MAURY USCG vessel records Sign in
← All vessels

PENROD 70

PENROD 70 is a 1973 mobile offshore drilling unit. The Coast Guard has recorded 10 inspections since 1984, most recently in January 1988, along with 33 deficiencies.

Records from 1984 to 1988. Most recent: inspection, 6 January 1988.

Built
1973
Last inspected
6 January 1988
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

238820
Flag
PANAMA
—
Maury page id
psix-238820

Inspections, by type

…with no type recorded7
Years with a record 5 calendar years (1984–1988)
The 10 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 38 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it6042 - Regulatory (Subpart C or D), Gross Ton
4227 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 10

6 January 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1318059
18 November 1987 Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1013349
25 June 1987 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1019615
20 November 1986 Deficiency Check · Certificate of Compliance
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1013571
21 August 1986 Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1013229
12 June 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 994967
14 May 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1302567
4 December 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1296909
19 November 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1296382
26 October 1984 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1286784

Deficiency record · 33

Electrical
Issued 18 November 1987 Resolved
REPAIR GENERAL ALARM BELLS AND BEACON IN PORT AND STBD PUMP ROOMS AND IN THE ENGINE ROOM. ALSO STENCIL GENERAL ALARM CONTACT MAKER LOCATED ON DRILL FLOOR.
Condition: Unknown
Due 18 November 1987
Resolved 18 November 1987
Fire Fighting
Issued 18 November 1987 Resolved
REPLACE ALL EX-607 HOSES LOCATED THROUGHOUT VESSEL. 33 CFR 143.207(B) AND 46 CFR 108.491.
Condition: Unknown
Due 18 November 1987
Resolved 18 November 1987
Deck/Cargo
Issued 18 November 1987 Resolved
REMOVE DIESEL FUEL TANKS PRESENTLY MOUNTED AFT OF FIRE STATIONS #12 AND #14ON MAIN DECK, OR PROVIDE A DEADMAN NOZZLE, APPROPRIATE HOSE, NOZZLE CONTAINMENT AREA AND FLAME SCREEN FOR VENT. PRESENT SYSTEM IS UNACCEPTABLE. 33 CFR 143.207(B) AND 46 CFR 108.239.
Condition: Unknown
Due 18 November 1987
Resolved 18 November 1987
Construction/Loadline
Issued 18 November 1987 Resolved
REPAINT DRAFT MARKS IN A CONTRASTING COLOR. MARKINGS PRESENTLY TO FADED TO DISCERN. 33 CFR 143.207(B) AND 46 CFR 108.663.
Condition: Unknown
Due 18 November 1987
Resolved 18 November 1987
Construction/Loadline
Issued 18 November 1987 Resolved
REPAIR ELECTRIC MOTOR ON SEA SUCTION SEA VALVE IN STBD PUMP RM. ALSO MAKE HAND OPERABLE SEA SUCTION (FROZEN UP). (THESE ARE TWO DIFFERENT SEA VALVES IN STBD PUMP RM). 33 CFR 143.207(B) AND 46 CFR 108.625.
Condition: Unknown
Due 18 November 1987
Resolved 18 November 1987
Accommodation/Occupational Safety
Issued 18 November 1987 Resolved
REPLACE 150 PSI RELIEF VALVES ON ALL HOT WATER HEATERS WITH ONES SET AT 100 PSI OR BELOW AND 210 DEGREES F., OR MAKE TANKS AVAILABLE FOR INTERNAL INSPECTION.
Condition: Unknown
Due 18 November 1987
Resolved 18 November 1987
Deck/Cargo
Issued 18 November 1987 Resolved
PROVIDE COPY OF SATISFACTORY QUADRENNIAL TESTS ON THE THREE CRANES ON BOARDCRANES PRESENTLY PAST DUE AS OF 10NOV87. 33 CFR 146.205 AND 46 CFR 109.437.
Condition: Unknown
Due 18 November 1987
Resolved 18 November 1987
Documentation
Issued 20 November 1986 Resolved
PROVIDE CURRENT FMC CERTIFICATE.
Condition: Unknown
Due 20 November 1986
Resolved 20 November 1986
Construction/Loadline
Issued 20 November 1986 Resolved
REPAIR WATER TIGHT CARGO DOOR TO SUB-SEA SHOP.
Condition: Unknown
Due 27 February 1987
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 19 November 1985 Resolved
REPAIR DAMAGED PERIMETER SAFETY NET FOR HELICOPTER DECK REF 46 CFR108.235.
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985
Lifesaving
Issued 19 November 1985 Resolved
REPLACE MISSING CATWALK DECK GRADING AT STBD BOW EMERGENCY ESCAPE LADDER REF 46 CFR 108.525.
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985
Lifesaving
Issued 19 November 1985 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985
