MAURY USCG vessel records Sign in
← All vessels

NISSAKI

NISSAKI is a 1984 freight ship. The Coast Guard has recorded 28 inspections since 1984, most recently in November 2007, along with 20 deficiencies and 2 operational controls.

Records from 1984 to 2007. Most recent: inspection, 4 November 2007.

Built
1984
Last inspected
4 November 2007
Documentation
Invalid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8323707 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
240715
Flag
PANAMA
—
Maury page id
psix-240715

Inspections, by type

…with no type recorded24
Years with a record 17 calendar years (1984–2007)
The 28 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Registered dimensions (L × B × D)524.9 ft × 82.0 ft × 44.9 ft
Registered tonnagegross 15,045 / net 8,740
ITC dimensions (L × B × D)Not recorded
ITC tonnagegross 15,045 / net 8,740
Builderbuilt 1984
Hull materialSteel
PropulsionDiesel Direct
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portLimassol, CYPRUS
Trade endorsementsNot recorded
DocumentationInvalid
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it8740 - Convention (Subpart B), Net Ton
15045 - Convention (Subpart B), Gross Ton
24941 - Dead Weight, Ton
30578 - Displacement, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 28

4 November 2007 ISPS II Exam · Ballast Water Examination · Deficiency Check · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3092775
3 July 2002 Administrative Inspection · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1640515
17 June 2002 Annual Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1631957
1 February 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 286723
23 January 2001 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 286030
1 October 1998 Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 420992
24 September 1998 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 420950
9 February 1998 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 412594
24 January 1997 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 399638
27 February 1996 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 387987
6 January 1996 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 386300
25 December 1994 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 373825
25 December 1994 Uninspected Other
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1162363
18 December 1993 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 363214
1 December 1992 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 354750
30 October 1991 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 669203
29 October 1991 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 346750
20 June 1990 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 337780
29 July 1989 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 331753
19 June 1989 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 330847
24 April 1988 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 322717
19 March 1987 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 315044
19 March 1987 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 315046
29 September 1986 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 311668
31 May 1986 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 491567
4 November 1985 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 305080
25 May 1985 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 484662
7 December 1984 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 299377

