Inspection history · 18
5 March 2025
Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8088510
24 January 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7854188
9 January 2024
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7845362
24 April 2023
In-Service Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7674354
3 January 2023
MTSA Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7609100
20 January 2022
Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7382864
6 January 2022
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7376380
6 January 2022
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7376393
20 January 2021
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7126858
24 February 2020
Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6914296
19 February 2020
Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6911355
12 February 2019
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6626317
1 February 2018
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6362068
9 January 2018
Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6334528
12 September 2017
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6271179
31 January 2017
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6080109
4 February 2016
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5819949
5 January 2016
Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5790960
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 5 March 2025
No resolution recorded
The owner, charterer, master, or managing operator shall instruct each crew member, upon first being employed and prior to getting underway for the first time on a particular vessel and at least once every three months, as to the duties that the crew member is expected to perform in an emergency including, but not limited to, the emergency instructions listed on the emergency instruction placard required by § 122.510, when applicable, the duties listed in the station bill required by § 122.514. Did not conduct drills during annual exam. Perform crew drills in the presence of attending MI.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 March 2025
No resolution recorded
Each individual bilge suction must be fitted with a suitable strainer having an open area of not less than three times that of the suction pipe. In addition, a mud box or basket strainer must be fitted in an accessible position between the bilge suction manifold and the pump. MI observed bilge suction strainer in void space #3 deteriorated. Renew as original.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 5 March 2025
No resolution recorded
Doors in A-Class fire control boundaries must meet the following additional requirements:
(1) A door in a bulkhead required to be A-60, A-30, or A-15 Class must be of hollow steel or equivalent material construction, solidly filled with approved structural insulation, and capable of meeting the requirements of an A-15 Class bulkhead"
MI observed fire door between machinery and engine room not meeting fire control boundary with 1/2 inch gap under fire door. Submit repair plan.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 March 2025
No resolution recorded
Each portable fire extinguisher on a vessel must be of a type approved by the Commandant. The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant OCMI, but must be not less than the minimum number required by table 1 to § 118.500(b) and other provisions of this section. 03 portable fire extinguishers removed for hydrostatic testing.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 January 2024
Resolved
All pressure vessels other than unfired steam boilers shall be protected by pressure relieving devices. The pressure vessel in the pilot house does not have a pressure relief valve.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2024
Resolved 22 January 2024
Resolution: The operator added the required pressure relieving device on the pressure vessel.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 9 January 2024
Resolved
Batteries shall be secured against shifting with motion of the boat. The battery located in the pilot house under the helm were not secured to prevent movement. 46 CFR 183.05-20(b) OLD T
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2024
Resolved 22 January 2024
Resolution: The operator secured the battery to prevent movement.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 9 January 2024
Resolved
Double doors capable of independent operation and latching may have a clearance between the doors of not more than 3.2 millimeters(0.125 inches). However if one door must always be closed first, means shall be provided to ensure that the doors close in the proper order.
Action required: 10 - Deficiency Rectified
Due 9 January 2024
Resolved 9 January 2024
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 24 April 2023
Resolved
Before getting underway on a voyage or as soon as practicable thereafter, the master of a vessel shall ensure that suitable public announcements are made informing all passengers of the following:(1) The location of emergency exits, survival craft embarkation areas, and ring life buoys;(2) The stowage location(s) of life jackets;(3) Either:(i) The proper method of donning and adjusting life jackets of the type(s) carried on the vessel including a demonstration of the proper donning of a lifejacket, or(ii) That passengers may contact a crew member for a demonstration as appropriate,(4) The location of the instruction placards for life jackets and other lifesaving devices;(5) That all passengers will be required to don life jackets when possible hazardous conditions exist, as directed by the master; and(6) If the vessel is operating with reduced manning or equipment requirements in § 176.114 of this chapter.
Vessel's passenger safety orientation script did not include all of the required information.
46 CFR 185.506(a), 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2023
Resolved 2 May 2023
Resolution: Resolved via pictures
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 24 April 2023
Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests: (1) Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10 (incorporated by reference, see § 175.600 of this chapter) as amended here: (ii) Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew.
