Records from 2016 to 2022. Most recent: inspection, 8 December 2022.
Inspection history · 8
8 December 2022
Examination of Repairs
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7606383
18 August 2020
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7036193
15 April 2020
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6949577
10 October 2019
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6832963
17 May 2018
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6416060
12 April 2018
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6390461
19 May 2017
Deficiency Check · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6149932
17 May 2016
Deficiency Check · Hull Examination · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5880201
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 15 April 2020
No resolution recorded
Repairs or alterations to the hull, machinery, or
equipment that affect the safety of the vessel must not
be made without the approval of the cognizant OCMI.
Vessel has damage to the port side hull near the
transom approximately 6” above the water line.
Operator must submit repair proposal, and conduct
approved repairs to the satisfaction of the attending
Marine Inspector, prior to carrying passengers.
Action required: 705 - Other - as specified
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 10 October 2019
Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. Vessel does not have any portable lights on board.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 October 2019
Resolved 8 November 2019
Resolution: Operator provided portable lights for the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 10 October 2019
Resolved
Portable watertight containers for distress flares and smoke signals shall be of a bright color, and containers shall be clearly marked in legible contrasting letters at least 12.7 millimeters (0.5 inches) high: “DISTRESS SIGNALS”. Distress flares on vessel were not stored in watertight container.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 October 2019
Resolved 8 November 2019
Resolution: Distress flares were stored in a watertight container onboard the vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 October 2019
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. First Aid kit was not IAW 160.042 or equivalent.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 October 2019
Resolved 8 November 2019
Resolution: Operator provided approved first aid kit for vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 October 2019
Resolved
Each floating waterlight must be approved in accordance with §161.010 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.110. Vessel’s floating waterlight contained a battery not compatible with the manufacurer's recommendations or IAW subchapter Q.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 October 2019
Resolved 8 November 2019
Resolution: Operator provided correct battery for floating weaterlight
Engineering › Lubricating Oil Service System › Cooler
Issued 17 May 2018
Resolved
Repair/replace oil cooler for MDE.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2018
Resolved 6 June 2018
Resolution: Oil cooler replaced.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 17 May 2018
Resolved
Provide up-to-date charts and pubs for vessel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2018
Resolved 6 June 2018
Resolution: Up-to-date charts and pubs provided for vessel.
Engineering › Bilge Water Management System › Not Installed
Issued 19 May 2017
Resolved
Prove proper operation of engine room bilge high level alarm.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 May 2017
Resolved 19 May 2017
Resolution: Installed bilge high level alarm.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 19 May 2017
Resolved
Provide 02 adult life jackets. Passengers reduced to 18.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 May 2017
Resolved 30 May 2017
Resolution: 02 additional life jackets provided.
Lifesaving › Lifejacket/PFD (Type III) › Storage
Issued 17 May 2016
Resolved
Labe life jacket stowage by 14JUL16; 46CFR180.78
Action required: 705 - Other - as specified
Due 14 July 2016
Resolved 19 July 2016
Resolution: jacket stowage labeled
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 17 May 2016
Resolved
Provide servicing report and demonstrate operation of PSI switch shut down by 14JUL16 ; 46CFR181.420.
Action required: 705 - Other - as specified
Due 14 July 2016
Resolved 19 July 2016
Resolution: servicing report for new fireboy and witnessed sat start and stop of engine from engine and operators station
Lifesaving › Lifejacket/PFD (Type III) › Retroreflective Material
Issued 17 May 2016
Resolved
New retro on 5 life jackets by 14JUL16; 46CFR180.75.
Action required: 705 - Other - as specified
Due 14 July 2016
Resolved 19 July 2016
Resolution: 5 life jackets had retro replaced,
Navigation › Piloting/Steering › Marine Charts
Issued 17 May 2016
Resolved
Provide charts for operating area by 14JUL16; 46CFR184.420.
Action required: 705 - Other - as specified
Due 14 July 2016
Resolved 19 July 2016
Resolution: new NOAA chart was procured and posted in dispatchers shack,
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 17 May 2016
Resolved
Have onboard new first aid kit by 14JUL16; 46CFR184.710.
Action required: 705 - Other - as specified
Due 14 July 2016
Resolved 19 July 2016
Resolution: new first aid kit purchased,
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 17 May 2016
Resolved
Have onboard new/working flashlight by 14JUL16; 46CFR183.430
Action required: 705 - Other - as specified
Due 14 July 2016
Resolved 19 July 2016
Resolution: new first aid kit purchased, and working.