MAURY USCG vessel records Sign in
← All vessels

KAI KANANI

KAI KANANI is a 1984 school ship. The Coast Guard has recorded 67 inspections since 1984, most recently in August 2023, along with 184 deficiencies and 1 casualty investigation in 2003.

Records from 1984 to 2023. Most recent: inspection, 3 August 2023.

Built
1984
Last inspected
3 August 2023
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WBE9509
236451
Flag
UNITED STATES
—
Maury page id
psix-236451

Inspections, by type

…with no type recorded6
Years with a record 25 calendar years (1984–2023)
The 67 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the School Ship class in Maury's sources begin in 1981.

Documentation record

Registered dimensions (L × B × D)46.0 ft × 21.0 ft × 5.3 ft
Registered tonnagegross 16 / net 13
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHISAO MURAKAMI · HONOLULU, HI, UNITED STATES · built 1984
Hull materialWood
PropulsionAuxiliary Sail
Hull shapeNot recorded
Hull configurationTwin Hull
Hailing portMAKENA, HI
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itSchool Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it16 - Simplified, Gross Ton
13 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WBE9509MMSI not assigned · expired · compulsorily equipped · granted 25 February 1997, cancelled 3 June 2007
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 67

3 August 2023 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7786451
1 November 2007 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3091404
25 April 2007 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2915500
4 October 2006 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2793652
3 October 2006 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2793005
12 December 2005 Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2728400
2 December 2005 Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2544447
3 February 2005 COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2290962
14 May 2004 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2070546
13 February 2004 Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2006344
13 October 2003 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1947957
1 October 2003 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1919124
7 June 2003 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1903014
27 December 2002 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1724338
13 December 2002 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1717765
11 June 2002 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1629535
8 May 2002 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1613718
10 January 2002 Examination of Repairs · Damage Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1495797
28 November 2001 Hull Examination · Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1373685
2 October 2001 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1077149
4 April 2001 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1064656
7 March 2001 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1417237
18 February 2000 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 815563
10 February 2000 Type not recorded
No type recorded · USCG Oceania District (dre) · USCG Oceania District (CGD-O) · Activity 717315
10 February 2000 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1369518
6 February 2000 Type not recorded
No type recorded · Station Maui · USCG Oceania District (CGD-O) · Activity 1518117
11 January 2000 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1045892
23 December 1999 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1361314
10 March 1999 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1386478
3 April 1998 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1398876
4 March 1998 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1375296
21 November 1997 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 774147
16 September 1997 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1407970
24 July 1997 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1119427
19 June 1997 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1112496
16 May 1997 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1383568
18 April 1997 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1368192
9 August 1996 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1377797
6 June 1996 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1374646
16 May 1996 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1394546
3 April 1996 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1353898
7 March 1996 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1367662
2 November 1995 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1377544
13 September 1995 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1394381
4 March 1995 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1357050
8 April 1994 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1356601
22 November 1993 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1470889
17 June 1993 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 827358
4 March 1993 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1145003
21 March 1992 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1318314
5 March 1992 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 953593
16 December 1991 Damage Survey · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1401609
8 April 1991 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 904558
4 March 1991 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 995131
21 September 1990 Hull Examination · Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 902540
9 April 1990 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 922520
9 March 1989 COI Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 895498
6 December 1988 Damage Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1346306
22 September 1988 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1340088
12 September 1988 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1340086
28 June 1988 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1034154
9 June 1988 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 897401
8 September 1987 COI Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1006500
16 October 1986 Credit Drydock
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1318393
19 September 1985 Credit Drydock · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1304010
1 November 1984 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1284705
26 October 1984 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1284466

Deficiency record · 184

Documentation › Certificates/Documents › Certificate of Inspection
Issued 1 November 2007 Resolved
Vessel failed to complete any part of a 42 item worklist issued during an attempted credit drydock started on 01NOV07. The 5 page worklist is scaned into the vessels electronic documents section.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 February 2009
Resolution: Vessel owners surrendered COI.
Communications › Radio Communications › EPIRB
Issued 25 April 2007 Resolved
Renew hydrostatic release.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2007
Resolved 30 April 2007
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 25 April 2007 Resolved
Prove deck railing on main deck forward.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2007
Resolved 30 April 2007
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 25 April 2007 Resolved
