MAURY USCG vessel records Sign in
← All vessels

ADARO

ADARO is a 1983 tank ship. The Coast Guard has recorded 45 inspections since 1984, most recently in October 2005, along with 18 deficiencies and 1 operational control.

Records from 1984 to 2005. Most recent: inspection, 25 October 2005.

Built
1983
Last inspected
25 October 2005
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8204028 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
238819
Flag
MARSHALL ISLANDS
—
Maury page id
psix-238819

Inspections, by type

…with no type recorded31
Years with a record 19 calendar years (1984–2005)
The 45 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 21 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it45293 - Regulatory (Subpart C or D), Gross Ton
45293 - Convention (Subpart B), Gross Ton
25298 - Regulatory (Subpart C or D), Net Ton
25298 - Convention (Subpart B), Net Ton
80152 - Dead Weight, Ton
97032 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 45

25 October 2005 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2521942
23 October 2003 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1929674
11 April 2003 Annual Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1772239
8 April 2002 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1602494
27 March 2002 Deficiency Check · In-Service Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1598262
14 March 2002 Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1493652
14 August 2000 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 281050
8 June 2000 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 278766
18 January 2000 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 274158
28 May 1999 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 428467
26 May 1998 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 416410
26 May 1998 Tank Vessel Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1381272
21 March 1997 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 40530
21 March 1997 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 401607
14 April 1996 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 447651
12 February 1996 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 387484
24 December 1995 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 486347
27 March 1995 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 376584
9 March 1995 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 651676
10 February 1995 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 374782
11 December 1994 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 372758
30 October 1994 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 371888
25 May 1994 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 444381
12 December 1993 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 363011
12 December 1993 Certificate of Compliance · MARPOL Annex I Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 850111
12 April 1993 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 460564
22 June 1992 Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1258703
4 February 1992 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 436350
8 June 1991 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 344316
8 June 1991 Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 929852
1 May 1990 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 336687
1 May 1990 Certificate of Compliance
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 925952
30 November 1989 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 540513
12 April 1989 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 329557
2 April 1989 Certificate of Compliance · MARPOL Annex I Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1204510
12 July 1988 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 474671
14 March 1988 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 321994
14 March 1988 MARPOL Annex II Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1337895
3 March 1988 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 321535
27 October 1987 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 510540
30 March 1987 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 456049
30 March 1987 Certificate of Compliance
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1020430
26 October 1986 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 457486
21 February 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 307059
12 November 1984 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 298749

