FREELANCE is a 1985 passenger vessel (inspected). The Coast Guard has recorded 81 inspections since 1985, most recently in June 2026, along with 67 deficiencies, 2 operational controls and 1 casualty investigation in 2023.

Records from 1985 to 2026. Most recent: inspection, 1 June 2026.

Built
1985
Last inspected
1 June 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDQ2779
238684
Flag
UNITED STATES
366977380
Maury page id
psix-238684

Inspections, by type

…with no type recorded4
Years with a record 40 calendar years (1985–2026)
The 81 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)71.1 ft × 22.1 ft × 6.2 ft
Registered tonnagegross 75 / net 51
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPEACOCK BOAT CO INC · WILMINGTON, CA, UNITED STATES · built 1985
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEWPORT BEACH, CA
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 26 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it75 - Regulatory (Subpart C or D), Gross Ton
51 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDQ2779MMSI 366977380 · active · compulsorily equipped · granted 27 March 2025, expires 27 March 2035
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 81

1 June 2026 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8328265
7 August 2025 Deficiency Check · Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8204555
20 March 2025 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8072420
7 January 2025 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8040501
7 December 2024 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8040500
13 May 2024 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7875668
23 September 2023 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7789850
6 April 2023 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7747054
15 March 2023 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7617113
18 January 2023 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7623235
6 January 2023 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7588961
19 December 2022 Plan Review "T" Boat
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7622072
22 September 2022 In-Service Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7553763
7 March 2022 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7401391
19 January 2022 Damage Survey · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7384954
4 November 2021 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7346781
20 September 2021 Type not recorded
No type recorded · Station Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7317731
6 May 2021 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7195488
25 January 2021 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7130294
26 February 2020 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6903487
7 March 2019 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6618141
15 January 2019 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6588603
1 February 2018 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6341832
19 January 2018 Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6340786
28 November 2017 Administrative Inspection
Administrative · Navigation Center · Activity 6313805
21 March 2017 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6096623
10 February 2017 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6057803
18 January 2017 Plan Review "T" Boat
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6088812
18 February 2016 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5797591
6 March 2014 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4784821
22 February 2012 Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4230760
27 January 2011 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3934595
2 December 2010 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3897659
22 February 2010 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3675443
13 January 2010 In-Service Inspection · Plan Review "T" Boat
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3689946
12 March 2009 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3427064
26 December 2008 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3365407
24 January 2008 Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3128361
8 January 2007 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2852139
27 January 2006 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2574946
13 January 2005 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2270569
3 December 2004 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2248351
17 November 2004 Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2243048
5 February 2004 Administrative Inspection · Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2001388
27 January 2004 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1991411
21 December 2003 In-Service Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1968023
3 February 2003 Hull Examination · Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1736547
28 January 2003 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1736014
28 May 2002 In-Service Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1616112
12 February 2002 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1485728
5 February 2001 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1361997
1 February 2000 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1451505
4 February 1999 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1365053
2 December 1998 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1406396
3 February 1998 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1426024
5 February 1997 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1398604
11 December 1996 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1406011
13 September 1996 Drydock Extension
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 954856
8 February 1996 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1464619
16 February 1995 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1442216
24 October 1994 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1171734
18 February 1994 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 854145
18 February 1993 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1144639
30 November 1992 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1142474
