← All vessels
ENTERTAINER
Passenger (Inspected) · Passenger Ship class · Built 1980s · USCG Southwest District (CGD-SW) · Other hulls named ENTERTAINER
ENTERTAINER is a 1985 passenger vessel (inspected). The Coast Guard has recorded 119 inspections since 1984, most recently in January 2026, along with 91 deficiencies, 4 operational controls, 1 with no removal date recorded and 1 casualty investigation in 2017.
Records from 1984 to 2026. Most recent: inspection, 5 January 2026.
- Built
- 1985
- Last inspected
- 5 January 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Inspections
- 119
- Deficiencies
- 91 recorded · 0 without a recorded resolution
- Controls
- 1 with no removal date recorded
- Casualties
- 1 investigation · 2017
Identity
679587
WCQ6000
240759
Flag
UNITED STATES
367015530
Maury page id
psix-240759
Inspections, by type
…with no type recorded16
Years with a record
41 calendar years (1984–2026)
The 119 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)113.0 ft × 31.0 ft × 9.0 ft
Registered tonnagegross 96 / net 69
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBLOUNT MARINE CORPORATION · WARREN, RI, UNITED STATES · built 1985
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portLONG BEACH, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 12 August 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it96 - Regulatory (Subpart C or D), Gross Ton
69 - Regulatory (Subpart C or D), Net Ton
69 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WCQ6000MMSI 367015530 · active · compulsorily equipped · granted 14 February 2018, expires 17 February 2028
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 119
5 January 2026
Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8267695
18 June 2025
Vessel Attendance · Damage Survey · Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8161395
16 June 2025
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8160681
6 June 2025
Damage Survey · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8153942
16 April 2025
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8064868
14 October 2024
Plan Review (Other than "T") · Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8018528
1 October 2024
Plan Review (Other than "T") · Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7843511
15 June 2024
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7888865
6 February 2024
Examination of Repairs · Plan Review (Other than "T")
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7901670
24 January 2024
Hull Examination · Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7775196
18 November 2023
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7822045
27 September 2023
Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7605226
17 May 2023
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7675575
20 December 2022
Examination of Repairs · Plan Review (Other than "T") · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7611587
7 July 2022
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7466220
9 March 2022
Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7301894
20 September 2021
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7316624
2 September 2021
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7301944
2 November 2020
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7081578
19 October 2020
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7079977
4 March 2020
Deficiency Check · Drydock Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6903547
17 September 2019
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6774920
25 June 2018
Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6455828
11 April 2018
Drydock Exam · Deficiency Check · Administrative Inspection · Internal Structural Exam · Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6389850
11 July 2017
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6163774
9 April 2017
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6123241
20 October 2016
Annual Inspection · DAPI Audit
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6019987
22 July 2016
Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5952521
20 April 2016
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5856788
21 October 2015
DAPI Audit · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5199162
9 October 2014
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4955955
17 March 2014
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4816147
14 March 2014
Plan Review (Other than "T")
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4816305
25 July 2012
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4366411
20 July 2012
Damage Survey · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4384940
15 May 2012
Deficiency Check · DAPI Audit
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 4321688
12 September 2011
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4143184
14 October 2010
Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3853650
1 September 2010
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3832617
30 October 2008
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3340431
12 September 2008
Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3312319
26 June 2008
MTSA Verification
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3249011
29 April 2008
Drydock Extension
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3175564
21 February 2008
Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3150814
15 February 2008
Drydock Extension
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3148007
12 June 2007
Administrative Inspection
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 2966065
18 May 2007
Administrative Inspection
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 2958702
15 September 2006
In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2773124
21 March 2006
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2594009
3 November 2005
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2524221
20 October 2005
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2522108
11 May 2005
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2355354
10 February 2005
MTSA Verification
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2293910
13 January 2005
Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2274564
20 October 2004
Annual Inspection · Administrative Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2224226
9 April 2004
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2036228
12 March 2004
Drydock Extension
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2023331
22 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1970866
4 November 2003
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1941371
7 August 2002
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1655449
14 March 2002
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1493809
29 January 2002
Drydock Extension
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1486685
11 December 2001
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1482024
5 October 2000
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1379282
12 January 2000
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1388974
11 August 1999
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1447996
13 August 1998
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1452424
7 April 1998
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1123664
17 March 1998
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1433323
8 January 1998
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1120350
6 January 1998
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1120524
27 August 1997
