Records from 1987 to 1999. Most recent: inspection, 21 October 1999.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 15
21 October 1999
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 433814
1 October 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 433337
17 September 1999
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 432803
8 August 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 419084
8 August 1998
Letter of Compliance (Initial/Renewal) · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 809250
21 April 1993
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1153574
1 March 1993
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 356650
1 March 1993
Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1447217
25 May 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 469332
3 July 1991
Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 940098
16 October 1989
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 333075
16 October 1989
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1352134
23 November 1987
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 319816
23 November 1987
Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1025709
18 November 1987
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 525643
Navigation
Issued 1 October 1999
Resolved
NO.1 STEERING PUMP BRIDGE CONTROL NOT IN CALIBRATION WITH NO.2 STEERING PUMP (NO.1 PUMP CAN ONLY ACHIEVE 28 DEGREES PORT IN BRIDGE CONTROL). PROVIDE CLASS REPORT PROVING SATISFACTORY OPERATION PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 22 October 1999
Resolved 22 October 1999
Construction/Loadline
Issued 1 October 1999
Resolved
REPAIR WASTED AND HOLED AIR ESCAPE PIPE FOR STEERING FLAT AFT SECTION OF WHEELHOUSE PORT SIDE.
Condition: Unknown
Due 22 October 1999
Resolved 22 October 1999
Electrical
Issued 1 October 1999
Resolved
REPAIR LIGHT FIXTURE ABOVE STEERING PUMPS INSTEERING FLAT PRIOR TO NEXT U.S. PORT
Condition: Unknown
Due 22 October 1999
Resolved 22 October 1999
Lifesaving
Issued 17 September 1999
Resolved
Complete boat drills to the satisfaction of the attending CG Inspector prior to departing St. Croix.
Condition: Unknown
Due 17 September 1999
Resolved 1 October 1999
Engineering
Issued 17 September 1999
Resolved
4. Make repairs to open thermometer port in the fuel-settling tank.
Condition: Unknown
Due 22 October 1999
Resolved 22 October 1999
Accommodation/Occupational Safety
Issued 17 September 1999
Resolved
Clean grill vent hood.
Condition: Unknown
Due 17 October 1999
Resolved 1 October 1999
Accommodation/Occupational Safety
Issued 17 September 1999
Resolved
Renew hospital lights.
Condition: Unknown
Due 22 October 1999
Resolved 22 October 1999
Fire Fighting
Issued 17 September 1999
Resolved
8. Provide fire hoses and spanner for firebox 3,4 and 6 prior to departure from St. Croix.
Condition: Unknown
Due 17 October 1999
Resolved 1 October 1999
Accommodation/Occupational Safety
Issued 17 September 1999
Resolved
Make repairs to toilets.
Condition: Unknown
Due 22 October 1999
Resolved 22 October 1999
Electrical
Issued 17 September 1999
Resolved
3. Provide electrical non-conducting mat for the switchboard in engine control room.
Condition: Unknown
Due 17 October 1999
Resolved 1 October 1999
Electrical
Issued 17 September 1999
Resolved
2. Provide light covers as needed throughout the vessel. Noted missing covers above the O.W.S. and the ballast pump controls.
Condition: Unknown
Due 22 October 1999
Resolved 22 October 1999
Lifesaving
Issued 17 September 1999
Resolved
Complete fire drill to the satisfaction of the attending CG inspector priorto departure from St. Croix.
Condition: Unknown
Due 17 September 1999
Resolved 1 October 1999
Lifesaving
Issued 17 September 1999
Resolved
14. Make repairs to port lifeboat davit to satisfaction of class prior to departure from St. Croix.
Condition: Unknown
Due 17 September 1999
Resolved 1 October 1999
Construction/Loadline
Issued 17 September 1999
Resolved
13. Make repairs to cargo pump room bilge pump shaft bearing priot to _x001C_ departing St. Croix.
Condition: Unknown
Due 22 October 1999
Resolved 22 October 1999
Fire Fighting
Issued 17 September 1999
Resolved
9. Remove approximately one-inch rubber hose attached to number six fire hydrant.
Condition: Unknown
Due 17 September 1999
Resolved 1 October 1999
Engineering
Issued 17 September 1999
Resolved
Prove operation of the O.W.S. prior to departure from St. Croix.
