MAURY USCG vessel records Sign in
← All vessels

NEW ORLEANS

NEW ORLEANS is a 1985 passenger vessel (inspected). The Coast Guard has recorded 30 inspections since 1985, most recently in September 2007, along with 41 deficiencies.

Records from 1985 to 2007. Most recent: inspection, 6 September 2007.

Built
1985
Last inspected
6 September 2007
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

237011
Flag
UNITED STATES
—
Maury page id
psix-237011

Inspections, by type

…with no type recorded11
Years with a record 5 calendar years (1985–2007)
The 30 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it61 - Regulatory (Subpart C or D), Net Ton
90 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 30

6 September 2007 Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3050879
1 June 1988 Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1045368
28 May 1988 Deficiency Check
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 886993
13 May 1988 COI Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1349060
21 January 1988 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1012787
16 October 1987 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1015799
24 September 1987 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1011172
28 July 1987 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1331477
12 June 1987 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1337799
2 June 1987 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1028537
19 May 1987 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1333765
8 April 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1022798
22 January 1987 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1009726
6 January 1987 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1315898
10 December 1986 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1312874
25 August 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1299167
23 August 1986 Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1312619
2 July 1986 Damage Survey · Examination of Repairs
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1293298
20 June 1986 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1305804
16 May 1986 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 994534
10 December 1985 Examination of Repairs
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 985495
21 October 1985 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1298404
13 September 1985 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1297302
7 September 1985 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1296530
6 September 1985 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1295814
3 August 1985 Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1291714
1 August 1985 Damage Survey
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 983958
30 July 1985 Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 981971
12 July 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 979926
12 June 1985 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 979613

