CAP'N BERT

CAP'N BERT is a 1982 passenger vessel (inspected). The Coast Guard has recorded 49 inspections since 1994, most recently in August 2026, along with 65 deficiencies and 1 casualty investigation in 2008.

Records from 1994 to 2026. Most recent: inspection, 4 August 2026.

Built
1982
Last inspected
4 August 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WTF5456
239558
Flag
UNITED STATES
367318410
Maury page id
psix-239558

Inspections, by type

…with no type recorded3
Years with a record 27 calendar years (1994–2026)
The 49 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)49.0 ft × 18.7 ft × 6.2 ft
Registered tonnagegross 42 / net 29
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPENINSULAR MARINE ENT · KEY WEST, FL, UNITED STATES · built 1982
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portKINGSTON, RI
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 18 February 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it42 - Regulatory (Subpart C or D), Gross Ton
29 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WTF5456MMSI 367318410 · active · voluntarily equipped · granted 26 October 2017, expires 24 December 2027
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 49

4 August 2026 Internal Structural Exam · Annual Inspection · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8456813
1 July 2025 COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8166491
8 October 2024 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8003986
19 August 2024 Hull Examination · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7971148
31 May 2024 Drydock Extension
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7924332
28 September 2023 Administrative Inspection · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7789703
19 July 2022 Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7497206
25 May 2022 Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7434527
13 July 2021 Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7238110
22 July 2020 Drydock Exam · Internal Structural Exam · Hull Examination · Examination of Repairs · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6985721
16 July 2020 COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6985718
8 October 2019 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6818843
18 October 2018 Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6548562
28 August 2018 Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6513624
15 May 2018 Construction Oversight · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6408865
10 August 2017 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6191626
8 August 2016 DAPI Audit · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5880101
8 August 2016 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6002171
29 September 2011 DAPI Audit · Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4157169
20 July 2011 Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4088393
10 December 2009 Re-Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3645686
17 July 2009 Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3537339
6 November 2008 Deficiency Check · Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3349548
28 April 2008 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3206053
1 November 2007 Hull Examination · Re-Inspection · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3077468
20 September 2006 Re-Inspection · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2757001
27 July 2005 COI Inspection · Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2441541
24 November 2004 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2195767
25 August 2004 Internal Structural Exam · Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2175254
29 March 2004 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2033024
22 October 2002 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1690076
26 August 2002 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1664242
4 April 2002 Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1600492
29 November 2001 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1376837
26 February 2001 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 104542
14 February 2001 Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1057947
30 August 2000 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 821951
30 August 2000 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1369817
27 October 1999 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1412022
1 October 1998 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1400863
10 September 1998 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 800180
15 September 1997 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1111421
3 October 1996 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1147314
28 August 1996 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1377804
29 January 1996 Excursion Permit
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1193566
6 December 1995 Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 878164
11 October 1995 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1186171
30 August 1995 Excursion Permit
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 884390
16 September 1994 Initial Certification · Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1155869

