A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Electrical
Issued 18 November 1987
Resolved
REPAIR GENERAL ALARM BELLS AND BEACON IN PORT AND STBD PUMP ROOMS AND IN THE ENGINE ROOM. ALSO STENCIL GENERAL ALARM CONTACT MAKER LOCATED ON DRILL FLOOR.
Condition: Unknown
Due 18 November 1987
Resolved 18 November 1987
Fire Fighting
Issued 18 November 1987
Resolved
REPLACE ALL EX-607 HOSES LOCATED THROUGHOUT VESSEL. 33 CFR 143.207(B) AND 46 CFR 108.491.
Condition: Unknown
Due 18 November 1987
Resolved 18 November 1987
Deck/Cargo
Issued 18 November 1987
Resolved
REMOVE DIESEL FUEL TANKS PRESENTLY MOUNTED AFT OF FIRE STATIONS #12 AND #14ON MAIN DECK, OR PROVIDE A DEADMAN NOZZLE, APPROPRIATE HOSE, NOZZLE CONTAINMENT AREA AND FLAME SCREEN FOR VENT. PRESENT SYSTEM IS UNACCEPTABLE. 33 CFR 143.207(B) AND 46 CFR 108.239.
Condition: Unknown
Due 18 November 1987
Resolved 18 November 1987
Construction/Loadline
Issued 18 November 1987
Resolved
REPAINT DRAFT MARKS IN A CONTRASTING COLOR. MARKINGS PRESENTLY TO FADED TO DISCERN. 33 CFR 143.207(B) AND 46 CFR 108.663.
Condition: Unknown
Due 18 November 1987
Resolved 18 November 1987
Construction/Loadline
Issued 18 November 1987
Resolved
REPAIR ELECTRIC MOTOR ON SEA SUCTION SEA VALVE IN STBD PUMP RM. ALSO MAKE HAND OPERABLE SEA SUCTION (FROZEN UP). (THESE ARE TWO DIFFERENT SEA VALVES IN STBD PUMP RM). 33 CFR 143.207(B) AND 46 CFR 108.625.
Condition: Unknown
Due 18 November 1987
Resolved 18 November 1987
Accommodation/Occupational Safety
Issued 18 November 1987
Resolved
REPLACE 150 PSI RELIEF VALVES ON ALL HOT WATER HEATERS WITH ONES SET AT 100 PSI OR BELOW AND 210 DEGREES F., OR MAKE TANKS AVAILABLE FOR INTERNAL INSPECTION.
Condition: Unknown
Due 18 November 1987
Resolved 18 November 1987
Deck/Cargo
Issued 18 November 1987
Resolved
PROVIDE COPY OF SATISFACTORY QUADRENNIAL TESTS ON THE THREE CRANES ON BOARDCRANES PRESENTLY PAST DUE AS OF 10NOV87. 33 CFR 146.205 AND 46 CFR 109.437.
Condition: Unknown
Due 18 November 1987
Resolved 18 November 1987
Documentation
Issued 20 November 1986
Resolved
PROVIDE CURRENT FMC CERTIFICATE.
Condition: Unknown
Due 20 November 1986
Resolved 20 November 1986
Construction/Loadline
Issued 20 November 1986
Resolved
REPAIR WATER TIGHT CARGO DOOR TO SUB-SEA SHOP.
Condition: Unknown
Due 27 February 1987
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 19 November 1985
Resolved
REPAIR DAMAGED PERIMETER SAFETY NET FOR HELICOPTER DECK REF 46 CFR108.235.
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985
Lifesaving
Issued 19 November 1985
Resolved
REPLACE MISSING CATWALK DECK GRADING AT STBD BOW EMERGENCY ESCAPE LADDER REF 46 CFR 108.525.
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985
Lifesaving
Issued 19 November 1985
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985
Deck/Cargo
Issued 19 November 1985
Resolved
PROVIDE APT HAND SIGNALS AT ALL CRANE CONTROL STATIONS REF 46 CFR 108.601
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985
Construction/Loadline
Issued 19 November 1985
Resolved
REPAIR ALL DOORS TO MUD PIT ROOM DOORS MVST SELF-CLOSE AND BE GAS TIGHT DOGS MUST BE ADJUSTED SO THAT DOOR DOES NOT FOUL WHEN SHUT REF 46 CFR 108.175 (C) (D).
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985
Unknown
Issued 19 November 1985
Resolved
MARK LOAD LINE ON VESSEL HULL, LOAD LINE TO BE VERIFIED BY ABS INSPECTOR (REF 46 CFR108.663.