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 785027
12 August 1997
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1428825
13 August 1996
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1371507
6 March 1996
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1461695
28 September 1995
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1193716
14 August 1995
Deficiency Check · COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1419481
6 January 1995
Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1167623
24 August 1994
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1173999
18 February 1994
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 858527
18 February 1994
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1382697
3 January 1994
Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1161772
4 December 1993
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 150186
3 December 1993
Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 847982
27 September 1993
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1362843
10 September 1993
Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 832444
25 August 1993
Hull Examination · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1387385
19 August 1993
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 845631
9 September 1992
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 938270
22 November 1991
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1253052
9 September 1991
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1244884
23 April 1991
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1235189
15 April 1991
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1225602
31 October 1990
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 928962
19 September 1990
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 925991
29 August 1990
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1239872
23 August 1990
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 928821
10 May 1990
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 918805
6 February 1990
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1210281
12 September 1989
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 893719
11 September 1989
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 897247
21 March 1989
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1207359
13 September 1988
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1348907
23 March 1988
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1273190
22 September 1987
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1007033
28 April 1987
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1011251
23 October 1986
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 312273
23 September 1986
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1312209
2 July 1986
Excursion Permit
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1298792
1 May 1986
Credit Drydock
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1308811
11 March 1986
Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1300005
17 December 1985
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1304195
20 February 1985
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1285268
8 February 1985
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1285129
5 February 1985
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 975995
31 January 1985
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 978753
24 January 1985
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1285864
10 January 1985
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1284808
13 December 1984
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 976438
Deficiency record · 91
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 5 January 2026
Resolved
Each window and its means of attachment to the hull or deck house must be capable of withstanding the maximum load from wave and wind conditions expected due to it’s location on the vessel. During dry dock inspection, forward lounge port window had stress cracks (3”-6”) radiating from fittings, and a forward lounge starboard window was missing most of its bolts from the frame.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 16 April 2025
Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck from all passenger and crew accommodation spaced located below the main deck. Vessel did not have adequate emergency lighting along 01 of the escape routes from the galley.46 CFR 120.432(a)
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 16 April 2025
Resolved
Each vessel that relies on electricity to power... the vital systems listed in 119.710 of this chapter must be arranged so that the loads can be energized from two sources of electricity... A vessel with batteries of adequate capacity to supply the loads for three hours. Vessel's fire detection panel battery backup did not last more than 1 hour. Vessel must provide proof that fire detection panel battery backup will last for three hours.46 CFR 120.310(a)(1)
46 CFR 120.310(a)(2)
04 - Emergency Systems › N/A - No Subsystem › Safe areas
Issued 16 April 2025
Resolved
Area of refuge means an area that is separated from the effects of fire and flooding where passengers and crew can gather to await disembarking in the event of fire or flooding. Vessel was storing chairs and other objects in the designated area of refuge, making it not operational as required in the event of emergency.46 CFR 114.400
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 October 2024
Resolved
Vessel experienced a mechanical failure on the port main engine while underway. The error code indicated a “Microcommander” fault.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 October 2024
Resolved
All microprocessor or computer based propulsion engine control systems must meet the requirements of part 62 in subchapter F of this chapter. A qualitative failure analysis (QFA) of the vessel’s propulsion engine control system (throttle) shall be submitted to MSC. A DVT Procedure (DVTP) document that incorporates all failure modes identified on the QFA should also be submitted for review to MSC. The QFA should specifically address the failure of the microprocessor based control system hardware and those inputs to the control system whose failure could affect the propulsion system’s ability to default to the required conditions in 46 CFR 121.620(c). The QFA must indicate continued compliance with 46 CFR 121.620 so that power failure to the processor or processor failure will not result in an increase of shaft speed or propeller pitch. The QFA should be based on single, non-concurrent system failures (including loss of power). Plans shall be submitted to [email withheld], submittal shall indicate vessel project number (P016675). Following approval from MSC the DVTP testing shall be accomplished to the satisfaction of the attending Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 October 2024
Resolved
Nonmetallic flexible hose may be used in lube oil, fuel oil and fluid power systems only where flexibility is required and in lengths not exceeding 30 inches. Nonmetallic flexible hose must have factory-assembled end fittings and must comply with SAE J1475. Appx 10 feet of a 15 plus foot run of flexible Aeroquip 2556-8 (1/2”) SAE 20R2, 250 psi lube oil hose is hanging between overhead and bow thruster tunnel. While this does not meet requirements, it appears satisfactory for its service on the pressure head tank to bowthruster. Concern is hanging 10' section with nearly 90 degree bend. Review and install per manufacturer specification 5" radius and supported along run per distributor website, which operator shall verify.
