MAURY USCG vessel records Sign in
← All vessels

GULF FLEET NO. 70

GULF FLEET NO. 70 is a 1984 offshore supply vessel. The Coast Guard has recorded 54 inspections since 1984, most recently in December 2003, along with 85 deficiencies.

Records from 1984 to 2003. Most recent: inspection, 29 December 2003.

Built
1984
Last inspected
29 December 2003
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8311596 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WTB3955
238992
Flag
UNITED STATES
338437000, 369365000 (licence lapsed)
Maury page id
psix-238992

Inspections, by type

…with no type recorded9
Years with a record 20 calendar years (1984–2003)
The 54 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 23 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it315 - Regulatory (Subpart C or D), Net Ton
464 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDB7009MMSI 369365000 · cancelled · compulsorily equipped · granted 30 March 2004, cancelled 15 April 2004
WBT3955MMSI 338437000 · cancelled · compulsorily equipped · granted 25 January 1999, cancelled 15 April 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 54

29 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1976582
4 May 2003 Periodic Inspection
Physical examination · Activities Europe · Activity 1750672
4 March 2003 Deficiency Check
Physical examination · Activities Europe · Activity 1752293
18 September 2002 Periodic Inspection
Physical examination · Activities Europe · Activity 1671191
12 September 2002 Hull Examination · Internal Structural Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1674565
8 August 2001 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1069429
15 April 2001 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1468206
23 March 2000 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 816391
7 February 2000 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1365548
17 August 1999 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1113501
22 March 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 811498
2 March 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 800026
6 January 1999 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1386392
19 December 1998 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 808711
6 March 1998 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1460156
6 June 1997 Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1099321
28 May 1997 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1111141
28 April 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1101310
23 April 1997 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1094456
6 January 1997 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1383417
18 March 1996 Administrative
Administrative · Activities Europe - OLD · USCG Northeast District (CGD-NE) · Activity 884610
5 March 1996 Deficiency Check
Physical examination · Activities Europe - OLD · USCG Northeast District (CGD-NE) · Activity 1077441
11 January 1996 Re-Inspection
Physical examination · Activities Europe - OLD · USCG Northeast District (CGD-NE) · Activity 877040
21 April 1995 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1179666
4 January 1995 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 840301
26 June 1994 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 861336
20 April 1994 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1170123
8 March 1994 Re-Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 855852
16 February 1993 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 832319
30 September 1992 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1250256
20 July 1992 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 957870
15 July 1992 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 955510
7 July 1992 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1250175
17 April 1992 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1263791
3 March 1992 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1265172
11 March 1991 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 903745
2 November 1990 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1227525
4 September 1990 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1216973
5 July 1990 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1242107
31 January 1990 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1220112
3 May 1989 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1345912
6 December 1988 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1209716
18 November 1988 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 893763
7 November 1988 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 895136
23 February 1988 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1028093
17 September 1987 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1316781
17 July 1987 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1340784
5 May 1987 Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1025452
21 January 1987 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1319673
6 November 1986 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1016153
29 January 1986 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 993501
7 September 1985 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1302341
28 February 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 980440
9 October 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 982401

Deficiency record · 85

Lifesaving › Visual Distress Signals (General) › Condition
Issued 4 May 2003 Resolved
Repair power source for signal lamp on bridge
Condition: Improper/Lack of Maintenance
Due 4 May 2003
Resolved 4 May 2003
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 4 May 2003 Resolved
Replace accommodation ladder on portside
Condition: Improper/Lack of Maintenance
Due 4 May 2003
Resolved 4 May 2003
Construction/Loadline › Structures › Door
Issued 4 May 2003 Resolved
Replace gasket for watertight doors
Condition: Improper/Lack of Maintenance
Due 4 May 2003
Resolved 4 May 2003
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 4 May 2003 Resolved
Replace and test cargo PV's relief valves
Condition: Improper/Lack of Maintenance
Due 4 May 2003
Resolved 4 May 2003
Electrical › Electrical Distribution System (service) › Switchboard
Issued 1 May 2003 Resolved
Replace mat in front of switchboard.
