Records from 1984 to 2012. Most recent: inspection, 24 May 2012.
Inspection history · 40
24 May 2012
Ballast Water Examination · ISPS I Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4314988
23 May 2012
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4315063
23 May 2012
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4319562
2 February 2010
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3673956
12 September 2008
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3323543
11 September 2008
Random ISPS/MTSA/PSC
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3322749
13 March 2008
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3163672
12 March 2008
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3163345
4 September 2007
PII Safety Exam · Ballast Water Examination · MARPOL Annex I Examination · ISPS II Exam · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3037512
21 April 2007
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2912212
13 October 2005
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2513695
18 February 2005
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2295419
6 October 2004
NPV Safety Exam · ISPS II Exam
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2215125
5 October 2004
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2214489
17 November 2003
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1948883
11 March 2002
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1492817
25 April 2001
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 289524
25 September 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 282495
28 December 1999
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 436014
6 January 1999
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 424190
13 June 1998
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 416964
8 June 1996
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 392042
7 February 1996
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 646508
3 February 1996
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 387573
10 February 1995
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 375195
20 November 1994
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1374168
29 January 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 106568
3 January 1994
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 363575
9 April 1993
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 496519
3 September 1992
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 353037
18 June 1992
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 518135
31 January 1992
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 650091
30 January 1992
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 471661
9 May 1991
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 343487
10 May 1990
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 337017
29 February 1988
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 321598
26 January 1988
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 320934
24 November 1986
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 516836
2 April 1986
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 307895
14 November 1984
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 298815
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 24 May 2012
No resolution recorded
9900 - Other (not clearly hazardous) - Crew could not provide documentation attesting to the pipe being hydrostatically tested to 1.5 times the MAWP. Provide documentation attesting to a proper test prior to bunkering in the U.S. - 33 CFR 156.170.
Action required: 705 - Other - as specified
Due 24 May 2012 — due date passed with no resolution recorded
Operations/Management › EPA Vessel General Permit (VGP) › 4.1.1-Routine Visual Inspections
Issued 24 May 2012
Resolved
9900 - Other (not cleary hazardous) - Vessel's master could not produce documentation that the visual inspections have been conducted required under Vessel's General Permit. - 33 U.S.C. 1251 and VGP Part 4.
Action required: 705 - Other - as specified
Due 24 May 2012
Resolved 24 May 2012
Resolution: PSCO advised the master that they must complete visual inspections at least once per week or per voyage, whichever is more frequent; unless they are engaged in multiple voyages per day, in which case a daily.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 11 September 2008
No resolution recorded
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Resolution: 12Sept08: Agent provided Master with photo –copies of Liberian endorsements for C/O & 4/E.
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 11 September 2008
Resolved
Vessel fire fighting capability in question as multiple portable extinguishers not ready for immediate use. PSCOs noted approx 15 extinguishers that appeared to be smaller than required (per Fire Control Plan or Safety Equipment Cert attachment – dry powder 6kg req’d & 4.5 on scene; CO2 6.8kg req’d & 5kg on scene) and/or severely corroded. See narritive: 0720
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 September 2008
Resolution: See Attached Class report from NKK "PUSAN REEFER"
Fire Fighting › Fire Hoses › Connections
Issued 11 September 2008
Resolved
On all deck fire hoses, nozzles affixed with threaded hose clamps – some severely corroded
Action required: 705 - Other - as specified
Due 18 September 2008
Resolved 15 September 2008
Resolution: See Attached Class report
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 11 September 2008
Resolved
Fire Control Plan is stamped approved by NKK as of 2002; previous 3/O apparently made changes in 2003. One change appears to have reduced the required capacity of the semi-portable (SOLAS 74 amend / II-2 / 52 requires semi portable no less than 45 liters). Based on above def’s, Class to attest to accuracy of Fire Control Plan & presence/serviceability of all required equipment prior to departure
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 September 2008
Resolution: See Attached Class report
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 4 September 2007
Resolved
The Oily Water Separator oil content meter was not operating and the PSCO was unable to test 15ppm alarm.
Action required: 705 - Other - as specified
Due 11 September 2007
Resolved 10 September 2007
Resolution: Received class report from NKK satisfying requirement. The report stated that the OWS content meter was renewed and tested with satisfactory results.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Turbocharger
Issued 4 September 2007
Resolved
The No.2 ship service generator has a temporary patch on the fresh water cooling line for the turbocharger that is leaking.