Deficiency record · 65

11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 August 2026 Resolved
Each ring life buoy on a vessel must be approved in accordance with § 160.050 in sub-chapter Q of this chapter. Life buoy plug failed causing water intrusion into lifebuoy exceeding approved weight and reducing overall buoyancy. Replace W/in 14 days.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2026
Resolved 13 August 2026
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 4 August 2026 Resolved
Each survival craft must be Secured to the vessel by a painter with a float-free link. Float-free link was sized incorrectly. Replace W/in 14 days.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2026
Resolved 13 August 2026
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 August 2026 Resolved
Each distribution panel must be totally enclosed and of the dead front type. 12V panel busbar exposed due to missing blank cover or spare breaker. Replace W/in 14 days.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2026
Resolved 13 August 2026
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 1 July 2025 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. One of the webbing straps on the 10 person buoyant apparatus is degraded and torn and no longer in a serviceable condition. Repair or replace.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2025
Resolved 31 July 2025
Resolution: Repaired
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 1 July 2025 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. The 12 person buoyant apparatus has multiple areas of exposed foam. Repair the vinyl or replace.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2025
Resolved 31 July 2025
Resolution: Repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 1 July 2025 Resolved
Each item of lifesaving equipment with an expiration date on it must be replaced if the expiration date has passed. The battery for the 12 person BA floating waterlight was expired and not operational. Replace.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2025
Resolved 10 July 2025
Resolution: New battery installed
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 July 2025 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Renew the grabline on the vessel's ring life buoy.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2025
Resolved 10 July 2025
Resolution: Renewed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 July 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards. Two exposed wires were present under the steering console. Remove the electrical wires or place in an enclosure.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2025
Resolved 10 July 2025
Resolution: Removed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 July 2025 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. Mark the fuel shutoff valve locations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2025
Resolved 10 July 2025
Resolution: Labeled.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 October 2024 Resolved
Each small battery installation must be located in a well ventilated space and protected from falling objects. Provide cover for installed generator battery.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 November 2024
Resolved 26 October 2024
Resolution: Cleared to the satisfaction of the Coast Guard
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 October 2024 Resolved
Each floating waterlight must be approved in accordance with § 161.010 in subchapter Q. Waterlight battery to be of approved type to ensure light floats and light signals at proper distance.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 November 2024
Resolved 26 October 2024
Resolution: Cleared to the satisfaction of the Coast Guard
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 October 2024 Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. Vessel to keep up to date alcohol test strips onboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 November 2024
Resolved 26 October 2024
Resolution: Cleared to the satisfaction of the Coast Guard
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 28 September 2023 Resolved
The float-free link required by § 180.130(a)(1) must be Of proper strength for the size of the life float or buoyant apparatus as indicated on its identification tag. Life floats are rated for 12 persons weak links are undersized based on installed rating of 6-10 persons.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2023
Resolved 28 September 2023
Resolution: Operator provided objective evidence of properly installed weak-links.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 19 July 2022 Resolved
Distress signals on board were expired. Master could not locate recently purchased updated flares while marine inspector on board.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 19 July 2022
Resolved 19 July 2022
Resolution: Vessel master found distress signals and sent photo evidence
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 19 July 2022 Resolved
Vessel master could not locate EPIRB registration while CG marine inspector on board.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 19 July 2022
Resolved 19 July 2022
Resolution: Vessel master located EPIRB registration & sent photo evidence.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 13 July 2021 Resolved
Each survival craft on a vessel must be in good working order and ready for immediate use before the vessel leaves the port and at all times when the vessel is underway. Inspector found life-float in un-serviceable condition. (dry rotted, cracked and core exposed). Replace life float in accordance (IAW) with 46 CFR 180.200, approved under approval series 160.027. The vessel is restricted to no more than 20 passengers iaw the survival craft requirements in table 46 CFR 180.200 (c).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 August 2021
Resolved 23 September 2021
Resolution: See Activity Number 7238110
