MAURY USCG vessel records Sign in
← All vessels

MARINER

MARINER is a 1984 freight ship. The Coast Guard has recorded 29 inspections since 1984, most recently in July 2012, along with 10 deficiencies and 2 operational controls.

Records from 1984 to 2012. Most recent: inspection, 24 July 2012.

Built
1984
Last inspected
24 July 2012
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8405232 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
240835
Flag
PANAMA
—
Maury page id
psix-240835

Inspections, by type

…with no type recorded24
Years with a record 21 calendar years (1984–2012)
The 29 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it9226 - Convention (Subpart B), Net Ton
15766 - Convention (Subpart B), Gross Ton
32207 - Displacement, Ton
26605 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 29

24 July 2012 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4382776
23 July 2012 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4384215
17 February 2011 Administrative Inspection · PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3944028
8 December 2009 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3646295
6 January 2006 ISPS II Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2561963
6 May 2005 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2345724
29 April 2005 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2345740
24 June 2003 Annual Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1825677
14 September 2000 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 282154
17 May 2000 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 277816
9 September 1999 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 432272
30 March 1997 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 402087
16 June 1996 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 392272
18 April 1996 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 390435
17 April 1995 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 377384
23 April 1994 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 366239
23 November 1992 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 354881
5 October 1991 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 346221
2 May 1991 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 464003
17 August 1990 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 338831
17 July 1989 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 331446
6 June 1988 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 323735
22 April 1987 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 315535
31 October 1986 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 498444
16 July 1986 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 310169
3 April 1986 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 307807
6 October 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 446743
17 June 1985 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 478547
13 December 1984 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 299485

Deficiency record · 10

Personnel › Certificates/Documents/Licenses
Issued 24 June 2003 Resolved
Second Engineer does not have Flag State Endorsement or proof of application for Flag State Endorsement. LEGACY COMPONENT DESC: License, Assistant Engineer
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 June 2003
Resolved 25 June 2003
Resolution: Received documentary proof of Flag State Endorsement for second engineer from Government of Malta.
Pollution Prevention/Response › Prevention Equipment
Issued 24 June 2003 Resolved
Sewage treatment plant air pump not operating properly. Instructed Master that sewage treatment plant can not be used in United States waters until system operates properly. LEGACY COMPONENT DESC: Marine Sanitation Device, Type II
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 June 2003
Resolved 24 June 2003
Resolution: The crew corrected the problem by introducing ship''''s service air into the system for the mixing of the chemicals and the sewage..
Fire Fighting
Issued 9 September 1999 Resolved
PROVIDE SERVICING CERTIFICATE FOR FOAM IN FIXED FIREFIGHTING SYSTEM, SOLAS 74 UNAMENDED II-2/9,10 and 15.
Condition: Unknown
Due 19 May 2000
Resolved 19 May 2000
Navigation
Issued 9 September 1999 Resolved
PROVIDE UPDATED AND CORRECTED NAVIGATION CHARTS,33CFR164.33.
Condition: Unknown
Due 9 September 1999
Resolved 9 September 1999
Navigation
Issued 18 April 1996 Resolved
Steering gear space did not have a non-skid surfrace nor a safety rail around the steering gear.
Condition: Unknown
Due 17 June 1996
Resolved 17 June 1996
Documentation
Issued 3 April 1986 Resolved
VESSEL FAILED TO HAVE POSTED OIL DISCHARGE PLACARD AS REQUIRED.
Condition: Unknown
Due 3 April 1986
Resolved 3 April 1986
Documentation
Issued 3 April 1986 Resolved
VESSELS OIL RECORD BOOK WAS NO KEPT IN ACCORDANCE WITH MARPOL 73/78 IMPROPER CODES WERE ENTERED FOR THE OPERATIONS CONDUCTED. HOWEVER VESSEL DID HAVE ENOUGH INFORMATION TO CORRECT THE OIL RECORD BOOK.
Condition: Unknown
Due 3 April 1986
Resolved 3 April 1986
Navigation
Issued 3 April 1986 Resolved
VESSEL HAS CHARTS 18521 53RD EDITION 1983 CHART 18523 41ST ED 1984 CHART 18524 21ST ED 1984 NONE OF THESE CHARTS HAD NO CORRECTIONS FROM NOTICE TO MARINERS PRIOR TO JANUARY 1986.
Condition: Unknown
Due 3 April 1986
Resolved 3 April 1986
Navigation
Issued 3 April 1986 Resolved
VESSEL DID NOT HAVE CURRENT EDITIONS OF TIDE AND TIDAL CURRENT TABLES FOR THE AREA TO BE TRANSITTED
Condition: Unknown
Due 3 April 1986
Resolved 3 April 1986
Navigation
Issued 3 April 1986 Resolved
VESSEL FAILED TO CONDUCT AND LOG A STEERING DRILL WITHIN 48 HOURS OF ENTERING A U. S. PORT, OR ON A REGULAR BASIS EVERY THREE MONTHS.
Condition: Unknown
Due 3 April 1986
Resolved 3 April 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.