07 - Fire Safety › N/A - No Subsystem › Main Vertical zone
Issued 1 October 2024
Resolved
General construction of the vessel shall be such as to minimize fire hazards. Vessels constructed on or after 1 JUL 1961 which carry more than 150 passengers shall meet the requirements of subpart 72.05. Stairway enclosures adjacent to public spaces over 500 square feet, or adjacent to machinery spaces, or boundaries of main vertical zones shall be A-60. Wire penetration at top of machinery space vestibule (looking forward from door) is incomplete.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 October 2024
Resolved
All cable and wire must be installed with metal supports spaced not more than 610 millimeters (24 inches) apart, and in such a manner as to avoid chafing and other damage. The use of plastic tie wraps must be limited to bundling or retention of multiple cable installations, and not used as a means of support. MI identified hanging wires not supported by metal supports for the following: Bilge float switch located in steering gear space, light wiring located in steering gear, wire runs in port galley, wire runs aft of stbd main engine shaft seal access plate.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 October 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. MI identified the following unsafe electrical conditions: loose power outlet located in lazarette, loose power outlet located on port side 02 deck, and port fwd head distribution panel door not secured near port storage entry.
07 - Fire Safety › N/A - No Subsystem › Main Vertical zone
Issued 1 October 2024
Resolved
A door in A-class fire control boundary in a stairtower must be the self closing type. Self closing door in galley stair access to main deck does not fully close.
Gap less than 1/2" may continue operations until fixed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 1 October 2024
Resolved
Penetrations and openings in watertight bulkheads must have means to make them watertight. Penetrations in A Class fire control boundaries for electrical cables, pipes, trunks, ducts, must be constructed to prevent the passage of flame and smoke for one hour. MI identified wire penetration between steering gear space and aft storage space (a MWTB listed on vessels stability letter) bulk head not watertight or smoke/fume tight.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 October 2024
Resolved
A power driven vessel underway shall exhibit a stern light as required by 33 CFR 83.20. Stern light inoperable during inspection.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 1 October 2024
Resolved
Means of escape. The dimensions of a means of escape must be such as to allow easy movement of persons when wearing life jackets. There must be no protrusions in means of escape that could cause injury, ensnare clothing, or damage life jackets. Galley escape had tray rack, extinguishing pipe with 1” cable run hanging from tape in place, and wood dunnage obstructing the egress. The fixed extinguishing pipe presents a low overhead but could be adequate by keeping the space open, and the section of piping (at head level for 6’ person) could be fitted with highly visible markings and no cables hanging or objects that could snag clothing or life jackets. 177.15-1 All vessels shall be provided two avenues of escape from all general areas accessible or where the crew may be mornally employed, so located if one is not available the other may be.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 September 2023
Resolved
Bilge pumping line. During operational test, bilge discharge pipe had leak.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 September 2023
Resolved
Electrical cables and fixtures. Each connection to a connector or terminal connection must be made within an enclusre. Stbd galley service pway found to have two loose pigtails and a refrigerator pump connectors exposed.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 27 September 2023
Resolved
Lighting systems guards. Port galley in vicinity of water heater, and lower head(restroom) light fixtures were missing covers.
09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 27 September 2023
Resolved
Mess deck and galley spaces. Upper metal outboard of ovens found lowered and zip tied in place, defeating heat deflecting properties. Secure as designed.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 27 September 2023
Resolved
A vessel inspected for compliance with the standards required by this subchapter may be inspected in accordance with standards acceptable to the OCMI as good marine practice. During annual inspection, port rudder post found with wastage, which made a hole through a support strut at the upper connection to rudder post. 705 C defer to drydock (MAR 2024).
