Records from 1984 to 2005. Most recent: inspection, 10 August 2005.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 32
10 August 2005
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2458627
27 February 2002
Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1489641
23 October 2001
Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1403482
29 May 2001
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1470341
23 May 2000
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1053971
1 February 2000
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1452658
21 May 1999
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1410154
28 May 1998
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1427554
2 March 1998
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1390715
14 May 1997
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1424402
18 April 1996
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1468807
15 March 1996
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1404124
8 June 1995
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 657061
18 May 1995
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1424113
23 May 1994
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1169869
19 April 1994
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 861604
10 June 1993
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 836484
13 April 1993
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1144624
6 May 1992
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1269700
25 February 1992
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1268359
6 June 1991
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 917078
21 March 1991
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1241413
1 November 1990
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 912433
1 September 1990
Drydock Extension
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 909914
7 February 1990
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1243073
21 February 1989
Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1198166
21 November 1988
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1206599
10 November 1987
COI Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1005260
10 December 1986
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1026441
1 April 1986
Credit Drydock
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1307806
18 November 1985
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 995197
16 November 1984
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 976601
Construction/Loadline › Hull
Issued 27 February 2002
Resolved
Inspection revealed 41 blisters ranging in size from 1 inch to 3 inches all around the hull above and below the waterline.
Action required: 705 - Other - as specified
Due 27 April 2002
Resolved 29 May 2002
Engineering › Sea-water System (primary cooling)
Issued 27 February 2002
Resolved
Sea valves, ball type in need of replacement, 3 each. LEGACY COMPONENT DESC: Valve
Action required: 705 - Other - as specified
Due 27 April 2002
Resolved 29 May 2002
Engineering › Fuel Oil Service System › Valve
Issued 29 May 2001
Resolved
REPAIR FUEL LEAK ON EMERGENCY SHUT OFF VALVES IAW 182.455 PRIOR TO CARRYINGPASSENGERS.
Condition: Unknown
Due 23 October 2001
Resolved 23 October 2001
Resolution: Fuel leak was repaired.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 29 May 2001
Resolved
PROVIDE 4 INCH MESH OR RAIL COURSES IAW 46 CFR 177.900 PRIOR TO 29JUN01.
Condition: Unknown
Due 23 October 2001
Resolved 23 October 2001
Resolution: Proper 4" mesh was installed.
Navigation › Piloting/Steering
Issued 29 May 2001
Resolved
PROVIDE NAVIGATION PUBS (COAST PILOT, CG LIGHT LIST, TADES AND CURRENT TABLES) IAW 46CFR184.420 PRIOR TO 29JUN01. LEGACY COMPONENT DESC: Navigation pubs
Condition: Unknown
Due 23 October 2001
Resolved 23 October 2001
Resolution: Proper navigation pubs were provided.
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 May 2001
Resolved
REMOVE WIRE NUTS ON ELECTRICAL WIRING THROUGHOUT VESSEL IAW 46CFR183.340 PRIOR TO 29JUN01.
Condition: Unknown
Due 23 October 2001
Resolved 23 October 2001
Resolution: Wire nuts were removed and proper repairs were made.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 29 May 2001
Resolved
PROVIDE FIXED AND PORTABLE FIRE EXTINGUISHER SERVICE CERTIFICATES IAW 46CFR176.810 PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 23 October 2001
Resolved 23 October 2001
Resolution: Service certificates were provided.