Deck/Cargo
Issued 19 November 1985 Resolved
PROVIDE APT HAND SIGNALS AT ALL CRANE CONTROL STATIONS REF 46 CFR 108.601
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985
Construction/Loadline
Issued 19 November 1985 Resolved
REPAIR ALL DOORS TO MUD PIT ROOM DOORS MVST SELF-CLOSE AND BE GAS TIGHT DOGS MUST BE ADJUSTED SO THAT DOOR DOES NOT FOUL WHEN SHUT REF 46 CFR 108.175 (C) (D).
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985
Unknown
Issued 19 November 1985 Resolved
MARK LOAD LINE ON VESSEL HULL, LOAD LINE TO BE VERIFIED BY ABS INSPECTOR (REF 46 CFR108.663.
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985
Unknown
Issued 19 November 1985 Resolved
REPAIR AND PAINT DRAFT MARKS AT EACH CORNER OF VESSEL REF 46 CFR108.661(3)/
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985
Fire Fighting
Issued 19 November 1985 Resolved
INSTALL ONE B-11 OR C-11 PORTABLE FIRE EXTINGUISHER IN EACH LAUNDRY ROOM REF.46 CFR 108.495 (A).
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985
Unknown
Issued 19 November 1985 Resolved
PROVIDE PROOF THAT ALL AIR RECEIVERS PRESSURE VESSELS ARE DESIGNED, FABRICATED AND IDENTIFIED AS IN COMPLIANCE WITH THE REQUIREMENTS OF ASME, US COAST GUARD OF OTHER AUTHORITY RECOGNIZED BY THE FLAG ADMIN.
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985
Accommodation/Occupational Safety
Issued 19 November 1985 Resolved
PROVIDE STORM RAILS IN PASSAGEWAYS (ONE SIDE) REF 46CFR108/221(C).
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985
Lifesaving
Issued 19 November 1985 Resolved
REPAIR ALL DAMAGED EMERGENCY ESCAPE LADDERS LOCATED AT EACH CORNER OF VESSEL SO LOADERS CAN BE USED WHEN IS AT LIGHT DRAFT.
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985
Fire Fighting
Issued 19 November 1985 Resolved
PROVIDE FIRE HYDRANTS WITH 1 1/2 X 50' HOSE AT EACH ACCEES TO HELICOPTER DECK REF 46 CFR L08.186.
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985
Unknown
Issued 19 November 1985 Resolved
SUBMIT VESSEL OPERATING MANUAL TO COAST GUARD MERCHANT MARINE TECHNICAL OFFICE NEW ORLEANS (MMT) FOR COAST GUARD REVIEW REF 46 CFR 109.121.
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985
Fire Fighting
Issued 19 November 1985 Resolved
INSTALL ONE FIRE HYDRANT WITH FIRE HOSE AND COMBINATION NOZZLE ON DRILL FLOOR REF 46 CFR108.423.
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985
Unknown
Issued 19 November 1985 Resolved
REPAINT VESSEL NAME ON HULL REF 46 CFR 108.657
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985
Unknown
Issued 19 November 1985 Resolved
MARK VESSEL HAILING PORT ON HULL (REF 46 CFR108.675).
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985
Accommodation/Occupational Safety
Issued 19 November 1985 Resolved
PROVIDE A SINGLE BERTH OR EXAMINATION TABLE THAT IS ACCESSIBLE FROM BOTH SIDES FOR HOSPITAL TREATMENT ROOM REF 46108.210
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985
Navigation
Issued 19 November 1985 Resolved
REMOVE SIGN FROM IN FRONT OF OBSTRUCTION LIGHTS LOCATED AT PORT BOW.
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985
Lifesaving
Issued 19 November 1985 Resolved
MARK GENERAL ALARM BELL IN MUD-PUMP ROOM (REF 46CFR-108.625).
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985
Fire Fighting
Issued 19 November 1985 Resolved
PROVIDE A 10 FT APPLICATOR AT EACH ACCESS TO HELICOPTER DECK REF 46 CFR108.425(D) (2).
Condition: Unknown
Due 19 November 1985
Resolved 19 November 1985
Navigation
Issued 26 October 1984 Resolved
PROVIDE HELOPAD LANDING LIGHTS WITH CHARACTERISTICS IN ACCORDANCE WITH 46 CFR 241(A)(2) (ALTERNATING BLUE AND AMBER).
Condition: Unknown
Due 26 October 1984
Resolved 26 October 1984
Construction/Loadline
Issued 26 October 1984 Resolved
INSTALL HELICOPTER TIE DOWNS IN ACCORDANCE WITH 46 CFR 108.235(3).
Condition: Unknown
Due 26 October 1984
Resolved 26 October 1984
Unknown
Issued 26 October 1984 Resolved
INSTALL CABLE CLIPS ON BREAKOUT TONGS.
Condition: Unknown
Due 26 October 1984
Resolved 26 October 1984
Accommodation/Occupational Safety
Issued 26 October 1984 Resolved
CONDUCT HYDROSTATIC TEST OR INTERNAL INSPECTION ON #1,4 CEMENT TANKS, #1,#3BARITE TANKS, AND ALL AIR RECEIVERS.
Condition: Unknown
Due 26 October 1984
Resolved 26 October 1984

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.