← All vessels
NASSAU PARADISE
NASSAU PARADISE is a 1984 freight ship. The Coast Guard has recorded 39 inspections since 1984, most recently in January 2012, along with 25 deficiencies and 1 operational control.
Records from 1984 to 2012. Most recent: inspection, 9 January 2012.
- Built
- 1984
- Last inspected
- 9 January 2012
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 25 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8110318 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
C6FF4
240576
Flag
PANAMA
—
Maury page id
psix-240576
Inspections, by type
…with no type recorded29
Years with a record
23 calendar years (1984–2012)
The 39 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it13073 - Convention (Subpart B), Net Ton
35175 - Dead Weight, Ton
43074 - Displacement, Ton
21193 - Convention (Subpart B), Gross Ton
35175 - Dead Weight, Ton
43074 - Displacement, Ton
21193 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 39
9 January 2012
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4221506
18 February 2011
Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3948231
6 October 2008
PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3339357
22 February 2008
MARPOL Annex V Examination · MARPOL Annex I Examination · PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3151586
9 November 2007
Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3096032
11 July 2007
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2990935
25 October 2005
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2521901
30 August 2005
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2479467
5 May 2003
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1786981
8 April 2003
Annual Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1766497
7 April 2003
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1770879
16 July 2002
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1647538
19 March 2002
MARPOL Annex I Examination · Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1494420
21 February 2000
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 274998
21 August 1999
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 431885
19 March 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 426831
20 January 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 424766
12 October 1997
Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 408875
22 January 1997
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 399654
1 July 1996
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 392620
6 July 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 380469
1 March 1994
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 364833
25 August 1993
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 360385
21 February 1993
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 356454
9 March 1992
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 349334
31 December 1991
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 347891
23 December 1991
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 118084
26 December 1990
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 340979
10 September 1990
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 339208
31 May 1990
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 459795
24 January 1990
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 334933
30 January 1989
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 328200
23 November 1988
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 509880
18 February 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 321428
11 August 1987
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 469475
15 April 1987
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 316214
8 December 1986
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 313201
25 November 1985
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 305599
4 December 1984
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 299277
Deficiency record · 25
Engineering › Diesel Engine (propulsion-reduction gear) › Blower, Centrifugal
Issued 18 February 2011
Resolved
1410:Main engine auxiliary fan motor found w/ portable blower fan operating to cool said motor. Motor was covered in oil & dripping oil from its casing. C/E stated fan was used to cool the motor. Engine not reliable at maneuvering speed in this condition. 74 SOLAS (2004 Cons.) Reg I/11. 60ac.
Fire Fighting › Combustible Materials › Insulation
Issued 18 February 2011
Resolved
1499: Fuel oil purifier room has gross leaks of fuel oil (fuel oil pumps, purifiers, & associated piping). Several pipes have lagging saturated w/ fuel oil and pose a significant fire hazard. 74 SOLAS (2004 Cons.) I/11. 17ac.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 18 February 2011
Resolved
Oil filtering equipment to be designed w/ regard to specs recommended by Organization. Recirculating facilities to be provided to enable oil filtering equipment testing w/ overboard discharge valve closed. C/E was unable to test the oil water separator & OCM with the overboard discharge valve closed. The manufacturer's instructions for the OCM were not onboard. MARPOL 73/78 Anx I/14.6 MEPC.60(33).
Engineering › Sea-water System (primary cooling) › Piping
Issued 18 February 2011
Resolved
1499 Condition of ship & equipment shall be maintained to conform w/ provisions of present regs to ensure ship will remain fit to proceed to sea w/o danger to ship/persons onboard. Numerous temporary repairs to essential piping throughout the engine room (#2 seawater cooling pump for generators & #2 general service pump) w/o documentation of future permanent repairs. 74SOLAS(2004 Cons) I/11. 17ac
Documentation › Safety/Response Plans/Programs › Ballast Water Management Plan
Issued 11 July 2007
Resolved
The Ballast Water Management Plan is not ship specific. The plan does not include a diagram of sampling points, records of sediment, or records of training. No records of training could be produced. 33CFR151.2035
Operations/Management › Pollution › Control of Garbage
Issued 11 July 2007
Resolved
The Garbage Management Plan is not ship specific. The plan does not address procedures for disposing of expired medicine and hospital waste, batteries, or light bulbs. The garbage management plan does not give detailed information on proper segregation of garbage types or provide incinerator usage instructions for what garbage types can be burned. The incineration of garbage is not recorded.
