.170(F)(2) WERE NOT CONDUCTED BY THE VSL.
Condition: Unknown
Due 20 July 1988
Resolved 20 July 1988

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.