MAURY USCG vessel records
← All vessels

YM COSMOS

YM COSMOS is a 2000 freight ship. The Coast Guard has recorded 6 inspections since 2025, most recently in July 2026, along with 3 deficiencies.

Records from 2025 to 2026. Most recent: inspection, 6 July 2026.

Built
2000
Last inspected
6 July 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 6 July 2026
Operational controls None recorded without a removal date
Years with a record 2 calendar years (2025–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9198288
Flag
LIBERIA
Maury page id
psix-23833

Documentation record

Tonnage as PSIX records it64254 - Simplified, Gross Ton
64254 - Convention (Subpart B), Gross Ton
35137 - Simplified, Net Ton
35137 - Convention (Subpart B), Net Ton
91413 - Displacement, Metric Ton
68303 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

6 inspections, each with its date, unit and type; 3 deficiencies with the resolution recorded against each; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 6

6 July 2026 Administrative Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8430517
21 May 2026 PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8377308
23 January 2026 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8300800
25 November 2025 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8273935
14 October 2025 PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8247164
15 March 2025 PSC A
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8088733

Deficiency record · 3

14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 21 May 2026 Resolved
The system shall also be provided with arrangements to ensure that any discharge of oily mixtures is automatically stopped when the oil content of the effluent exceeds 15 parts per million. PSCO observed affluent valve on line from fresh water to oil content meter was blocked causing inaccurate reading of the 15 ppm alarm.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 21 June 2026
Resolved 6 July 2026
Resolution: DNV Class report submitted to our office attesting to the rectification of the noted deficiency.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 May 2026 Resolved
Electrical installations shall be such that: the safety of passengers, crew, and ship from electrical hazards shall be ensured. PSCO observed numerous lighting fixtures which had degraded silicone seals around the wire junctions in addition to several fixtures missing grounding wires as they were originally installed.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 21 June 2026
Resolved 6 July 2026
Resolution: DNV Class report submitted to our office attesting to the rectification of the noted deficiency.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 21 May 2026 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The crew could not display proper ventilation arrangements for the forward paint locker during the examination by PSCO. crew later stated that the ventilation fan was having problems and was waiting to be replaced, but this was not disclosed at the opening meeting when crew was asked directly if there were any issues or maintenance items on board.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 21 June 2026
Resolved 21 May 2026
Resolution: Crew replaced the inoperable ventilation fan.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.