MAURY USCG vessel records Sign in
← All vessels

BAY SPIRIT

BAY SPIRIT is a 2001 passenger vessel (inspected). The Coast Guard has recorded 50 inspections since 2000, most recently in April 2026, along with 82 deficiencies and 2 casualty investigations between 2009 and 2017.

Records from 2000 to 2026. Most recent: inspection, 30 April 2026.

Built
2001
Last inspected
30 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDE9203
Flag
UNITED STATES
367414660
Maury page id
psix-23958

Inspections, by type

…with no type recorded6
Years with a record 24 calendar years (2000–2026)
The 50 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)63.3 ft × 23.8 ft × 8.6 ft
Registered tonnagegross 43 / net 35
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOOPER MARINE · ST PETERSBURG, FL, UNITED STATES · built 2001
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationTwin Hull
Hailing portHYANNIS, MA
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 5 August 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it43 - Simplified, Gross Ton
35 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDE9203MMSI 367414660 · active · compulsorily equipped · granted 30 March 2019, expires 12 June 2029
WDA4413MMSI 366809140 · expired · compulsorily equipped · granted 24 April 2001, cancelled 25 June 2011
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 50

30 April 2026 COI Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 8357332
15 April 2026 Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8350223
29 May 2025 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 8147231
4 June 2024 Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7929904
22 April 2024 Administrative Inspection · Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7889728
8 March 2024 Administrative Inspection
Administrative · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7876072
18 May 2023 Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7686743
24 January 2023 In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7626372
6 July 2022 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7492258
26 April 2022 Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7429263
17 May 2021 COI Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7198911
1 July 2020 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7005965
16 April 2020 Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 6939874
13 June 2019 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6706423
8 June 2018 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6431313
11 April 2018 Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6386572
20 July 2017 Damage Survey · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6223797
20 July 2017 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6315839
5 May 2017 Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6139846
12 May 2016 Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5875303
31 March 2016 Examination of Repairs · Drydock Exam
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 5856775
23 May 2014 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 4866546
18 March 2014 Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4818377
15 May 2012 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 4312345
26 March 2010 Drydock Exam
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 3703574
28 July 2009 Deadweight Survey
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 3557065
6 April 2009 DAPI Audit · Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3447023
20 October 2008 Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3347301
26 August 2008 Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3309175
11 April 2008 Plan Review "T" Boat · Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3181797
1 April 2008 Deficiency Check · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3176129
21 March 2007 Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2891833
8 September 2006 Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2772273
1 March 2006 COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2593098
22 July 2005 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2435961
20 July 2005 Deficiency Check · Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2433231
16 December 2004 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2256968
6 May 2004 Deficiency Check · Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2059483
2 October 2003 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1918608
19 February 2003 Deficiency Check · Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1717569
13 December 2002 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1727550
8 August 2002 Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1662400
6 August 2002 Type not recorded
No type recorded · Station St Petersburg · USCG Southeast District (CGD-SE) · Activity 1662898
9 February 2002 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1493010
22 January 2002 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1480840
22 August 2001 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1071656
2 May 2001 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1061865
4 April 2001 Initial Certification · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1460508
6 September 2000 Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1469636
1 February 2000 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 816411