5 March 1992 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1315004
7 March 1991 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 921483
7 March 1991 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 997608
10 December 1990 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1232218
12 March 1990 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1225017
7 December 1989 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1226466
17 April 1989 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1034813
15 March 1989 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1033852
6 December 1988 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 896890
21 March 1988 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1030647
9 December 1987 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1310684
24 March 1987 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1017931
2 December 1986 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1328209
8 April 1986 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1296584
5 December 1985 Excursion Permit
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 989281
23 April 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 983236
12 April 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 975122

Deficiency record · 67

11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 20 March 2025 Resolved
Each life float must be attached by a painter long enough that each float can float without contacting any other float in the group. Painters were deteriorated and approximately 15' length, which would not allow ready launching of floats without pulling on the next float before setting in the water.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2025
Resolved 8 April 2025
Resolution: Operator provided photo of properly rigged life floats.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 March 2025 Resolved
Each ring life buoy on a vessel must be approved in accordance with 46 CFR 160.050 in Subchapter Q. Port life ring retro-reflective tape is deteriorating.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2025
Resolved 8 April 2025
Resolution: Operator provided attestation to updating the ring buoy retro reflective materials.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 29 September 2022 Resolved
Bilges shall be free of oil and debris at all times. Remove all debris from bilges in all watertight compartments. Remove all oil soaked sorbent pads and remove any remaining oil/fuel from engine room bilge.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 October 2022
Resolved 10 October 2022
Resolution: Bilges cleaned
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 29 September 2022 Resolved
Life floats serving as "primary lifesaving" shall be stowed so that when the vessel sinks the survival craft can easily be launched by crew or float free. 04 life floats stowed on top of operating station found with lines/nets/trash/poles/gaff hooks. Remove all items so that life floats can float free or be launched by crew. Vessel restricted to carrying 72 pax on Limited Coastwise route.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 October 2022
Resolved 30 September 2022
Resolution: All gear and debris removed, no longer restricting LF's
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 6 May 2021 Resolved
Each vessel must meet the applicable requirements in subchapter S. Each hatch exposed to the weather must be watertight. MI found hatch to steering space missing its sealing gasket making it no longer watertight.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2021
Resolved 24 May 2021
Resolution: Installed serviceable gasket making the hatch watertight.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 February 2020 Resolved
The bilge pipe piercing the collision bulkhead in lieu of a screw down valve with reach rod may have a screwdown valve on the aft side of the bulkhead. Vessel had an inop ball valve installed. Replace w/ operable appropriate valve.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 February 2020
Resolved 26 February 2020
Resolution: Screwdown type valve installed satisfactorily.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 26 February 2020 Resolved
Each vessel must meet the applicable requirements of subchapter S of this chapter, where each collision bulkhead may have penetrations that are as high & as far in as practicable & have means to make watertight. Outboard hyraulic line penetrating collision bulkhead had free communication all around hose. Make penetration watertight.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 February 2020
Resolved 26 February 2020
Resolution: Caulking applied and found to be watertight when applying forces on hydraulic line in all direcitons.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 February 2020 Resolved
All cable and wire must be installed with metal supports spaced not more than 24" apart and in such a manner to avoid chaffing. Wiring in galley bilge space had fallen & was chaffing agains sonar post. Reinstall correctly.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2020
Resolved 26 February 2020
Resolution: Wire rehung correctly w/ no further threat of chaffing - wire condition found to be in good condition.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 February 2020 Resolved
Where flexible nonmetallic hose is permitted for use in piping systems by this section, the hose must be SAE J1942 and in fuel oil systems may, if not more than 5 SIG, be installed with two clamps and do not reply on the spring tension of clamp for compressive force. Prove installed f/o lines on Kubota generator fuel pump run @ <5PSI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2020
Resolved 12 March 2020
Resolution: Provided generator part number for pump operating at less than 5 PSI, and installed dual hose clamps.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 21 March 2017 Resolved
Breaker was open in the machinery space
Action required: 705 - Other - as specified
Due 21 March 2017
Resolved 21 March 2017
Resolution: Vessel covered empty breaker.
Engineering › Fuel Oil Service System › Valve
Issued 10 February 2017 Resolved
Demonstrate operation of the remote fuel supply valve.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 March 2017
Resolved 10 February 2017
Resolution: Corrected during inspection.