Provice an annual fixed firefighting certificate.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2007
Resolved 30 April 2007
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 25 April 2007 Resolved
Renew float light on port side lifefloat.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2007
Resolved 30 April 2007
Lifesaving › Lifebuoys › Serviceable
Issued 25 April 2007 Resolved
Renew lifering.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2007
Resolved 30 April 2007
Lifesaving › Lifefloat › Float Free
Issued 25 April 2007 Resolved
Prove painter lanchers on both port and stbd sides.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2007
Resolved 30 April 2007
Construction/Loadline › Structures › Superstructure
Issued 25 April 2007 Resolved
Renew fractures chainplates.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2007
Resolved 30 April 2007
Construction/Loadline › Structures › Superstructure
Issued 25 April 2007 Resolved
Provide a professional rigging survey for mast, and all standing and running rigging on deck and aloft.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2007
Resolved 17 February 2009
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 25 April 2007 Resolved
Provide an approved mounting brack for each required portable fire extinguisher.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2007
Resolved 30 April 2007
Personnel › Certificates/Documents/Licenses › Certificate, First Aid Course Completion
Issued 4 October 2006 Resolved
Provide proof of first aid course completion and FCC radio operators license.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 November 2006
Resolved 12 October 2006
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 4 October 2006 Resolved
Provide proof of servicing for fixed firefighting equipment.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 October 2006
Resolved 5 October 2006
Construction/Loadline › Structures › Manhole
Issued 4 October 2006 Resolved
Renew as original starboard forward hatch due to cracking of FRP and wood around the edge of the hatch.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 November 2006
Resolved 8 November 2006
Lifesaving › Lifefloat › Serviceable
Issued 4 October 2006 Resolved
Renew as original whole in port side lifefloat.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 November 2006
Resolved 4 November 2006
Lifesaving › Lifefloat › Lifeline
Issued 4 October 2006 Resolved
Renew as original starboard side lifefloat lifelines.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 November 2006
Resolved 4 November 2006
Lifesaving › Lifefloat › Retroreflective Material
Issued 4 October 2006 Resolved
Renew as original retroreflective tape on both lifefloats.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 November 2006
Resolved 4 November 2006
Operations/Management › Drug and Alcohol Testing
Issued 13 February 2004 Resolved
Provide materials for DAPI audit. LEGACY COMPONENT DESC: Recordkeeping
Condition: Improper/Lack of Maintenance
Due 11 March 2004
Resolved 14 May 2004
Lifesaving › Lifejacket/PFD (Type I)
Issued 13 February 2004 Resolved
Provide (2) adult CG approved lifejackets. Passenger count restricted to 40 adults. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Due 14 May 2004
Resolved 14 May 2004
Personnel › Certificates/Documents/Licenses
Issued 13 February 2004 Resolved
Provide CPR certificate for 50% of crew. LEGACY COMPONENT DESC: Certificate, CPR Course Completion
Condition: Unknown
Due 11 March 2004
Resolved 14 May 2004
Personnel › Certificates/Documents/Licenses
Issued 13 February 2004 Resolved
Provide proof of FCC Marine Radio Operator permit. LEGACY COMPONENT DESC: License, Operator
Condition: Unknown
Due 11 March 2004
Resolved 14 May 2004
Operations/Management
Issued 13 February 2004 Resolved
Post small passenger vessel decal. LEGACY COMPONENT DESC: Small passenger vessel decal
Condition: Unknown
Due 14 May 2004
Resolved 14 May 2004
Navigation › Piloting/Steering
Issued 13 February 2004 Resolved
Provide tide tables/tidal current tables. LEGACY COMPONENT DESC: Tide/Tidal Current Tables
Condition: Unknown
Due 14 May 2004
Resolved 14 May 2004
Operations/Management › Equipment Service/Testing
Issued 13 February 2004 Resolved
Make log entries for lifesaving equipment. LEGACY COMPONENT DESC: lifesaving
Condition: Improper/Lack of Maintenance
Due 11 March 2004
Resolved 14 May 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 1 October 2003 Resolved
Submit plans for fwd rail. Passengers not allowed fwd until plans approved by [name withheld]: Deck Rail
Condition: Unknown
Due 30 October 2003
Resolved 13 October 2003
Electrical › Electric Supply System (service)
Issued 1 October 2003 Resolved
Install battery box covers. LEGACY COMPONENT DESC: Battery Installation
Condition: Unknown
Due 15 October 2003
Resolved 13 October 2003
Operations/Management › Equipment Service/Testing
Issued 1 October 2003 Resolved
Provide deminsions for sail area. Vessel notallowed to proceed under sail until sail plan is approved. LEGACY COMPONENT DESC: Sails
Condition: Unknown
Due 13 October 2003
Resolved 13 October 2003
Construction/Loadline › Hull › Hull Plating
Issued 1 October 2003 Resolved
Repair patches on port hull. Patches were ground down and repairs approved.
Condition: Unknown
Due 1 October 2003
Resolved 1 October 2003
Construction/Loadline › Hull
Issued 1 October 2003 Resolved
Repair cracked frame located in port hull. LEGACY COMPONENT DESC: frame
Condition: Unknown
Due 1 October 2003
Resolved 1 October 2003
Construction/Loadline › Structures › Scuttle
Issued 1 October 2003 Resolved
Replace hinge for stbd lazarrette hatch.
Condition: Unknown
Due 1 October 2003
Resolved 1 October 2003
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 October 2003 Resolved
Remove or properly repair dead end wire located in stbd fuel tank space.
Condition: Unknown
Due 1 October 2003
Resolved 1 October 2003
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 1 October 2003 Resolved
Seal exhaust hose transiting thru engine room blkhd to lazarrette space. LEGACY COMPONENT DESC: BLKHD
Condition: Unknown
Due 1 October 2003
Resolved 1 October 2003
Communications › Radio Communications
Issued 13 December 2002 Resolved
Replace EPIRB battery and prove proper operation to marine inspector prior to carrying passengers. LEGACY COMPONENT DESC: EPIRB
Condition: Improper/Lack of Maintenance
Due 13 December 2002
Resolved 27 December 2002
Engineering › Bilge Water Management System
Issued 13 December 2002 Resolved
Prove proper operation of visual alarm for automatic bilge pump IAW 46CFR182.520. LEGACY COMPONENT DESC: Pump
Condition: Unknown
Due 13 January 2003
Resolved 27 December 2002
Engineering › Bilge Water Management System
Issued 13 December 2002 Resolved
Prove proper operation of audio alarm for high water alarm Iaw 46CFR182.530. LEGACY COMPONENT DESC: High water alarm
Condition: Unknown
Due 13 January 2003
Resolved 27 December 2002
Navigation › Piloting/Steering
Issued 13 December 2002 Resolved
Prove proper operation of light for compass. Vessel restricted to day light operations. LEGACY COMPONENT DESC: Gyro Compass
Condition: Placed in Improper Service
Due 13 January 2003
Resolved 27 December 2002
Engineering › Bilge Water Management System
Issued 13 December 2002 Resolved
Provide port engine room bilge discharge hose IAW 46CFR182.520. LEGACY COMPONENT DESC: Hose
Condition: Unknown
Due 13 January 2003
Resolved 27 December 2002
Lifesaving › Buoyant Apparatus
Issued 13 December 2002 Resolved
Make proper repairs to bouyant apparatus to manufactues specs.