Condition: Improper/Lack of Maintenance
Due 4 May 2003
Resolved 4 May 2003
Resolution: Replaced
Deck/Cargo › Holds/Tanks › Independent Tank
Issued 1 May 2003 Resolved
Install flame safety screen on gasoline storage locker.
Condition: Improper/Lack of Maintenance
Due 4 May 2003
Resolved 4 May 2003
Construction/Loadline › Structures
Issued 23 October 2002 Resolved
Crop and renew wastage between frames 60 and frames 62 along the starboard longitudinal bulkhead below the cable run. All repairs must be made to the satisfaction of the attending ABS surveyor. A survey report must be provided to the MIO Europe. Vessel must make permanent repairs by 23Nov02. LEGACY COMPONENT DESC: Longitudinal Bulkhead
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 November 2002
Resolved 9 November 2002
Resolution: As per ABS survey report
Construction/Loadline › Structures
Issued 23 October 2002 Resolved
Crop and renew wastage port aft bulkhead in the chain locker (approx 2.5 m x 2 m) All repairs must be made to the satisfaction of the attending ABS surveyor. A survey report must be provided to the MIO Europe. Vessel must make permanent repairs by 23Nov02. LEGACY COMPONENT DESC: Longitudinal Bulkhead
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 November 2002
Resolved 9 November 2002
Resolution: As per ABS survey report
Construction/Loadline › Hull
Issued 23 October 2002 Resolved
Crop and renew wastage port side shell between frames 09 -07 port anchor chain locker (approx 2 m up from the deck). All repairs must be made to the satisfaction of the attending ABS surveyor. A survey report must be provided to the MIO Europe. Vessel must make permanent repairs by 23Nov02. LEGACY COMPONENT DESC: Hull Plating
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 November 2002
Resolved 9 November 2002
Resolution: As per ABS survey report
Construction/Loadline › Structures
Issued 23 October 2002 Resolved
Crop and renew wasted transverse (frame 4) port anchor chain locker. All repairs must be made to the satisfaction of the attending ABS surveyor. A survey report must be provided to the MIO Europe. Vessel must make permanent repairs by 23Nov02. LEGACY COMPONENT DESC: Transverse Bulkhead
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 November 2002
Resolved 9 November 2002
Resolution: As per ABS survey report
Construction/Loadline › Structures
Issued 23 October 2002 Resolved
Crop and renew wastage longitudinal aft bulkhead starboard anchor chain locker (approx 2.5 m x 2 m). All repairs must be made to the satisfaction of the attending ABS surveyor. A survey report must be provided to the MIO Europe. Vessel must make permanent repairs by 23Nov02. LEGACY COMPONENT DESC: Longitudinal Bulkhead
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 November 2002
Resolved 9 November 2002
Resolution: As per ABS survey report
Construction/Loadline › Hull
Issued 23 October 2002 Resolved
Crop and renew wastage starboard side shell between frames 10 - 7 starboard anchor chain locker (approx 2 m up ). All repairs must be made to the satisfaction of the attending ABS surveyor. A survey report must be provided to the MIO Europe. Vessel must make permanent repairs by 23Nov02. LEGACY COMPONENT DESC: Hull Plating
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 November 2002
Resolved 9 November 2002
Resolution: As per ABS survey report
Construction/Loadline › Structures
Issued 23 October 2002 Resolved
Crop and renew wasted transverse (frame 4 and 7) starboard anchor chain locker. All repairs must be made to the satisfaction of the attending ABS surveyor. A survey report must be provided to the MIO Europe. Vessel must make permanent repairs by 23Nov02. LEGACY COMPONENT DESC: Transverse Bulkhead
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 November 2002
Resolved 9 November 2002
Resolution: As per ABS survey report
Construction/Loadline › Structures
Issued 23 October 2002 Resolved
Crop and renew wasted deck longitudinal. 4th longitudinal from interior bulkhead under P-tank No. 5, #3 aft stbd void. All repairs must be made to the satisfaction of the attending ABS surveyor. A survey report must be provided to the MIO Europe. Vessel must make permanent repairs by 23Nov02.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 November 2002
Resolved 9 November 2002
Resolution: As per ABS survey report
Construction/Loadline › Hull
Issued 23 October 2002 Resolved
Crop and renew bottom plate under P-tank No. 5 between 3rd & 4th deck longitudinals from interior bulkhead, #3 stbd void aft. All repairs must be made to the satisfaction of the attending ABS surveyor. A survey report must be provided to the MIO Europe. LEGACY COMPONENT DESC: Bottom Plating
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 November 2002
Resolved 9 November 2002
Resolution: As per ABS survey report
Construction/Loadline › Structures
Issued 23 October 2002 Resolved
Ensure support beams are renewed for pressure vessels No. 5 and No. 3, Beams are located closest to the center inboard of #3 starboard void aft. All repairs must be made to the satisfaction of the attending ABS surveyor. A survey report must be provided to the MIO Europe.
