Records from 1984 to 1989. Most recent: inspection, 21 January 1989.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 24
21 January 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1207169
20 January 1989
Certificate of Compliance · Deficiency Check
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 889831
6 January 1989
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 327740
24 April 1988
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 514531
20 December 1987
Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1313012
4 December 1987
Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1000355
9 August 1987
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 317302
9 August 1987
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1337184
16 April 1987
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 482158
16 April 1987
Deficiency Check
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1001261
8 April 1987
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 485904
8 April 1987
MARPOL Annex II Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1329751
30 November 1986
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 313041
25 October 1986
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 312355
25 October 1986
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1318399
16 May 1986
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 308992
29 November 1985
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 484675
8 November 1985
Type not recorded
No type recorded · COTP NEW HAVEN · USCG Northeast District (CGD-NE) · Activity 535959
13 April 1985
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 454069
13 April 1985
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 526046
5 November 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 975460
13 October 1984
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 298417
7 October 1984
Type not recorded
No type recorded · COTP NEW HAVEN · USCG Northeast District (CGD-NE) · Activity 459674
7 October 1984
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 974395
Deck/Cargo
Issued 20 January 1989
Resolved
PRIOR TO LOADING ANY CARGO REQUIRING OVER FLOW CONTROL VALVES, IN TANKS 7C,5C,6ACS,3C AND 4ACS,THE SPEED OF ACUTATION OF THE VALVES IS TO BE CORRECTEDAND THE OPERATION IS TO BE TO THE SATISFACTION OF THE ATTENDING U. S. COASTGUARD MARINE INSPECTION.
Condition: Unknown
Due 21 January 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 20 January 1989
Resolved
PRIOR TO LOADING ANY CARGO IN CARGO TANK 2CP REPAIR TO THE SATISFACTION OF THE ATTENDING U. S. COAST GUARD MARINE INSPECTOR, THE BY HYDRAULIC LEAK TO THE HYDRAULIC DEEP WELL PUMP.
Condition: Unknown
Due 20 January 1989
Resolved 20 January 1989
Deck/Cargo
Issued 20 January 1989
Resolved
UPON COMPLETION OF REPAIRS TO THE PORT AND STARBOARD ANCHOR WINDLESS, HAVE CLASS SOCIETY PROVIDE TO [name withheld] A SURVEY REPORT ACCEPTING THE WINDLASS REPAIRS TO THEIR STANDARDS. THESE REQUIREMENT IS TO BE ACCOMPLISHPRIOR TO DEPARTURE FROM THE PORT OF HOUSTON.
Condition: Unknown
Due 20 January 1989
Resolved 20 January 1989
Deck/Cargo
Issued 20 January 1989
Resolved
PRIOR TO LOADING ANY CARGO IN TANKS 7C, 5C, 6ACS, 3C, 4ACS, AND IP, PROVE TO THE SATISFACTION OF THE ATTENDING U.S. COAST GUARD MARINE INSPECTOR THE PROPER OPERATION OF THE REMOTE VALVE INDICATORS FOR THESE TANKS.
Condition: Unknown
Due 21 January 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 6 January 1989
Resolved
INERT GAS SYSTEM MUST BE TESTED TO THE SATISFACTION OF THE COGNIZANT COTP/OCMI.
Condition: Unknown
Due 18 May 2002
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 8 April 1987
Resolved
PROVIDE ON BOARD AN APPROVED COPY OF THE P & A MANUAL
Condition: Unknown
Due 8 April 1987
Resolved 8 April 1987
Documentation
Issued 8 April 1987
Resolved
PROVIDE ON BOARD AN IMO CERTIFICATE OF FITNESS VERIFYING COMPLIANCE WITH MARPOL ANNEX II. A COPY MUST ALSO BE SUBMITTED TO COMDT (G-MTH-1) FOR APPROVAL.
Condition: Unknown
Due 8 April 1987
Resolved 8 April 1987
Documentation
Issued 8 April 1987
Resolved
PROVIDE ON BOARD A CARGO RECORD BOOK
Condition: Unknown
Due 8 April 1987
Resolved 8 April 1987
Documentation
Issued 8 April 1987
Resolved
AFTER APPROVAL OF THE IMO COF BY COMDT, PLACE ON BOARD THE NEW SUBCHAPTER OENDORSEMENT.
Condition: Unknown
Due 8 April 1987
Resolved 8 April 1987
Documentation
Issued 8 April 1987
Resolved
PLACE ON BOARD A COPY OF THE PRELIMINARY P & A MANUAL. DNV (HOUSTON) SURVEYOR INDICATED THAT A MANUAL HAS BEEN SUBMITTED TO DNV FOR APPROVAL.
Condition: Unknown
Due 8 April 1987
Resolved 8 April 1987
Deck/Cargo
Issued 25 October 1986
Resolved
WARNING SIGN REQUIRED AT GANGWAY WHILE MOORED NOT DISPLAYED.
Condition: Unknown
Due 25 October 1986
Resolved 25 October 1986
Deck/Cargo
Issued 25 October 1986
Resolved
VESSEL COULD NOT PRODUCE A RECORD OF A HYDROSTATIC PRESSURE TEST OF CARGO PIPING, RELIEF VALVES AND PRESSURE GAUGES CONDUCTED WITHING THE LAST YEAR.
Condition: Unknown
Due 25 October 1986
Resolved 25 October 1986
Navigation
Issued 25 October 1986
Resolved
VESSEL HAD ON BOARD A 1985 U.S. COAST PILOT NOT CORRECTED UP TO DATE.
Condition: Unknown
Due 25 October 1986
Resolved 25 October 1986
Navigation
Issued 25 October 1986
Resolved
CHARTS 12326, 12327 AND 12333 NOT CORRECTED UP TO DATE.
Condition: Unknown
Due 25 October 1986
Resolved 25 October 1986
Deck/Cargo
Issued 25 October 1986
Resolved
VESSELS INERT GAS SYSTEM WAS NOT OPERATED TO MAINTAIN AN INERT ATMOSPHERE IN ITS CARGO TANKS.
Condition: Unknown
Due 25 October 1986
Resolved 25 October 1986
Deck/Cargo
Issued 25 October 1986
Resolved
HYDRO TEST CARGO TRANSFER PIPING AND PORTABLE NON-METALLIC HOSES AT 1 1/2 MAWP
Condition: Unknown
Due 25 October 1986
Resolved 25 October 1986
Fire Fighting
Issued 25 October 1986
Resolved
FREE UP EXTERIOR FIRE STATIONS.
Condition: Unknown
Due 25 October 1986
Resolved 25 October 1986
Unknown
Issued 25 October 1986
Resolved
PROVE PROPER OPERATION OF DECONTAMINATION SHOWER LOCATED MIDSHIPS.
Condition: Unknown
Due 25 October 1986
Resolved 25 October 1986
Engineering
Issued 13 October 1984
Resolved
THE OILY-WATER SEPARATING EQUIPMENT REQUIRED BY 33 CFR 155.370 (A) WAS INOPERATIVE. ISSUED COTP ORDER 24-84 DENYING RE-ENTRY TO THE PORT OF BALTIMORE UNTIL REPAIRED.
Condition: Unknown
Due 13 October 1984
Resolved 13 October 1984