Condition: Improper/Lack of Maintenance
Due 13 January 2003
Resolved 27 December 2002
Lifesaving › Lifebuoys
Issued 13 December 2002 Resolved
Prove proper operation of light for lifebuoy IAW 46CFR180.70. LEGACY COMPONENT DESC: Self-igniting Lights
Condition: Improper/Lack of Maintenance
Due 13 January 2003
Resolved 27 December 2002
Electrical › Electrical Distribution System (service)
Issued 13 December 2002 Resolved
Install metal supports in generator space IAW 46CFR183.340. LEGACY COMPONENT DESC: Wiring
Condition: Placed in Improper Service
Due 13 January 2003
Resolved 27 December 2002
Electrical › Electrical Distribution System (service)
Issued 13 December 2002 Resolved
Properly install switch for MSD in STBD head. LEGACY COMPONENT DESC: Switch
Condition: Unknown
Due 13 January 2003
Resolved 27 December 2002
Communications › Radio Communications
Issued 13 December 2002 Resolved
Replace hydrostatic release for EPIRB. LEGACY COMPONENT DESC: EPIRB
Condition: Improper/Lack of Maintenance
Due 13 January 2003
Resolved 27 December 2002
Electrical › Electrical Distribution System (service)
Issued 8 May 2002 Resolved
Remove/properly repair dead end wires located in fwd generator space, port/stbd engine rooms and sewage space IAW 46CFR183.340. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Due 24 May 2002
Resolved 31 May 2002
Electrical › Electrical Distribution System (service)
Issued 8 May 2002 Resolved
Install metal supports for cable wiring in port/stbd engine rooms IAW 46CFR183.340. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Due 24 May 2002
Resolved 31 May 2002
Engineering › Steering Gear System
Issued 8 May 2002 Resolved
Replace handle for hydraulic shutoff valve stbd steering system IAW 46CFR182.710. LEGACY COMPONENT DESC: Valve
Condition: Improper/Lack of Maintenance
Due 24 May 2002
Resolved 31 May 2002
Accommodation/Occupational Safety › Medical/First Aid
Issued 8 May 2002 Resolved
Provide eyewash for first aid kit IAW 46CFR184.710. LEGACY COMPONENT DESC: Medicine Chest
Condition: Unknown
Due 24 May 2002
Resolved 31 May 2002
Fire Fighting › Structural Fire Protection - General
Issued 8 May 2002 Resolved
Make port engineroom aft blkhd vapor tight IAW 46CFR181.400/ LEGACY COMPONENT DESC: Structural Bulkhead Construction
Condition: Improper Installation
Due 24 May 2002
Resolved 31 May 2002
Lifesaving › Buoyant Apparatus
Issued 8 May 2002 Resolved
Provide 12 man lifefloat IAW 46CFR180.200. Passenger count is restricted 21 passengers.
Condition: Improper/Lack of Maintenance
Due 8 May 2002
Resolved 13 December 2002
Lifesaving › Lifejacket/PFD (Type I)
Issued 8 May 2002 Resolved
Provide 10 adult CG approved life jackets IAW 46CFR180.71. Passenger count is restricted to 32 passengers. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Due 8 May 2002
Resolved 31 May 2002
Navigation › Piloting/Steering
Issued 8 May 2002 Resolved
Provide CG light list and U.S. Coast Pilot IAW 46CFR184.420. LEGACY COMPONENT DESC: Coast Guard Light List
Condition: Unknown
Due 24 May 2002
Resolved 11 June 2002
Resolution: Recieved faxed reciept.
Documentation › Logs/Records › Drug Test Records
Issued 8 May 2002 Resolved
Submitt managment info system form to commandant(G-MAO) IAW 46CFR part 16.
Condition: Unknown
Due 24 May 2002
Resolved 9 May 2002
Lifesaving › Hand Flares
Issued 8 May 2002 Resolved
Provide (1) orange day smoke IAW 46 CFR180.68. LEGACY COMPONENT DESC: Quantity
Condition: Unknown
Due 8 May 2002
Resolved 8 May 2002
Engineering › Bilge Water Management System
Issued 10 January 2002 Resolved
Prove proper operation of all bilge high level alarms IAW 46CFR182.530. LEGACY COMPONENT DESC: Bilge alarms
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 January 2002
Resolved 25 January 2002
Engineering › Bilge Water Management System › Pump
Issued 10 January 2002 Resolved
Prove proper operation of all bilge pumps IAW 46CFR182.520.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 January 2002
Resolved 25 January 2002
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 10 January 2002 Resolved
Port and STBD fixed fire fighting systems are both too small for the spaces intended. Prove compliance with 46CFR181.400 NLT 01FEB02. Provide two additional CG approved B-II portable fire extinguishers properly serviced, mounted, and readily accessible prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 February 2002
Resolved 10 January 2002
Electrical › Lighting (service)
Issued 10 January 2002 Resolved
Port side #2 void: Light fixture dangling from bulkhead. Properly secure IAW 46CFR183.220 NLT 22JAN02.
Due 22 January 2002
Resolved 25 January 2002
Engineering › Steering Gear System
Issued 10 January 2002 Resolved
Fracture in stbd side steel rudder control arm. Effect proper repair IAW 46CFR176.700 & 176.800.
Due 22 January 2002
Resolved 25 January 2002
Engineering › Steering Gear System › Rudder
Issued 10 January 2002 Resolved
Stbd rudder damaged and not connected to lower mount. Effect proper repair prior to carrying passengers iaw 46cfr176.800.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 January 2002
Resolved 25 January 2002
Engineering › Steering Gear System
Issued 10 January 2002 Resolved
Stbd prop damaged. Effect proper repair IAW 46CFR176.800. LEGACY COMPONENT DESC: Propeller
Due 1 February 2002
Resolved 25 January 2002
Engineering › Steering Gear System
Issued 10 January 2002 Resolved
Port rudder and skeg missing. Renew as per original IAW 46CFR176.700 & 176.800. LEGACY COMPONENT DESC: RUDDER
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 January 2002
Resolved 25 January 2002
Construction/Loadline › Hull
Issued 10 January 2002 Resolved
Port and Stbd hulls. Damage noted in various locations that penetrate the FRP into the wooden keel. Provide written repair plans for approval and effect permanent repairs as per approved plans NLT 30APR02 IAW 46CFR176.700. LEGACY COMPONENT DESC: Keel
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 April 2002
Resolved 8 May 2002
Resolution: Administravely closed case based on completion of of credit drydock.