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 16 July 2020 Resolved
No Waste Management Plan posted
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2020
Resolved 17 July 2020
Resolution: Posted Garbage Management Plan
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 16 July 2020 Resolved
MMSI not inputted in radio 47 CFR 80
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2020
Resolved 17 July 2020
Resolution: MMSI inputted into radios
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 18 October 2018 Resolved
STEERING RAM MOUNT BRACKET LOOSE/PLAY, EXCESSIVE MOVEMENT.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 October 2018
Resolved 25 October 2018
Resolution: REMOUNTED WITH LARGER DIAMETER BOLTS.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 18 October 2018 Resolved
DEMONSTRATE OPERATION OF SYSTEM BY TESTING
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 October 2018
Resolved 25 October 2018
Resolution: TESTED TO SAT OF ATTENDING CG MI
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 18 October 2018 Resolved
vent duct dented, closing device not operational.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 October 2018
Resolved 25 October 2018
Resolution: repaired.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 18 October 2018 Resolved
not updated.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 October 2018
Resolved 25 October 2018
Resolution: new print on demand.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 18 October 2018 Resolved
unable to demonstrate drills(all) not fully manned.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 October 2019
Resolution: Completed approx 1 week ofter the 2018 annual exam, but never cleared in MISLE.
Deck/Cargo › Mooring/Anchoring › Mooring Arrangement
Issued 10 August 2017 Resolved
P/S fwd mooring bitts are heavily rusted/scaling. In need of replacement in kind.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 October 2017
Resolved 6 October 2017
Resolution: Vessel replaced both fwd p/s mooring cleats to the satisfaction of MI.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 8 August 2016 Resolved
no crew list avail until school starts.
Action required: 705 - Other - as specified
Due 13 September 2016
Resolved 13 September 2016
Resolution: Crew covered list provided.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 8 August 2016 Resolved
Complete drills when school starts.
Action required: 705 - Other - as specified
Due 13 September 2016
Resolved 13 September 2016
Resolution: Completed drills with new crew.
Lifesaving › Lifefloat › Serviceable
Issued 29 September 2011 Resolved
Renew life float or repair coating.
Action required: 705 - Other - as specified
Due 29 October 2011
Resolved 27 October 2011
Fire Fighting › Remote Fuel Shutoff › General
Issued 10 December 2009 Resolved
Properly label the emergency fuel shut off valves. - the paint is worn and faded.
Action required: 705 - Other - as specified
Due 10 January 2010
Resolved 5 January 2010
Resolution: Witnessed fuel shut off valves to be properly stenciled.
Electrical › Lighting (service) › Lighting Fixture
Issued 7 December 2009 Resolved
Replace the missing light fixture cover on the aft on the pilothouse.
Action required: 705 - Other - as specified
Due 10 January 2010
Resolved 5 January 2010
Resolution: Witnessed light fixture cover repaired and reinstalled.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 7 December 2009 Resolved
Replace the return hose on the back-up hydarulic system. - the hose is cracked at the pump conncetion.
Action required: 705 - Other - as specified
Due 10 January 2010
Resolved 5 January 2010
Resolution: Witnessed return hose to be newly replaced and properly installed SAE J1527-A2 hose. Hose is as original.
Engineering › Steering Gear System › Hydraulic Hose
Issued 7 December 2009 Resolved
Correct the leaking hydraulic fittings on the lazarrette and tool room hydarulics.
Action required: 705 - Other - as specified
Due 10 January 2010
Resolved 5 January 2010
Resolution: Witnessed no leaks of residual hydraulic oil in the lazarette.
Lifesaving › Buoyant Apparatus › Retroreflective Material
Issued 7 December 2009 Resolved
Install new reflective tape on both buoyant apparatuses.
Action required: 705 - Other - as specified
Due 10 January 2010
Resolved 5 January 2010
Resolution: Witnessed newly installed retroreflective tape on the BA''s.
Navigation › Piloting/Steering › Marine Charts
Issued 7 December 2009 Resolved
Obtain new up to date charts.
Action required: 705 - Other - as specified
Due 31 December 2009
Resolved 5 January 2010
Resolution: Witnessed newly purchased up to date chart on board the vessel.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 4 December 2009 Resolved
Missed RIN due NLT 29NOV09. Conduct RIN prior to carriage of passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 December 2009
Resolved 10 December 2009
Resolution: RIN completed on this date. Review of vessel logs and interview with master revealed that no carriage of passengers occurred after the RIN due date. Not forwarded to Investigations at this time.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 6 November 2008 Resolved
Repair or replace 01 child PFD. An approved child PFD must be provided for each person under 90lbs.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 December 2008
Resolved 1 December 2008
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 6 November 2008 Resolved
Provide EAP requirements for the Dug & Alcohol Program.
Action required: 705 - Other - as specified
Due 1 December 2008
Resolved 1 December 2008
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 6 November 2008 Resolved
Address leak from shaft packing during the next regularly scheduled dry-dock period.
Action required: 705 - Other - as specified
Due 30 November 2009
Resolved 1 December 2008
Resolution: Changed deficncy to a special note for the next dry-dock period.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 20 September 2006 Resolved
