← All vessels
SEA RAINBOW
SEA RAINBOW is a 1983 freight ship. The Coast Guard has recorded 38 inspections since 1984, most recently in July 2009, along with 15 deficiencies and 7 operational controls.
Records from 1984 to 2009. Most recent: inspection, 24 July 2009.
- Built
- 1983
- Last inspected
- 24 July 2009
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 15 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8307179 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
VRZR6
239156
Flag
PANAMA
—
Maury page id
psix-239156
Inspections, by type
The 38 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it12680 - Convention (Subpart B), Net Ton
22361 - Convention (Subpart B), Gross Ton
38325 - Dead Weight, Ton
22361 - Convention (Subpart B), Gross Ton
38325 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 38
24 July 2009
PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3543682
26 May 2008
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3217927
24 January 2008
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3135518
23 January 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3133156
13 April 2006
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2624644
31 March 2006
Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2613866
27 March 2006
PII Safety Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2611766
12 March 2005
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2566949
23 February 2005
NPV Safety Exam · MARPOL Annex II Examination · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2297518
9 December 2004
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2256507
8 December 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2256004
19 November 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2244648
28 May 2004
MTSA/ISPS Verification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2080699
25 May 2004
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2079687
28 April 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2067831
25 January 2004
Security Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1992413
20 February 2003
Ballast Water Examination · Passenger/Freight Vessel Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1748565
4 February 2003
Security Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1739969
26 March 2001
Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 288508
21 October 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 283251
13 April 1999
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 427294
9 July 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 405620
4 July 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 143049
5 August 1996
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 393987
7 January 1995
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 701195
27 December 1994
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 464592
18 May 1994
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 701196
11 May 1994
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 366717
13 June 1993
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 358875
17 September 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 339374
30 April 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 507065
27 October 1989
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 333244
9 August 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 324991
27 January 1988
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 538029
6 May 1987
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 315896
20 July 1986
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 438844
26 August 1985
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 303871
8 November 1984
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 298837
Deficiency record · 15
Electrical › Electrical Distribution System (emergency) › Conductor
Issued 24 July 2009
Resolved
1677 Accumulator batteries for emergency power appear to have two conductors disconnected in a main power run. The emergency system connected to these wires in unknown.
SOLAS 74un/am Ch II/2 Reg 26
70a/b
Construction/Loadline › Structures › Air Pipe
Issued 24 July 2009
Resolved
1275 Aft peak tank air vent tubes located in steering are wasted and leaking, possibly leading to flooding steering gear space.
ICLL 66 Reg I/20
70a/b
Fire Fighting › Structural - A Class Divisions › Door Frames
Issued 24 July 2009
Resolved
0987 Entrance to engine control room: Above door bulkhead has began to crack and run. No corrective action will lead to fire boundary being compromised.
SOLAS 74un/am Ch. I/II
70a/b
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 24 July 2009
Resolved
1099 Electrical cable trunk & linen stores are being used for storage of flammable materials both areas have not been identified on fire control plan to meet proper storage.
SOLAS 74un/am Ch. II/2 Reg 2
70a/b
Lifesaving › Launching Appliances › Winch
Issued 24 July 2009
Resolved
0684 Starboard side limit switch for life boat to prevent overstressing of wire ropes is not properly working. Request to have Class check for proper operation of both Port & Starboard limit switches.
SOLAS 74un/am Ch. 3 Reg 36(k)
70a/b
Fire Fighting › Fire Main › Condition
Issued 27 March 2006
Resolved
Fire main leaking in the vicinity of number 1 and number 2 cargo hold. Repairs required to be complete to the satisfaction of class in 7 days.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 27 March 2006
Resolved
Fire control plan did not reflect fire control plan key.
Deck/Cargo
Issued 21 October 2000
Resolved
NO RECORD OF INSPECTIONS FOR CARGO SECURING DEVICES AS PER APPROVED CARGO SECURING MANUAL (SOLAS 74 [AMENDED] VI/5.6): INSPECT CARGO SECURING DEVICESAND LOG.
Documentation
Issued 5 August 1996
Resolved
PROVIDE LIBERIAN CERTIFICATES OF COMPETENCY FOR THE [name withheld], THIRD OFFICER, RADIO OFFICER, SECOND ENGINEER, THIRD ENGINEER, AND FORUTH ENGINEER PRIOR TO DEPARTURE FROM PORT.
Engineering
Issued 11 May 1994
Resolved
ON 11MAY94, THE VESSEL WAS BOARDED AND FOUND TO BE BUNKERING WITHOUT ANY CLOSURE DEVICES IN SCUPPERS AND WITH WOOD PLUGS IN THE FUEL OIL CONTAINMENT
Documentation
Issued 11 May 1994
Resolved
VESSEL'S OIL TRANSFER PROCEDURES WERE MISSING A DESCRIPTION OF AND MEANS TOEMPTY THE CONTAINMENT.
Documentation
Issued 11 May 1994
Resolved
THE VESSEL'S OIL TRANSFER PROCEDURES WERE MISSING THE MEANS OF COMMUNICATION.
Navigation
Issued 13 June 1993
Resolved
CHART 18751 NOT ON BOARD.
Navigation
Issued 6 May 1987
Resolved
NOS CHARTS 18720, 18746 AND 18751 NOT CORRECTED TO DATE.
Navigation
Issued 6 May 1987
Resolved
NOS CHART 18720 MISSING CORRECTION NTM 10/87 NOS CHART 18749 NOT CORRECTED TO DATE
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.