Fire Fighting › Ventilation Systems
Issued 10 January 2002 Resolved
Provide vent closures or permanent repairs (remove vent and seal hole) to excess E/R vents IAW 46CFR182.465. Vessel must carry two additional B-II fire extinguishers until corrected.
Due 15 February 2002
Resolved 10 January 2002
Accommodation/Occupational Safety
Issued 28 November 2001 Resolved
Replace forward port and starboard windows and port outboard window of accomodation space in accordance with 46 CFR 177.1020.
Condition: Unknown
Due 12 December 2001
Resolved 12 December 2001
Resolution: Master replaced windows in accomodation space.
Documentation
Issued 7 March 2001 Resolved
Provide current FCC Safety Certificate in accordance with 46 CFR 184.502.
Condition: Unknown
Due 7 March 2001
Resolved 7 March 2001
Lifesaving
Issued 7 March 2001 Resolved
Provide waterlight for ring lifebuoy in accordance with 46 CFR 180.70.
Condition: Unknown
Due 7 March 2001
Resolved 7 March 2001
Documentation
Issued 10 February 2000 Resolved
Provide proof of Employee Assistance Program (EAP) meeting 46CFR16 NLT 17FEB00.
Condition: Unknown
Due 18 February 2000
Resolved 18 February 2000
Fire Fighting
Issued 11 January 2000 Resolved
Vessel failed to comply with CG-835 #1 of case MI99039165 to install a fixed fire fighting system in each engine room. Vessel's COI is revoked and must not operate under the authority of the COI IAW 46CFR176.100(a).
Condition: Unknown
Due 14 February 2000
Resolved 14 February 2000
Fire Fighting
Issued 23 December 1999 Resolved
Provide fixed firefighting system for each engine space & conduct system tests to the satisfaction of the Marine Inspector IAW 46CFR181.400 OR 181.420 NLT 7JAN00. Addititional portable fire extinguishers of adequate size & type for the space intended must be provided & mounted.
Condition: Unknown
Due 23 December 1999
Resolved 23 December 1999
Fire Fighting
Issued 23 December 1999 Resolved
Provide a provision to close all supply and exhaust ducts to each engine space IAW 46 CFR 182.465(h) NLT 7JAN00.
Condition: Unknown
Due 23 December 1999
Resolved 23 December 1999
Documentation
Issued 10 March 1999 Resolved
Provide EAP training as required by 46 CFR 16.
Condition: Unknown
Due 14 April 1999
Resolved 14 April 1999
Fire Fighting
Issued 10 March 1999 Resolved
Service 2 B-II extinguishers.
Condition: Unknown
Due 14 April 1999
Resolved 14 April 1999
Documentation
Issued 4 March 1998 Resolved
Provide evidence of an Employee Assistance Program._x001C_
Condition: Unknown
Due 4 March 1998
Resolved 4 March 1998
Construction/Loadline
Issued 4 March 1998 Resolved
Plug new through hull penetrations in the port center compartments.
Condition: Unknown
Due 4 March 1998
Resolved 4 March 1998
Unknown
Issued 4 March 1998 Resolved
Repair broken latch on port side forward hatch cover.
Condition: Unknown
Due 4 March 1998
Resolved 4 March 1998
Engineering
Issued 4 March 1998 Resolved
Reconnect s/w strainer for s/s generator.
Condition: Unknown
Due 4 March 1998
Resolved 4 March 1998
Documentation
Issued 4 March 1998 Resolved
Provide evidence of documented training for all employees on the company's Chemical Testing Program.
Condition: Unknown
Due 4 March 1998
Resolved 4 March 1998
Construction/Loadline
Issued 4 March 1998 Resolved
Plug disconnected through hull penetration for the sink in the stbd center compartment.
Condition: Unknown
Due 4 March 1998
Resolved 4 March 1998
Construction/Loadline
Issued 4 March 1998 Resolved
Repair or replace handle for sea valve for head in the stbd center compartment.
Condition: Unknown
Due 4 March 1998
Resolved 4 March 1998
Unknown
Issued 4 March 1998 Resolved
Properly mount maserator for head in stbd center compartment.
Condition: Unknown
Due 4 March 1998
Resolved 4 March 1998
Construction/Loadline
Issued 4 March 1998 Resolved
Provide proper handle for the manual bilge pump in stbd center compartment.
Condition: Unknown
Due 4 March 1998
Resolved 4 March 1998
Documentation
Issued 4 March 1998 Resolved
Provide a valid FCC operator's permit.
Condition: Unknown
Due 4 March 1998
Resolved 4 March 1998
Documentation
Issued 4 March 1998 Resolved
Conduct fire fighting drills and training and log same as required by 46 CFR 185.524.
Condition: Unknown
Due 4 March 1998
Resolved 4 March 1998
Documentation
Issued 4 March 1998 Resolved
Conduct monthly test of EPIRB and log same as required by 46 CFR 185.728.
Condition: Unknown
Due 4 March 1998
Resolved 4 March 1998
Documentation
Issued 18 April 1997 Resolved
Provide a log documenting crew training and drills, and lifesaving inspections.
Condition: Unknown
Due 18 April 1997
Resolved 18 April 1997
Documentation
Issued 18 April 1997 Resolved
Provide a valid FCC operators permit for each person who operates the VHF- FM radio.
Condition: Unknown
Due 18 April 1997
Resolved 18 April 1997
Construction/Loadline
Issued 18 April 1997 Resolved
Install a bilge pumping system for the port and stbd center compartments and the stbd forward compartment in accordance with 46 CFR 182.25.
Condition: Unknown
Due 18 April 1997
Resolved 18 April 1997
Documentation
Issued 18 April 1997 Resolved
Provide a valid Certificate of Documentation onboard.
Condition: Unknown
Due 18 April 1997
Resolved 18 April 1997
Lifesaving
Issued 18 April 1997 Resolved
Install a Category I 406 Mhz EPIRB in a float free arrangement.
Condition: Unknown
Due 18 April 1997
Resolved 18 April 1997
Construction/Loadline
Issued 18 April 1997 Resolved
Install securing devices for the port and stbd forward hatches, main deck.