Deficiency record · 82

01 - Certificates & Documentation › 012 - Crew Certificates › Record of employment
Issued 29 May 2025 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 29 May 2025
Resolved 23 June 2025
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 29 May 2025 Resolved
Each survival craft must be: (1) Secured to the vessel by a painter with a float-free link permanently attached to the vessel except that a float-free link is not required if the vessel operates only on waters not as deep as the length of the painter; (2) Stowed so that when the vessel sinks the survival craft floats free and, if inflatable, inflates automatically; Vessel has improper securing of the IBA. The "bowsing" line is not to be fashioned in any form to the vessel. The "Painter" shall be attached to the dedicated weak-link of the hydrostatic assembly. Corrected on the spot with attending USCG MI. 46CFR 180.130
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 29 May 2025
Resolved 29 May 2025
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 29 May 2025 Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. The life bouy's on the vessel were not marked with name. Corrected on the spot with attending USCG MI. 46CFR 185.604.b.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 29 May 2025
Resolved 29 May 2025
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 29 May 2025 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (1) Charts of large enough scale to make safe navigation possible; The vessel has paper charts and a digital chart plotter. Either item was last updated 2009. Vessel to provide updated charts or chart plotter card to the attending USCG MI within 14 days. 46CFR 184.420
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025
Resolved 23 June 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 May 2025 Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the waterlight around the body of the ring life buoy. One of the vessels ring life buoys has a waterlight attached by a corroded and non-functioning clip. Vessel to secure the waterlight securely around the body of the ring IAW regulations. Provide proper installation to the attending USCG MI within 14 days. 46CFR 180.70.d.2.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025
Resolved 23 June 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 January 2023 Resolved
Whenever machinery is installed after completion of the initial inspection for certification as replacement equipment, the owner shall conduct the tests and make the vessel ready for the inspections required by 46CFR176.402(d) to the satisfaction of the cognizant [name withheld] vessel main engine has been replaced, USCG marine inspectors must verify new installed machinery and any modifications if applicable, verify stability IAW current stability letter and perform sea trial.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2023
Resolved 5 May 2023
Resolution: Completed a satisfactory test of the DVTP and electrical review.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 6 July 2022 Resolved
Each vessel that operates on the high seas or beyond 3 miles from the coastline of the Great Lakes must have on board a FCC Type accepted Category 1, 406 MHz EPIRB. MI witnessed EPIRB battery without proper/valid expiration sticker. Owner/operator to provide proof of valid battery or replace prior to operating on the high seas. 46CFR180.64
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 12 July 2022
Resolution: Operator acquired new EPIRB battery rectifying deficiency.
Lifesaving › Visual Distress Signals (General) › Quantity
Issued 8 June 2018 Resolved
Update # of flares to distress signal equipment.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2018
Resolved 3 July 2018
Resolution: Flares have been updated.
Communications › Radio Communications › VHF Radiotelephone
Issued 8 June 2018 Resolved
Provide new radio Certificate Radio Cert.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2018
Resolved 3 July 2018
Resolution: Vessel received new cert.
Engineering › Diesel Engine (propulsion-reduction gear) › Pump, Positive Displacement
Issued 20 July 2017 Resolved
Water pump impeller worn, Prove proper operation of starboard engine prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 July 2017
