← All vessels
BULK TRADER
Freight Ship · Bulk Carrier class · Built 1980s · USCG Heartland District (CGD-H) · Other hulls named BULK TRADER
BULK TRADER is a 1984 freight ship. The Coast Guard has recorded 27 inspections since 1984, most recently in February 2011, along with 26 deficiencies and 4 operational controls.
Records from 1984 to 2011. Most recent: inspection, 22 February 2011.
- Built
- 1984
- Last inspected
- 22 February 2011
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 26 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8309426 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
HPYS
240837
Flag
PANAMA
—
Maury page id
psix-240837
Inspections, by type
The 27 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it13370 - Simplified, Net Ton
13370 - Convention (Subpart B), Net Ton
23594 - Simplified, Gross Ton
23594 - Convention (Subpart B), Gross Ton
47863 - Displacement, Ton
40688 - Dead Weight, Ton
13370 - Convention (Subpart B), Net Ton
23594 - Simplified, Gross Ton
23594 - Convention (Subpart B), Gross Ton
47863 - Displacement, Ton
40688 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 27
22 February 2011
Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3949952
20 January 2011
ISPS III Exam · Ballast Water Examination · COE-Dockside · PII Safety Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3926601
3 September 2010
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3841411
1 September 2010
Ballast Water Examination · ISPS II Exam · Deficiency Check · PII Safety Exam · COE-Dockside
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3833463
30 June 2008
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3252780
17 July 2007
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2998278
6 July 2007
ISPS III Exam · PII Safety Exam · MARPOL Annex V Examination · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2985355
3 July 2007
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2982095
23 January 2007
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2854626
22 October 1999
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 433919
5 April 1999
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 427216
15 July 1998
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 417724
4 April 1998
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 414244
15 July 1997
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 405632
24 February 1996
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 388299
21 May 1995
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 378560
18 October 1994
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 511781
4 June 1992
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 531911
20 September 1991
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 346040
11 July 1990
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 338187
21 March 1989
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 329257
4 September 1987
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 318465
4 September 1986
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 533893
15 January 1986
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 306365
7 July 1985
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 500686
18 December 1984
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 299355
10 December 1984
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 299573
Deficiency record · 26
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 20 January 2011
Resolved
No change shall be made to the structural arrangement, machinery, or equipment without the sanction of the administration a hole was found in the OWS suction line with a temporary repair. Repair in accordance with the Administration. SOLAS 74 (2009 cons ed.) 1/11
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 20 January 2011
Resolved
The vessels marine sanitation device shall be free of defects that would allow toxic substances to escape to the interior of the vessel. The marine sanitation device had multiple holes in the tank top which could possibly allow toxic gases into the engine room. Repair in accordance with the administration. 33CFR159.95
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 3 September 2010
Resolved
The Echo Depth Sounder was report not operational.
Engineering › Steering Gear System › Follow-up Assembly
Issued 1 September 2010
Resolved
0936- Steering Gear-It was observed that while testing the steering gear assembly that when operating on system 1 with both motors from 30 degrees port to 35 degrees starboard that the steering assembly would slow down and stop actuating as it reached 27 degrees to starboard. SOLAS 74 II/I-29
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 1 September 2010
Resolved
1581-Rudder Angle Indicator-It was observed that the rudder angle indicator had a 13 degree difference between the degree reading at the rudder stock and what is being displayed on the bridge. SOLAS 74 II/I-29
Engineering › Freshwater System (piston cooling) › Drainage
Issued 1 September 2010
Resolved
1410-Propulsion, Main Engine-It was observed that the piston cooling water tank has excessive lube oil in it. The crew has installed a manual skimming system to recover the oil to the bilge oil holding tank. SOLAS 74 I/II
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 1 September 2010
Resolved
0720-Fire Fighting Equipment-It was observed on the fuel oil feed line from the fuel oil tank to the emergency fire pump that at the intersection of the deck and the fuel line that there was an epoxy repair that was leaking fuel oil. SOLAS 74 I/11