Action required: 705 - Other - as specified
Due 23 November 2002
Resolved 9 November 2002
Resolution: As per ABS survey report
Documentation › Certificates/Documents
Issued 18 September 2002 Resolved
The Certificate of Financial Responsibility was found not valid. The vessel may operate with out a valid certificate while outside of U. S. waters. The vessel must have a valid Certificate of Responsibility prior to entry into U. S. waters. LEGACY COMPONENT DESC: Certificate of Financial Responsibility
Action required: 15 - Rectify deficiencies by next port
Resolved 4 May 2003
Navigation
Issued 18 September 2002 Resolved
Vessel must properly allign the magnetic compass and provide a current compass deviation card prior to operations.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 November 2002
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 18 September 2002 Resolved
All fire extinguishers must be hydrostatically tested. LEGACY COMPONENT DESC: Condition
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 October 2002
Resolution: All portable fire extinguishers were found to be within the hydro testing requirments.
Deck/Cargo › Mooring/Anchoring
Issued 18 September 2002 Resolved
Make permanent repairs to the starboard anchor windlass. LEGACY COMPONENT DESC: Anchor
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 October 2002
Resolution: Starboard anchor windlass was found to be in proper operations.
Deck/Cargo › Holds/Tanks
Issued 18 September 2002 Resolved
Make permanent repairs to all tank vent pipes and ensure proper flames screens are in place.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 October 2002
Resolution: All tank vent pipes were renewed with the proper flame screens.
Accommodation/Occupational Safety › Washroom/Toilet
Issued 18 September 2002 Resolved
Provide hot water to the bathroom sinks on the main deck, forward of galley. LEGACY COMPONENT DESC: Hot and Cold Running Water
Due 18 October 2002
Resolved 18 October 2002
Resolution: Hotwater facet was installed.
Accommodation/Occupational Safety › Occupational Safety
Issued 18 September 2002 Resolved
Ensure engine room emergency escape hatches, located on the deck, can be opened with ease from the inside.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 October 2002
Resolution: Port and starboard engine room emergency escape hatches were fitted with additional counter weights and found to be in working order.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 18 September 2002 Resolved
Replace wasted liquid mud pipe aft of forward engine room bulkhead, .1meter starboard forward engine room hatch. LEGACY COMPONENT DESC: Piping
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 October 2002
Resolution: Pipe was cleaned of cement and found not to be wasted.