Engineering › Sea-water System (primary cooling) › Valve
Issued 11 July 2007
Resolved
The saltwater valve for the number 2 cooling pump for the generators has a cement box patch and is leaking water excessively. SOLAS 74(am) I/11
Deck/Cargo › Cargo Stowage › General
Issued 11 July 2007
Resolved
The hydraulic cylinders for the cargo hatches are leaking in excess and are causing a pollution and personnel safety hazard. SOLAS 74 (am) I/11
Operations/Management › Pollution › Control of Discharge of Sewage
Issued 11 July 2007
Resolved
The monthly chlorine test required by the manufacturers instructions is not being done. There is no test kit on board. 33CFR159.121
Engineering › Shafting/Propeller Arrangements
Issued 8 April 2003
Resolved
Sealant around stern tube leaking causing water to mix with oil and also allowing oily water to go into San Diego Bay. LEGACY COMPONENT DESC: Stern Tube
Engineering
Issued 19 March 1999
Resolved
SSG OVERBOARD VALVE IS PATCHED WITH A STEEL/CEMENT BOX PATCH
Accommodation/Occupational Safety
Issued 20 January 1999
Resolved
Galley is infested and in need of fumigation. Proof of same by professionalagency is to be submitted prior to departure. PWSA 33 USC 1223(b)
Navigation
Issued 1 July 1996
Resolved
VESSEL WAS MISSING CHART FOR NAVIGATION IN NEWARK BAY.
Fire Fighting
Issued 1 July 1996
Resolved
VESSEL'S #3 STBD, #5 PORT AND STBD FIRE HOSES AND NOZZLES WERE WORN AND WASTED.
Fire Fighting
Issued 1 July 1996
Resolved
VESSEL'S INTERNATIONAL SHORE CONNECTION DID NOT FIT ON THE VESSEL'S FIRE HYDRANTS.
Navigation
Issued 1 July 1996
Resolved
VESSEL'S COAST PILOT WAS NOT CORRECTED UP TO DATE. COPY OF THE COAST PILOTCHAPTER 2 1994 EDITION PURCHASED NEW AT LAST PORT OF CALL, BUT DID NOT INCLUDE CORRECTIONS.
Navigation
Issued 1 July 1996
Resolved
VESSEL'S LIGHT LIST WAS NOT CORRECTED UP TO DATE. VESSEL ORDERED LIGHT LIST IN LAST PORT OF CALL, BUT WAS NOT INCLUDED WITH SHIPMENT.
Documentation
Issued 6 July 1995
Resolved
MASTER TO PROVIDE CLASS/ADMINSTATION DUCUMENTATION THAT MANNING MEETS THE REQUIREMENTS OF THE MINIMUM SAFE MANNING CERTIFICATE ISSUED BY THE REPUBLICOF PANAMA.
Fire Fighting
Issued 6 July 1995
Resolved
REPAIR WASTED FIREMAIN FORWARD SIDE STARBOARD OF #2 HATCH TO THE SATISFACTION OF ATTENDING CLASS SURVEYOR.
Navigation
Issued 1 March 1994
Resolved
33 CFR 88.05 The vessel did not have a copy of the Inland Navigation Rules.
Lifesaving
Issued 1 March 1994
Resolved
SOLAS The vessel's inflatable liferafts did not have weak links to ensure they would be in a float free arrangement.
Engineering
Issued 31 December 1991
Resolved
33 CFR 155.370(a)(2) VESSEL DID NOT HAVE AN OPERABLE 15 PPM OWS ALARM._x001C_ _x001C_ _x001C_ _x001C_
Documentation
Issued 30 January 1989
Resolved
33CFR151.25(H) EACH OPERATION IN THE OIL RECORD BOOK WAS NOT SIGNED BY THE PERSON IN CHARGE. AUTHORITY:33USC1903(B) PENALTY:33USC1908(B)
Navigation
Issued 8 December 1986
Resolved
U.S.LIGHT LIST VOL III 1985 ED, NOT CURRENTLY CORRECTED MISSING NOTICE TO MARINERS CORRECTIONS AS FOLLOWS: 1986-17,18,20,21,22,23,25,26,27,28,29,31, 32,33,34,3,38,41,42,43,46,47,49.
Documentation
Issued 8 December 1986
Resolved
FAILURE TO GIVE REQUIRED 24 HOUR ADVANCE NOTICE OF ARRIVAL TO COTP SAN FRANCISCO BAY,CA. VESSELS GROSS TONNAGE IS 21,193 TONS.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.