M. FARUK

M. FARUK is a 1984 freight ship. The Coast Guard has recorded 32 inspections since 1984, most recently in September 2010, along with 33 deficiencies and 9 operational controls, 1 with no removal date recorded.

Records from 1984 to 2010. Most recent: operational control imposed, 27 September 2010.

Built
1984
Last inspected
25 September 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

8028890 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
238194
Flag
GREECE
—
Maury page id
psix-238194

Inspections, by type

…with no type recorded22
Years with a record 20 calendar years (1984–2010)
The 32 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it20476 - Convention (Subpart B), Net Ton
36022 - Convention (Subpart B), Gross Ton
63494 - Dead Weight, Ton
74617 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 32

25 September 2010 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3858019
24 September 2010 Ballast Water Examination · ISPS III Exam · PI Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3854998
9 February 2010 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3677817
10 December 2009 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3648211
8 December 2009 MARPOL Annex VI Survey · PII Safety Exam · Ballast Water Examination · MARPOL Annex I Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3636675
28 April 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3194367
6 March 2008 Deficiency Check
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 3159424
18 January 2008 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3132569
11 August 2005 Random ISPS/MTSA/PSC
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2459292
22 November 2004 Ballast Water Examination · Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2245784
15 November 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2241760
10 September 2004 ISPS II Exam · PII Safety Exam
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2192618
16 October 2003 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1929955
15 October 2003 MARPOL Annex I Examination · Annual Inspection · Ballast Water Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1928398
18 October 2002 MARPOL Annex I Examination · Annual Inspection · Ballast Water Examination · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1690233
15 October 2002 Type not recorded
No type recorded · Sector Astoria · USCG Northwest District (CGD-NW) · Activity 1692075
29 November 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 295937
16 March 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 275894
2 December 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 714841
9 June 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 429758
30 July 1998 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 418717
17 September 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 395266
13 March 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 376811
18 December 1992 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 355381
5 July 1992 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 351834
11 June 1991 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 344270
15 November 1989 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 333632
10 June 1988 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 323723
6 January 1988 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 320533
14 June 1986 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 493128
16 December 1985 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 305942
2 November 1984 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 298587