Condition: Unknown
Due 17 September 1999
Resolved 1 October 1999
Lifesaving
Issued 17 September 1999
Resolved
11. Make emergency exit from steering space operable from both sides. Properly label exterior of exit.
Condition: Unknown
Due 17 September 1999
Resolved 1 October 1999
Lifesaving
Issued 17 September 1999
Resolved
12. Make repairs to port and starboard gangway to satisfaction of class.
Condition: Unknown
Due 6 December 1999
Resolved 6 December 1999
Engineering
Issued 17 September 1999
Resolved
Make repairs to main engine fuel expansion tank return funnel located in the vicinity and forward of the top of the aux. Boiler on the main deck level in the engine room.
Condition: Unknown
Due 1 October 1999
Resolved 1 October 1999
Lifesaving
Issued 8 August 1998
Resolved
Have class review the condition of both lifeboats as they are heavily patched with doublers and fiberglass. Make repairs as necessary and providea report to the USCG prior to the vessels departure._x001C_ SOLAS 74 III/5
Condition: Unknown
Due 8 November 1998
Resolved 10 December 1998
Navigation
Issued 8 August 1998
Resolved
Make permanent repairs to the wasted reefer cooling line about the steeringgear controls prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 74 I/11
Condition: Unknown
Due 1 October 1999
Resolved 1 October 1999
Fire Fighting
Issued 8 August 1998
Resolved
Overhaul the fire main valves to the foam monitors. Several leak past during operation and most are difficult to operate with out a valve wrench.Complete prior to return to a U. S. port. _x001C_ SOLAS 74 II-2/61
Condition: Unknown
Due 1 October 1999
Resolved 1 October 1999
Engineering
Issued 8 August 1998
Resolved
Repair the fuel leaks about the ship's incinerator and the control system for the fuel heater on the ship's auxiliary boiler prior to return to a U.S. port._x001C_ SOLAS 74 I/11
Condition: Unknown
Due 1 October 1999
Resolved 1 October 1999
Engineering
Issued 8 August 1998
Resolved
Renew the wasted piping on the M/E L/O heat exchanger prior to return to a U. S. port._x001C_ _x001C_ SOLAS 74 II-1/28
Condition: Unknown
Due 1 October 1999
Resolved 1 October 1999
Fire Fighting
Issued 8 August 1998
Resolved
Repair the packing on the main fire pumps as they both are leaking excessively prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 74 II-2/52(b)
Condition: Unknown
Due 1 October 1999
Resolved 1 October 1999
Construction/Loadline
Issued 8 August 1998
Resolved
Repair the holes in the deck framing about the hatch covers to #1 stbd & #4port cargo tanks prior to return to a U. S. port._x001C_ _x001C_ ICLL 66 I/1
Condition: Unknown
Due 1 October 1999
Resolved 1 October 1999
Deck/Cargo
Issued 8 August 1998
Resolved
Repair the holes in the covers to the temperature sensors on #5 stbd and #4port/stbd cargo tanks prior to return to a U. S. port._x001C_ _x001C_ BCH 2.15
Condition: Unknown
Due 1 October 1999
Resolved 1 October 1999
Accommodation/Occupational Safety
Issued 8 August 1998
Resolved
Renew the wasted decking about the port/stbd cargo manifold valves prior toreturn to a U. S. port._x001C_ _x001C_ BCH 2.10
Condition: Unknown
Due 1 October 1999
Resolved 1 October 1999
Construction/Loadline
Issued 8 August 1998
Resolved
Repair the hole in the fwd vent on the forecastle prior to return to a U. S. port._x001C_ _x001C_ ICLL 66 II/19
Condition: Unknown
Due 1 October 1999
Resolved 1 October 1999
Engineering
Issued 8 August 1998
Resolved
Make permanent repairs to the wasted bunker station lines (fwd of main deckhouse) prior to future use or remove from service. Complete prior to return to a U. S. port. _x001C_ 33 CFR 155.430
Condition: Unknown
Due 1 October 1999
Resolved 1 October 1999
Fire Fighting
Issued 8 August 1998
Resolved
Have class review the location of the emergency fire pump exhaust line and make modifications as necessary. Stern becomes inaccessible during operation of the engine due to the exhaust. Complete prior to return to a U. S. port. SOLAS 74 II-2/52(b)
Condition: Unknown
Due 1 October 1999
Resolved 1 October 1999
Fire Fighting
Issued 8 August 1998
Resolved
Repair the fire main leaks in the cargo pump room prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 74 II-2/52(b)
Condition: Unknown
Due 17 September 1999
Resolved 17 September 1999
Navigation
Issued 1 March 1993
Resolved
U.S. COAST PILOT FOR AREA TRANSITTED NOT ONBOARD.
