MAURY USCG vessel records Sign in
← All vessels

S VENUS

S VENUS is a 1984 freight ship. The Coast Guard has recorded 24 inspections since 1984, most recently in December 2005, along with 11 deficiencies and 1 operational control.

Records from 1984 to 2005. Most recent: inspection, 12 December 2005.

Built
1984
Last inspected
12 December 2005
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8323111 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
239666
Flag
PANAMA
—
Maury page id
psix-239666

Inspections, by type

…with no type recorded19
Years with a record 17 calendar years (1984–2005)
The 24 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 21 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it22221 - Regulatory (Subpart C or D), Gross Ton
36241 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 24

12 December 2005 Type not recorded
No type recorded · Maritime Safety & Security Team San Francisco (91105) · Activity 2550302
11 December 2005 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2549621
6 September 2005 Random ISPS/MTSA/PSC
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2485238
19 July 2005 Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2431923
22 January 2005 Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2279083
6 January 2003 Annual Inspection · Ballast Water Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1725516
19 March 2002 Examination of Repairs
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1494737
2 December 2001 Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 295509
27 March 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 288567
21 September 2000 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 282396
1 November 1999 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 434152
10 October 1999 Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 433625
3 December 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 423308
16 September 1997 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 407983
19 October 1996 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 396470
5 February 1992 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 348594
3 February 1991 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 341685
10 September 1989 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 332519
12 July 1988 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 324382
9 June 1987 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 316732
2 July 1986 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 497791
8 May 1986 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 308642
29 July 1985 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 481016
11 November 1984 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 298952

Deficiency record · 11

Navigation › Collision/Grounding Avoidance › Radar
Issued 11 December 2005 Resolved
Vessel's 10 cm radar is inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 December 2005
Resolution: Radar was repaired.
Electrical › Electric Generation Source (service)
Issued 19 March 2002 Resolved
Make permanent repairs to the #2 SSG to the satisfaction of class. LEGACY COMPONENT DESC: Generator
Action required: 15 - Rectify deficiencies by next port
Resolved 6 January 2003
Resolution: SSG #2 was repaired to the satisfaction of the attending Class surveyor and in proper working order.
Electrical
Issued 27 March 2001 Resolved
EXHAUST MANIFOLD LEAK ON NO.2 GENERATOR.
Condition: Unknown
Due 31 March 2001
Resolved 5 April 2001
Engineering
Issued 27 March 2001 Resolved
BOTH L/O PURIFIERS AND INSULATION FOULED WITH EXCESSIVE OIL BUILD-UP.
Condition: Unknown
Due 4 April 2001
Resolved 5 April 2001
Electrical
Issued 27 March 2001 Resolved
EXCESSIVE FUEL LEAKAGE ON NO.2 GENERATOR FUEL INJECTION PUMPS 2 & 3.
Condition: Unknown
Due 4 April 2001
Resolved 5 April 2001
Engineering
Issued 27 March 2001 Resolved
EXCESSIVE LEAKAGE FROM SEALS ON NO.1 & NO.2 S/W COOLING PUMPS.
Condition: Unknown
Due 4 April 2001
Resolved 5 April 2001
Engineering
Issued 27 March 2001 Resolved
EXCESSIVE LEAKAGE FROM NO.1 & NO.2 L/O PUMP SEALS.
Condition: Unknown
Due 4 April 2001
Resolved 5 April 2001
Engineering
Issued 27 March 2001 Resolved
MAKE PERMANENT REPAIRS TO LEAKING TEMP PATCH ON L/O PURIFIER STEAM LINE.
Condition: Unknown
Due 4 April 2001
Resolved 5 April 2001
Electrical
Issued 1 November 1999 Resolved
REPAIR OIL LEAK ON #1 GENERATOR. SOLAS 74 (amended) 1/11
Condition: Unknown
Due 25 September 2000
Resolved 25 September 2000
Fire Fighting
Issued 1 November 1999 Resolved
REPAIR WATER, SMOKE, AND OIL LEAK IN WAY OF EMERGENCY FIRE PUMP. SOLAS 74 (amended) 1/11
Condition: Unknown
Due 25 September 2000
Resolved 25 September 2000
Navigation
Issued 11 November 1984 Resolved
NOS CHARTS 18720, 18751; PUBLICATION LIGHT LIST, DATED 1984, WERE NOT SUFFICIENTLY CORRECTED TO DATE.
Condition: Unknown
Due 11 November 1984
Resolved 11 November 1984

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.