KOBE EXPRESS is a 1997 freight ship. The Coast Guard has recorded 20 inspections since 2016, most recently in January 2026, along with 4 deficiencies and 2 operational controls.
Records from 2016 to 2026. Most recent: operational control imposed, 21 January 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it89129 - Displacement, Metric Ton 67631 - Dead Weight, Metric Ton 53523 - Convention (Subpart B), Gross Ton 32908 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 20
21 January 2026Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8299178
21 January 2026In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8299314
17 January 2026In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8297697
2 December 2025Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8276686
10 October 2025Administrative Inspection · In-Service Inspection
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 4 January 2025Resolved
The Condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea with out danger to the ship or persons on board.
PSCO Observed a temporary repair to a hole on the topside of FOT(2s). Condition of Class issued requiring permanent repairs by 03APR2025.
74SOLAS(04) 1/11a
705c
Action required: 705 - Other - as specified
Due 3 April 2025
Resolved 22 February 2025
Resolution: Received report from DNV attesting to permanent repairs.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 3 June 2016Resolved
0611 - The normal equipment of every life boat shall consist of a food ration totaling not less than 10,000 kj for each person; these rations shall be airtight. Vessel had 23 out of 32 rations that were not airtight. SOLAS 97 III/38.5.1.18 17c
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 3 June 2016
Resolved 3 June 2016
Resolution: Received, reviewed and proper documentation from Master stating the deficiency was rectified. 25 rations ordered and shipped to vessel.
0950 - The condition of the ship and its equipment shall be maintained. PSCO observed the emergency generator hertz meter fluctuating and governor arm hunting during testing. 74 SOLAS (am) I/11 a 50 Priovide techinican report
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 July 2016
Resolved 25 June 2016
Resolution: PSC NOLA recieved a Class Survey statement from DNV-GL satisfying the requirement.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 3 June 2016Resolved
1720 - Each hose or piping system must be tested at least 1.5 times the maximum allowable working pressure. Vessel was unable to provide proof of liquid pressure testing on bunker lines. Prior to bunkering in U.S. waters. 33 CFR 156.170 c
Condition: Placed in Improper Service
Action required: 703 - Prior to bunkering operations
Due 3 June 2016
Resolved 10 June 2016
Resolution: PSC NOLA received proper documentation from the vessel satisfying the requirement.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.