Renew expired 6-volt batteries in buoyant apparatus water lights.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 October 2006
Resolved 16 October 2006
Resolution: Verified installation of new 6-volt batteries in ring buoy water lights. All sat.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 20 September 2006 Resolved
Renewe broken hose clamp on starboard MDE exhaust flex-piece in lazarette.
Action required: 705 - Other - as specified
Due 20 October 2006
Resolved 4 October 2006
Resolution: New clamp properly installed. Witnessed by attending marine inspector.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 20 September 2006 Resolved
Perform underway Man Overboard and Fire Drills with crew in the presence of a Marine Inspector.
Action required: 705 - Other - as specified
Due 20 October 2006
Resolved 4 October 2006
Resolution: MOB and fire fighting drills conducted and witnessed by attending Marine Inspector. All sat.
Engineering › Fuel Oil Service System › Valve, Control
Issued 27 July 2005 Resolved
Provide suitable stowage for deck plates (fuel shutoff) tools.
Action required: 705 - Other - as specified
Due 12 September 2005
Resolved 7 September 2005
Lifesaving › Buoyant Apparatus › Retroreflective Material
Issued 27 July 2005 Resolved
Replace retroreflective tape on BA.
Action required: 705 - Other - as specified
Due 12 September 2005
Resolved 7 September 2005
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 24 November 2004 Resolved
PROVIDE ASTM A53 SEAMLESS OR ERW PIPING FOR THE INSTALLED CO2 FIXED FIRE FIGHTING SYSTEM.
Due 25 February 2005
Resolved 23 February 2005
Resolution: Received call from [name withheld] stating FireEx had serviced the fixed fire fighting system. Awaiting fax copy.
Lifesaving › Buoyant Apparatus
Issued 29 March 2004 Resolved
Provide vessel name/persons/retro-reflective tape for BA
Due 6 April 2004
Resolved 12 April 2004
Resolution: Provided vessel name/persons/retro-reflective tape for BA
Lifesaving › Lifebuoys
Issued 29 March 2004 Resolved
Replace old ring buoy
Condition: Unknown
Due 6 April 2004
Resolved 12 April 2004
Resolution: Replaced the old ring.
Documentation › Markings/Placards
Issued 29 March 2004 Resolved
Provide life jacket placard
Condition: Unknown
Due 6 April 2004
Resolved 15 April 2004
Resolution: Bought placard for vessel.
Fire Fighting › Fixed Fire Detection System
Issued 29 March 2004 Resolved
Exercise smoke and heat detectors for ships system. LEGACY COMPONENT DESC: Heat Detectors
Condition: Unknown
Due 6 April 2004
Resolved 12 April 2004
Resolution: Showed Marine Inspector how the system works, and demonstrated test.
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 22 October 2002 Resolved
Prove proper annaul inspection of fixed fire system.
Due 5 December 2002
Resolved 4 December 2002
Construction/Loadline › Penetrations
Issued 22 October 2002 Resolved
Install new or repair aft main deck hatch.
Due 5 December 2002
Resolved 4 December 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 4 April 2002 Resolved
While conducting any business on the stern where no passengers are permitted, only crewmenbers may be in that area and must be wearing a type III life preserver. LEGACY COMPONENT DESC: Deck Rail
Due 29 June 2002
Resolved 22 October 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 4 April 2002 Resolved
Install stern railing and gate to satsfaction of CG Marine Inspector. LEGACY COMPONENT DESC: Deck Rail
Due 29 June 2002
Resolved 4 April 2002
System not recorded
Issued 29 November 2001 Resolved
INSPECT PORTABLE AND FIXED FIRE EXTINGUISHING SYSTEM PRIOR TO OPERATING WITH PASSENGERS.
Condition: Unknown
Due 29 November 2001
Resolved 4 April 2002
System not recorded
Issued 29 November 2001 Resolved
PROVIDE NAV RULES PUBLICATION.
Condition: Unknown
Due 6 December 2001
Resolved 4 April 2002
System not recorded
Issued 29 November 2001 Resolved
REPAIR COMPASS LIGHT.
Condition: Unknown
Due 6 December 2001
Resolved 4 April 2002
System not recorded
Issued 29 November 2001 Resolved
PROVIDE GUARD AT ENGINE SHAFT IWO E ESCAPE.
Condition: Unknown
Due 13 December 2001
Resolved 4 April 2002
System not recorded
Issued 29 November 2001 Resolved
VESSEL MUST MEET THE RAIL HEIGHT REQUIREMENTS AS SET FORTH IN "OLD" SUB "T"177.35. PRIOR TO RESOLVING NO PASSENGERS ARE PERMITTED ON STERN WHERE NO RAIL EXISTS.
Condition: Unknown
Due 29 January 2002
Resolved 4 April 2002
Unknown
Issued 30 August 2000 Resolved
VESSEL IS RESTRICTED TO NO MORE THAN 3 MILES FROM SHORE WITH PASSENGERSFOR HIRE UNTIL A 406 EPIRB IS INSTALLED TO THE SATISFACTORY OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 30 September 2000
Resolved 20 December 2000
Unknown
Issued 30 August 2000 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 30 September 2000
Resolved 20 December 2000
Unknown
Issued 27 October 1999 Resolved
Provide Navigation pubs.
Condition: Unknown
Due 27 November 1999
Resolved 11 May 2000
Unknown
Issued 27 October 1999 Resolved
Service fff pilot bottle, within 7 days.
Condition: Unknown
Due 3 November 1999
Resolved 11 May 2000
Unknown
Issued 27 October 1999 Resolved
Hardwire electrical bilge pumps.
Condition: Unknown
Due 27 November 1999
Resolved 11 May 2000
Unknown
Issued 27 October 1999 Resolved
Label and arrange air closures in engine room.
Condition: Unknown
Due 24 November 1999
Resolved 4 April 2000
Unknown
Issued 27 October 1999 Resolved
Replace worn life ring prior to takeing passengers.
Condition: Unknown
Due 24 November 1999
Resolved 5 January 2000
Navigation
Issued 11 October 1995 Resolved
PROVIDE UPDATED CHARTS AREAS FOR WHICH VESSEL IS CERTIFICATED TO OPERATE AND PROVIDE AN UPDATED NAVIGATION RULES BOOK.
Condition: Unknown
Due 11 October 1995
Resolved 11 October 1995
Unknown
Issued 11 October 1995 Resolved
PROVIDE PROOF OF ENROLLMENT IN A RANDOM DRUG TESTING PROGRAM.
Condition: Unknown
Due 11 October 1995
Resolved 11 October 1995

Casualty record · 1

28 April 2008Routine · role: Involved in a Marine Casualty · activity 3206053
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.