Engineering › Steering Gear System › Linkage
Issued 10 February 2017 Resolved
Provide retaining pin in steering ram connection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 March 2017
Resolved 10 February 2017
Resolution: Corrected during inspection.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 18 February 2016 Resolved
Provide (8) batteries for life floats and life ring.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2016
Resolved 26 February 2016
Resolution: Replaced batteries of life floats and life rings.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 6 March 2014 Resolved
Test/log test of EPIRB monthly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 March 2014
Resolved 6 March 2014
Resolution: Crew conducted test of EPIRB in the presence of MI, logged test.
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 March 2014 Resolved
Install metal supports spaced not more than 24 inches apart on cable/wiring systems in engine room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 March 2014
Resolved 6 March 2014
Resolution: Crew secured cables/wires to installed supports utilizing metal hose clamps at intervals of not more than 24 inches.
Documentation › Logs/Records › Drug Test Records
Issued 22 February 2012 Resolved
Add Chad Bradley to random drug testing crew list from ASTS.
Action required: 705 - Other - as specified
Due 22 March 2012
Resolved 21 March 2012
Resolution: Received updated crew list from ASTS.
Operations/Management › Drills/Instruction › Not Conducted
Issued 22 February 2012 Resolved
Conduct and log drills (fire, MOB) at least every 3 months.
Action required: 705 - Other - as specified
Due 22 March 2012
Resolved 22 February 2012
Resolution: Corrected same day after MI witnessed satisfactory fire drill and MOB drill and vessel logged drills into logbook.
Communications › Alarms/Indicators › High Water Alarm
Issued 22 February 2012 Resolved
High water bilge alarms for galley (audible and visual) and forepeak (visual) were inoperative.
Action required: 705 - Other - as specified
Due 22 February 2012
Resolved 22 February 2012
Resolution: Repairs were made on the spot by the crew.
Engineering › Bilge Water Management System › Interface Detector
Issued 12 March 2009 Resolved
Demonstrate proper operation of all bilge high level alarms.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 April 2009
Resolved 13 March 2009
Engineering › Bilge Water Management System › Piping
Issued 12 March 2009 Resolved
Crop and renew wasted bilge piping in galley bilge void and conduct satisfactory pressure test of all bilge piping in the same.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 April 2009
Resolved 13 March 2009
Operations/Management › Drills/Instruction › Not Conducted
Issued 12 March 2009 Resolved
Conduct satisfactory fire and abandon ship drill.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 April 2009
Resolved 13 March 2009
Documentation › Certificates/Documents › FCC SSL
Issued 12 March 2009 Resolved
Provide valid FCC Safety Radiotelephony Certificate prior to operating 1000 feet from shore.
Action required: 705 - Other - as specified
Due 12 April 2009
Resolved 13 March 2009
Resolution: Provided FCC Safety Radiotelephony Certificate.
Documentation › Certificates/Documents › FCC SSL
Issued 12 March 2009 Resolved
Provide valic FCC Marine Radio Operator Permit for Captain of vessel prior to operating beyond 1000 feet from shore.
Action required: 705 - Other - as specified
Due 12 April 2009
Resolved 12 March 2009
Resolution: Provided FCC Marine Operators Permit for Captain.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 12 March 2009 Resolved
Properly label distribution panel in sewage tank void.
Action required: 705 - Other - as specified
Due 12 April 2009
Resolved 13 March 2009
Resolution: Distribution panel labeled.
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 March 2009 Resolved
Provide metal supports every 24 inches in galley bilge void, engine room, and lazarette for all wiring IAW 46 CFR 183.340.
Action required: 705 - Other - as specified
Due 12 April 2009
Resolved 13 March 2009
Resolution: Provided metal supports for vessel wiring.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 24 January 2008 Resolved
Provide alcohol testing kit on board IAW 46CFR4.06.
Action required: 705 - Other - as specified
Due 24 January 2008
Resolved 24 January 2008
Resolution: Provided.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 24 January 2008 Resolved
Provide proof of supervisors 1 hour EAP training IAW 46CFR16.401.
