MAURY USCG vessel records Sign in
← All vessels

PANTHERA

PANTHERA is a 2001 freight ship. The Coast Guard has recorded 11 inspections since 2001, most recently in May 2012, along with 2 deficiencies.

Records from 2001 to 2012. Most recent: inspection, 21 May 2012.

Built
2001
Last inspected
21 May 2012
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9226700 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
ANTIGUA AND BARBUDA
—
Maury page id
psix-23717

Inspections, by type

…with no type recorded3
Years with a record 9 calendar years (2001–2012)
The 11 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it6274 - Convention (Subpart B), Gross Ton
3116 - Convention (Subpart B), Net Ton
7072 - Dead Weight, Ton
11063 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 11

21 May 2012 ISPS II Exam · Ballast Water Examination · PII Safety Exam · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4317475
14 September 2010 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3845902
28 October 2008 Ballast Water Examination · PII Safety Exam · ILO-147 Exam · ISPS II Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3353211
26 February 2007 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2877700
9 May 2006 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2644872
20 August 2005 PII Safety Exam · ISPS II Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2468818
19 August 2005 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2468256
16 January 2003 Annual Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1731330
10 April 2002 Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1601150
27 August 2001 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 293048
26 June 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 291401

Deficiency record · 2

Engineering › Sea-water System (primary cooling) › Piping
Issued 14 September 2010 Resolved
1410 - Propulsion main engine - The condition of the ship and its equipment shall be fit to proceed to sea w/o danger to the ship or crew. There is a soft patch on the jacket water cooler, raw water outlet pipe for the main engines after the connection to the cooler and prior to the elbow. - SOLAS 2004 cons. I/11.
Action required: 705 - Other - as specified
Due 28 September 2010
Resolved 31 May 2012
Resolution: Vessel replaced the raw water outlet pipe. PSC Team verified that the pipe was replaced and the vessel provided their ism report stating the repair was made. Vessel had received a class survey after the deficiency was issued and there were no condition.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device Recorder
Issued 20 August 2005 Resolved
Install a continuous recorder for the echo-depth sounder within 30 days
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 September 2005
Resolved 14 February 2006

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.