Construction/Loadline › Structures
Issued 18 September 2002 Resolved
Crop and renew wasted port side floors at frames 18 and 20. All repairs must be made to the satisfaction of the attending ABS surveyor. A survey report must be provided to the MIO Europe. Vessel must make permanent repairs by 23Nov02. LEGACY COMPONENT DESC: Deck Plating
Action required: 705 - Other - as specified
Due 23 November 2002
Resolved 9 November 2002
Resolution: As per ABS survey report
Construction/Loadline › Structures
Issued 18 September 2002 Resolved
Crop and renew wastage between frames 57 - 60 stbd along cable run. All repairs must be made to the satisfaction of the attending ABS surveyor. A survey report must be provided to the MIO Europe. Vessel must make permanent repairs by 23Nov02. LEGACY COMPONENT DESC: Longitudinal Bulkhead
Action required: 705 - Other - as specified
Due 23 November 2002
Resolved 9 November 2002
Resolution: As per ABS survey report
Construction/Loadline › Structures
Issued 18 September 2002 Resolved
Crop and renew wastage between frames 26-28 port below deck plate. All repairs must be made to the satisfaction of the attending ABS surveyor. A survey report must be provided to the MIO Europe. Vessel must make permanent repairs by 23Nov02. LEGACY COMPONENT DESC: Longitudinal Bulkhead
Action required: 705 - Other - as specified
Due 23 November 2002
Resolved 9 November 2002
Resolution: As per ABS survey report
Construction/Loadline › Hull
Issued 18 September 2002 Resolved
Crop and renew pitting between frames 19-21 stbd.. All repairs must be made to the satisfaction of the attending ABS surveyor. A survey report must be provided to the MIO Europe. Vessel must make permanent repairs by 23Nov02. LEGACY COMPONENT DESC: Bottom Plating
Action required: 705 - Other - as specified
Due 23 November 2002
Resolved 9 November 2002
Resolution: As per ABS survey report
Construction/Loadline › Structures
Issued 18 September 2002 Resolved
Crop and renew wastage stbd emergency escape, aft bulkhead. All repairs must be made to the satisfaction of the attending ABS surveyor. A survey report must be provided to the MIO Europe. Vessel must make permanent repairs by 23Nov02. LEGACY COMPONENT DESC: Trunk
Action required: 705 - Other - as specified
Due 23 November 2002
Resolved 9 November 2002
Resolution: As per ABS survey report
Lifesaving › Embarkation Appliances/Stations
Issued 18 September 2002 Resolved
Provide jacobs ladder or other means for ships crew to disembark from vessel to life raft on the port side embarkation station. LEGACY COMPONENT DESC: Side Ropes
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 November 2002
Resolution: As per ABS survey report
Engineering › Fuel Oil Storage/Transfer System
Issued 18 September 2002 Resolved
Diesel liquid level indicating device shall be of heat resistant materials and adequately protected from mechanical damage or provided at the tank connections with devices which will automatically close. LEGACY COMPONENT DESC: Gauge
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 November 2002
Construction/Loadline › Structures
Issued 18 September 2002 Resolved
Crop and renew doubler plate port emergency escape, outboard bulkhead. All repairs must be made to the satisfaction of the attending ABS surveyor. A survey report must be provided to the MIO Europe. Vessel must make permanent repairs by 23Nov02. LEGACY COMPONENT DESC: Trunk
Action required: 705 - Other - as specified
Due 23 November 2002
Resolved 9 November 2002
Resolution: As per ABS survey report
Construction/Loadline › Structures
Issued 18 September 2002 Resolved
Crop and renew wastage, port side emergency escape, outer bulkhead. All repairs must be made to the satisfaction of the attending ABS surveyor. A survey report must be provided to the MIO Europe. Vessel must make permanent repairs by 23Nov02. LEGACY COMPONENT DESC: Trunk
Action required: 705 - Other - as specified
Due 23 November 2002
Resolved 9 November 2002
Resolution: As per ABS survey report
Construction/Loadline › Structures
Issued 18 September 2002 Resolved
Crop and renew wasted deck plate framing between frames 26-28. All repairs must be made to the satisfaction of the attending ABS surveyor. A survey report must be provided to the MIO Europe. Vessel must make permanent repairs by 23Nov02. LEGACY COMPONENT DESC: Deck Plating
Action required: 705 - Other - as specified
Due 23 November 2002
Resolved 9 November 2002
Resolution: As per ABS survey report
Construction/Loadline › Structures
Issued 18 September 2002 Resolved
Crop and renew wastage between frames 49 and frames 52 along the starboard longitudinal bulkhead below the cable run. All repairs must be made to the satisfaction of the attending ABS surveyor. A survey report must be provided to the MIO Europe. Vessel must make permanent repairs by 23Nov02. LEGACY COMPONENT DESC: Longitudinal Bulkhead
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 November 2002
Resolved 9 November 2002
Resolution: As per ABS survey report
Electrical
Issued 15 April 2001 Resolved
Replace missing buttons on engine room automation panel and re-lable all.
Condition: Unknown
Due 15 April 2001
Resolved 15 April 2001
Deck/Cargo
Issued 15 April 2001 Resolved
Repair and prove operation of starboard anchor windlass.