Deficiency record · 33

Construction/Loadline › Hull › Hull Plating
Issued 25 September 2010 Resolved
Vessel grounded in Theodore Ship Channel. Remain in port until a survey of the ship's hull is completed to assess any potential damage caused by your vessel's grounding.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 September 2010
Resolution: Rescinded Op Contol. Recieved report of survey from DNV, no damage found. Cleared deficiency.
Engineering › Steering Gear System › Pump
Issued 8 December 2009 Resolved
0936- Steering Gear- Observed significant hydraulic leaks on both steering gear pumps. Hydraulic oil was covering the pump and pooling in the surrounding containment. Received class report from DNV stating that the crew replaced the seal and o-ring on the inboard steering pump. However, some leakage is still present from the servo motors and parts have been ordered. SOLAS II-1/29.
Action required: 705 - Other - as specified
Due 15 December 2009
Resolved 9 February 2010
Resolution: Received class report from DNV satisfying the requirement.
Fire Fighting › Remote Fuel Shutoff › General
Issued 8 December 2009 Resolved
0710- Fire Prevention- Observed remote fuel shut off valve to diesel oil service tank blocked in open position with wooden block held in place with wire. #2 general service generator on line at the time of exam. Bypassing safety feature; prevents the valve from being closed from outside the machinery space. SOLAS 74 II-2/33.
Action required: 705 - Other - as specified
Due 8 December 2009
Resolved 9 December 2009
Resolution: Received, reviewed and accepted class report from DNV stating that the crew removed the block and repaired the D/O Service Tank valve and that it was tested with satisfactory results.
Engineering › Fuel Oil Service System › Piping
Issued 8 December 2009 Resolved
0710- Fire Prevention- Observed numerous leaks on the diesel oil purifier. Found a fuel soaked rag on the inlet/outlet connection of the seal water piping; diesel oil was found pooling underneath the purifier and in the surrounding containment. The condition presents a significant fire hazard in the space. SOLAS 74 II-2/33.
Action required: 705 - Other - as specified
Due 8 December 2009
Resolved 9 December 2009
Resolution: Received, reviewed and accepted class report from DNV stating that the crew replaced the D/O Purifier inlet and outlet connection and cleaned the purifier compartment to the surveyor''s satisfaction.
Fire Fighting › Fire Main › Condition
Issued 18 January 2008 Resolved
#2 FIRE PUMP LEAKS EXCESSIVELY AT A MINIMUM OF HALF A GALLON PER MINUTE WHILE RUNNING. IDENTIFY SOURCE OF LEAK AND REPAIR.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 March 2008
Resolution: Received class report verifying satisfactory repairs, operation/testing.
Fire Fighting › Fire Main › Condition
Issued 18 January 2008 Resolved
DIME SIZE HOLE IN FIRE PUMP LINE BETWEEN MAIN FIRE PUMP #1 AND #2. LINE LEAKS AT A MINIMUM OF ONE GALLON PER MINUTE WHILE PUMPS ARE RUNNING. PRESSURE IS NOT AFFECTED AT THIS TIME. REPAIR OR CROP AND RENEW LINE.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 March 2008
Resolution: Receievd class report verifying satisfactory repairs, operation/testing.
Construction/Loadline › Structures › Door
Issued 18 January 2008 Resolved
ENGINE ROOM EMERGENCY ESCAPE DOORS ARE NOT SELF-CLOSING TYPE.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 March 2008
Resolution: Received class report verifying satisfactory repairs, operatin/testing.
Navigation › Piloting/Steering › Marine Charts
Issued 11 August 2005 Resolved
Vessel did not have updated charts on board.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 18 August 2005
Resolved 12 August 2005
Resolution: On 12Aug05 SECTOR LA/LB inspectors reviewed the vessel charts and were found satisfactory and cleared the deficiency.
Engineering › Steering Gear System › Pump
Issued 10 September 2004 Resolved
Replace gauge on the gear #1 and #2 gear pumps in the steering gear room within the next 30 days to satisfication of Coast Guard Inspector.
Action required: 705 - Other - as specified
Due 11 October 2004
Resolved 22 November 2004
Resolution: Guage replaced.
Engineering › Generator (propulsion/auxiliary-electric) › Fixture Circuitry
Issued 10 September 2004 Resolved
Replace valve cooling gauge on the #1 ships service generator within next 30 days to the satisfication of the Coast Guard Inspector.
Action required: 705 - Other - as specified
Due 11 October 2004
Resolved 22 November 2004
Resolution: Guage replaced.
Electrical › Lighting (service) › Lighting Fixture
Issued 10 September 2004 Resolved
Replace water light bracket for water light on port side near cargo hold #2, within the next 30 days to the satisfication of Coast Guard Inspector.
Action required: 705 - Other - as specified
Due 11 October 2004
Resolved 22 November 2004
Resolution: Bracket fixed.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 10 September 2004 Resolved
Replace reflective tape on ring buoy on port side near cargo hold #2, within the next 30 days to the satisfication of Coast Guard Inspector.
Action required: 705 - Other - as specified
Due 11 October 2004
Resolved 22 November 2004
Resolution: Reflective tape replaced.
Documentation › Certificates/Documents
Issued 18 October 2002 Resolved
Include the waste oil service tank and the waste oil settling tank in block 31 of the IOPP certificate MARPOL 73/78 LEGACY COMPONENT DESC: IOPP Certificate
Action required: 705 - Other - as specified
Resolved 19 October 2002