Resolved 20 July 2017
Personnel › Certificates/Documents/Licenses › License, Operator
Issued 5 May 2017 Resolved
Provide current MMD
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 May 2017
Resolved 23 May 2017
Resolution: MMD has been provided
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 5 May 2017 Resolved
AVH07: Provide documentation for IBA being serviced. Install IBA prior to carrying max passengers.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 May 2017
Resolved 23 May 2017
Resolution: IBA has been serviced
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 5 May 2017 Resolved
AVH05: Life ring buoy markings are faded.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 May 2017
Resolved 23 May 2017
Resolution: Life buoys have been properly marked
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 5 May 2017 Resolved
AVH09: General house keeping priot to first voyage.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 May 2017
Resolved 23 May 2017
Resolution: Vessel has cleanded up passenger areas.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 May 2017 Resolved
AVH01: Update first aid kit
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 May 2017
Resolved 23 May 2017
Resolution: Medical kit has been updated.
Documentation › Logs/Records › Drug Test Records
Issued 5 May 2017 Resolved
AVH02: Update drug and alcohol program.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 May 2017
Resolved 23 May 2017
Resolution: DAPI has been corrected.
Engineering › Bilge Water Management System › Not Operational
Issued 5 May 2017 Resolved
AVH03: Bilge alarm is not working Repair or replace alarm.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 May 2017
Resolved 23 May 2017
Resolution: bilge alarm is working
Engineering › Bilge Water Management System › Not Operational
Issued 5 May 2017 Resolved
AVH04: Exposed wiring. Install proper wiring
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 May 2017
Resolved 23 May 2017
Resolution: Wires have been secured.
Lifesaving › Lifebuoys › Serviceable
Issued 5 May 2017 Resolved
AVH08: Repalce stbd life ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 May 2017
Resolved 23 May 2017
Resolution: ring buoy has been replaced.
Fire Fighting › Structural - A Class Divisions › Windows
Issued 16 May 2016 Resolved
Broken front window. Repair and replace window PTCP
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 May 2016
Resolution: Window has been replaced
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 May 2016 Resolved
Exposed wiring. Install wiring properly
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 19 May 2016
Resolution: All exposed wiring has been corrected.
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 May 2016 Resolved
Remove wing nuts on batteries.
Condition: Invalid
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 19 May 2016
Resolution: Wing nuts have been removed.
Lifesaving › Hand Flares › Quantity
Issued 16 May 2016 Resolved
Add 3 red flares to flare kit
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 May 2016
Resolution: Flares have been added.
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 16 May 2016 Resolved
Install a securing device holding the refrigerators
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 19 May 2016
Resolution: Refrigerator has been secured properly.
Navigation › Piloting/Steering › Marine Charts
Issued 12 May 2016 Resolved
Condition: Invalid
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 19 May 2016
Resolution: Vessel rep purchased new charts
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 12 May 2016 Resolved
Update first aid kit
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 19 May 2016
Resolution: First aid kit has been updated.
Electrical › Lighting (service) › Lighting Fixture
Issued 12 May 2016 Resolved
repair lighting fixture.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 19 May 2016
Resolution: Light fixture has been repaired.
Electrical › Electric Generation Source (service) › Generator
Issued 23 May 2014 Resolved
Prepare generator for inspection and prove proper operation to the satisfaction of the attending CG marine inspector.
Action required: 705 - Other - as specified
