FREELANCE is a 1985 passenger vessel (inspected). The Coast Guard has recorded 29 inspections since 2016, most recently in June 2026, along with 13 deficiencies, 1 operational control and 1 casualty investigation in 2023.
Records from 2016 to 2026. Most recent: inspection, 1 June 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
The counts in the strip above are the same counts; this table splits the inspections by
the kind of activity recorded. A blank resolution means none was recorded in this data; it
does not establish that a deficiency is outstanding. Years with a record are calendar
years in which a record exists, not years in service.
What Maury does not do.
Documentation record
Registered dimensions (L × B × D)71.1 ft × 22.1 ft × 6.2 ft
Registered tonnagegross 75 / net 51
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPEACOCK BOAT CO INC · WILMINGTON, CA, UNITED STATES · built 1985
DocumentationValid · issued 26 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it75 - Regulatory (Subpart C or D), Gross Ton 51 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299
What it gives that this page does not: the whole record in one
dated, citable document — every line with its Coast Guard activity id, the retrieval
date on the cover, built to print to PDF with its page breaks — that a surveyor can
attach and a lender can file. The same facts as this page, complete and in one file.
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
A request, not a checkout: leave an email and Maury replies once, with
the dated document for this hull and a Stripe invoice for $299. Nothing is charged before
the document is in your hands.
Used only to answer this request.
Not shared, not sold, and not added to a mailing list.
Inspection history · 29
1 June 2026Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8328265
7 August 2025Deficiency Check · Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8204555
20 March 2025Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8072420
7 January 2025Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8040501
7 December 2024In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8040500
13 May 2024Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7875668
23 September 2023In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7789850
6 April 2023Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7747054
15 March 2023COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7617113
18 January 2023Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7623235
6 January 2023Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7588961
19 December 2022Plan Review "T" Boat
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7622072
22 September 2022In-Service Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7553763
7 March 2022Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7401391
19 January 2022Damage Survey · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7384954
4 November 2021In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7346781
20 September 2021Type not recorded
No type recorded · Station Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7317731
6 May 2021Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7195488
25 January 2021Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7130294
26 February 2020Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6903487
7 March 2019Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6618141
15 January 2019Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6588603
1 February 2018COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6341832
19 January 2018Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6340786
28 November 2017Administrative Inspection
Administrative · Navigation Center · Activity 6313805
21 March 2017Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6096623
10 February 2017Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6057803
18 January 2017Plan Review "T" Boat
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6088812
18 February 2016Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5797591
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 20 March 2025Resolved
Each life float must be attached by a painter long enough that each float can float without contacting any other float in the group. Painters were deteriorated and approximately 15' length, which would not allow ready launching of floats without pulling on the next float before setting in the water.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2025
Resolved 8 April 2025
Resolution: Operator provided photo of properly rigged life floats.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 March 2025Resolved
Each ring life buoy on a vessel must be approved in accordance with 46 CFR 160.050 in Subchapter Q. Port life ring retro-reflective tape is deteriorating.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2025
Resolved 8 April 2025
Resolution: Operator provided attestation to updating the ring buoy retro reflective materials.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 29 September 2022Resolved
Bilges shall be free of oil and debris at all times. Remove all debris from bilges in all watertight compartments. Remove all oil soaked sorbent pads and remove any remaining oil/fuel from engine room bilge.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 October 2022
Resolved 10 October 2022
Resolution: Bilges cleaned
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 29 September 2022Resolved
Life floats serving as "primary lifesaving" shall be stowed so that when the vessel sinks the survival craft can easily be launched by crew or float free. 04 life floats stowed on top of operating station found with lines/nets/trash/poles/gaff hooks. Remove all items so that life floats can float free or be launched by crew. Vessel restricted to carrying 72 pax on Limited Coastwise route.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 October 2022
Resolved 30 September 2022
Resolution: All gear and debris removed, no longer restricting LF's
Each vessel must meet the applicable requirements in subchapter S.
Each hatch exposed to the weather must be watertight.
MI found hatch to steering space missing its sealing gasket making it no longer watertight.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2021
Resolved 24 May 2021
Resolution: Installed serviceable gasket making the hatch watertight.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 February 2020Resolved
The bilge pipe piercing the collision bulkhead in lieu of a screw down valve with reach rod may have a screwdown valve on the aft side of the bulkhead. Vessel had an inop ball valve installed. Replace w/ operable appropriate valve.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 February 2020
Resolved 26 February 2020
Resolution: Screwdown type valve installed satisfactorily.
Each vessel must meet the applicable requirements of subchapter S of this chapter, where each collision bulkhead may have penetrations that are as high & as far in as practicable & have means to make watertight. Outboard hyraulic line penetrating collision bulkhead had free communication all around hose. Make penetration watertight.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 February 2020
Resolved 26 February 2020
Resolution: Caulking applied and found to be watertight when applying forces on hydraulic line in all direcitons.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 February 2020Resolved
All cable and wire must be installed with metal supports spaced not more than 24" apart and in such a manner to avoid chaffing. Wiring in galley bilge space had fallen & was chaffing agains sonar post. Reinstall correctly.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2020
Resolved 26 February 2020
Resolution: Wire rehung correctly w/ no further threat of chaffing - wire condition found to be in good condition.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 February 2020Resolved
Where flexible nonmetallic hose is permitted for use in piping systems by this section, the hose must be SAE J1942 and in fuel oil systems may, if not more than 5 SIG, be installed with two clamps and do not reply on the spring tension of clamp for compressive force. Prove installed f/o lines on Kubota generator fuel pump run @ <5PSI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2020
Resolved 12 March 2020
Resolution: Provided generator part number for pump operating at less than 5 PSI, and installed dual hose clamps.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 21 March 2017Resolved
Breaker was open in the machinery space
Action required: 705 - Other - as specified
Due 21 March 2017
Resolved 21 March 2017
Resolution: Vessel covered empty breaker.
Engineering › Fuel Oil Service System › Valve
Issued 10 February 2017Resolved
Demonstrate operation of the remote fuel supply valve.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 March 2017
Resolved 10 February 2017
Resolution: Corrected during inspection.
Engineering › Steering Gear System › Linkage
Issued 10 February 2017Resolved
Provide retaining pin in steering ram connection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 March 2017
Resolved 10 February 2017
Resolution: Corrected during inspection.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 18 February 2016Resolved
Provide (8) batteries for life floats and life ring.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2016
Resolved 26 February 2016
Resolution: Replaced batteries of life floats and life rings.
6 April 2023Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7747054
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.