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 20 December 2022
Resolved
The master shall determine that the vessel complies with all applicable stability requirements. Vessel is currently awaiting approval of stability test and fire load analysis from MSC. Vessel may only operate with up to 300 maximum passengers until the plans are approved.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 28 April 2022
Resolved
Upon completion of the current alterations, a stability test(either deadweight survey or inclining) should be conducted on the vessel and revised loading conditions / stability calculations be prepared as necessary to demonstrate that the vessel’s stability remains adequate for the intended service. Sewage tank between frames 12 and 21 is wider than original; and a gray water collection tank (appx 2.5'x3'x15') was added aft of frame 46 and has not been documented. This change to the sewage tank and addition of collection tank should be included in stability calculations. Vessel may
operate with reduced passenger count, reduced from 600
to 500 (475 passengers, 8 crew, 17 other persons in crew
crew), through scheduled COI renewal of 7 JUL 2022.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 April 2022
Resolved
Repairs or alterations to the hull that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. The owner or managing operator shall submit drawings, sketches, or written specifications describing details of alterations to the cognizant [name withheld] pumps, piping and a grey water collection tank, approx- imately 2.5'x3'x15', were discovered during drydock,
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 4 April 2022
Resolved
Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered, the cognizant OCMI may conduct an internal structureal examination in any affected space and may require the vessel to be dry-docked or taken out of service to assess the extent of the damage and to effect permanent repairs. The OCMI may decrease the dry-dock examination intervals to monitor the vessels structural condition. Prior to relaunch, ensure marine inspectors witness satisfactory Non-destructive Testing (NDT) of the affected 17'9"x11' bottom plate, framing, and tank top repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 September 2021
Resolved
Bilge alarms did not alarm visually or audibly during operational test of system for clearing of prior CG-835v
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 2 September 2021
Resolved
All observed unsafe practices, fire hazards, and other situations must be corrected. Electrical wiring under the pilot house steering console was found to have dead end wires and exposed connections.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 September 2021
Resolved
Spanner wrench must be provided for each fire hydrant. Two spanner wrenches were found to be missing.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 2 September 2021
Resolved
Vessel did not have updated copies of FCC certificates onboard.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 September 2021
Resolved
Vessel had a 70 amp breaker installed into the galley panel and was using it as a blank.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 September 2021
Resolved
Vessel had a damaged power strip installed with a junction box, which showed a ground when tested.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 September 2021
Resolved
top/open deck aft the vessel had 2 outlet boxes 1 one each side that had the steel piping rotted through leaving wires exposed to element as well as water intrusion into the electric boxes.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 October 2020
Resolved
Your vessel must undergo an annual inspection within 3 months before or after each anniversary date. The vessel has not completed a satisfactory annual inspection. Vessel cannot carry passengers until a satisfactory annual inspection is completed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 September 2019
Resolved
A spanner wrench must be provided at each fire hydrant. Provide spanner wrench for hydrant #4.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 17 July 2018
Resolved
The vessel COI was found posted in the vessel's pilothouse where passengers could not view the certificate. Post COI in a location where it can be seen by all passengers.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 June 2018
Resolved
The lifebuoys had crew installed line that was not proven to be UV resistant and of an unknown breaking strength. Provide 60' of line that meets UV and strength requirements.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 June 2018
Resolved
During the inspection it was discovered that the steering tie rod pin connecting the tie rod end to the STBD rudder arm was missing a cotter pin.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 25 June 2018
Resolved
During the inspection it was discovered that the sewage overboard discharge valve was outfitted with a chain and lock, however the lock was not closed. The valve was closed at the time of the inspection.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 June 2018
Resolved
A discrepancy in the the vessels drug and alcohol testing program was discovered when one of the deckhands was not listed on the testing enrolment crew list.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 25 June 2018
Resolved
During the inspection it was discovered that the vessel's anchor light was extinguished.
Construction/Loadline › Hull › Hull Plating
Issued 22 July 2016
Resolved
Due to vsl alliding with the ground underwater, the vessel requires internal structural exam prior to carrying passnegers. Vessel is no sailed.
Construction/Loadline › Hull › Bottom Plating
Issued 22 April 2016
Resolved
Crop and renew bottom plating aft of port rudder post and forward of stbd rudder post.
Construction/Loadline › Hull › Stiffener
Issued 20 April 2016
Resolved
Crop and renew inboard support pole for starboard side rudder post as marked, in kind.
Construction/Loadline › Hull › Stiffener
Issued 20 April 2016
Resolved
Crop and renew aft support pole and stantion as marked for port rudder post, in kind.
Construction/Loadline › Hull › Hull Plating
Issued 20 April 2016
Resolved
Grind to good metal and provide gaging report for hul plating under port and starboard ruder posts, as marked.