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985
Unknown
Issued 19 November 1985
Resolved
REPAIR AND PAINT DRAFT MARKS AT EACH CORNER OF VESSEL REF 46 CFR108.661(3)/
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985
Fire Fighting
Issued 19 November 1985
Resolved
INSTALL ONE B-11 OR C-11 PORTABLE FIRE EXTINGUISHER IN EACH LAUNDRY ROOM REF.46 CFR 108.495 (A).
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985
Unknown
Issued 19 November 1985
Resolved
PROVIDE PROOF THAT ALL AIR RECEIVERS PRESSURE VESSELS ARE DESIGNED, FABRICATED AND IDENTIFIED AS IN COMPLIANCE WITH THE REQUIREMENTS OF ASME, US COAST GUARD OF OTHER AUTHORITY RECOGNIZED BY THE FLAG ADMIN.
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985
Accommodation/Occupational Safety
Issued 19 November 1985
Resolved
PROVIDE STORM RAILS IN PASSAGEWAYS (ONE SIDE) REF 46CFR108/221(C).
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985
Lifesaving
Issued 19 November 1985
Resolved
REPAIR ALL DAMAGED EMERGENCY ESCAPE LADDERS LOCATED AT EACH CORNER OF VESSEL SO LOADERS CAN BE USED WHEN IS AT LIGHT DRAFT.
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985
Fire Fighting
Issued 19 November 1985
Resolved
PROVIDE FIRE HYDRANTS WITH 1 1/2 X 50' HOSE AT EACH ACCEES TO HELICOPTER DECK REF 46 CFR L08.186.
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985
Unknown
Issued 19 November 1985
Resolved
SUBMIT VESSEL OPERATING MANUAL TO COAST GUARD MERCHANT MARINE TECHNICAL OFFICE NEW ORLEANS (MMT) FOR COAST GUARD REVIEW REF 46 CFR 109.121.
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985
Fire Fighting
Issued 19 November 1985
Resolved
INSTALL ONE FIRE HYDRANT WITH FIRE HOSE AND COMBINATION NOZZLE ON DRILL FLOOR REF 46 CFR108.423.
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985
Unknown
Issued 19 November 1985
Resolved
REPAINT VESSEL NAME ON HULL REF 46 CFR 108.657
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985
Unknown
Issued 19 November 1985
Resolved
MARK VESSEL HAILING PORT ON HULL (REF 46 CFR108.675).
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985
Accommodation/Occupational Safety
Issued 19 November 1985
Resolved
PROVIDE A SINGLE BERTH OR EXAMINATION TABLE THAT IS ACCESSIBLE FROM BOTH SIDES FOR HOSPITAL TREATMENT ROOM REF 46108.210
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985
Navigation
Issued 19 November 1985
Resolved
REMOVE SIGN FROM IN FRONT OF OBSTRUCTION LIGHTS LOCATED AT PORT BOW.
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985
Lifesaving
Issued 19 November 1985
Resolved
MARK GENERAL ALARM BELL IN MUD-PUMP ROOM (REF 46CFR-108.625).
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985
Fire Fighting
Issued 19 November 1985
Resolved
PROVIDE A 10 FT APPLICATOR AT EACH ACCESS TO HELICOPTER DECK REF 46 CFR108.425(D) (2).
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985
Navigation
Issued 26 October 1984
Resolved
PROVIDE HELOPAD LANDING LIGHTS WITH CHARACTERISTICS IN ACCORDANCE WITH 46 CFR 241(A)(2) (ALTERNATING BLUE AND AMBER).
Condition: Unknown
Due 26 October 1984
Resolved 26 October 1984
Construction/Loadline
Issued 26 October 1984
Resolved
INSTALL HELICOPTER TIE DOWNS IN ACCORDANCE WITH 46 CFR 108.235(3).
Condition: Unknown
Due 26 October 1984
Resolved 26 October 1984
Unknown
Issued 26 October 1984
Resolved
INSTALL CABLE CLIPS ON BREAKOUT TONGS.
Condition: Unknown
Due 26 October 1984
Resolved 26 October 1984
Accommodation/Occupational Safety
Issued 26 October 1984
Resolved
CONDUCT HYDROSTATIC TEST OR INTERNAL INSPECTION ON #1,4 CEMENT TANKS, #1,#3BARITE TANKS, AND ALL AIR RECEIVERS.
Condition: Unknown
Due 26 October 1984
Resolved 26 October 1984