Action required: 705 - Other - as specified
Due 11 September 2007
Resolved 10 September 2007
Resolution: Received class report from NKK satisfying requirement. The report stated that the temporary patch was replaced with a new section of piping.
Electrical
Issued 25 April 2001
Resolved
PRIOR TO 25MAY01 INSTALL OR PROVIDE FLAG STATE WAIVER FOR ALL LIGHTS IN THEENGINE AND STEERING GEAR ROOMS TO HAVE OR NOT HAVE ANY PROTECTIVE COVERINGS.
Condition: Unknown
Due 25 May 2001
Resolved 10 March 2002
Accommodation/Occupational Safety
Issued 25 April 2001
Resolved
PRIOR TO 25MAY01 REMOVE OR MAKE BRACKET FOR LOOSE BARRELS IN STEERING GEAR ROOM.
Condition: Unknown
Due 25 May 2001
Resolved 10 March 2002
Fire Fighting
Issued 25 September 2000
Resolved
EMERGENCY FIRE PUMP CANNOT SUPPLY ADEQUATE WATER PRESSURE IAW SOLAS 74/78 II-2/21.
Condition: Unknown
Due 27 September 2000
Resolved 27 September 2000
Lifesaving
Issued 28 December 1999
Resolved
DURING ANNUAL FREIGHT EXAM 15 10,000KJ RATIONS IN PORT LIFEBOAT AND 14 10,000KJ RATIONS IN STARBOARD LIFEBOAT WERE FOUND WITH VACUUM SEALS BROKEN A VIOLATION OF SOLAS 74/78 CHAPTER III REG 41/8.12. CORRECT PRIOR TO VESSELDEPARTURE.
Condition: Unknown
Due 30 December 1999
Resolved 6 January 2000
Lifesaving
Issued 13 June 1998
Resolved
THE VESSEL'S PORT AND STARBOARD LIFEBOATS EACH HAD A SEAT THAT WAS WASTED. THIS IS REQUIRED TO BE CORRECTED PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 7 January 1999
Resolved 7 January 1999
Accommodation/Occupational Safety
Issued 3 February 1996
Resolved
THE M.S.D. WAS INOPERABLE AS A TYPE TWO, THE VESSEL WILL USED THE TYPE TWO AS A TYPE THREE. THE VESSEL WILL REPAIR THE TYPE TWO PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 12 June 1996
Resolved 12 June 1996
Construction/Loadline
Issued 3 February 1996
Resolved
THE OIL WATER SEPARATORS ALARM AND SENSOR WERE INOPERABLE. THE VESSEL WAS EQUIPPED WITH AN OPERABLE INCINERTOR AND WAS ALLOWED UNTIL NEXT U.S. PORT TO MAKE PERMENENT REPAIRS TO THE O.W.S.
Condition: Unknown
Due 12 June 1996
Resolved 12 June 1996
Navigation
Issued 3 September 1992
Resolved
Vessels N.O.S. charts 18749 and 18751 were not corrected to date.
Condition: Unknown
Due 8 September 1992
Resolved 8 September 1992
Navigation
Issued 3 September 1992
Resolved
Vessel did not have a copy of the inland navigation rules onboard.
Condition: Unknown
Due 8 September 1992
Resolved 8 September 1992
Navigation
Issued 10 May 1990
Resolved
CHARTS, COAST PILOT, AND LIGHT LIST NOT CORRECTED TO DATE AS REQUIRED BY 33CFR164.33
Condition: Unknown
Due 10 May 1990
Resolved 10 May 1990
Navigation
Issued 26 January 1988
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 26 January 1988
Resolved 26 January 1988
Documentation
Issued 26 January 1988
Resolved
A VIO OF 33CFR155.750 IN THAT THE OTP REQ BY 33CFR155.720 AND FURTHER DESCRIBED BY REF TO 33CFR154.310 WERE INCOMPLETE IN THAT THEY DID NOT CONTAIN PROCEDURES FOR OPERATING THE EMERGENCY SHUTDOWN AND TOPPING OFF TANKS.
Condition: Unknown
Due 26 January 1988
Resolved 26 January 1988