Records from 1984 to 1998. Most recent: inspection, 5 January 1998.
A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Construction/Loadline › Markings › Load Line Mark
Issued 5 January 1998
Resolved
PAINT DECK LINE IN CONTRASTING COLOR TO HULL.
Condition: Unknown
Due 9 February 1998
Resolved 5 October 2004
Resolution: 05OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Construction/Loadline › Structures › Air Pipe
Issued 5 January 1998
Resolved
REPAIR/REPLACE VENT & FLAME SCREEN FOR FUEL OIL SERVICE TANK.
Condition: Unknown
Due 9 February 1998
Resolved 5 October 2004
Resolution: 05OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Construction/Loadline › Structures › Air Pipe
Issued 5 January 1998
Resolved
REPAIR ALL VENT CLOSURES FOR # 2 AND #3 DEFROSTING ROOMS OUTSIDE WEATHER DECK. SOME CLOSURE HAVE STUDS BROKEN, FROZEN OR HAVE MISSING WING NUTS.
Condition: Unknown
Due 9 February 1998
Resolved 5 October 2004
Resolution: 05OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Fire Fighting › Fire Main › Condition
Issued 5 January 1998
Resolved
REPLACE THE FIRE CONTROL PLAN.
Condition: Unknown
Due 9 February 1998
Resolved 5 October 2004
Resolution: 05OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Fire Fighting › International Shore Connection › Bolts
Issued 5 January 1998
Resolved
PROVIDE WEATHERTIGHT CONTAINER FOR THE FIRE CONTROL PLAN.
Condition: Unknown
Due 9 February 1998
Resolved 5 October 2004
Resolution: 05OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Lifesaving
Issued 5 January 1998
Resolved
INSTALL WEAK LING ON LIFERAFT #3 PRIOR TO SAIL FROM THE PORT.
Condition: Unknown
Due 9 January 1998
Resolved 12 January 1998
Electrical
Issued 4 December 1995
Resolved
THERE ARE NO EXPLOSION PROOF LIGHT FIXTURES FOR LIGHTS ABOVE THE #2 AND #3 GENERATOR. _x001C_ SOLAS 74 CH-II 2 PART B REG 27(a)(v)
Condition: Unknown
Due 9 January 1998
Resolved 9 January 1998
Engineering
Issued 4 December 1995
Resolved
diesel oil tank #11 vent containment is wasted.
Condition: Unknown
Due 9 January 1998
Resolved 9 January 1998
Fire Fighting
Issued 4 December 1995
Resolved
THE VESSEL WAS MISSING A FIRE HOSE IN THE ENGINE ROOM._x001C_ SOLAS 74 CH II-2 REG 5(f).
Condition: Unknown
Due 4 December 1995
Resolved 11 December 1995
Engineering
Issued 10 October 1984
Resolved
OPERATING A VESSEL THAT DID NOT HAVE PROPER FUEL OIL/BULK LUBE OIL DISCHARGE CONTAINMENT. A VIOLATION OF 33 CFR 155.320.
Condition: Unknown
Due 12 December 1995
Resolved 12 December 1995