Due 23 June 2014
Resolved 27 June 2014
Resolution: Prepared generator for inspection and proved proper operation.
Documentation › Certificates/Documents › Stability Letter
Issued 18 March 2014 Resolved
Vessel is to conduct Credit Dry Dock and ISE prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2014
Resolution: Vessel completed Dry Dock and ISE.
Communications › Radio Communications › EPIRB
Issued 15 May 2012 Resolved
Hydrostat expires June 2012, replace hydro
Action required: 705 - Other - as specified
Due 15 June 2012
Resolved 30 May 2012
Engineering › Engine Controls (Electric/Electronic) › Actuator
Issued 15 May 2012 Resolved
Start solenoid not working, replace solenoid
Action required: 705 - Other - as specified
Due 18 May 2012
Resolved 30 May 2012
Resolution: Called by owner, solenoid fixed 18may, due to inspection load took masters statement for repair
Navigation › Piloting/Steering › Coast Guard Light List
Issued 15 May 2012 Resolved
Lightlist & coast pilot out of date 2 yrs, renew
Due 15 June 2012
Resolved 30 May 2012
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 15 May 2012 Resolved
Expired meds in first aid kit, renew
Due 15 June 2012
Resolved 30 May 2012
Lifesaving › Buoyant Apparatus › Approval
Issued 15 May 2012 Resolved
Call CG for inspection of new installation
Due 30 May 2012
Resolved 30 May 2012
Resolution: New 30 man IBA installed
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 15 May 2012 Resolved
All round white light loose socket, replace light
Due 18 May 2012
Resolved 30 May 2012
Resolution: Received phone call from Master stating light replaced, due to inspection load took Master''s statement for repair.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 6 April 2009 Resolved
REPLACE BULB IN ANCHOR LIGHT.
Due 13 April 2009
Resolved 30 April 2009
Lifesaving › Hand Flares › Quantity
Issued 6 April 2009 Resolved
PROVIDE 4 RED HAND FLARES.
Due 13 April 2009
Resolved 7 April 2009
Communications › Radio Communications › EPIRB
Issued 6 April 2009 Resolved
REPLACE HYDROSTATIC RELEASE FOR EPIRB. VSL IS LIMITED TO INSIDE THE LINE OF DEMARCATION UNTIL NEW HYDROSTATIC RELEASE IS INSTALLED.
Action required: 705 - Other - as specified
Resolved 30 April 2009
Engineering › Sea-water System (primary cooling) › Piping
Issued 6 April 2009 Resolved
MOUNT RAW WATER STRAINER FOR PORT PROPULSION ENGINE.
Due 13 April 2009
Resolved 7 April 2009
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 6 April 2009 Resolved
REMOVE OIL RESIDUE FROM PORT ENGINE ROOM.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 April 2009
Engineering › Generator (propulsion-electric) › Battery
Issued 6 April 2009 Resolved
REPAIR/REPLACE BATTERY FOR FOR PORT PROPULSION ENGINE.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 April 2009
Engineering › Fuel Oil Service System › Valve
Issued 6 April 2009 Resolved
REPLACE REMOTE FUEL SHUTOFF ENCLOSURE ON THE PORT SIDE.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 April 2009
Fire Fighting › Ventilation Systems › Ducts
Issued 6 April 2009 Resolved
REPLACE VELCROW ATTACHEMENTS FOR PORT ENGINE ROOM VENTILATIONS CLOSURE.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 April 2009
Engineering › Bilge Water Management System › Pump
Issued 6 April 2009 Resolved
REPAIR/REPLACE MIDSHIPS BILGE PUMPS AND THE HIGH LEVEL ALARM IN THE PORT ENGINE ROOM.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 April 2009
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 6 April 2009 Resolved
INSTALL INTERLOCK ON THE GENERATOR CIRCUIT BREAKER.
Due 13 April 2009
Resolved 30 April 2009
Communications › Radio Communications › EPIRB
Issued 11 April 2008 Resolved
REPLACE EPIRB BATTERY. VESSEL MAY NOT SAIL PAST THE BOUNDRY LINE UNTIL THE BATTERY IS REPLACED.
Action required: 705 - Other - as specified
Resolved 4 November 2008
Resolution: 2OCT08: Rcv''d fax from owner rep that the EPIRB has been repaired and returned to the vessel. 04NOV08: Visited vsl while attending another vessel inspection and confirmed the EPIRB was mounted on the vessel.
Electrical › Electrical Distribution System (service) › Cable
Issued 11 April 2008 Resolved
MAKE PROPER ELECTRICAL CONNECTION TO FWD BILGE PUMP STBD SIDE.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 April 2008
