Records from 1985 to 1993. Most recent: inspection, 19 February 1993.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 10
19 February 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1145580
11 September 1989
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 893179
7 December 1988
Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1038351
17 February 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1039295
6 January 1988
Certificate of Compliance
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1015479
16 March 1987
Certificate of Compliance
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1028761
17 July 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1301828
29 May 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1304180
16 April 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 990130
3 May 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1290877
Documentation
Issued 7 December 1988
Resolved
PROVIDE AN UPDATED ARRANGEMENT DRAWING REFLECTING PRODUCTION EQUIPMENT PRESENTLY INSTALLED.
Condition: Unknown
Due 31 March 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 7 December 1988
Resolved
PROVIDE AN UPDATED OPERATING MANUAL REFLECTING VESSEL'S PRESENT ROLE AS A PRODUCTION PLATFORM, TO INCLUDE EMERGENCY PROCEDURES RELATING TO PRODUCTION.
Condition: Unknown
Due 31 March 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 7 December 1988
Resolved
INSTALL APPROPRIATE 100 PSI PRESSURE RELIEF VALVES ON BOTH POTABLE WATER TANKS OR MAKE AVAILABLE FOR INTERNAL EXAMINATION OR HYDROSTATIC TEST.
Condition: Unknown
Due 7 December 1988
Resolved 7 December 1988
Lifesaving
Issued 7 December 1988
Resolved
CONDUCT A BOAT DRILL INCLUDING OPERATION OF BOTH BOATS IN THE WATER AND OPERATION OF THEIR SPRINKLER SYSTEMS. PROVIDE A COPY OF THE LOG ENTRY DOCUMENTING THIS DRILL.
Condition: Unknown
Due 7 December 1988
Resolved 7 December 1988
Engineering
Issued 7 December 1988
Resolved
REPAIR OR REPLACE WASTED FUEL TANK VENT FLAME SCREENS.
Condition: Unknown
Due 7 December 1988
Resolved 7 December 1988
Electrical
Issued 16 March 1987
Resolved
PROVIDE LEAD LINED BATTERY BOX FOR STARTING BATTERIES FOR STANDBY GENERATOR46 CFR 111.15-5(H).
Condition: Unknown
Due 16 March 1987
Resolved 16 March 1987
Construction/Loadline
Issued 29 May 1986
Resolved
CROP AND RENEW (OR CROP AND PERMANENTLY CAP OFF) THE THREE WASTED LOADING PIPES LOCATED ON THE STBD SIDE, MIDSHIP. (PORTABLE WATER, DRILL WATER; FUEL LINE PIPES ARE WASTED WHERE THEY PENETRATE THE MAIN DECK).
Condition: Unknown
Due 29 May 1986
Resolved 29 May 1986
Construction/Loadline
Issued 29 May 1986
Resolved
REPAIR OR RENEW ALL OF THE WASTED DOGS AND ASSOCIATED NUTS AND PINS TO THE FOLLOWING WATERTIGHT DOORS; (1) PORT AND STBD W/T DOORS ON STAIRWAY HOUSINGLEADING TO ENGINE ROOM; AND W/T DOOR OR MAIN DECK LEADING TO MUD PITS.
Condition: Unknown
Due 29 May 1986
Resolved 29 May 1986
Accommodation/Occupational Safety
Issued 16 April 1986
Resolved
INSTALL RELIEF VALVES ON HOT WATER HEATERS TO RELIEVE AT NOT MORE THAN 100 PSIG AND 200 DEGREES F.
Condition: Unknown
Due 16 April 1986
Resolved 16 April 1986
Accommodation/Occupational Safety
Issued 16 April 1986
Resolved
PROVE SATISFACTORY OPERATION OF INSTALLED MARINE SANITATION DEVICE.
Condition: Unknown
Due 16 April 1986
Resolved 16 April 1986
Construction/Loadline
Issued 16 April 1986
Resolved
REPAIR / MAKE OPERATIONAL THE DOGS ON THE WATERTIGHT HATCH LOCATED IN THE MAIN BATH TO VOID.
Condition: Unknown
Due 16 April 1986
Resolved 16 April 1986
Lifesaving
Issued 16 April 1986
Resolved
PROVE SATISFACTORY OPERATION OF THE BREATHING AIR REGULATOR / RELIEF VALVE SYSTEM IN THE STARBOARD CAPSULE. RELIEF VALVE WOULD NOT LIFT AT PRESSURE GREATER THAN 2800 PSI, BOTTLES APPEAR TO BE OVER PRESSURIZED, 2640 PSI MAX.
Condition: Unknown
Due 16 April 1986
Resolved 16 April 1986
Deck/Cargo
Issued 16 April 1986
Resolved
TEST OIL TRANSFER HOSE AND PROVIDE TRANSFER EQUIPMENT RECORDS IN ACCORDANCE WITH 33 CFR 155.800 AND 33 CFR 155.820.
Condition: Unknown
Due 16 April 1986
Resolved 16 April 1986
Deck/Cargo
Issued 16 April 1986
Resolved
PROVIDE ADEQUATE EMERGENCY LIGHTING IN OLD MUD PIT SPACE.
Condition: Unknown
Due 16 April 1986
Resolved 16 April 1986
Fire Fighting
Issued 16 April 1986
Resolved
REPLACE FLEXABLE HOSE FROM TOP OF DRY CHEMICAL TANK TO DISCHARGE HOSE.
Condition: Unknown
Due 16 April 1986
Resolved 16 April 1986
Unknown
Issued 16 April 1986
Resolved
MAKE OPERABLE CABLE GUIDE ROLLER, PORT CRANE.
Condition: Unknown
Due 16 April 1986
Resolved 16 April 1986
Accommodation/Occupational Safety
Issued 16 April 1986
Resolved
REPPPAIR OR REPLACE TREAD HOUSING ON LADDER FROM MAIN DECK TO LOWER DECK STARBOARD SIDE AFT.
Condition: Unknown
Due 16 April 1986
Resolved 16 April 1986
Documentation
Issued 16 April 1986
Resolved
PROVIDE ON BOARD AN APPROVED OPERATION MANUAL AND STABILITY LETTER.
Condition: Unknown
Due 16 April 1986
Resolved 16 April 1986
Electrical
Issued 16 April 1986
Resolved
PROVIDE ON BOARD AN APPROVED HAZARDOUS LOCATION PLAN.
Condition: Unknown
Due 16 April 1986
Resolved 16 April 1986
Lifesaving
Issued 16 April 1986
Resolved
PROVIDE ON BOARD REQUIRED FIRST AID EQUIPMENT PER 46 CFR 108.707, REF. 30 CFR 77.17-07.
Condition: Unknown
Due 16 April 1986
Resolved 16 April 1986