Condition: Unknown
Due 17 April 2001
Resolved 17 April 2001
Fire Fighting
Issued 15 April 2001 Resolved
Repair broken mount footing on fire monitor pump.
Condition: Unknown
Due 15 April 2001
Resolved 15 April 2001
Lifesaving
Issued 15 April 2001 Resolved
Provide copies of certification for vessel's life rafts.
Condition: Unknown
Due 15 April 2001
Resolved 15 April 2001
Fire Fighting
Issued 15 April 2001 Resolved
Provide annual certification evidencing annual weighing and testing of vessel's fixed CO2 system.
Condition: Unknown
Due 15 April 2001
Resolved 15 April 2001
Lifesaving
Issued 15 April 2001 Resolved
Repair and prove operation of vessel's GMDSS.
Condition: Unknown
Due 15 April 2001
Resolved 15 April 2001
Fire Fighting
Issued 15 April 2001 Resolved
Repair broken fire monitor pump mount and align drive shaft.
Condition: Unknown
Due 15 April 2001
Resolved 15 April 2001
Lifesaving
Issued 15 April 2001 Resolved
Provide appropriate equipment for rescue boat.
Condition: Unknown
Due 15 April 2001
Resolved 15 April 2001
Construction/Loadline
Issued 15 April 2001 Resolved
Repair crossover pip in forward engine room bilge.
Condition: Unknown
Due 15 April 2001
Resolved 15 April 2001
Fire Fighting
Issued 15 April 2001 Resolved
Replace wasted fire monitor pump foundation.
Condition: Unknown
Due 17 April 2001
Resolved 17 April 2001
Lifesaving
Issued 15 April 2001 Resolved
Replace hydrostatic release on EPIRB. Hydrostatic release_x001C_ expires 30 APril 2001. If not replaced by 30 April 2001, vessel_x001C_ is in a no-sail status on 01 MAY 01.
Condition: Unknown
Due 15 April 2001
Resolved 15 April 2001
Fire Fighting
Issued 15 April 2001 Resolved
Renew wasted fire monitor pump foundation and re-align pump to engine.
Condition: Unknown
Due 15 April 2001
Resolved 15 April 2001
Lifesaving
Issued 7 February 2000 Resolved
DEMONSTRATE PROPER OPERATION OF RESCUE PLATFORM AND ASSOCIATED EQUIPMENT INACCORDANCE WITH D8 POLICY LETTER DATED 12 NOV 98.
Condition: Unknown
Due 7 March 2000
Resolved 11 April 2000
Unknown
Issued 6 January 1999 Resolved
FABRICATE NEW RESCUE BOAT DAVIT TO ACCOMADATE CURRENT RESCUE BOAT AND DEMONSTRATE PROPER OPERATION.
Condition: Unknown
Due 6 January 1999
Resolved 6 January 1999
Fire Fighting
Issued 6 March 1998 Resolved
UPDATE/CORRECT FIRE SAFETY PLAN WITH CORRECT LOCATION AND TYPE OF EQUIPMENT.
Condition: Unknown
Due 6 March 1998
Resolved 6 March 1998
Lifesaving
Issued 6 January 1997 Resolved
PROVIDE ONBOARD A LEGIBLE AND UPDATED COPY OF FIRE AND SAFETY PLAN.
Condition: Unknown
Due 6 January 1997
Resolved 6 January 1997
Electrical
Issued 5 March 1996 Resolved
PROVE PROPER OPERATION OF REVERSE POWER RELAYS ON BOTH S/S GENERATORS
Condition: Unknown
Due 5 March 1996
Resolved 5 March 1996
Accommodation/Occupational Safety
Issued 11 January 1996 Resolved
PROVE PROPER OPERATION OF POTABLE WATER TANK RELIEF VALVE.
Condition: Unknown
Due 11 January 1996
Resolved 11 January 1996
Accommodation/Occupational Safety
Issued 11 January 1996 Resolved
PROVE PROPER OPERATION OF SANITARY WATER TANK RELIEF VALVE.