Electrical › Electric Supply System (service) › Cable
Issued 9 October 2014
Resolved
Remove installed extension cord in 2nd deck overhead. Provide proper installed electrical wiring.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 9 October 2014
Resolved
Provide accurate Fire Plan.
Engineering › Steering Gear System › Rudder Bearing
Issued 25 July 2012
Resolved
Repair or adjust rudder shaft packing. Water is coming thru top portion of rudder when the ship is manuvering hard to port or starboard.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 25 July 2012
Resolved
Provide 01 additional adult lifejacket.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 25 July 2012
Resolved
Replace retro-reflective material on 26 life jackets.
Construction/Loadline › Hull › Bottom Plating
Issued 20 July 2012
Resolved
Repair hole in hull bottom shell plate in lazerette with a temporary steel doubler welded to the inside hull
Documentation › Logs/Records › Drug Test Records
Issued 15 May 2012
Resolved
MIS form not submitted by March 15 as required by 46 CFR part 16.500.
Documentation › Logs/Records › Drug Test Records
Issued 15 May 2012
Resolved
No copy of contract or proof of enrollment in Consortium as required by 46 CFR 16.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 14 October 2010
Resolved
Light was not functioning properly. Despite new battery, light continued to have a low intensity level and incorrect flashing.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 14 October 2010
Resolved
Pilot house extinguisher was hung on the incorrect bracket as per the manufactuer's standards.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 14 October 2010
Resolved
Both main diesel engines had exposed rotating machinery.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 October 2010
Resolved
Anchor light was burnt out and was replaced with a vertical filament bulb that did not have a UL 1104 stamp on it.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 14 October 2010
Resolved
One member, who is also a Master of the vessel, was not listed on the consortium list.
Engineering › Bilge Water Management System › Not Operational
Issued 2 October 2008
Resolved
Prove proper operation of bilge system to include pumping of void #2 (bow thruster compartment) with adequate pumping rate (50 gpm) IAW 46 CFR 182.25.
Stability › Weathertight Integrity › General
Issued 12 September 2008
Resolved
Replace six cracked windows forward main deck (bow).
Documentation › Logs/Records › Drug Test Records
Issued 11 June 2007
Resolved
Random drug testing was found to not be conducted in accordance with 46 CFR 16.230. Company currently enrolls new employees in its contracted drug testing consortium on a quarterly basis, rather than at the time of hiring.
Documentation › Logs/Records › Drug Test Records
Issued 11 June 2007
Resolved
Random drug testing was found to not be conducted in accordance with 46 CFR 16.230. Company currently is waiving random drug testing for some employees, based upon their participation in another unaffiliated company.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 20 October 2004
Resolved
Provide tidal current table.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 20 October 2004
Resolved
Repair cracked stanchion upper deck starboard aft.
Electrical › Electrical Distribution System (service)
Issued 7 August 2002
Resolved
Circuit Breakers for Band cirduits in the "main deck" panel located in engine room trunk do not match labels. Ensure 20 amp & 100 amp breakers are correctly sized for load. Provide single line diagram for this circuit LEGACY COMPONENT DESC: Circuit Breaker
Construction/Loadline › Hull
Issued 14 March 2002
Resolved
Attended vessel on blocks, conducted internal and external hull exam. Found wastage on port/starboard sides in the way of the galley and engine room. Starboard side longitudinals wasted in galley behind dish storage area, and engine room behind exhaust/venting fan. LEGACY COMPONENT DESC: Hull Plating
Electrical › Electrical Distribution System (service)
Issued 11 December 2001
Resolved
Distribution panel was missing cover in galley.
Documentation › Logs/Records
Issued 11 December 2001
Resolved
Failed to log monthly EPIRB checks.
Documentation
Issued 11 December 2001
Resolved
NOAA registration was expired on the EPIRB.
Accommodation/Occupational Safety › Medical/First Aid
Issued 11 December 2001
Resolved
Aspirin and ammonia inhalants expired in first aid kit.
Documentation
Issued 14 August 1995
Resolved
Post waste management plan.
Lifesaving
Issued 14 August 1995
Resolved
Provide high pressure cylinder storage for beverage service spare CO2 cylinders.
Construction/Loadline
Issued 14 August 1995
Resolved
Repair broken starboard rudder post support bracket.
Fire Fighting
Issued 14 August 1995
Resolved
Provide servicing procedures and certificate for galley deep fat fryer fixed dry chemical fire extinguishing system.