Resolution: DNV provided class report stating the waste oil settling and service tanks are part of the sludge system and therfore has a means for retention and disposal of oil residue (sludge).
Fire Fighting › Emergency Fire Pumps
Issued 18 October 2002 Resolved
Make the emergency fire pump operational. LOLAS 74 II-2/52 LEGACY COMPONENT DESC: Power Source
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 October 2002
Resolution: DNV class surveyor states the V-belt for the priming pump was replaced and the emergency fire pump was operating satisfactorily. Surveyor conducted test of pump with two fire hoses one forward one aft with a pump pressure of 4 bar.
Lifesaving › Launching Appliances
Issued 18 October 2002 Resolved
Repair as original the mechanically powered appliance fitted for the recovery of the lifeboat. SOLAS 74 II-2/14 LEGACY COMPONENT DESC: Winch
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 October 2002
Resolution: Class surveyor provided report stating the air moter was overhauled and operating correctly.
Fire Fighting › Firemans Outfit › Self-Contained Breathing Apparatus
Issued 18 October 2002 Resolved
Make operational the SCBA where the breathing air was escaping from the face piece at a rapid rate. SOLAS 74 II-2/14
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 October 2002
Resolution: Class Surveyor provided report stating the face piece demand valves were overhauled and are operating correctly.
Unknown
Issued 29 November 2001 Resolved
Repair all engine room fire main hydrants to original condition where hoseswill stay connected, prior to departure SOLAS 74 (unamended) II-2/ Reg 5(e)
Condition: Unknown
Due 1 December 2001
Resolved 1 December 2001
System not recorded
Issued 29 November 2001 Resolved
Repair as original, within 30 days, all hold trunk hatches on the main deck; presently deteriorated channels have thin scantlings and are not water or weathertight. ILLC 66 Annex I/15 Item should be addressed in upcoming shipyard period in PRC after leaving CONUS this voyage.
Condition: Unknown
Due 29 December 2001
Resolved 18 October 2002
Resolution: Received copy of DNV Class Survey report stating item successfully addressed during drydock in Shanghai 24 JAN 2001.
Construction/Loadline
Issued 29 November 2001 Resolved
Repair as original the treads on ladders from main deck to focsle deck and catwalks leading over port/stbd main deck pipe runs, running fwd and aft. Catwalk landings are deteriorated, to be completed within 30 days._x001C_ ILLC 66 Annex I/15
Condition: Unknown
Due 29 December 2001
Resolved 18 October 2002
Resolution: Received copy of DNV Class Survey report stating item successfully addressed during drydock in Shanghai 24 JAN 2001.
Construction/Loadline
Issued 29 November 2001 Resolved
Replace all dry gaskets on main deck watertight doors and replace or repairall weathertight doors on A,B,C & D decks including hospital space as original to required water and/or weathertight condition within 30 days. ILLC 66 ANNEX I/15
Condition: Unknown
Due 29 December 2001
Resolved 18 October 2002
Resolution: Received copy of DNV Class Survey report stating item successfully addressed during drydock in Shanghai 24 JAN 2001.
Unknown
Issued 29 November 2001 Resolved
Repair as original puncture damage to #7 hold tank top near the centerline aft hold. Repairs to be finished prior to departure and to the satisfactionof the class surveyor and attending marine inspector. Class to determine ifdamage due to wastage or casualty fm bucket crane operations.
Condition: Unknown
Due 1 December 2001
Resolved 1 December 2001
Navigation
Issued 29 November 2001 Resolved
Make repairs as nec. to restore full ARPA capabilities on the stbd 10cm radar, prior to departure from port.
Condition: Unknown
Due 30 November 2001
Resolved 1 December 2001
Navigation
Issued 9 June 1999 Resolved
DEVICE TO INDICATED SPEED AND DISTANCE INOPERATIVE._x001C_ _x001C_ 33 CFR 164.40_x001C_
Condition: Unknown
Due 14 June 1999
Resolved 16 June 1999
Navigation
Issued 9 June 1999 Resolved
ECHO DEPTH SOUNDER NOT OPERATING PROPERLY._x001C_ _x001C_ 33 CFR 164.35(H)_x001C_ _x001C_
Condition: Unknown
Due 14 June 1999
Resolved 16 June 1999
Navigation
Issued 9 June 1999 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 17 March 2000
Resolved 17 March 2000
Fire Fighting
Issued 13 March 1995 Resolved
EMERGENCY FIRE PUMP DO NOT WORK.
Condition: Unknown
Due 13 March 1995
Resolved 3 April 1995
Fire Fighting
Issued 13 March 1995 Resolved
LEAK IN FIREMAIN ON MAIN DECK # 4 CARGO HOLD PORTSIDE.
Condition: Unknown
Due 14 March 1995
Resolved 3 April 1995
Engineering
Issued 13 March 1995 Resolved
REPAIR EXHAUST PIPE ON EMERGENCY ENGINE.
Condition: Unknown
Due 13 March 1995
Resolved 3 April 1995
Navigation
Issued 6 January 1988 Resolved
CHART 18523 (09FEB85) NOT CORRECTED.
Condition: Unknown
Due 6 January 1988
Resolved 6 January 1988
Navigation
Issued 6 January 1988 Resolved
CHART 18524 (27APR85) NOT CORRECTED.
Condition: Unknown
Due 6 January 1988
Resolved 6 January 1988
Navigation
Issued 6 January 1988 Resolved
ARPA NOT LABELED.
Condition: Unknown
Due 6 January 1988
Resolved 6 January 1988
Navigation
Issued 6 January 1988 Resolved
CHART 18521 (26OCT85) NOT CORRECTED.
Condition: Unknown
Due 6 January 1988
Resolved 6 January 1988
Documentation
Issued 2 November 1984 Resolved
THE IOPP CERTIFICATE REQUIRED BY 33 CFR 151.19 WAS NOT AVAILABLE. VESSEL HAD A TEMPORARY IOPP CERTIFICATE ON BOARD WHICH EXPIRED 29 SEP 1984.
Condition: Unknown
Due 2 November 1984
Resolved 2 November 1984

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.