Action required: 705 - Other - as specified
Due 24 January 2008
Resolved 24 January 2008
Resolution: Provided.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 24 January 2008 Resolved
Repair/replace self igniting light to lifefloat directly aft of pilot house.
Action required: 705 - Other - as specified
Due 24 January 2008
Resolved 24 January 2008
Resolution: Replaced in kind.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (electric)
Issued 24 January 2008 Resolved
Replace/renew electric starter for port main engine.
Action required: 705 - Other - as specified
Due 24 January 2008
Resolved 24 January 2008
Resolution: Repaired.
Personnel › Certificates/Documents/Licenses › Certificate, CPR Course Completion
Issued 24 January 2008 Resolved
Provide CPR certification for at least 50% of crew.
Action required: 705 - Other - as specified
Due 24 February 2008
Resolved 24 January 2008
Resolution: Provided.
Electrical › Electrical Distribution System (service) › Cable
Issued 24 January 2008 Resolved
Remove dead end cable run from main service switchboard in sewage holding tank compartment.
Action required: 705 - Other - as specified
Due 24 February 2008
Resolved 24 January 2008
Resolution: Removed.
Electrical › Electric Supply System (service) › Battery Installation
Issued 24 January 2008 Resolved
Clean battery terminals for bank in sewage holding compartment.
Action required: 705 - Other - as specified
Due 24 February 2008
Resolved 24 January 2008
Resolution: Cleaned.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 24 January 2008 Resolved
Provide proper insulation for exhaust manifolds on main engines.
Action required: 705 - Other - as specified
Due 24 February 2008
Resolved 24 January 2008
Resolution: Provided.
Lifesaving › Lifefloat › Float-free Link
Issued 8 January 2007 Resolved
The float free link identification tag was missing.
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 January 2007
Resolved 8 January 2007
Resolution: Provided proof item was ordered to arrive1/9/07
Electrical › Electrical Distribution System (service) › Panelboard
Issued 8 January 2007 Resolved
Exposed wire and electrical tape used to splice wires in panelboard.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 January 2007
Resolved 8 January 2007
Resolution: All affected wires were spliced with end caps and crimped.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 7 January 2005 Resolved
Replace expired battery on EPIRB (406 mhz). Route restricted to 3 nautical miles until receive proof of valid battery.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 February 2005
Resolved 27 January 2005
Resolution: Replaced expired battery on EPIRB.
Fire Fighting › Semiportable CO2 Fire Extinguishers › Securing Means
Issued 7 January 2005 Resolved
Replace mounting bracket for fire extinguisher in galley.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 February 2005
Resolved 27 January 2005
Resolution: Replaced mounting bracket for fire extinguisher in galley.
Construction/Loadline › Hull › Stiffener
Issued 3 December 2004 Resolved
Crop and renew wasted deck stiffners in way of sewage holding tank
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 13 December 2004
Resolution: Replaced.
Construction/Loadline › Hull › Transverse Frame
Issued 3 December 2004 Resolved
Crop and renew P/S transverse frames #4, #5.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 13 December 2004
Resolution: Renewed.
Deck/Cargo › Holds/Tanks › Independent Tank
Issued 3 December 2004 Resolved
Renew wasted sewage holding tank.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 13 December 2004
Resolution: Renewed.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 3 December 2004 Resolved
Repair exhaust leaks on P/S MDE's.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 13 December 2004
Resolution: Repaired.
Electrical › Electric Supply System (service) › Cable
Issued 3 December 2004 Resolved
Remove all dead end cables in engineroom.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 December 2004
Resolved 13 December 2004
Resolution: Removed.
Engineering › Fuel Oil Service System › Valve
Issued 3 December 2004 Resolved
Repair wasted P/S remote fuel shut of valves.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 December 2004
Resolved 13 December 2004
Resolution: Repaired.