Condition: Unknown
Due 18 April 1997
Resolved 18 April 1997
Deck/Cargo
Issued 18 April 1997 Resolved
Install cotter pins in turnbuckles for all shrouds and stays.
Condition: Unknown
Due 18 April 1997
Resolved 18 April 1997
Construction/Loadline
Issued 18 April 1997 Resolved
Repair as original, soft wood in decking in-way of chain plate and hatch coaming, forward port compartment.
Condition: Unknown
Due 18 April 1997
Resolved 18 April 1997
Engineering
Issued 18 April 1997 Resolved
Properly adjust the rear engine mounts for the stbd main engine. At least two threads should penetrate through the foundation nut.
Condition: Unknown
Due 18 April 1997
Resolved 18 April 1997
Electrical
Issued 18 April 1997 Resolved
Stbd 12 volt battery power supply overload protection bypassed. Properly correct the electrical fault and install the proper size overload protection in accordance with 46 CFR 183.05.
Condition: Unknown
Due 18 April 1997
Resolved 18 April 1997
Navigation
Issued 18 April 1997 Resolved
Renew wasted handle on the hydraulic bypass valve, stbd steering ram.
Condition: Unknown
Due 18 April 1997
Resolved 18 April 1997
Electrical
Issued 18 April 1997 Resolved
Properly install the proper size overload protection for the stbd engine room bilge pump.
Condition: Unknown
Due 23 April 1997
Resolved 23 April 1997
Navigation
Issued 18 April 1997 Resolved
Demonstrate proper operation of the VHF-FM radio. The vessel is restrictedto 1000 feet from shore until this item is corrected.
Condition: Unknown
Due 23 April 1997
Resolved 23 April 1997
Engineering
Issued 18 April 1997 Resolved
Renew the wasted and damaged throttle cable on the stbd main engine.
Condition: Unknown
Due 18 April 1997
Resolved 18 April 1997
Engineering
Issued 18 April 1997 Resolved
Provide vent closures for the vent openings in the generator space, and port and stbd engine rooms.
Condition: Unknown
Due 18 April 1997
Resolved 18 April 1997
Construction/Loadline
Issued 18 April 1997 Resolved
Renew broken bilge pump float switch, port forward compartment.
Condition: Unknown
Due 23 April 1997
Resolved 23 April 1997
Accommodation/Occupational Safety
Issued 18 April 1997 Resolved
Install hand rails on all weather decks accessible to passengers and crew in accordance with 46 CFR 177.35-1.
Condition: Unknown
Due 18 April 1997
Resolved 18 April 1997
Construction/Loadline
Issued 18 April 1997 Resolved
Permanently repair fracture in the main deck to house front connection, stbd side.
Condition: Unknown
Due 18 April 1997
Resolved 18 April 1997
Engineering
Issued 18 April 1997 Resolved
Renew the broken engine shutdown cables on both main engines.
Condition: Unknown
Due 18 April 1997
Resolved 18 April 1997
Engineering
Issued 18 April 1997 Resolved
Renew the chafed and deteriorated fuel return hose with an approved type, stbd main engine.
Condition: Unknown
Due 18 April 1997
Resolved 18 April 1997
Construction/Loadline
Issued 6 June 1996 Resolved
INSTALL SECURING DEVICES FOR BOTH ENGINE ROOM HATCHES.
Condition: Unknown
Due 6 June 1996
Resolved 6 June 1996
Lifesaving
Issued 3 April 1996 Resolved
Provide manufacturer maintenance instructions for the survival craft in accordance with 46 CFR 185.702.
Condition: Unknown
Due 3 April 1996
Resolved 3 April 1996
Lifesaving
Issued 3 April 1996 Resolved
Conduct and log weekly maintenance and inspection of the survival craft in accordance with 46 CFR 185.720.
Condition: Unknown
Due 3 April 1996
Resolved 3 April 1996
Lifesaving
Issued 3 April 1996 Resolved
Conduct and log monthly inspection of the survival craft in accordance with46 CFR 185.722.
Condition: Unknown
Due 3 April 1996
Resolved 3 April 1996
Construction/Loadline
Issued 3 April 1996 Resolved
Properly label vessel's name and hailing port on the vessel's stern.
Condition: Unknown
Due 3 April 1996
Resolved 3 April 1996
Engineering
Issued 3 April 1996 Resolved
Double hose clamp fuel supply hoses for the SSDG.
Condition: Unknown
Due 3 April 1996
Resolved 3 April 1996
Electrical
Issued 3 April 1996 Resolved
New electrical wiring for bilge system must be installed in accordance with46 CFR 183.340.
Condition: Unknown
Due 3 April 1996
Resolved 3 April 1996
Accommodation/Occupational Safety
Issued 3 April 1996 Resolved
Provide a valid copy of the vessel's State of Hawaii Department of Health Food Service and Food Establishment Permit.
Condition: Unknown
Due 3 April 1996
Resolved 3 April 1996
Construction/Loadline
Issued 3 April 1996 Resolved
Install bilge pumps, piping, valves, controls, and indicators for the port and stbd center compartments and the stbd forward compartment in accordancewith 46 CFR 182.500 and 46 CFR 182.520. All bilge pump controls (includingthe E/R bilge pumps) must be located at a central control point.
Condition: Unknown
Due 3 April 1996
Resolved 3 April 1996
Lifesaving
Issued 3 April 1996 Resolved
Provide copies of passenger count lists in accordance with 46 CFR 185.504.
Condition: Unknown
Due 3 April 1996
Resolved 3 April 1996
Lifesaving
Issued 3 April 1996 Resolved
Conduct passenger safety orientation in accordance with 46 CFR 185.506.
Condition: Unknown
Due 3 April 1996
Resolved 3 April 1996
Lifesaving
Issued 3 April 1996 Resolved
Conduct and log abandon ship and man overboard drills and training in accordance with 46 CFR 185.520.
Condition: Unknown
Due 3 April 1996
Resolved 3 April 1996
Fire Fighting
Issued 3 April 1996 Resolved
Conduct and log fire fighting drills and training in accordance with 46 CFR185.524.