Condition: Unknown
Due 11 January 1996
Resolved 11 January 1996
Electrical
Issued 11 January 1996 Resolved
PROVE PROPER OPERATION OF REVERSE POWER RELAYS ON BOTH S/S GENERATORS.
Condition: Unknown
Due 11 January 1996
Resolved 11 January 1996
Navigation
Issued 11 January 1996 Resolved
PROVE PROPER OPERATION OF EMERGENCY STEERING STATION RUDDER ANGLE INDICATOR.
Condition: Unknown
Due 11 January 1996
Resolved 11 January 1996
Lifesaving
Issued 11 January 1996 Resolved
INSTALL PROTECTIVE GUARDS AROUND SIGHT GLASS TUBES, PORT SIDE ENGINE ROOM.
Condition: Unknown
Due 11 January 1996
Resolved 11 January 1996
Lifesaving
Issued 11 January 1996 Resolved
PROVE PROPER OPERATION OF 406 MHZ EPIRB._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 January 1996
Resolved 11 January 1996
Engineering
Issued 11 January 1996 Resolved
PROVIDE ONBOARD COPY OF COAST GUARD APPROVED TEST PROCEDURES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 January 1996
Resolved 11 January 1996
Fire Fighting
Issued 11 January 1996 Resolved
INSTALL UL APPROVED FIRE EXTINGUISHER & BRACKET FOR STBD SIDE PAINT LOCKER.
Condition: Unknown
Due 11 January 1996
Resolved 11 January 1996
Unknown
Issued 11 January 1996 Resolved
PROVIDE ONBOARD CURRENT COPY OF REQUIRED REGULATIONS.
Condition: Unknown
Due 11 January 1996
Resolved 11 January 1996
Lifesaving
Issued 11 January 1996 Resolved
PROVIDE ONBOARD CAOST GUARD APPROVED AND INSPECTED LIFERAFTS._x001C_
Condition: Unknown
Due 11 January 1996
Resolved 11 January 1996
Electrical
Issued 11 January 1996 Resolved
INSTALL LEAD LINING FOR ENGINE ROOM BATTERY BOX.
Condition: Unknown
Due 11 January 1996
Resolved 11 January 1996
Deck/Cargo
Issued 11 January 1996 Resolved
MAKE PERMANENT REPAIRS IN WAY OF RED HAND PATCH ON LIQUID MUD DISCHARGE PIPE.
Condition: Unknown
Due 11 January 1996
Resolved 11 January 1996
Documentation
Issued 17 April 1992 Resolved
SUBMIT DRAWINGS AND EQUIPMENT LIST, AS INSTALLED, OF THE DISPERSENCE SYSTEMTO U.S. COAST GUARD MARINE INSPECTION OFFICE, NEW YORK, FOR APPROVAL._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 April 1992
Resolved 17 April 1992
Documentation
Issued 17 April 1992 Resolved
SUBMIT STABILITY INFORMATION ON NEWLY INSTALLED DISPERSENCE SYSTEM TO U.S. COAST GUARD MARINE SAFETY CENTER (G-MSC-1) FOR RE-ISSUING OF STABILITY LETTER._x001C_
Condition: Unknown
Due 17 April 1992
Resolved 17 April 1992
Engineering
Issued 3 March 1992 Resolved
PROVE PROPER OPERATION OF OILY WATER SEPERATOR._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 June 1992
Resolved 11 June 1992
Fire Fighting
Issued 3 March 1992 Resolved
HYDRO TEST OR REPLACE CO2 BOTTLE IN FIXED SYSTEM FOR PAINT LOCKER._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 March 1992
Resolved 3 March 1992
Fire Fighting
Issued 3 March 1992 Resolved
PROVIDE DRAWING OF CO2 FIXED FIRE EXTINGUISHING SYSTEM AND UP TO DATE INSTRUCTIONS FOR OPERATION OF SAME._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 June 1992
Resolved 11 June 1992
Fire Fighting
Issued 3 March 1992 Resolved
HYDRO TEST OR REPLACE ACTUATOR BOTTLE IN CO2 FIXED SYSTEM REMOTE PULL STATION._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 March 1992
Resolved 3 March 1992
Electrical
Issued 3 March 1992 Resolved
PROVE PROPER OPERATION OF #1 SHIP SERVICE GENERATOR TRIPS AND ALARMS.