Deficiency record · 18

Lifesaving › Launching Appliances › Winch Brake
Issued 25 October 2005 Resolved
Stbd lifeboat remote lowerin wire not arranged to allow for lowering lifeboat to the water. SOLAS 74/78 Ch. III Reg.20 Sec.2. Vessel required to ammend/change abandon ship and lifeboat lowering instructions to reflect use of a brakeman on deck (not using remote lowering wire). Provide proof to COTP prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 October 2005
Resolved 26 October 2005
Resolution: Sector LA/LB PSC received updated instructions.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 23 October 2003 Resolved
Make Inert Gas System for cargo holds operational or provide exemption certificate for cargo hold fixed fire extinguisher system from class prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 October 2003
Resolution: Received class report.
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 11 April 2003 Resolved
No. 6 fuel oil injection pump on No. 2 auxiliary diesel generator is spraying fuel oil. LEGACY COMPONENT DESC: Distributor (fuel injection)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2003
Resolved 11 April 2003
Resolution: Deficiency rectified before departure of boarding team.
Electrical › Electrical Distribution System (service)
Issued 11 April 2003 Resolved
The 24V DC electrical distribution system has a dead ground. LEGACY COMPONENT DESC: Ground Detection
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 April 2003
Resolved 15 April 2003
Resolution: Received class report attesting to the removal of the 24VDC ground.
Engineering
Issued 11 April 2003 Resolved
Numerous piping systems throughout engine room compartment have patches installed. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 May 2003
Resolved 23 October 2003
Navigation › Collision/Grounding Avoidance
Issued 27 March 2002 Resolved
Secondary Marine Radar inoperable, 33 CFR 164.37. Provide service technician report of satisfactory repairs prior to departure from Houston, TX. LEGACY COMPONENT DESC: Radar
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 27 March 2002
Resolved 26 April 2002
Resolution: received satisfactory tech report that Secondary Marine Radar is operational..
Personnel › Certificates/Documents/Licenses
Issued 18 March 2002 Resolved
Not all crewmembers STCW 95 endorsements in compliance. STCW 95 I/14. Provide proof from flag state for all crew meeting endorsement requirements STCW 95. LEGACY COMPONENT DESC: STCW Endorsement
Due 1 August 2002
Resolved 11 April 2003
Resolution: Deficiency corrected during boarding.
Deck/Cargo
Issued 18 March 2002 Resolved
Steam leak in area of fwd port foam nozzel between #1 and #2 cargo tanks. SOLAS 74 (Amend) CH I Reg II Ch II-1 Reg 33. Submit report from class surveyor (Lloyds) verifying permanent repairs.
Due 2 April 2002
Resolved 8 April 2002
Resolution: Item corrected.
Lifesaving › Embarkation Appliances/Stations
Issued 18 March 2002 Resolved
Hydraulic leaks port/starboard pilot ladder control stations. SOLAS 74 (Amend) CH I Reg II. Submit class surveyor report (Lloyds) verifying permanent repairs.
Due 2 April 2002
Resolved 8 April 2002
Resolution: Item corrected.
Fire Fighting
Issued 8 June 2000 Resolved
3 SEPERATE HALON CANISTERS WERE OBSERVED TO BE OUT OF COMPLIANCE DUE TO OUTDATED SERVICE TAGS. VSL TO BE IN COMPLIANCE NLT 22 JUNE 2000.
Condition: Unknown
Due 13 June 2000
Resolved 16 June 2000
Navigation
Issued 28 May 1999 Resolved
GYRO COMPASS INOPERABLE. 33 CFR 164.35(d)
Condition: Unknown
Due 28 May 1999
Resolved 28 May 1999
Lifesaving
Issued 21 March 1997 Resolved
VSL'S STBD L/B RELEASING/RETRIEVING GEAR NOT FUNCTIONING. ISSUED REQUIREMENT FOR VSL'S CLASS TO SURVEY AND ISSUE REPORT. L/B RELEASING/RETRIEVING GEAR TO FUNCTION PROPERLY PRIOR TO DEPARTURE.
Condition: Unknown
Due 21 March 1997
Resolved 25 March 1997
Construction/Loadline
Issued 10 February 1995 Resolved
PAINT LOAD LINES ON THE PORT AND STBD SIDES WITH A COLOR THAT CONTRASTS THECOLOR OF THE VESSEL'S HULL.
Condition: Unknown
Due 10 February 1995
Resolved 16 February 1995
Lifesaving
Issued 10 February 1995 Resolved
STENCIL LIFEBOAT DIMENSIONS ON THE EXTERIOR OF THE PORT AND STBD LIFEBOATS.
Condition: Unknown
Due 10 February 1995
Resolved 16 February 1995
Deck/Cargo
Issued 10 February 1995 Resolved
VENT OUTLETS FROM ALL TANKS WHICH MAY EMIT FLAMMABLE OR COMBUSTIBLE VAPORS,SUCH AS BILGE SLOP TANKS AND CONTAMINATED DRAIN TANKS, MUST BE FITTED WITH A SINGLE SCREEN OF CORROSION RESISTANT WIRE. SHIP HAD NO FLAME SCREENS IN TANK VENTS.
Condition: Unknown
Due 28 March 1995
Resolved 28 March 1995
Deck/Cargo
Issued 10 February 1995 Resolved
A SHIP 1600 GROSS TONS OR MORE MUST HAVE A FIXED CONTAINER OR ENCLOSED_x001C_ DECK AREA UNDER OR AROUND EACH FUEL OIL OR BULK LUBRICATING OIL TANK VENT, OVERFLOW, AND FILL PIPE, THAT HAS A CAPACITY OF ONE BARREL. THIS SHIP HAD TWO CONTAINMENT VIOLATIONS.
Condition: Unknown
Due 28 March 1995
Resolved 28 March 1995
Navigation
Issued 14 March 1988 Resolved
U.S.C.G. LIGHT LIST VOL III NOT O/B VSL. FOREIGN EQUIVALENT LIGHT LIST, B.AVOL "J" CORRECTED THRU MARCH 1987.
Condition: Unknown
Due 8 May 1988
Resolved 14 March 1988
Navigation
Issued 14 March 1988 Resolved
TIDE TABLES, FOR 1988, NOT O/B VSL. NO OTHER ALTERNATE INFORMATION CONCERN-ING TIDES O/B VSL.
Condition: Unknown
Due 8 May 1988
Resolved 14 March 1988

Ownership record