Inspection history · 13
19 April 2026
PSC A · COC-CVE Initial
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8350822
25 February 2024
COE-Administrative
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7869898
24 February 2024
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7869685
12 February 2024
PSC B
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7861796
27 October 2023
COC-CVE Initial · PSC A
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7814161
27 October 2023
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7815248
17 April 2023
COC-CVE Initial Prep
Type not classified · Activities Europe · Activity 7672755
9 January 2019
Ballast Water Examination · ISPS III Exam · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6607045
8 January 2019
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6607153
18 April 2018
COC-CVE Quarterly
Type not classified · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6394187
20 October 2017
COC-CVE Initial
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6291625
18 October 2017
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6289428
2 September 2016
COC-CVE Initial Prep
Type not classified · Activities Europe · Activity 5990132
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 19 April 2026
Resolved
Crew members shall be trained to be familar with the arrangements of the ship as well as the location and operation of any fire-fighting systems and appliances that they may be called upon to use. Crew members on life boat #s 2 and 4 were not familiar with the location of emergency fuel shut off valves.
74 SOLAS 20, II-2/15.2.2.1
Code 16
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2026
Resolved 19 April 2026
Resolution: Training with crew conducted to cover life boat equipment service and location of emergency fuel shutoff valves on the life boats.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 19 April 2026
Resolved
In and all passenger and crew spaces and in spaces in which the crew is normally employeed... shall be arranged with ready means of escape. PSCO noted escape routes in crew corridor on Deck 1 and secondary hospital on Deck 9 were blocked.
74 SOLAS II-2/21(a)
Code 16
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2026
Resolved 19 April 2026
Resolution: PSCOs observed obstructions removed from corridor.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 19 April 2026
Resolved
The speed of door closure shall, if necessary, be controlled so as to prevent undue danger to personnel. PSCOs observed each fire door tested in every stair well (to inlcude FD 236, 155, 817, 820, 106A, 727, 121, 005, TWD 06, TW03, 119, 117, 112, 109, 105 and more) slammed closed between 2-4 seconds. The weight and speed of door closure could cause undue danger to any person in way of door closure.
74 SOLAS II-2/23(f)
Code 16
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2026
Resolved 20 April 2026
Resolution: PSCO tested fire door closures after adjustments were made to slow down the rate of closure.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 27 October 2023
Resolved
Stairways and ladders shall be arranged to provide ready means of escape to the lifeboat and liferaft embarkation deck from all passenger and crew spaces and from spaces in which the crew is normally employed, other than machinery spaces. Means of escape not clearly marked in officers mess, medical treatment room, behind stage storage, and corridor outside Port side aft provision room.
74 SOLAS 81 Amend II-2/28.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 October 2023
Resolution: Received class report. Def resolved.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 27 October 2023
Resolved
Stairways and ladders shall be arranged to provide ready means of escape to the lifeboat and liferaft embarkation deck from all passenger and crew spaces and from spaces in which the crew is normally employed, other than machinery spaces. Means of escape in crew medical waiting area was blocked by curtains chairs and medical equipment storage. Routes of escape from Four Seasons restaurant, FD 238, FD 239, and route leading FWD from theater near FD 306 were obscured with curtains.
74 SOLAS 81 Amend II-2/28.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 October 2023
Resolution: Received class report. Def resolved.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 27 October 2023
Resolved
Fire doors in main vertical zone bulkheads and stairway enclosures, other than power-operated watertight doors and those which are normally locked shall be of the self-closing type. The speed of the door closure shall, if necessary, be controlled as to prevent undue danger to persons. Spot-checked various types of fire doors throughout all main vertical zones, across all decks and observed an excessive number of fire doors closing in a manner that may cause harm to passengers and crew members based on the speed of closure (approx. 2-6 seconds)
74 SOLAS 81 Amend II-2/30.4
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 October 2023
Resolution: Received class report.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 October 2023
Resolved
Electrical installations shall be such that electrical services for safety will be ensured under various emergency conditions. Electrical junction box for retrofitted emergency lighting in weld workshop and the light fixture in the isolation valve space were found secured with zip-ties.
74 SOLAS 81 Amend II-1/40.1.2.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 November 2023
Resolved 28 October 2023
Resolution: Received class report acknowledging def will be completed in 14 days.