Condition: Unknown
Due 11 June 1992
Resolved 11 June 1992
Fire Fighting
Issued 3 March 1992 Resolved
PROVIDE COPY OF LATEST SERVICING REPORT FOR FIRE FIGHTING SYSTEMS (PORTABLEAND FIXED). IF OLDER THAN ONE YEAR HAVE SYSTEMS SERVICED AND PROVIDE COPY OF REPORT._x001C_ _x001C_
Condition: Unknown
Due 11 June 1992
Resolved 11 June 1992
Unknown
Issued 11 March 1991 Resolved
PROVIDE FCC ISSUED SAFETY RADIO CERTIFICATE AS REQUIRED BY 47 CFR 80.851.
Condition: Unknown
Due 11 March 1991
Resolved 11 March 1991
Deck/Cargo
Issued 31 January 1990 Resolved
PROVIDE VESSEL WITH PORT ANCHOR.
Condition: Unknown
Due 31 January 1990
Resolved 31 January 1990
Engineering
Issued 31 January 1990 Resolved
PROVIDE ALL ENGINEROOM SIGHT GLASSES WITH PROTECTIVE RODS.
Condition: Unknown
Due 31 January 1990
Resolved 31 January 1990
Fire Fighting
Issued 31 January 1990 Resolved
PROVIDE ENGINEROOM FIXED CO2 SYSTEM WITH OPERABLE TWENTY-FIVE (25) SECOND TIME DELAY.
Condition: Unknown
Due 31 January 1990
Resolved 31 January 1990
Fire Fighting
Issued 31 January 1990 Resolved
REPAIR LEAKING FIRE MONITOR PUMP.
Condition: Unknown
Due 31 January 1990
Resolved 31 January 1990
Accommodation/Occupational Safety
Issued 31 January 1990 Resolved
PROVIDE MSD VALVE WITH VALVE HANDLE.
Condition: Unknown
Due 31 January 1990
Resolved 31 January 1990
Electrical
Issued 31 January 1990 Resolved
REPAIR DOGS ON EMERGENCY BATTERY BOX.
Condition: Unknown
Due 31 January 1990
Resolved 31 January 1990
Electrical
Issued 31 January 1990 Resolved
PROPERLY BLOCK BATTERIES IN EMERGENCY BATTERY BOX
Condition: Unknown
Due 31 January 1990
Resolved 31 January 1990
Electrical
Issued 31 January 1990 Resolved
PROPERLY SUPPORT ALL WIRING ON THE FLYING BRIDGE.
Condition: Unknown
Due 31 January 1990
Resolved 31 January 1990
Navigation
Issued 31 January 1990 Resolved
UPDATE ALL CHARTS TO THE LATEST NOTICE TO MARINERS.
Condition: Unknown
Due 31 January 1990
Resolved 31 January 1990
Navigation
Issued 31 January 1990 Resolved
PROVIDE VESSEL WITH MAGNETIC COMPASS DEVIATION TABLE.
Condition: Unknown
Due 31 January 1990
Resolved 31 January 1990
Unknown
Issued 7 November 1988 Resolved
DEMONSTRATE THE STARBOARD SS AIR RECEIVER RELIEF VALVE OPERATION BY TESTINGIN THE PRESENCE OF A MARINE INSPECTOR, IN ACCORDANCE WITH 46 CFR 54.15-5.
Condition: Unknown
Due 7 November 1988
Resolved 7 November 1988
Deck/Cargo
Issued 17 July 1987 Resolved
PORT POSITIVE DISPLACEMENT LIQUID MUD PUMP SHALL NOT BE USED FOR ANY PURPOSE UNTIL (1.) PUMP IS OPERATIONAL AND TESTED, (2.) RELIEF VALVE IS INSTALLED AND TESTED ON DISCHARGE SIDE OF PUMP, (3.) PIPING IS HYDROTESTED TO PROPER PRESSURE AND STABILITY IS APPROVED BY MARINE SAFETY CENTER.
Condition: Unknown
Due 17 July 1987
Resolved 17 July 1987

Ownership record