Deficiency record · 41

Fire Fighting
Issued 13 May 1988 Resolved
PROVIDE PRINTS OF WIRING AND LOCATION OF GENERAL ALARMS. EACH ALARM SHALL BE INDICATED FROM THE ALARM TO POWER SOURCE.
Condition: Unknown
Due 13 May 1988
Resolved 13 May 1988
Construction/Loadline
Issued 13 May 1988 Resolved
REPLACE GASKET ON AFTER STEERING HATCH.
Condition: Unknown
Due 13 May 1988
Resolved 13 May 1988
Accommodation/Occupational Safety
Issued 13 May 1988 Resolved
HAVE GALLEY AVAILABLE FOR SANITATION INSPECTION.
Condition: Unknown
Due 13 May 1988
Resolved 13 May 1988
Fire Fighting
Issued 13 May 1988 Resolved
PROVIDE TWO (2) APPROVED 50 FOOT LENGTHS OF FIRE HOSE TO MEET CERTIFICATE OF INSPECTION REQUIREMENTS.
Condition: Unknown
Due 13 May 1988
Resolved 13 May 1988
Fire Fighting
Issued 13 May 1988 Resolved
REPAIR OR REPLACE NUMBER TWO (2) FIRE PUMP.
Condition: Unknown
Due 13 May 1988
Resolved 13 May 1988
Electrical
Issued 13 May 1988 Resolved
LOCATE AND REPAIR LUBE OIL LEAKS ON NUMBER ONE (1) GENERATOR.
Condition: Unknown
Due 13 May 1988
Resolved 13 May 1988
Lifesaving
Issued 13 May 1988 Resolved
PROVIDE DOCUMENTATION OF FLOAT-FREE LEAK FOR PORT BUOYANT APPARATUS.
Condition: Unknown
Due 13 May 1988
Resolved 13 May 1988
Electrical
Issued 16 October 1987 Resolved
PROVIDE PRINTS OF WIRING AND LOCATION OF GENERAL ALARMS. EACH ALARM SHALL BE INDICATED FROM THE ALARM TO ITS POWER SOURCE.
Condition: Unknown
Due 16 October 1987
Resolved 16 October 1987
Unknown
Issued 2 June 1987 Resolved
MAKE POTABLE WATER TANKS AVAILABLE FOR INTERNAL INSPECTION BY COAST GUARD MARINE INSPECTOR AT NEXT DRY DOCKING OF VESSEL.
Condition: Unknown
Due 30 June 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 19 May 1987 Resolved
PROVIDE GENERAL ALARM BELL IN STORES SPACE BELOW MAIN DECK.
Condition: Unknown
Due 19 May 1987
Resolved 19 May 1987
Construction/Loadline
Issued 19 May 1987 Resolved
PROVIDE CLOSURE DEVICES FOR ALL GOOSE NECK VENTS ON MAIN DECK. COMPLIANCE DATE IS 19JUN87.
Condition: Unknown
Due 19 May 1987
Resolved 19 May 1987
Construction/Loadline
Issued 19 May 1987 Resolved
PROVIDE DRAFT MARKS PORT & STBD, FORE & AFT. PERMANENTLY AFFIXED.
Condition: Unknown
Due 19 May 1987
Resolved 19 May 1987
Fire Fighting
Issued 23 August 1986 Resolved
PROPERLY SECURE BATTERIES FOR FIRE ALARM. COMPLIANCE DATE IS 23SEP86.
Condition: Unknown
Due 23 August 1986
Resolved 23 August 1986
Fire Fighting
Issued 23 August 1986 Resolved
LABEL ENGINE ROOM FIRE ALARM SOUNDING DEVICES, ON BRIDGE AND OUTSIDE ENGINE ROOM. COMPLIANCE DATE IS 23SEP86.
Condition: Unknown
Due 23 August 1986
Resolved 23 August 1986
Fire Fighting
Issued 2 July 1986 Resolved
PROVIDE HEAT AND SMOKE DETECTORS IN ENGINE ROOM. COMPLIANCE DATE IS 02AUG86.
Condition: Unknown
Due 2 July 1986
Resolved 2 July 1986
Engineering
Issued 16 May 1986 Resolved
REPAIR EXHAUST PIPING HANGER #1 MAIN DIESEL ENGINE.
Condition: Unknown
Due 16 May 1986
Resolved 16 May 1986
Electrical
Issued 16 May 1986 Resolved
PROVIDE HANGERS FOR EXPANSION TANK PIPING FOR #1, #2 AND #3 SHIPS SERVICE GENERATORS.
Condition: Unknown
Due 16 May 1986
Resolved 16 May 1986
Engineering
Issued 16 May 1986 Resolved
REPAIR LEAKS IN FUEL OIL PIPING IN WAY OF THE OVERHEAD, AFT OF FWD BULKHEADENGINEROOM.
Condition: Unknown
Due 16 May 1986
Resolved 16 May 1986
Engineering
Issued 16 May 1986 Resolved
REPAIR GENERATOR AIR COMPRESSOR UNLOADING VALVE CONTROLLER.
Condition: Unknown
Due 16 May 1986
Resolved 16 May 1986
Electrical
Issued 16 May 1986 Resolved
PROVIDE LAGGING FOR TURBO CHARGER AND EXHAUST MANIFOLD ON #2 SHIPS SERVICE GENERATOR.
Condition: Unknown
Due 16 May 1986
Resolved 16 May 1986
Engineering
Issued 16 May 1986 Resolved
REPAIR LEAK IN EXHAUST PIPING ON #1 MAIN DIESEL ENGINE.
Condition: Unknown
Due 16 May 1986
Resolved 16 May 1986
Electrical
Issued 16 May 1986 Resolved
MARK GENERAL ALARM BELLS TO READ AS SUCH: "GENERAL ALARM - WHEN BELL SOUNDSGO TO YOUR STATION". LETTERS TO BE AT LEAST 1/2" HIGH
Condition: Unknown
Due 16 May 1986
Resolved 16 May 1986
Electrical
Issued 16 May 1986 Resolved
PROVIDE A GENERAL ALARM BELL IN THE DINING AREA.
Condition: Unknown
Due 16 May 1986