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 5 February 2004 Resolved
Provide 1 MF Radio or equivalent to comply with FCC regs along with valid updated Cert. LEGACY COMPONENT DESC: Radiotelephone Transceiver (2-27.5 MHz)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2004
Resolved 18 November 2004
Resolution: MF radio installed, FCC safety radiotelephone certificate updated.
Electrical › Lighting (service)
Issued 27 January 2004 Resolved
Repair stern light. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 January 2004
Resolved 10 February 2004
Resolution: Repaired
Engineering › Diesel Engine (propulsion-direct drive)
Issued 27 January 2004 Resolved
Make permanent repairs to port main engine wet exhaust elbow. LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2004
Resolved 10 February 2004
Resolution: Replaced.
Documentation › Certificates/Documents
Issued 21 December 2003 Resolved
Post all pages of COI. Vessel only the first page posted over the second page of COI. LEGACY COMPONENT DESC: Certificate of Inspection
Action required: 705 - Other - as specified
Due 5 January 2004
Resolved 9 January 2004
Lifesaving › Hand Flares
Issued 21 December 2003 Resolved
Store distress signals in properly marked, brightly colored, and easily accessible container. Vessel had their flares stored in a metallic cylindrical canister screwed at the top. Owner representative could not open the metallic canister during the inspection without proper tools. LEGACY COMPONENT DESC: Storage
Action required: 705 - Other - as specified
Due 5 January 2004
Resolved 9 January 2004
Engineering › Bilge Water Management System
Issued 21 December 2003 Resolved
Remove excessive bige water in engine room space. Bilge alarm did work.
Action required: 705 - Other - as specified
Due 5 January 2004
Resolved 9 January 2004
Lifesaving › Lifebuoys
Issued 21 December 2003 Resolved
Label vessel's name on port and center ring buoys. LEGACY COMPONENT DESC: Markings (ship name/port)
Action required: 705 - Other - as specified
Due 5 January 2004
Resolved 21 December 2003
Stability › Watertight Integrity
Issued 3 February 2003 Resolved
The anchor windlass hydraulic lines as they pass through the collision bulkhead are not watertight. LEGACY COMPONENT DESC: Collision Bulkhead
Action required: 705 - Other - as specified
Due 3 March 2003
Resolved 25 February 2003
Construction/Loadline › Structures
Issued 3 February 2003 Resolved
In the second compartment aft, the #1, 2, and 3 STBD and #3 PORT longitudal deck stringers are wasted. Crop and renew to good metal. LEGACY COMPONENT DESC: Longitudal Deck Stringer
Action required: 705 - Other - as specified
Due 3 March 2003
Resolved 25 February 2003
Electrical › Electrical Distribution System (service)
Issued 3 February 2003 Resolved
In the second compartment aft, either hard wire or provide a watertight cover for the electrical outlet providing power to the lighting. Plastic outlet was covered with salt deposit, indicating that outlet may be exposed to moisture. LEGACY COMPONENT DESC: Outlet Box
Action required: 705 - Other - as specified
Due 3 March 2003
Resolved 25 February 2003
Resolution: Installed a plastic waterproof cover.
Electrical › Electrical Distribution System (service)
Issued 3 February 2003 Resolved
In the engine room, provide metal wire hangers every 24 inches in place of plastic wire ties. LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 3 March 2003
Resolved 25 February 2003
Engineering › Diesel Engine (propulsion-direct drive)
Issued 3 February 2003 Resolved
In the engine room, replace holed piping on the STBD engine heat exchanger, per 46 CFR 182.720. LEGACY COMPONENT DESC: Heat Exchanger Piping
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 February 2003
Construction/Loadline › Hull
Issued 3 February 2003 Resolved
In the lazarette, #2 PORT and STBD longitudal stringers as they pass by the struts are cracked. They shall be permanently repaired by cropping and renewing. Temperory repairs may be made by welding cracks, prior to carrying passengers. LEGACY COMPONENT DESC: Stringer
Action required: 705 - Other - as specified
Due 3 March 2003
Resolved 25 February 2003
Resolution: Permanent repairs made.