Condition: Unknown
Due 3 April 1996
Resolved 3 April 1996
Navigation
Issued 3 April 1996 Resolved
Post a radio emergency broadcast placard in accordance with 46 CFR 184.506.
Condition: Unknown
Due 3 April 1996
Resolved 3 April 1996
Lifesaving
Issued 3 April 1996 Resolved
Conduct and log crew training in accordance with 46 CFR 185.420.
Condition: Unknown
Due 3 April 1996
Resolved 3 April 1996
Construction/Loadline
Issued 3 April 1996 Resolved
Permanently seal holes in transom where ladder was removed, or reinstall ladder, port hull.
Condition: Unknown
Due 3 April 1996
Resolved 3 April 1996
Construction/Loadline
Issued 3 April 1996 Resolved
Properly label watertight hatches in accordance with 46 CFR 185.610.
Condition: Unknown
Due 3 April 1996
Resolved 3 April 1996
Engineering
Issued 3 April 1996 Resolved
Permanently repair wasted and leaking metallic exhaust elbow on the stbd MDE.
Condition: Unknown
Due 3 April 1996
Resolved 3 April 1996
Construction/Loadline
Issued 3 April 1996 Resolved
In lieu of plastic tubing, install with double hose clamps on the dischargeside of the port and stbd engine room bilge pumps, heavy duty flex hose highly resistant to S/W, petroleum, heat, and vibration in accordance with 46 CFR 182.520.
Condition: Unknown
Due 3 April 1996
Resolved 3 April 1996
Electrical
Issued 3 April 1996 Resolved
Provide portable lights in accordance with 46 CFR 183.430.
Condition: Unknown
Due 3 April 1996
Resolved 3 April 1996
Engineering
Issued 3 April 1996 Resolved
Properly support and secure S/W piping to the stbd MDE.
Condition: Unknown
Due 9 April 1996
Resolved 9 April 1996
Engineering
Issued 3 April 1996 Resolved
Double hose clamp S/W hoses to the stbd MDE and stbd propeller shaft stuffing box.
Condition: Unknown
Due 9 April 1996
Resolved 9 April 1996
Electrical
Issued 3 April 1996 Resolved
Install, located at the battery, an emergency disconnect switch for the stbd 12 volt battery.
Condition: Unknown
Due 3 April 1996
Resolved 3 April 1996
Construction/Loadline
Issued 3 April 1996 Resolved
Permanently restore to original strength, soft wood in inboard side shell stringers and hatch coamings in the port and stbd engine rooms.
Condition: Unknown
Due 3 April 1996
Resolved 3 April 1996
Construction/Loadline
Issued 3 April 1996 Resolved
Provide high bilge level alarms (audible and visual at the helm) for each compartment (total of six) in accordance with 46 CFR 182.530.
Condition: Unknown
Due 3 April 1996
Resolved 3 April 1996
Construction/Loadline
Issued 3 April 1996 Resolved
Install, at the through hull fitting, a bronze positive shutoff valve for the bilge pump discharge line and install at the helm bilge pump controls and indicator lights for the SSDG compartment bilge pump, and the port and stbd engine room bilge pumps in accordance with 46 CFR 182.500 and 182.520
Condition: Unknown
Due 3 April 1996
Resolved 3 April 1996
Electrical
Issued 3 April 1996 Resolved
Electrically bond the port MDE and SSDG S/W inlet valves, port and stbd fuel tanks, and port and stbd fuel fill hoses.
Condition: Unknown
Due 3 April 1996
Resolved 3 April 1996
Engineering
Issued 7 March 1996 Resolved
Renew muffler exhaust hose for starboard main engine where ply is damaged(last section of the hose)._x001C_
Condition: Unknown
Due 7 March 1996
Resolved 7 March 1996
Documentation
Issued 7 March 1996 Resolved
PROVIDE EMPLOYEE ACKNOWLEDGEMENTS FOR CHEMICAL TESTING PROGRAM.
Condition: Unknown
Due 7 March 1996
Resolved 7 March 1996
Lifesaving
Issued 7 March 1996 Resolved
RENEW REFLECTIVE TAPE ON BUOYANT APPARATUS.
Condition: Unknown
Due 7 March 1996
Resolved 7 March 1996
Lifesaving
Issued 7 March 1996 Resolved
FRESHEN MARKINGS ON BUOYANT APPARATUS AND RING BUOY.
Condition: Unknown
Due 7 March 1996
Resolved 7 March 1996
Lifesaving
Issued 7 March 1996 Resolved
PROVIDE EVIDENCE OF 1)CLEANING OF BEVERAGE HOSES AND 2) REGULAR MAINTENANCEOF BEVERAGE HOSES.
Condition: Unknown
Due 7 March 1996
Resolved 7 March 1996
Construction/Loadline
Issued 7 March 1996 Resolved
PROVIDE FASTENERS FOR EXPOSED HATCHES AS NEEDED.
Condition: Unknown
Due 7 March 1996
Resolved 7 March 1996
Fire Fighting
Issued 7 March 1996 Resolved
PROVIDE 1 B I AND 4 B II EXTINGUISHER PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 7 March 1996
Resolved 12 March 1996
Documentation
Issued 7 March 1996 Resolved
PROVIDE SUBCHAPTER "T", NAVRULES, LIGHT LIST, COAST PILOT, TIDE TABLES AND CHARTS.
Condition: Unknown
Due 7 March 1996
Resolved 7 March 1996
Engineering
Issued 7 March 1996 Resolved
Replace fuel hoses (flexible) with type which meet ASTM 1692. Return line hose on starboard engine is cracked.
Condition: Unknown
Due 7 March 1996
Resolved 7 March 1996
Unknown
Issued 7 March 1996 Resolved
Complete to the satisfaction of the attending Coast Guard Marine Inspector emergency fire, heavy weather, man overboard and flooding drills.
Condition: Unknown
Due 7 March 1996
Resolved 7 March 1996
Documentation
Issued 7 March 1996 Resolved
PROVIDE WASTE MANAGEMENT PLANS.
