This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
582 - Simplified, Gross Ton
582 - Simplified, Net Ton
Maury page id
psix-23840
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. Only barges and towing
vessels are in this archive, so any other vessel type in the same activity does not
appear here: these lists are a floor, not a complete manifest.
Repair cargo oil leak from the #3 starboard tank into the aft rake. Provide a gas free certificate for the aft rake and #3 starboard tanks as safe for entry so an inspection can be completed by an attending marine inspector. Vessel may not load cargo until the tanks are repaired.
Action required: 705 - Other - as specified
Due 6 September 2007
Resolved 7 August 2007
Resolution: See narrative.
Electrical › Electric Supply System (service) › Battery Charger
Issued 6 August 2007Resolved
Provide permanent wiring installation for 12 VDC battery charger in barge office.
Action required: 705 - Other - as specified
Due 5 September 2007
Resolved 7 August 2007
Resolution: See narrative.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 6 August 2007Resolved
Provide properly service B-II fire extinguisher for port side main deck. Current extinguisher is past the one year service date (Jan 2006).
Action required: 705 - Other - as specified
Due 5 September 2007
Resolved 6 August 2007
Resolution: Corrected on the spot by replacing with new extinguisher.
Stability › Watertight Integrity › General
Issued 6 August 2007Resolved
Make aft rake port side hatch watertight.
Action required: 705 - Other - as specified
Resolved 7 August 2007
Resolution: Corrected on the spot by adjusting the hatch.
Construction/Loadline › Structures
Issued 29 May 2003Resolved
A fillet weld was found to be cracked from the crown of the weld thru the fusion line. This weld provides structural support from a gusset to a structural angle supporting beam. Location of the defective weld is in the aft rake, port side, on the deck, near the base of the entry/exit ladder. LEGACY COMPONENT DESC: Rake
Due 29 June 2003
Resolved 27 February 2004
Resolution: Prior marine inspector verified repairs. Confirmed repairs were conducted.
Documentation
Issued 13 May 2001Resolved
Provide an approved response plan for this vessel.
Condition: Unknown
Due 13 June 2001
Resolved 13 June 2001