SANKO PRELUDE
SANKO PRELUDE is a 1984 freight ship. The Coast Guard has recorded 26 inspections since 1984, most recently in February 2005, along with 8 deficiencies and 1 operational control.
Records from 1984 to 2005. Most recent: inspection, 16 February 2005.
- Built
- 1984
- Last inspected
- 16 February 2005
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 8 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8309141 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
VRXY9
239452
Flag
HONG KONG
—
Maury page id
psix-239452
Inspections, by type
The 26 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 21 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it8373 - Convention (Subpart B), Net Ton
14147 - Convention (Subpart B), Gross Ton
23904 - Dead Weight, Ton
29243 - Displacement, Ton
14147 - Convention (Subpart B), Gross Ton
23904 - Dead Weight, Ton
29243 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 26
16 February 2005
Ballast Water Examination · MARPOL Annex I Examination · ISPS II Exam · PII Safety Exam
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2293161
25 January 2004
Type not recorded
No type recorded · USCGC KISKA (WPB 1336) · USCG Oceania District (CGD-O) · Activity 1996079
19 November 2003
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1950932
6 November 2003
Annual Inspection · Deficiency Check · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1943390
31 January 2003
Annual Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1738145
26 January 2001
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 286588
9 March 1998
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 413412
8 March 1997
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 55550
8 March 1997
Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 94868
4 March 1997
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 401226
13 May 1996
Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 391026
16 February 1996
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 387433
6 July 1995
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 379952
30 January 1995
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 374609
26 August 1994
Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 370030
1 February 1994
Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 364220
24 October 1992
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 353815
25 July 1991
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 344912
6 June 1990
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 337579
4 May 1989
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 330172
23 January 1988
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 320793
25 November 1987
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 319789
30 June 1987
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 317568
27 June 1987
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 316899
11 June 1986
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 309442
9 November 1984
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 298938
Deficiency record · 8
Engineering › Steering Gear System
Issued 6 November 2003
Resolved
Steering Gear system is not operating as designed. In all modes of bridge control the rudder hunts 2 to 4 degrees. In local operation in the steering compartment the system drifts to port with no command. If allowed the system will drift hard to port. LEGACY COMPONENT DESC: Motor
Electrical › Electrical Distribution System (service)
Issued 6 November 2003
Resolved
220 electrical switchboard has a ground on one of three phases of power. LEGACY COMPONENT DESC: Ground Detection
Fire Fighting › Fire Pumps
Issued 31 January 2003
Resolved
The emergency fire pump fills the compartment with an excessive amount of crankcase gases coming from the lube oil fill tube vent.
Fire Fighting › Fire Pumps
Issued 31 January 2003
Resolved
The emergency fire pump flywheel guard does not cover the bottom half of the flywhee, leaving it exposed when rotating.
The emergency fire pump flywheel guard did not cover the bottom half of the flywheel leaving it exposed when rotating.
LEGACY COMPONENT DESC: Flywheel
Engineering › Fuel Oil Service System
Issued 31 January 2003
Resolved
The fuel oil heater has a temporary patch on the steam outlet piping, and has a noteworthy leak.
LEGACY COMPONENT DESC: Heater
Navigation
Issued 27 June 1987
Resolved
VESSEL TRANSITED COOS BAY TO COOS BAY, OR. WITHOUT HAVING ONBOARD A COPY OFTHE INLAND NAVIGATION RULES.
Navigation
Issued 27 June 1987
Resolved
VESSEL TRANSITED COOS BAY TO COOS BAY, OR. WITHOUT CONDUCTING AND LOGGING THE EMERGENCY STEERING DRILL.
Navigation
Issued 27 June 1987
Resolved
VESSEL TRANSITED COOS BAY TO COOS BAY, OR. WITHOUT HAVING ONBOARD A LIGHT LIST FOR THE AREA NAVIGATED CURRENTLY CORRECTED AND UP TO DATE.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.