Electrical
Issued 25 August 1993
Resolved
REMOVE OR PROPERLY INSTALL THE POWER VENTILATOR LOCATED IN THE LAZARETTE, PORT SIDE.
Electrical
Issued 25 August 1993
Resolved
SEAL TOP OF LOWER SWITCH BOX IN WAY OF ENGINEROOM AFT BULKHEAD.
Fire Fighting
Issued 25 August 1993
Resolved
HORIZONTAL FIRE DOORS BETWEEN THE GALLEY AND THE MAIN DECK, AND THE MAIN DECK AND THE UPPER DECK SHALL TO BE MADE TO COMPLY WITH THE REQUIREMENTS OF46 CFR 72.05-25 (b)(9), 72.05-20(c), AND 111.99 IN ACCORDANCE WITH COMMANDANT (G-MVI) POLICY LETTER 15-93 DATED 13JUL93.
Electrical
Issued 25 August 1993
Resolved
REMOVE TEMPORARILY INSTALLED WELDER'S CABLE OUTLET FROM CIRCUIT BREAKER PANELBOX IN WAY OF ENGINEROOM ENTRANCE, PORT SIDE.
Electrical
Issued 25 August 1993
Resolved
INSTALL A "BLANK" IN THE CIRCUIT BREAKER PANEL IN WAY OF ENGINEROOM ENTRANCE, PORT SIDE.
Electrical
Issued 25 August 1993
Resolved
INSTALL A "BLANK" IN THE CIRCUIT BREAKER PANEL LOCATED AT THE FORWARD END, STARBOARD SIDE OF THE UPPER DECK.
Lifesaving
Issued 25 August 1993
Resolved
PROPERLY SECURE ALL PRESSURIZED GAS CYLINDERS.
Lifesaving
Issued 25 August 1993
Resolved
PROPERLY SECURE FREEZER IN WAY OF AFT MAIN DECK.
Electrical
Issued 25 August 1993
Resolved
PROPERLY WIRE FREEZER IN WAY OF AFT MAIN DECK.
Electrical
Issued 25 August 1993
Resolved
PROVIDE METAL CABLE SUPPORTS EVERY TWO FEET FOR WIRING RUNS IN GALLEY AND ENGINEROOM.
Electrical
Issued 25 August 1993
Resolved
RENEW DETERIORATED PORT SIDE BATTERY BOX IN THE ENGINEROOM.
Navigation
Issued 23 August 1990
Resolved
BRING UNDERWAY NAVIGATION LIGHTS IN COMPLIANCE WITH NAVIGATION RULES, RULE 20(B)
Lifesaving
Issued 10 May 1990
Resolved
PROVIDE ONE (1) WATER LIGHT IN GOOD CONDITION FOR ONE RING BUOY.
Engineering
Issued 10 May 1990
Resolved
PROVIDE AN APPROVED FOR MARINE USE TYPE FUEL FILTER TO EACH SIX (6) DIESEL ENGINES IN THE ENGINE ROOM.
Documentation
Issued 10 May 1990
Resolved
PROVIDE A VALID COMMUNICATION ACT SAFETY RADIO TELEPHONE CERTIFICATE ISSUEDBY FCC., PRIOR TO OPERATING IN SAN DIEGO BAY WITH PASSENGERS.
Electrical
Issued 17 December 1985
Resolved
PROVIDE AND INSTALL LOW OIL PRESSURE AND HIGH WATER TEMPERATURE SHUTDOWNS FOR BOTH SHIP SERVICE GENERATORS AND MAKE AVAILABLE FOR TEST.
Documentation
Issued 20 February 1985
Resolved
PROVIDE AND POST ON BOARD THE VESSEL'S TEMPORARY STABILITY LETTER, UPON RECEIPT FROM USCG TECHNICAL BRANCH, NEW YORK.
Unknown
Issued 20 February 1985
Resolved
THE TOTAL NUMBER OF PERSONS ALLOWED ON BOARD IS RESTRICTED TO NOT MORE THAN450 PERSONS PENDING COMPLETION OF STABILITY ANALYSIS.
Unknown
Issued 20 February 1985
Resolved
THE TOTAL NUMBER OF PERSONS ALLOWED ON THE BRIDGE DECK IS RESTRICTED TO NOT MORE THAN 126 PERSONS PENDING COMPLETION OF STABILITY ANALYSIS.
Casualty record · 1
9 April 2017Routine · role: Involved in a Marine Casualty · activity 6123241
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.