Records from 1984 to 2007. Most recent: operational control imposed, 27 April 2007.
Inspection history · 47
27 April 2007
PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2917277
19 March 2007
PII Safety Exam · ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2890522
24 July 2006
Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2722970
22 July 2006
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2758171
20 March 2006
Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2606785
19 January 2006
Administrative Inspection
Administrative · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2569843
14 July 2005
Random ISPS/MTSA/PSC
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2426144
12 May 2005
Ballast Water Examination · PII Safety Exam
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2355688
8 May 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2351983
29 October 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2231393
26 August 2004
PII Safety Exam
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2177526
25 August 2004
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2176757
28 June 2004
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2113396
25 June 2004
ISPS III Exam
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2110140
22 June 2004
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2106951
22 June 2004
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2107390
21 June 2004
PII Safety Exam
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2105777
17 February 2004
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2007438
12 October 2003
Type not recorded
No type recorded · GROUP SEATTLE · USCG Northwest District (CGD-NW) · Activity 1927129
1 July 2003
Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1832550
26 May 2003
Type not recorded
No type recorded · GROUP SEATTLE · USCG Northwest District (CGD-NW) · Activity 1801704
23 April 2003
Administrative Inspection
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1779400
13 April 2002
Ballast Water Examination · Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1604500
22 July 1997
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 405926
8 April 1997
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 402204
12 June 1996
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 392128
28 February 1996
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 388189
24 June 1995
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 379763
10 December 1994
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 481072
15 August 1994
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 369418
4 March 1994
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 447566
5 February 1993
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 490538
21 January 1993
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 440290
8 June 1992
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 351425
23 May 1991
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 343891
24 October 1990
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 455860
18 April 1990
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 336625
1 November 1989
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 539277
8 May 1989
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 330185
30 November 1988
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 453197
9 April 1988
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 322567
10 November 1987
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 471951
17 October 1986
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 539142
16 April 1986
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 308112
24 September 1985
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 526413
27 March 1985
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 301155
18 October 1984
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 298464
Engineering › Steam System (main) › Lagging/Insulation
Issued 27 April 2007
No resolution recorded
Steam leaks from piping on lower level MMR (Main Machinery Room). Steam insulation is wasted due to excessive water damage. SOLAS 74 Ch.1 Reg.11
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Engineering › Lubricating Oil Storage/Transfer System › Piping
Issued 27 April 2007
No resolution recorded
Oily rags and leaks present in lower level MMR (Main Machinery Room). Lube oil leak in vicinity of portable air handle pump, contents of which are dripping into a full bucket on the bilge floor.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Fire Fighting › Self-contained Breathing Apparatus › Air Supply (minutes)
Issued 19 March 2007
Resolved
Emergency escape breathing device in machinery space expired. Tank pressure low.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2007
Resolution: Received Class report clearing deficiency
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 19 March 2007
Resolved
Fire detector in engine room not capable of automatically indicating the presence/ indication of fire. Detector covered with plastic bag.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2007
Resolution: Received Class report clearing deficiency.
Fire Fighting › Fire Hydrants › Condition
Issued 19 March 2007
Resolved
Excessive salt water corrosion found on several fire plugs.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2007
Resolution: Received Class report clearing deficiency.
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 19 March 2007
Resolved
Emergency fire pump produced smoke during operation and is unable to supply satisfactory water pressure at fire stations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 19 March 2007
Resolution: The crew demonstrated the emergency fire pump was able to supply adequate pressure to the hoses.
Operations/Management › Vessel Safety Management › Master's Responsiblity/Authority
Issued 19 March 2007
Resolved
Vessel did not report non-conformities per SMS procedures.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2007
Resolution: Received Class report clearing deficiency.
Engineering › Lubricating Oil Service System › Piping
Issued 19 March 2007
Resolved
Excessive lube oil leaks found on main diesel engine, crew rigged deflectors and buckets to redirect and contain oil.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2007
Resolved 21 March 2007
Resolution: Received Class report clearing deficiency.
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 19 March 2007
Resolved
Non-compliance or substantial deterioration that prevented intended use of fire response system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2007
Resolved 21 March 2007
Resolution: Received Class report clearing deficiency.
Engineering › Steering Gear System › Linkage
Issued 19 March 2007
Resolved
Steering gear leaking hydraulic oil, 1.5 inches of oil present in primary containment.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2007
Resolution: Received Class report clearing deficiency.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 19 March 2007
Resolved
IMO number not painted in contrasting color.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 21 March 2007
Resolution: Received Class report clearing deficiency.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 20 March 2006
Resolved
Fire control plan does not indicate the galley as a class A division. Class to attend vessel and correct.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 20 March 2006
Resolved 24 July 2006
Resolution: Received class report attesting to repairs.
Engineering › Sea-water System (primary cooling) › Piping
Issued 20 March 2006
Resolved
Outlet piping on hot water cooling pump for main diesel engine is leaking. Class to attend and verify repairs.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 20 March 2006
Resolved 24 July 2006
Resolution: Received class report attesting to repairs.
Navigation
Issued 22 July 1997
Resolved
STEERING GEAR EXTENSION ARM NOT DOUBLE NUTTED.
Condition: Unknown
Due 27 July 1997
Resolved 27 July 1997