Resolved 16 May 1986
Electrical
Issued 16 May 1986 Resolved
INSTALL SWITCHBOARD MAIN BREAKER INTERLOCK.
Condition: Unknown
Due 16 May 1986
Resolved 16 May 1986
Electrical
Issued 16 May 1986 Resolved
PROVIDE GENERATOR STARTING BATTERY BOX LINER.
Condition: Unknown
Due 16 May 1986
Resolved 16 May 1986
Electrical
Issued 16 May 1986 Resolved
PROVIDE PROPER OPERATION OF GROUND FAULT DETECTION SYSTEM.
Condition: Unknown
Due 16 May 1986
Resolved 16 May 1986
Electrical
Issued 16 May 1986 Resolved
PROVE PROPER OPERATION OF ENGINEROOM BILGE ALARM.
Condition: Unknown
Due 16 May 1986
Resolved 16 May 1986
Electrical
Issued 16 May 1986 Resolved
DEMONSTRATE OVERSPEED TRIPS ON #1, #2, AND #3 SHIPS SERVICE GENERATORS.
Condition: Unknown
Due 16 May 1986
Resolved 16 May 1986
Electrical
Issued 16 May 1986 Resolved
REPAIR LUBE OIL STARTING INTERLOCK ON # SHIPS SERVICE GENERATOR.
Condition: Unknown
Due 16 May 1986
Resolved 16 May 1986
Engineering
Issued 6 September 1985 Resolved
REMOVE PLASTIC DRUMS OF WASTE OIL AND AEROSOL CANS OF ENGINE DEGREASER FROMENGINE ROOM.
Condition: Unknown
Due 6 September 1985
Resolved 6 September 1985
Accommodation/Occupational Safety
Issued 6 September 1985 Resolved
THOROUGHLY CLEAN GALLEY CABINETS,WALLS, AND DECKS.
Condition: Unknown
Due 6 September 1985
Resolved 6 September 1985
Construction/Loadline
Issued 6 September 1985 Resolved
MARK ON ALL ACCOMMODATION SPACE EXIT DOORS AT ENDS OF PASSAGEWAYS AND ALL MAIN EXITS "EMERGENCY EXIT- KEEP CLEAR" IN ONE INCH CONTRASTING LETTERS
Condition: Unknown
Due 6 September 1985
Resolved 6 September 1985
Lifesaving
Issued 6 September 1985 Resolved
POST EMERGENCY CHECK OFF PROCEDURES IN ALL COMMON PASSENGER LOUNGE AREAS.
Condition: Unknown
Due 6 September 1985
Resolved 6 September 1985
Accommodation/Occupational Safety
Issued 3 August 1985 Resolved
PROVIDE OFFICER IN CHARGE MARINE INSPECTION OFFICE NEW ORLEANS WITH COAST GUARD APPROVED PLANS FOR ENGINE ROOM VENTING PLANS ARE TO BE SUBMITTED BY 17 AUGUST 1985 TO [name withheld].
Condition: Unknown
Due 3 August 1985
Resolved 3 August 1985
Unknown
Issued 3 August 1985 Resolved
THE FOLLOWING DEFICIENCIE PERTAINS TO THE VESSEL NEW ORLEANS, DN684189.
Condition: Unknown
Due 3 August 1985
Resolved 3 August 1985
Unknown
Issued 1 August 1985 Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL NEW ORLEANS, DN684189.
Condition: Unknown
Due 1 August 1985
Resolved 1 August 1985
Construction/Loadline
Issued 1 August 1985 Resolved
MAKE PERMANENT REPAIRS TO HOLES IN MAIN DECK IN WAY OF THE BITT ON THE STARBOARD AFT QUARTER, PRIOR TO DEPARTING NEW ORLEANS, LA AND WITHIN SEVEN (7) DAYS IN NO CASE LATER THAN 8 AUGUST 1985 TO THE SATISFACTION OF THE ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 1 August 1985
Resolved 1 August 1985
Unknown
Issued 1 August 1985 Resolved
MAKE PERMANENT REPAIRS TO MAIN DECK STANCHIONS (5) IN WAY OF THE STARBOARD SIDE OF MAIN DECK WITHIN SEVEN (7) DAYS AND PRIOR TO DEPARTING NEW ORLEANS,LA AND IN NO CASE LATER THAN 8 AUGUST 1985 TO THE SATISFACTION OF THE ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 1 August 1985
Resolved 1 August 1985
Electrical
Issued 1 August 1985 Resolved
PROVIDE AND INSTALL EMERGENCY LIGHTING IN WAY OF THE GALLEY/MESS DECK AREA TO THE SATISFACTION OF THE COGNIZANT OFFICER IN CHARGE MARINE INSPECTOR WITHIN THIRTY (30) DAYS IN NO CASE LATER THAN 31 AUGUST 1985.
Condition: Unknown
Due 1 August 1985
Resolved 1 August 1985
Unknown
Issued 30 July 1985 Resolved
GAS-FREE ALL ACCESSIBLE VOIDS AND EMPTY TANKS AND PRESENT VESSEL IN VICKSBURG, MS. FOR INTERNAL EXAM BY A COAST GUARD INSPECTOR TO CHECK FOR DAMAGES FROM GROUNDING AT MILE 540 L.M.R. THE ABOVE TO BE COMPLETED TO THE SATISFACTION OF COGNIZANT OCMI PRIOR TO 01AUG85.
Condition: Unknown
Due 30 July 1985
Resolved 30 July 1985
Electrical
Issued 12 June 1985 Resolved
E-1. COMPLETE ELECTRICAL INSTALLATIONS AND MAKE ACCESSIBLE FOR COAST GUARDINSPECTION PRIOR TO THE VESSEL'S DEPARTURE FROM SALISBURY, MD, BUT IN NO CASE LATER THAN 18JUN85.
Condition: Unknown
Due 12 June 1985
Resolved 12 June 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.