Condition: Unknown
Due 7 March 1996
Resolved 7 March 1996
Documentation
Issued 7 March 1996 Resolved
PROVIDE EVIDENCE OF 60 MINUTES OF SUPERVISOR TRAINING.
Condition: Unknown
Due 7 March 1996
Resolved 7 March 1996
Documentation
Issued 7 March 1996 Resolved
PROVIDE VALID SCIENTIFIC RANDOM CHEMICAL TESTING METHOD.
Condition: Unknown
Due 7 March 1996
Resolved 7 March 1996
Lifesaving
Issued 7 March 1996 Resolved
RENEW BUOYANT APPARATUS PENDANTS AS NEEDED.
Condition: Unknown
Due 7 March 1996
Resolved 7 March 1996
Documentation
Issued 7 March 1996 Resolved
PROVIDE TRASH LOG.
Condition: Unknown
Due 7 March 1996
Resolved 7 March 1996
Lifesaving
Issued 7 March 1996 Resolved
RENEW REFLECTIVE TAPE ON PFD'S AS NEEDED.
Condition: Unknown
Due 7 March 1996
Resolved 7 March 1996
Documentation
Issued 7 March 1996 Resolved
PROVIDE EMPLOYEE ASSISTANCE PROGRAM.
Condition: Unknown
Due 7 March 1996
Resolved 7 March 1996
Engineering
Issued 7 March 1996 Resolved
REINSTALL INLET STRAINER FOR THE STARBOARD MAIN ENGINE COOLING WATER INLET.
Condition: Unknown
Due 7 March 1996
Resolved 7 March 1996
Engineering
Issued 7 March 1996 Resolved
RENEW STARBOARD SIDE FLAME SCREEN FOR FUEL TANK VENT.
Condition: Unknown
Due 7 March 1996
Resolved 7 March 1996
Engineering
Issued 7 March 1996 Resolved
PROVE OPERATION OF FUEL TANK SHUT OFF FOR PORT SIDE.
Condition: Unknown
Due 7 March 1996
Resolved 7 March 1996
Engineering
Issued 7 March 1996 Resolved
TIGHTEN PORT MAIN ENGINE INBOARD MOUNT.
Condition: Unknown
Due 7 March 1996
Resolved 7 March 1996
Engineering
Issued 7 March 1996 Resolved
Provide flame shield for port RACOR filter and renew plactic nut and belt on the starboard RACOR filter with metallic nut and belt.
Condition: Unknown
Due 7 March 1996
Resolved 7 March 1996
Engineering
Issued 7 March 1996 Resolved
FUEL RETURN LINE CONNECTION PORT SIDE, HOSE NEEDS TO BE REPLACED.
Condition: Unknown
Due 7 March 1996
Resolved 7 March 1996
Lifesaving
Issued 7 March 1996 Resolved
REMOVE OIL FROM ALL MACHINERY SPACE BILGES.
Condition: Unknown
Due 7 March 1996
Resolved 7 March 1996
Lifesaving
Issued 7 March 1996 Resolved
PROVIDE 3 ADDITIONAL RED FLARES.
Condition: Unknown
Due 7 March 1996
Resolved 7 March 1996
Construction/Loadline
Issued 7 March 1996 Resolved
MAKE PROPER ELECTRICAL CONNECTIONS FOR THE STARBOARD MAIN ENGINE ROOM BILGEPUMP.
Condition: Unknown
Due 7 March 1996
Resolved 7 March 1996
Construction/Loadline
Issued 7 March 1996 Resolved
Have both bilge pump overboards fitted with non return valves and have bilge system fitted indicator lights at console to indicate when the pumps are operating._x001C_
Condition: Unknown
Due 7 March 1996
Resolved 7 March 1996
Construction/Loadline
Issued 13 September 1995 Resolved
PROVIDE DEAD COVERS IAW 46 CFR 171.119 TO ALL OPENING PORT LIGHTS TO THE SATISFACTION OF A CG MARINE INSPECTOR.
Condition: Unknown
Due 13 September 1995
Resolved 13 September 1995
Construction/Loadline
Issued 13 September 1995 Resolved
REPLACE BACKING PLATES TO STB TRANSOM LADDER TO THE SATISFACTION OF A CG MARINE INSPECTOR. LADDER NOT TO BE USED BY PASSENGERS UNTIL REPAIRS ARE SATISFACTORILY COMPLETED.
Condition: Unknown
Due 13 September 1995
Resolved 13 September 1995
Construction/Loadline
Issued 13 September 1995 Resolved
INSTALL VENT PIPE IN PORT ENGINE ROOM TO THE SATISFACTION OF A CG MARINE INSPECTOR PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 13 September 1995
Resolved 13 September 1995
Deck/Cargo
Issued 13 September 1995 Resolved
REPLACE DAMAGED DANFORTH ANCHOR TO THE SATISFACTION OF A CG MARINE INSPECTOR PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 13 September 1995
Resolved 13 September 1995
Construction/Loadline
Issued 13 September 1995 Resolved
ATTACH VENT PIPE TO HULL OPENING IN THE STB ENGINE ROOM TO THE SATISFACTIONOF A CG MARINE INSPECTOR PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 13 September 1995
Resolved 13 September 1995
Construction/Loadline
Issued 4 March 1995 Resolved
REPAIR CRACK IN STARBOARD SPONSON, FORWARD, INBOARD.
Condition: Unknown
Due 4 March 1995
Resolved 4 March 1995
Construction/Loadline
Issued 4 March 1995 Resolved
REFASTEN AFT STARBOARD CLEAT IN ACCORDANCE WITH 46 CFR 176.39-1.
Condition: Unknown
Due 4 March 1995
Resolved 4 March 1995
Lifesaving
Issued 4 March 1995 Resolved
PROVIDE 60 FEET OF LINE FOR RING BUOY IN ACCORDANCE WITH 46 CFR 180.30-1.
Condition: Unknown
Due 4 March 1995
Resolved 4 March 1995
Lifesaving
Issued 4 March 1995 Resolved
RENEW STENCIL FOR TOTAL NUMBER OF PEOPLE, TWO BUOYANT APPARATUSES IN ACCORDANCE WITH 46 CFR 180.20-5.