Construction/Loadline
Issued 13 September 1996 Resolved
CONDUCT CREDIT DRYDOCK EXAMINATION PRIOR TO 31 DECEMBER 1996.
Condition: Unknown
Due 13 September 1996
Resolved 13 September 1996
Engineering
Issued 18 February 1993 Resolved
REPLACE RELIEF VALVE NOW INSTALLED ON WATER HEATER WITH ONE DESIGNED TO RELIEVE AT NO MORE THAN 210 DEGREES F. AND 100 PSI. THIS DEFICIENCY MAY BE CLEARED THROUGH THE MAIL IF A PURCHASE RECEIPT OR PHOTOGRAPH CLEARLY SHOWING SATISFACTORY RELIEF TEMPERATURE AND PRESSURE SETTINGS IS PROVIDED.
Condition: Unknown
Due 18 February 1993
Resolved 18 February 1993
Documentation
Issued 30 November 1992 Resolved
INSTALL DRAFT MARKS OR LOADING MARKS AS DESCRIBED IN 46 CFR 185.30-3 PRIOR TO COMPLETION OF THE FIRST ROUTINE DRYDOCKING AFTER 01 JANUARY 1993.
Condition: Unknown
Due 30 November 1992
Resolved 30 November 1992
Documentation
Issued 30 November 1992 Resolved
CONDUCT A DEADWEIGHT SURVEY WITNESSED BY THE USCG TO VERIFY LIGHTWEIGHT WITHIN ONE YEAR OF COMPLETION OF THE FIRST ROUTINE DRYDOCKING AFTER_x001C_ 01 JANUARY 1993.
Condition: Unknown
Due 30 November 1992
Resolved 30 November 1992
Navigation
Issued 5 March 1992 Resolved
PROVIDE DEVIATION TABLE FOR MAGNETIC COMPASS
Condition: Unknown
Due 6 March 1992
Resolved 16 March 1992
Lifesaving
Issued 12 March 1990 Resolved
RENEW RETROREFLECTIVE TAPE ON PORT LIFEFLOAT (ABOVE BRIDGE) AND PORT RING BUOY.
Condition: Unknown
Due 12 March 1990
Resolved 12 March 1990
Electrical
Issued 12 March 1990 Resolved
PROPERLY ATTACH JUNCTION BOX ON FORWARD BULKHEAD OF LAZARETTE.
Condition: Unknown
Due 12 March 1990
Resolved 12 March 1990
Electrical
Issued 12 March 1990 Resolved
REPLACE "SO" ELECTRICAL CABLE TO BLOWER IN LAZARETTE WITH PROPER CABLE.
Condition: Unknown
Due 12 March 1990
Resolved 12 March 1990
Construction/Loadline
Issued 7 December 1989 Resolved
REPLACE PVC VALVE TO LONGITUDINAL BAIT WATER SUPPLY AT FORWARD ENGINE ROOM BULKHEAD WITH A METALLIC VALVE OPERABLE FROM ABOVE DECK (46 CFR 182.40-1).
Condition: Unknown
Due 7 December 1989
Resolved 7 December 1989
Engineering
Issued 7 December 1989 Resolved
REPLACE PVC PIPING TO PORT AND STARBOARD MAIN ENGINES AND GENERATOR COOLINGSUPPLY SYSTEMS WITH METALLIC PIPING (46 CFR 182.40-5).
Condition: Unknown
Due 7 December 1989
Resolved 7 December 1989
Construction/Loadline
Issued 12 April 1985 Resolved
SUBMIT PLANS, OBTAIN APPROVAL, AND IMPLEMENT MODIFICATIONS NESESSARY TO MEET DAMAGED STABILITY CRITERIA.
Condition: Unknown
Due 12 April 1985
Resolved 12 April 1985

Casualty record · 1

6 April 2023Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7747054
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.