Condition: Unknown
Due 10 December 1998
Resolved 10 December 1998
Navigation
Issued 1 March 1993
Resolved
USCG LIGHT LIST FOR AREA TRANSITED NOT ONBOARD.
Condition: Unknown
Due 10 December 1998
Resolved 10 December 1998
Navigation
Issued 1 March 1993
Resolved
CHART FOR AREA TRANSITED NOT CURRENTLY CORRECTED.
Condition: Unknown
Due 10 December 1998
Resolved 10 December 1998
Lifesaving
Issued 1 March 1993
Resolved
Install non-conductive matting or grating in front of electrical switchboards in engine room control room.
Condition: Unknown
Due 1 March 1993
Resolved 1 March 1993
Deck/Cargo
Issued 1 March 1993
Resolved
Install missing blanks on all used cargo hoses in accordance with Title 33 Code of Federal Regulations Part 156.120.
Condition: Unknown
Due 1 March 1993
Resolved 1 March 1993
Documentation
Issued 1 March 1993
Resolved
Provide accurate oil transfer procedures in accordance with Title 33 Code_x001C_ of Federal Regulations, Part 155.750.
Condition: Unknown
Due 1 March 1993
Resolved 1 March 1993
Deck/Cargo
Issued 1 March 1993
Resolved
Install mechanical means of closing deck scuppers. Remove cement and wooden plugs.
Condition: Unknown
Due 1 March 1993
Resolved 1 March 1993
Documentation
Issued 1 March 1993
Resolved
Submit a vessel response plan to the Coast Guard prior to 18 August 1993.
Condition: Unknown
Due 21 April 1993
Resolved 21 April 1993
Engineering
Issued 1 March 1993
Resolved
Make proper repairs to number 2 fuel oil tank containment where cracked.
Condition: Unknown
Due 1 March 1993
Resolved 1 March 1993
Deck/Cargo
Issued 16 October 1989
Resolved
VESSEL HAS NO CARGO EMERENCY SHUT DOWN DEVICES ON DECK.
Condition: Unknown
Due 25 May 1992
Resolved 26 May 1992
Fire Fighting
Issued 23 November 1987
Resolved
PROVIDE ADEQUATE DOCUMENTATION OF SATISFATORY FOAM ANALYSIS,AS REQUIRED.
Condition: Unknown
Due 2 March 1993
Resolved 2 March 1993
Unknown
Issued 23 November 1987
Resolved
PROVIDE ONBOARD TWO (2) ADDITIONAL CHEMICAL SUITS FOR A TOTAL OF FOUR, AS REQUIRED.
Condition: Unknown
Due 2 March 1993
Resolved 2 March 1993
Fire Fighting
Issued 23 November 1987
Resolved
PROVIDE ONBOARD TWO (2) ADDITIONAL FIREMAN OUTFITS FOR A TOTAL OF FOUR, AS REQUIRED.
Condition: Unknown
Due 2 March 1993
Resolved 2 March 1993