Resolution: PROPER CONNECTION WAS MADE.
Electrical › Electrical Distribution System (service) › Cable
Issued 11 April 2008 Resolved
REMOVE OR MAKE PROPER ELECTRICAL CONNECTION FOR EXHAUST FAN STBD SIDE IN THE MSD SPACE.
Due 18 April 2008
Resolved 18 April 2008
Resolution: PROPER ELECTRICAL CONNECTIONS WERE MADE.
Electrical › Electrical Distribution System (service) › Cable
Issued 11 April 2008 Resolved
HARD WIRE GENERATORS ELECTRICAL R/W PUMP AND PROVIDE SPECIFICATION SHEET FOR PUMP AND MOTOR. ALSO PROVIDE A LINE DRAWING OF THE SYSTEM AS INSTALLED.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 April 2008
Resolution: PUMP WAS HARD WIRED TO THE DISTRIBUTION PANEL.
Engineering › Sea-water System (primary cooling) › Piping
Issued 11 April 2008 Resolved
DOUBLE CLAMP ALL R/W HOSES AND EXHAUST HOSES PORT AND STBD SIDE.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 April 2008
Resolution: HOSES WERE DOUBLE CLAMPED.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 11 April 2008 Resolved
CLEAN OIL RESIDUE IN PORT ENG ROOM.
Due 18 April 2008
Resolved 18 April 2008
Resolution: OIL RESIDUE WAS REMOVED. SURFACE IS STAINED BUT THE OILY RESIDUE WAS GONE.
Communications › Alarms/Indicators › Bilge Alarm
Issued 11 April 2008 Resolved
REPAIR/REPLACE STBD SIDE ENG ROOM HIGH LEVEL ALARM.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 April 2008
Resolution: HIGH LEVEL ALARM WAS REPAIRED.
Engineering › Sea-water System (primary cooling) › Piping
Issued 11 April 2008 Resolved
REPLACE BOTH R/WSUPPLY HOSES FOR BOTH MAIN ENGINES.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 April 2008
Resolution: R/W HOSES WERE REPLACED.
Engineering › Fuel Oil Service System › Hose
Issued 11 April 2008 Resolved
REPLACE STBD MAIN ENGINE F/O SUPPLY HOSE.
Due 18 April 2008
Resolved 11 April 2008
Resolution: HOSE WAS REPLACED.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 1 April 2008 Resolved
Repair and prove proper operation of fixed extinguishing system for both main engines NLT 04APR08. You are authorized to operate inside Tampa Bay from Ybor Channel to the Alafia River while the fixed extinguishing systems are being repaired. You are required to post a fire watch for each engine room with two additional serviceable B-II fire extinguishers provided for each engine room at all time
Due 4 April 2008
Resolved 11 April 2008
Resolution: Fixed fire fighting sys was repaired.
Communications › Radio Communications › EPIRB
Issued 21 March 2007 Resolved
Prior to operating on your Limited Coastwise Route, proved your EPIRB registration.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 March 2007
Resolved 10 May 2007
Resolution: Rcvd documentation showing EPRIB registration was updated.
Communications › Radio Communications › EPIRB
Issued 21 March 2007 Resolved
Prior to operating on your Limited Coastwise Route, have the cracks in your EPIRB antenna repaired by a third qualified party.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 March 2007
Resolved 9 May 2007
Resolution: Antenna was replaced with a new one.
Lifesaving › Hand Flares › Expired
Issued 21 March 2007 Resolved
Prior to operating on your Limited Coastwise Route, provide 6 day/knight hand held distress signals. POC has six that are all ready expired and 6 that are not expired. He needs 12 to operate on his LC route.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 March 2007
Resolved 9 May 2007
Resolution: Expired flares were replaced.
Communications › Radio Communications › EPIRB
Issued 1 March 2006 Resolved
Prior to operating on your LIMITED COASTWISE ROUTE, provide your EPIRB and proof of registration. POC sent EPIRB to the shop for a new battery and hasn't received it back yet. Vessel has not operated under his LC route in a year.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2006
Resolved 13 September 2006
Resolution: INSPECTED EPIRB DURING DRY DOCK EXAMINATION.
Lifesaving › Lifebuoys › Serviceable
Issued 20 July 2005 Resolved
INSTALL RETROREFECTIVE MATERIAL ON LIFERING PRIOR TO OPERATION AT NIGHT.
Due 20 August 2005
Resolved 20 August 2005
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 20 July 2005 Resolved
REPAIR GENERATOR SHUTDOWN INTEGRAL WITH PORT FIXED FIREFIGHTING SYSTEM.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 July 2005
