MAURY USCG vessel records Sign in
← All vessels

GEORGIOS S

GEORGIOS S is a 2001 freight ship. The Coast Guard has recorded 7 inspections since 2001, most recently in August 2011, along with 2 deficiencies — 1 with no resolution recorded —.

Records from 2001 to 2011. Most recent: inspection, 19 August 2011.

Built
2001
Last inspected
19 August 2011
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9233507 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
GREECE
—
Maury page id
psix-24054

Inspections, by type

…with no type recorded1
…past their stated due date1
Years with a record 7 calendar years (2001–2011)
The 7 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it38928 - Convention (Subpart B), Gross Ton
74249 - Dead Weight, Ton
84638 - Displacement, Ton
24319 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 7

19 August 2011 PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4106036
13 March 2008 PII Safety Exam · MARPOL Annex I Examination · ISPS II Exam · Ballast Water Examination · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3159777
24 January 2007 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2855249
26 October 2005 MARPOL Annex I Examination · Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2518046
8 October 2004 ISPS II Exam · PII Safety Exam
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2216812
28 July 2002 Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1653003
18 September 2001 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 294145

Deficiency record · 2

Engineering › Sea-water System (primary cooling) › Piping
Issued 19 August 2011 No resolution recorded
1499 - Other (Prop. and Aux. Machinery) - The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger. PSCO found soft patch on raw water supply pipe to MDE and SSDGs leaking. SOLAS 74/78 II-1, REG 26.
Action required: 705 - Other - as specified
Due 26 August 2011 — due date passed with no resolution recorded
Resolution: Received class report from [name withheld] stating all outstanding deficiencies have been rectified. The class report/ proper documentation stated that repairs were made by renewing section 0f 8" pipe and flange. Surveyor did note any leaks after repairs.
Documentation › Certificates/Documents › Exemption Certificate (SOLAS)
Issued 26 October 2005 Resolved
0710 Vessel Cargo Spaces not protected by fixed SOLAS II-2 Reg 53 Fire extinguishing system and ship does not have an exemption certificate as listed on Cargo Ship Safety Certificate. Ship must provide either exemption Certificate or Install Fire fighting system prior to departing this port. Action Taken 17a
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 October 2005
Resolution: Class has described to us that an exemption certificate will not be issued to this vessel

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.