MAURY USCG vessel records Sign in
← All vessels

ALBERTA

ALBERTA is a 1984 freight ship. The Coast Guard has recorded 21 inspections since 1984, most recently in April 2008, along with 15 deficiencies and 2 operational controls.

Records from 1984 to 2008. Most recent: operational control imposed, 8 April 2008.

Built
1984
Last inspected
7 April 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8323197 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
238964
Flag
MALTA
—
Maury page id
psix-238964

Inspections, by type

…with no type recorded17
Years with a record 16 calendar years (1984–2008)
The 21 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it12032 - Convention (Subpart B), Net Ton
22215 - Convention (Subpart B), Gross Ton
37611 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 21

7 April 2008 MARPOL Annex V Examination · ISPS II Exam · PII Safety Exam · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3177342
20 June 2006 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2685754
14 July 2005 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2426121
10 December 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2257653
9 December 2004 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2256060
16 July 2004 ISPS II Exam · PII Safety Exam
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2134983
5 December 2001 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 296076
30 January 2000 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 274204
20 May 1999 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 428699
11 August 1998 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 419092
16 March 1998 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 459791
9 October 1997 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 408578
25 October 1996 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 396869
22 January 1995 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 530707
12 August 1994 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 369358
15 February 1994 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 364506
21 January 1994 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 489383
12 February 1990 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 335283
8 March 1988 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 321973
9 January 1986 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 306382
5 November 1984 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 298781

Deficiency record · 15

Fire Fighting › Fire Main › Condition
Issued 8 April 2008 Resolved
During operational test of emergency fire pump, fire main ruptured between No. 4 and No. 5 cargo holds. Repair and attest to the structural integrity of the fire main. Repair to the satisfaction of class.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 April 2008
Resolution: ABS provided report stating repairs were completed to there satisfaction. See attached report "ABS_Firemain"
Lifesaving › Lifeboat Equipment › Food Ration
Issued 14 July 2005 Resolved
Starboard / Port lifeboat rations damaged. Replace damaged food rations. 24 port and 5 starboard for a total of 29 food rations totaling not less than 10,000kj each. Fax receipt to attending, marine inspector prior to departure port of Baltimore.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 14 July 2005
Resolved 21 July 2005
Resolution: Received invoice for purchase of 30 "USCG approved" food rations.
Lifesaving › Embarkation Appliances/Stations › Side Ropes
Issued 14 July 2005 Resolved
Starboard side embarkation ladder worn at main eye. Replace / repair to the satisfaction of attending marine inspector.
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 July 2005
Resolved 21 July 2005
Resolution: Starboard side embarkation ladder was repaired to the satisfaction of the attending Coast Guard Marine Inspector.
Engineering › Steering Gear System › Motor
Issued 14 July 2005 Resolved
Steering gear pump motors #1 and #2 are leaking at actuator valve seals. Repair / replace to the satisfaction of attending marine inspector
Action required: 705 - Other - as specified
Due 14 August 2005
Resolved 21 July 2005
Resolution: Steering gear pump motors #1 and #2 were repaired and are no longer leaking.
Accommodation/Occupational Safety › Ventilation › General
Issued 14 July 2005 Resolved
MSD vent pipe above unit was wasted and holed. Repair / replace to satisfaction of Coast Guard Marine inspector.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 August 2005
Resolved 21 July 2005
Resolution: MSD vent pipe was repaired to the satisfaction of the USCG marine inspector.
Fire Fighting
Issued 30 January 2000 Resolved
FIRE DOOR BETWEEN ENGINE ROOM AND STEERING GEAR ROOM WOULD NOT SELF CLOSE AND WOULD NOT FIT THE DOOR JAM. SOLAS II/2 REG. 47/1
Condition: Unknown
Due 5 December 2001
Resolved 5 December 2001
Lifesaving
Issued 11 August 1998 Resolved
LIMIT SWITCHES ON LIFEBOAT INOPERABLE. CREW USES MANUAL HANDLE AND PNEUMATTIC MOTOR SIMULTANEOUSLY. REPAIR/RENEW AND PROVIDE CLASS_x001C_ REPORT PRIOR TO RETURNING TO U.S. WATERS.
Condition: Unknown
Due 20 May 1999
Resolved 20 May 1999
Engineering
Issued 11 August 1998 Resolved
NO MECHANICAL MEANS OF CLOSURE IN BUNKER CONTAINMENT. REPAIR/RENEW PRIOR TO BUNKERING IN U.S. WATERS.
Condition: Unknown
Due 20 May 1999
Resolved 20 May 1999
Engineering
Issued 11 August 1998 Resolved
NO ANNUAL HYDROSTATIC TEST OF BUNKERING PIPELINES. CONDUCT HYDROSTATIC TEST AND PROVIDE DOCUMENTATION PRIOR TO RETURNING TO U.S. WATERS.
Condition: Unknown
Due 20 May 1999
Resolved 20 May 1999
Engineering
Issued 11 August 1998 Resolved
NO.1 AND NO.2 GENERATORS HAVE SOFT PATCH ON SALT WATER COOLING LINES. REPAIR/RENEW AND PROVIDE CLASS REPORT PRIOR TO RETURNING TO U.S. WATERS.
Condition: Unknown
Due 20 May 1999
Resolved 20 May 1999
Fire Fighting
Issued 11 August 1998 Resolved
CREW UNFAMILIAR WITH USING FIRE FIGHTING GEAR. DEMONSTRATE PROPER USAGE PRIOR TO DEPARTURE. PROVIDE DOCUMENTATION FROM COMPANY THAT ISM ADDRESES THE PROBLEM.
Condition: Unknown
Due 20 May 1999
Resolved 20 May 1999
Deck/Cargo
Issued 11 August 1998 Resolved
HYDRAULIC LINE ON NO.1 CARGO HATCH HOLD HAS A SOFT PATCH. VESSEL TO REPAIR/RENEW AND PROVIDE CLASS REPORT PRIOR TO RETURNING TO U.S. WATERS.
Condition: Unknown
Due 20 May 1999
Resolved 20 May 1999
Navigation
Issued 12 February 1990 Resolved
A VIO OF 33CFR164.33(B)IN THAT BRITISH ADMIRALTY SAILING DIRECTIONS VOL 69,USED BY THE VSL WERE NOT CORRECTED WITH B.A. SUPPLEMENT 6 WHICH WAS REA- SONABLY AVAILABLE & CONTAINED CORRECTIONS APPLICABLE TO VSL'S ROUTE FROM VACAPES TO ELIZABETH RIVER TERMINAL, CHESAPEAKE, VA. NO U.S. PUB O/B.
Condition: Unknown
Due 12 February 1990
Resolved 12 February 1990
Navigation
Issued 8 March 1988 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 8 March 1988
Resolved 8 March 1988
Unknown
Issued 8 March 1988 Resolved
VESSEL OIL TRANSFER PROCEDURES DID NOT CONTAIN INFORMATION REQUIRED BY 33 CFR 155.750.
Condition: Unknown
Due 8 March 1988
Resolved 8 March 1988

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.