Resolution: WITNESSED/[name withheld].
Lifesaving › Hand Flares › Expired
Issued 20 July 2005 Resolved
PROVIDE 6 DAY/NIGHT HAND HELD FLARES.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 July 2005
Resolution: WITNESSED/[name withheld]
Engineering › Bilge Water Management System › Not Operational
Issued 20 July 2005 Resolved
REPAIR CENTER/STBD HIGH LEVEL ALARM.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 July 2005
Resolution: WITNESSED/[name withheld]
Engineering › Bilge Water Management System › Not Installed
Issued 20 July 2005 Resolved
LABEL INDIVIDUAL BILGE PUMP/HIGH LEVEL ALARMS.
Due 20 August 2005
Resolved 21 July 2005
Resolution: WITNESSED/[name withheld]
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 20 July 2005 Resolved
UPDATE EMERGENCY PROCEDURES UNIQUE TO VESSEL OPERATIONS.
Due 20 August 2005
Resolved 21 August 2005
Documentation › Certificates/Documents › Certificate of Inspection
Issued 20 July 2005 Resolved
Failure to make vessel available for annual inspection within three months before or after each anniversary date of issuance of the COI
Due 20 July 2005
Resolved 20 July 2005
Resolution: Marine Inspector attended vessel to conduct annual inspection.
Documentation › Markings/Placards › Hull Identification Number (HIN)
Issued 6 May 2004 Resolved
Vessel name missing from Starboard side..
Condition: Improper/Lack of Maintenance
Due 6 June 2004
Resolved 14 August 2004
Electrical › Lighting (service) › Lighting Fixture
Issued 6 May 2004 Resolved
light cover missing from starboard side engine room compartment.
Due 6 June 2004
Resolved 14 August 2004
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 6 May 2004 Resolved
provide copy of annual MIS report.
Due 6 June 2004
Resolved 7 May 2004
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 19 February 2003 Resolved
Current Enrollment letter not available for all employees
Due 26 February 2003
Resolved 26 February 2003
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 19 February 2003 Resolved
DAPI EAP program information not available
Due 26 February 2003
Resolved 26 February 2003
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 19 February 2003 Resolved
MIS Submission information not available.
Due 26 February 2003
Resolved 26 February 2003
Fire Fighting › Fixed Halon Fire Extinguishing System › Tanks
Issued 19 February 2003 Resolved
No annual inspection on fixed firefighting system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 February 2003
Resolved 20 February 2003
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 19 February 2003 Resolved
No annual service documentation.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 February 2003
Resolved 20 February 2003
Lifesaving
Issued 4 April 2001 Resolved
Label storage containers with extra children's lifejackets.
Condition: Unknown
Due 4 April 2001
Resolved 4 April 2001
Lifesaving
Issued 4 April 2001 Resolved
Obtain proper waterlight for ring life buoy. Must be attached with corrosion resistant clip and 3-6 feet of line.
Condition: Unknown
Due 4 April 2001
Resolved 4 April 2001
Documentation
Issued 4 April 2001 Resolved
obtain permanent FCC safety certificate.
Condition: Unknown
Due 4 April 2001
Resolved 4 April 2001
Construction/Loadline
Issued 4 April 2001 Resolved
Prove proper operation of port and starboard midship bilge pumps.
Condition: Unknown
Due 4 April 2001
Resolved 4 April 2001
Lifesaving
Issued 4 April 2001 Resolved
Install UL approved smoke detectors in fuel tank spaces.
Condition: Unknown
Due 4 April 2001
Resolved 4 April 2001
Lifesaving
Issued 4 April 2001 Resolved
Properly secure netting on railing.
Condition: Unknown
Due 4 April 2001
Resolved 4 April 2001
Lifesaving
Issued 4 April 2001 Resolved
Install wire/railing at ladder accesses to water in way of stern.
Condition: Unknown
Due 4 April 2001
Resolved 4 April 2001
Lifesaving
Issued 4 April 2001 Resolved
Install netting on railing across transom accessible to passengers.
Condition: Unknown
Due 4 April 2001
Resolved 4 April 2001

Casualty record · 2

19 September 2009Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3632228
20 July 2017Routine · role: Involved in a Marine Casualty · activity 6315839
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.