Deficiency record · 20

Fire Fighting › Miscellaneous Items
Issued 17 June 2002 Resolved
Fire control plan does not match emergency gear on board.
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 July 2002
Resolved 3 July 2002
Resolution: Received proper documentation, cleared deficiency.
Accommodation/Occupational Safety › Medical/First Aid
Issued 17 June 2002 Resolved
The toilet in the hospital is inoperable. LEGACY COMPONENT DESC: Hospital Space
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 July 2002
Resolved 3 July 2002
Resolution: Received proper documentation, cleared deficiency.
Deck/Cargo › Holds/Tanks
Issued 17 June 2002 Resolved
No. 1 hold hydraulic hatch control is leaking. LEGACY COMPONENT DESC: Hatch Cover
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 June 2002
Resolved 3 July 2002
Resolution: Received proper documentation, cleared deficiency.
Fire Fighting
Issued 23 January 2001 Resolved
Did not perform satisfactory fire drill.
Condition: Unknown
Due 1 February 2001
Resolved 1 February 2001
Navigation
Issued 9 February 1998 Resolved
Provide corrected charts prior to departure._x001C_ 33 C.F.R. 164.33
Condition: Unknown
Due 10 February 1998
Resolved 11 February 1998
Lifesaving
Issued 9 February 1998 Resolved
Prove proper operation of both lifeboat falls including free fall from cradle, limit switches, and brakes. Provide evidence of last davit wire rope renewal and repair gudgeon on starboard lifeboat rudder. Complete to the satisfaction of class prior to departure. SOLAS 74 III/36
Condition: Unknown
Due 10 February 1998
Resolved 11 February 1998
Fire Fighting
Issued 24 January 1997 Resolved
Provide fire extinguishing arrangements for the paint locker or evidence that flag administration accepts current arrangement. SOLAS 74 II-2/18.7. There was only one portable fire extinguisher inside the paint locker. There was not a fire detection system or a fixed fire extinguishing system.
Condition: Unknown
Due 11 February 1998
Resolved 11 February 1998
Electrical
Issued 24 January 1997 Resolved
Install nonconductive mats in front of the main switchboard in the engine control room.
Condition: Unknown
Due 11 February 1998
Resolved 11 February 1998
Fire Fighting
Issued 24 January 1997 Resolved
Properly install acceptable brackets for the fire extinguishers neat the oily water seperator in the engine room. SOLAS 74 II-2/7.
Condition: Unknown
Due 11 February 1998
Resolved 11 February 1998
Electrical
Issued 24 January 1997 Resolved
Remove or permanately install heat lamp above the forward mooring winch hydraulic pump motor. SOLAS II-1/27(a).
Condition: Unknown
Due 11 February 1998
Resolved 11 February 1998
Fire Fighting
Issued 6 January 1996 Resolved
Renew the water damaged fire control plan stored on poop deck, stbd side ofmain superstucture, prior to the next U.S. port call._x001C_ _x001C_ Solas Ch II-2, Reg 20
Condition: Unknown
Due 27 February 1996
Resolved 27 February 1996
Navigation
Issued 6 January 1996 Resolved
Repair the inoperative speed indicator onboard, prior to the next U.S. portcall._x001C_ _x001C_ 33 C.F.R 164.40
Condition: Unknown
Due 27 February 1996
Resolved 27 February 1996
Fire Fighting
Issued 6 January 1996 Resolved
Remove the hold back hook to the fire door for the emergency fire pump/steering gear compartment, prior to the next U.S. port call. _x001C_ _x001C_ Solas Ch II-2, Reg 47
Condition: Unknown
Due 27 February 1996
Resolved 27 February 1996
Lifesaving
Issued 6 January 1996 Resolved
Remove the paint stored in the crew cabin on the main accomodation deck, prior to the next U.S. port call._x001C_ _x001C_ Solas Ch II-2, Reg 2 (1)
Condition: Unknown
Due 27 February 1996
Resolved 27 February 1996
Electrical
Issued 6 January 1996 Resolved
Reinstall the missing components for the explosion proof lighting fixture in the paint locker, prior to the next U.S. port call. The bulb is currently exposed without a cover._x001C_ Solas Ch II-1, Reg 45
Condition: Unknown
Due 27 February 1996
Resolved 27 February 1996
Fire Fighting
Issued 6 January 1996 Resolved
Replace the broken mounting bracket for the portable fire extinguisher located on the aft forecastle bulkhead, prior to the next U.S. port call. The extinguisher is currently wired in and not easily accessible._x001C_ Solas Ch II-2, Reg 6
Condition: Unknown
Due 27 February 1996
Resolved 27 February 1996
Lifesaving
Issued 25 December 1994 Resolved
Prove proper operation of the starboard lifeboat lowering system. Provide class report on satisfactory repair of system. This item shall be completed prior to the vessel departing the Port of Longview, Washington. SOLAS Chpt III Reg 16.
Condition: Unknown
Due 30 December 1994
Resolved 30 December 1994
Navigation
Issued 29 October 1991 Resolved
VESSEL TRANSITED PUGET SOUND WATERS WITHOUT THE OPERABLE AUTOMATIC RADAR PLOTTING AID REQUIRED BY 33 C.F.R 164.38(b)(3)(iii).
Condition: Unknown
Due 2 December 1992
Resolved 2 December 1992
Navigation
Issued 19 June 1989 Resolved
OUTDATED US COAST PILOT 1987 ED. 33 CFR 164.25
Condition: Unknown
Due 19 June 1989
Resolved 19 June 1989
Accommodation/Occupational Safety
Issued 19 June 1989 Resolved
OPERATING A VESSEL EQUIPPED WITH INSTALLED TOILETS ONBOARD IN U.S. WATERS WITH A CERTIFIED MSD. MSD WAS BYPASSED TO DIRECT OVERBOARD DISCHARGE.
Condition: Unknown
Due 19 June 1989
Resolved 19 June 1989

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.