No portable extinguishers are being subjected to monthly inspection.
46 CFR 176.810(b), 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2023
Resolved 2 May 2023
Resolution: Resolved via pictures
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 January 2021
Resolved
All cable and wire must be installed with metal supports spaced not more than 610 millimeters (24 inches) apart, and in such a manner as to avoid chafing and other damage. The use of plastic tie wraps must be limited to bundling or retention of multiple cable installations, and not used as a means of support. Install metal supports in engine room and engine room vestibule.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 February 2021
Resolved 30 March 2021
Resolution: Metal supports were installed and plastic tie wraps were removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 January 2021
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Replace missing bulb and cover on main distribution panel in engine room.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 February 2021
Resolved 30 March 2021
Resolution: Missing bulb on main distribution panel was replaced.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead strength
Issued 24 February 2020
Resolved
KY02: Replace the doubler on the port side, side shell IVO where vessel rubs on fender at the pier (submit plan proposal for new plate thickness, size and possible frame changes).
Action required: 705 - Other - as specified
Resolved 4 March 2020
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 19 February 2020
Resolved
Replace the missing steel clips for the windows that have aluminum frames.
46CFR72.05-30(a)
Action required: 705 - Other - as specified
Due 1 August 2020
Resolved 20 January 2022
Resolution: Vessel rep notified CG the clips are on backorder from the company, will have them installed by 8/1/20, special note added.
20Jan22 verified fire clips have been installed
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 19 February 2020
Resolved
Replace the missing insulation on the soft patches in the engine room overhead.
Action required: 705 - Other - as specified
Due 20 April 2020
Resolved 28 February 2020
Resolution: Completed the instalation, all sat.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 9 January 2018
Resolved
Provide Safety Radiotelephony Certificate. Restricted to less than 1000ft from shore.
Action required: 705 - Other - as specified
Resolved 16 January 2018
Resolution: Received documentation from vessel of unexpired FCC Radiotelephony Certificate.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 9 January 2018
Resolved
Provide 2018 Coast Pilot and Light List publications.
Action required: 705 - Other - as specified
Due 31 January 2018
Resolved 23 February 2018
Resolution: Confirmed 2018 publications aboard the vessel.
Fire Fighting › Ventilation Systems › Exhaust Ducts (Galley Ranges)
Issued 9 January 2018
Resolved
Clean grease from galley extraction hood.
Action required: 705 - Other - as specified
Due 16 January 2018
Resolved 3 April 2018
Resolution: Attested to properly cleaned galley hood.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 9 January 2018
Resolved
Trace and remove ground from 120V system.
Action required: 705 - Other - as specified
Due 16 January 2018
Resolved 23 February 2018
Resolution: Confirmed ground was cleared from 120V system.
Electrical › Electrical Distribution System (emergency) › Junction Box
Issued 9 January 2018
Resolved
Enclose wires for high water alarms in junction boxes in bow thruster and pumproom spaces.
Action required: 705 - Other - as specified
Due 31 January 2018
Resolved 19 March 2018
Resolution: Received documentation from [name withheld] attesting to enclosed wires in requested spaces.
Communications › Radio Communications › VHF Radiotelephone
Issued 31 January 2017
Resolved
1) Enter MMSI number into VHF/DSC capable marine radio.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 February 2017
Resolved 17 April 2017
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 5 January 2016
Resolved
AF01- Repair hole in bottom fire door leading to the galley.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 February 2016
Resolved 4 February 2016
Resolution: Attended vessel, fire door was replaced.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 5 January 2016
Resolved
AF02- Remove electrical outlet on distribution panel in refrigeration void.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 February 2016
Resolved 4 February 2016
Resolution: attended vessel the outlet was removed.
Fire Fighting › Grease Extraction Hood › General
Issued 5 January 2016
Resolved
AF03- Clean galley hood.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 February 2016
Resolved 12 January 2016
Resolution: Received an email with a receipt showing that the owner hired a third party to clean all the galley hoods on the vessel.