Condition: Unknown
Due 22 March 1995
Resolved 22 March 1995
Construction/Loadline
Issued 4 March 1995 Resolved
SUBMIT BILGE SYSTEM PLANS FOR APPROVAL, IN ACCORDANCE WITH 46 CFR 182.25-5.WORK TO THIS SYSTEM IS TO BE COMPLETED PRIOR TO COMPLETION OF CREDITED DRYDOCK.
Condition: Unknown
Due 20 March 1995
Resolved 20 March 1995
Navigation
Issued 4 March 1995 Resolved
MAKE REPAIR TO NAVIGATIONAL LIGHTS. VESSEL RESTRICTED TO DAYLIGHT OPERATION UNTIL INSPECTED AND APPROVED BY THE ON SCENE COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 22 March 1995
Resolved 22 March 1995
Documentation
Issued 4 March 1995 Resolved
PROVIDE PRE EMPLOYMENT DRUG TESTING RESULTS.
Condition: Unknown
Due 22 March 1995
Resolved 22 March 1995
Documentation
Issued 4 March 1995 Resolved
PROVIDE PREVENTATIVE MAINTENANCE MANUAL FOR VESSEL. TO BE BROKEN DOWN INTO3 MONTH INTERVALS INCLUDING LIFE SAVING, MACHINERY, ELECTRICAL AND RIGGING.
Condition: Unknown
Due 20 March 1995
Resolved 20 March 1995
Engineering
Issued 5 March 1992 Resolved
RENEW THE INOPERATIVE PORT OIL PRESSURE GAUGE ON THE HELM CONSOLE.
Condition: Unknown
Due 5 March 1992
Resolved 5 March 1992
Electrical
Issued 5 March 1992 Resolved
PROPERLY MOUNT THE LOOSE BATTERY SELECTOR SWITCH IN THE PORT ENGINE SPACE.
Condition: Unknown
Due 5 March 1992
Resolved 5 March 1992
Engineering
Issued 5 March 1992 Resolved
PROVIDE A 30X30 SIZE FLAME SCREEN FOR THE PORT ENGINE FUEL VENT. (FORWARD VENT PORT).
Condition: Unknown
Due 5 March 1992
Resolved 5 March 1992
Accommodation/Occupational Safety
Issued 5 March 1992 Resolved
PROVIDE PROPER COURSES FOR THE PASSENGER RAIL AFT OF THE HELM IN ACCORDANCEWITH 46 CFR 177.35.
Condition: Unknown
Due 5 March 1992
Resolved 5 March 1992
Lifesaving
Issued 5 March 1992 Resolved
PROPERLY LABEL ALL OF THE PFD STORAGE AREAS INDICATING THE NUMBER AND TYPE (ADULT/CHILD) IN EACH LOCATION.
Condition: Unknown
Due 5 March 1992
Resolved 5 March 1992
Lifesaving
Issued 5 March 1992 Resolved
PROPERLY STENCIL THE VESSEL NAME ON BOTH BUOYANT APARATUSES.
Condition: Unknown
Due 5 March 1992
Resolved 5 March 1992
Engineering
Issued 21 September 1990 Resolved
INSTALL A SUITABLE MARINE TYPE F/O STRAINER IN THE PORT HULL FOR THE AUX GENERATOR. REF CFR182.20-40(5).
Condition: Unknown
Due 21 September 1990
Resolved 21 September 1990
Lifesaving
Issued 21 September 1990 Resolved
VESSELS PRIMARY LIFESAVING NEEDS REPLACEMENT. NEW 18 PERSON B.A. REQUIRED (2EA), VSL IS RESTRICTED TO OPERATE NO MORE THAN ONE MILE FROM SHORE UNTIL LIFESAVING EQUIPMENT IS INSTALLED.
Condition: Unknown
Due 21 September 1990
Resolved 21 September 1990
Construction/Loadline
Issued 21 September 1990 Resolved
MAKE PERMANENT REPAIRS TO FRACTURED FRAME IN STBD HULL ENGINE COMPARTMENT (6TH FRAME FROM AFT BULKHEAD ON STBD SIDE BY ENGINE MOUNT).
Condition: Unknown
Due 21 September 1990
Resolved 21 September 1990
Engineering
Issued 21 September 1990 Resolved
INSTALL DRIP PAN W/METALLIC PLUG ON THE PORT M.D.E F/O FILTER. REF 46CFR181.20-40(5).
Condition: Unknown
Due 21 September 1990
Resolved 21 September 1990
Engineering
Issued 21 September 1990 Resolved
INSTALL SUITABLE FLEXIABLE HOSE WHICH IS RESISTANT TO DIESEL FUEL OIL ON THE PORT AND STBD FILL. REF 46CFR182.20-30(D).
Condition: Unknown
Due 21 September 1990
Resolved 21 September 1990
Construction/Loadline
Issued 22 September 1988 Resolved
PROVIDE A SUCTION AND DISCHARGE HOSE FOR THE PORT MAIN COMPANIONWAY COMPARTMENT FIXED HAND BILGE PUMP PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 22 September 1988
Resolved 22 September 1988
Engineering
Issued 22 September 1988 Resolved
MAKE PERMANENT REPAIRS TO THE STARBOARD FUEL TANK EMERGENCY FUEL SHUTOFF PULL CABLE SYSTEM PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 22 September 1988
Resolved 22 September 1988
Engineering
Issued 22 September 1988 Resolved
REPLACE A NON METALLIC FUEL HOSE WITH USCG ACCEPTED NON METALLIC FUEL HOSE OR USCG TYPE A FUEL HOSE.
Condition: Unknown
Due 22 September 1988
Resolved 22 September 1988
Unknown
Issued 26 October 1984 Resolved
PROVIDE THREE (3) APPROVED HAND HELD RED DISTRESS FLARES.
Condition: Unknown
Due 26 October 1984
Resolved 26 October 1984

Casualty record · 1

7 June 2003Routine · role: Involved in a Marine Casualty · 2 injured · activity 1903014
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.