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 1 September 2010
Resolved
2199-Other (MARPOL Operational Def.) It was observed that the crew has installed an in line Weir Separator from the bilge oil holding tank to the waste oil holding tank at the waste oil holding tank flat. Request clarification from Certificate Issuing Authority as to the acceptance of the Weir Separator installation at the waste oil holding tank. MARPOL 73/78 I/14
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 1 September 2010
Resolved
2199-(MARPOL Operational Def.) It was observed that the crew has installed an in line Weir Separator from the stuffing box from the main diesel engine to the bilge oil holding tank. Request clarification from Certificate Issuing Authority as to the acceptance of the crew installed Weir Separator in line to the bilge oil holding tank. MARPOL 73/78 I/14
Engineering › Diesel Engine (propulsion-direct drive) › Charge Air Cooling
Issued 1 September 2010
Resolved
1410-Propulsion main engine-It was observed that there was installed drain valves on the bottom of the scavenger air tank and that when actuated there was an excessive amounts of waste oil released onto the deck. Request clarification from Certificate Issuing Authority to the acceptance of the crew installed drain valves on the scavenger air tanks and excessive amounts of waste oil. SOLAS 74 I/11
Communications › Radio Communications › Satellite Communications Capability
Issued 1 September 2010
Resolved
1699-Other-Radio-It was observed that while conducting the bridge/nav. safety exam that the GMDSS installation would only receive and not send any transmissions. Conduct repairs to the satisfaction of Certificate Issuing Authority. SOLAS 74 am IV/14
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 1 September 2010
Resolved
1575-Ecosounder-It was observed that the ships installed echo depth sounder display panel and recorder has failed. Conduct repairs to the satisfaction of Certificate Issuing Authority. SOLAS 74am V/19
Navigation › Collision/Grounding Avoidance › Radar
Issued 1 September 2010
Resolved
1530-Radar-It was reported that the #2 radar has failed. Conduct repairs to the satisfaction of Certificate Issuing Authority. SOLAS 74 am V/19
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 1 September 2010
Resolved
2099-Other(SOLAS Operational Def.)-It was observed that the crew has installed a non class approved flex hose transferring sewage from the deck overboard discharge tot he aft peak ballast tank. Request clarification from Certificate Issuing Authority as to acceptance of the installation and provide for ensuring that the aft peak is properly cleaned. SOLAS 74 I/11
Fire Fighting › Fire Main › Condition
Issued 30 June 2008
Resolved
While inspecting the boatswain store it was noted that the port side anchor wash piping had severe rust bubbling and a large amount of running rust, class to attest to the condition of piping.
Fire Fighting › Fire Main › Material
Issued 6 July 2007
Resolved
Fire main piping located in forecastle space is soft patched. It appears to have been in this condition for a long time! Report this item to DPA and repair to satisfaction of attending class surveyor.
Engineering › Steam Boiler (auxiliary/waste heat) › Piping
Issued 6 July 2007
Resolved
Boiler filling piping located in upper engine room space is clamped patched. Report this item to DPA and repair to satisfaction of attending class surveyor.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 6 July 2007
Resolved
Fire Control Plan (FCP) , does not address primary firefighting system that ids located in #2 Paint locker (drenching system). It only shows portable foam extinguisher. properly mark FCP to satisfaction of vessels class surveyor.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Nozzles
Issued 6 July 2007
Resolved
Vessels fixed firefighting drenching system discharge outlets (located in vessels paint lockers), appears to have incorrectly installed heads. It has a wet type sprinkler head installed, vice a drenching type head (dry type)
Engineering › Steering Gear System › Rudder Bearing
Issued 6 July 2007
Resolved
Bridge control auxiliary steering system (when tested by Marine Inspector) is locking up when movement tested from hard port to hard stbd (and vice versa). Correct the same.
Navigation › Collision/Grounding Avoidance › Automatic Radar Plotting Aid (ARPA)
Issued 23 January 2007
Resolved
Automatic Identification System Pilot Plug not available/ missing from bridge. Deficiency to be rectified prior to next U.S. port after sailing foreign.
Fire Fighting › Fire Main › Condition
Issued 22 October 1999
Resolved
FIRE MAIN WASTED AT HOLED LOCATED ON STBD SIDE MAIN DECK AT CARGO HATCH 3. MAKE PERMANENT REPAIRS PRIOR TO 22NOV99.
Fire Fighting
Issued 15 July 1997
Resolved
Renew as original the starboard side, main deck fire main between #2 and #3cargo hold in way of temporary doubler._x001C_ Per SOLAS 74 (Unamended) II-2/5(e)_x001C_ _x001C_
Lifesaving
Issued 15 July 1997
Resolved
Replace all expired medications in the ship's hospital with current medications in a language understood by the crew._x001C_ Per ILO 147/PWSA 33 USC 1223(b)
Fire Fighting
Issued 15 July 1997
Resolved
Renew as original the starboard side, main deck fire main, aft of the #5 cargo hold._x001C_ Per SOLAS 74 (Unamended) II-2/5(e)_x001C_ _x001C_
Lifesaving
Issued 21 May 1995
Resolved
PROVIDE WEAK LINKS ON PORT & STBD LIFERAFTS INLINE TO ENSURE PROPER RELEASEIN FLOAT FREE SITUATION AND PROPERLY RIG SEA PAINTERS.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.