Construction/Loadline
Issued 1 February 2000
Resolved
46 CFR 177.300 - REPLACE STARBOARD SKEG BOLTS.
Condition: Unknown
Due 1 February 2000
Resolved 6 April 2000
Navigation
Issued 1 February 2000
Resolved
46 CFR 182.610 - REPLACE LOWER RUDDER PINTLE BOLTS WHERE IT'S CONNECTED TO THE KEEL.
Condition: Unknown
Due 1 February 2000
Resolved 6 April 2000
Construction/Loadline
Issued 1 February 2000
Resolved
46 CFR 177.300 - REPLACE ALL BAD/ROTTED WOOD IN THE PASSENGER DECK OVERHEAD.
Condition: Unknown
Due 1 February 2000
Resolved 6 April 2000
Construction/Loadline
Issued 1 February 2000
Resolved
46 CFR 177.900 - REINSTALL APPROVED RAILING IN PORT QUARTER AREA AND MAKE STURDY ALL REMAING DECK RAILING.
Condition: Unknown
Due 1 February 2000
Resolved 6 April 2000
Construction/Loadline
Issued 1 February 2000
Resolved
46 CFR 177.300 - REPLACE PORT RUDDER SKEG AND PROPERLY REMOUNT AND REPLACE THE STARBOARD SKEG BOLTS.
Condition: Unknown
Due 1 February 2000
Resolved 6 April 2000
Construction/Loadline
Issued 1 February 2000
Resolved
46 CFR 182.500 - PROPERLY MOUNT THE BILGE PUMP IN THE ENGINE ROOM.
Condition: Unknown
Due 1 February 2000
Resolved 6 April 2000
Navigation
Issued 1 February 2000
Resolved
46 CFR 182.610 - REPLACE CHECK BOLTS IN LOWER RUDDER PINTLE.
Condition: Unknown
Due 1 February 2000
Resolved 6 April 2000
Documentation
Issued 18 May 1995
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 8 June 1995
Resolved 8 June 1995
Fire Fighting
Issued 21 March 1991
Resolved
INSTALL APPROVED FIRE EXTINGUISHER BRACKETS TO ALL FIRE EXTINGUISHERS_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 March 1991
Resolved 21 March 1991
Lifesaving
Issued 21 March 1991
Resolved
ATTACH PADDLES TO LIFE FLOAT
Condition: Unknown
Due 21 March 1991
Resolved 21 March 1991
Electrical
Issued 21 March 1991
Resolved
INSTALL COVER TO BATTERY BOX INSTALLATION
Condition: Unknown
Due 21 March 1991
Resolved 21 March 1991
Engineering
Issued 21 March 1991
Resolved
PROPERLY GROUND FUEL TANK WITH AT LEAST #8 AWG WIRE
Condition: Unknown
Due 21 March 1991
Resolved 21 March 1991
Engineering
Issued 21 March 1991
Resolved
INSTALL PIPE PLUGS TO FUEL FILTERS AND REMOVE PET-COCK
Condition: Unknown
Due 21 March 1991
Resolved 21 March 1991
Lifesaving
Issued 21 March 1991
Resolved
INSTALL APPROVED WEAK LINK TO LIFE FLOAT PAINTER
Condition: Unknown
Due 21 March 1991
Resolved 21 March 1991
Engineering
Issued 21 March 1991
Resolved
STENCIL EMERGENCY FUEL SHUT OFF VALVE
Condition: Unknown
Due 21 March 1991
Resolved 21 March 1991
Navigation
Issued 21 March 1991
Resolved
REPAIR MAST HEAD LIGHT
Condition: Unknown
Due 21 March 1991
Resolved 21 March 1991
Lifesaving
Issued 10 December 1986
Resolved
PROVIDE NEW FLARES 6 RED/6 ORANGE.
Condition: Unknown
Due 10 December 1986
Resolved 10 December 1986
Documentation
Issued 10 December 1986
Resolved
PROVIDE AND PLACE ONBOARD VALID FCC SAFETY RADIOTELEPHONY CERTIFICATE.
Condition: Unknown
Due 10 December 1986
Resolved 10 December 1986
Lifesaving
Issued 10 December 1986
Resolved
PROVIDE ONE ADDITIONAL ADULT PFD.
Condition: Unknown
Due 10 December 1986
Resolved 10 December 1986
Documentation
Issued 10 December 1986
Resolved
RENEW VESSEL'S DOCUMENT.
Condition: Unknown
Due 10 December 1986
Resolved 10 December 1986
Construction/Loadline
Issued 10 December 1986
Resolved
REPLACE FLEXIBLE ELECTRIC BILGE PIPING WITH HARD WALLED PVC PIPING.
Condition: Unknown
Due 10 December 1986
Resolved 10 December 1986
Accommodation/Occupational Safety
Issued 10 December 1986
Resolved
PROVIDE FLAME SCREEN ON F.O.T. VENT.
Condition: Unknown
Due 10 December 1986
Resolved 10 December 1986
Accommodation/Occupational Safety
Issued 10 December 1986
Resolved
PROVIDE VENT WITH FLAME SCREEN ON MSD HOLDING TANK.
Condition: Unknown
Due 10 December 1986
Resolved 10 December 1986