MAURY USCG vessel records Sign in
← All vessels

COLUMBIA

COLUMBIA is a 1983 offshore supply vessel. The Coast Guard has recorded 36 inspections since 1991, most recently in September 2020, along with 27 deficiencies, 1 operational control and 1 casualty investigation in 2005.

Records from 1991 to 2020. Most recent: inspection, 25 September 2020.

Built
1983
Last inspected
25 September 2020
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDF9791
241644
Flag
UNITED STATES
366742920, 367118460 (licence lapsed)
Maury page id
psix-241644

Inspections, by type

…with no type recorded3
Years with a record 23 calendar years (1991–2020)
The 36 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it46 - Simplified, Net Ton
58 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDD2679MMSI 367118460 · expired · compulsorily equipped · granted 1 June 2006, cancelled 6 August 2016
WAH9206MMSI 366742920 · expired · compulsorily equipped · granted 15 January 1998, cancelled 19 February 2005
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 36

25 September 2020 Administrative Inspection
Administrative · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7067151
26 April 2016 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5863112
8 May 2014 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4852804
10 January 2012 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4221490
16 February 2010 Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3693236
19 March 2009 Annual Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3430444
12 February 2008 Deficiency Check · Internal Structural Exam · Administrative Inspection · Annual Inspection · Hull Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3143348
23 March 2006 COI Inspection · Hull Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2606872
30 July 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2457122
23 June 2005 Annual Inspection · Damage Survey
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2399964
11 March 2005 Administrative Inspection
Administrative · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2308365
7 March 2005 Administrative Inspection
Administrative · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2305143
14 February 2005 Damage Survey
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2292277
5 March 2004 Annual Inspection · Hull Examination
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2018601
10 September 2003 Damage Survey
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1903349
28 March 2003 Examination of Repairs · Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1764245
30 April 2002 Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1610869
6 February 2001 COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1454890
7 August 2000 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1413784
17 May 1999 Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1386464
14 May 1999 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1440133
26 June 1998 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1472120
4 April 1997 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1435889
12 March 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 33751
15 February 1996 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1446299
1 February 1996 Re-Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1442350
31 March 1995 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1422482
23 February 1995 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 839044
11 July 1994 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 867774
10 February 1994 Re-Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1356514
1 April 1993 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1441998
29 March 1993 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 222027
27 October 1992 Inclining Experiment
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1266236
18 February 1992 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1270843
17 January 1992 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1317731
15 February 1991 Hull Examination · Initial Certification
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 910236

Deficiency record · 27

Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 26 April 2016 Resolved
Provide life float light operation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 May 2016
Resolution: Vessel renewed life float light, tested sat.
Stability › Watertight Integrity › General
Issued 26 April 2016 Resolved
Provide watertight hatches to main deck.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 May 2016
Resolution: Vessel made maintenance hatch watertight with proper gaskets, all sat.
Stability › Weathertight Integrity › General
Issued 26 April 2016 Resolved
Provide weather tight gasket to escape hatch in galley.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 May 2016
Resolution: Vessel made hatch weather tight with proper gaskets, all sat.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 26 April 2016 Resolved
Provide machinery guards to port and stbd engine. Prior to operation.
Action required: 705 - Other - as specified
Resolved 4 May 2016
Resolution: Vessel provided machinery guards for port and stbd engine, all sat.
Electrical › Lighting (emergency) › Lighting Branch Circuit
Issued 26 April 2016 Resolved
Provide operation of emergency lighting in presence of marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 May 2016
Resolution: Vessel renewed batteries for emergency lighting, tested sat.
Operations/Management › Drills/Instruction › Making Voice Radio Distress Call
Issued 26 April 2016 Resolved
Provide vessel specific emergency broadcast placard.
Due 3 May 2016
Resolved 4 May 2016
Resolution: Vessel updated emergency broadcast placard, all sat.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 26 April 2016 Resolved
Provide escape exit labels to engine room escape hatch.
Due 3 May 2016
Resolved 4 May 2016
Resolution: Vessel provided proper markings, all sat.
Documentation › Logs/Records › Logbook (official)
Issued 26 April 2016 Resolved
Provide satisfactory drills in presence of marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 May 2016
Resolution: Vessel properly instructed and demonstrated proper logging of emergency drills, all sat.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 8 May 2014 Resolved
Starboard Main Engine missing exhaust lagging.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 May 2014
Resolution: Exhaust lagging replaced.
Electrical › Lighting (service) › Outlet Box
Issued 8 May 2014 Resolved
Wire installation for navigation lights have corroded junction boxes and exposed wire connections.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 May 2014
Resolution: Vessel navigational lights rewired to new junction boxes.
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 May 2014 Resolved
Dead end wires found in engine room and an extension cord used as permanent wiring for the battery charger.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 May 2014
Resolution: Dead end wires pulled, extension cord removed and an outlet installed near charger.
Navigation › Piloting/Steering › Marine Charts
Issued 8 May 2014 Resolved
Charts onboard not up to date.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 May 2014
Resolution: New charts onboard.
Construction/Loadline › Hull › Hull Plating
Issued 14 February 2005 Resolved
Vessel is to proceed directly to Empire LA to complete permanent repairs to hull. During transit vessel will be equipped with an independent bilge pump and shall have an escort vessel. Prior to further operations repairs to hull are to made to the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Due 12 April 2005
Resolved 23 June 2005
Construction/Loadline › Hull
Issued 28 March 2003 Resolved
Crop and renew improper insert in way of starboard rudder tube housing. LEGACY COMPONENT DESC: Bottom Plating
Condition: Improper Installation
Due 2 May 2003
Resolved 22 April 2003
Electrical › Electric Generation Source (service)
Issued 28 March 2003 Resolved
Provide and Install approved/Proper fuel hoses on SSDG. In accordance with 46CFR182.455 (a) (iii) and 46CFR182.720 (e)
Due 2 May 2003
Resolved 22 April 2003
Electrical › Electric Generation Source (service)
Issued 28 March 2003 Resolved
Install Hertz, Amps and Volt meters on SSDG.
Due 2 May 2003
Resolved 22 April 2003
Construction/Loadline
Issued 28 March 2003 Resolved
Repair or replace the wasted sections of the external housing on all 3 jacking gear speed reducers.
Due 2 May 2003
Resolved 22 April 2003
Lifesaving
Issued 14 May 1999 Resolved
PROVIDE CG APPROVED RESCUE BOAT AND/OR ADEQUATE RESCUE PLATFORM IN ACCORDANCE WITH THE EIGHTH COAST GUARD DISTRICTS LETTER 16113 DATED 12 NOVEMBER 1998. COPY PROVIDE TO VESSEL'S MASTER.
Condition: Unknown
Due 14 May 1999
Resolved 14 May 1999
Construction/Loadline
Issued 1 February 1996 Resolved
MAKE PERMANENT REPAIRS (GOUGE/REWELD) TO PORT SIDE BULWARK AMIDSHIP.
Condition: Unknown
Due 15 February 1996
Resolved 16 February 1996
Accommodation/Occupational Safety
Issued 1 February 1996 Resolved
PROVIDE BUNK LIGHTS, PERMANENTLY INSTALLED FOR ALL BUNKS, 46CFR111.75-15(d)
Condition: Unknown
Due 15 February 1996
Resolved 16 February 1996
Engineering
Issued 1 February 1996 Resolved
REPLACE RUBBER HOSES FOR BOTH PORT AND STARBOARD MAIN ENGINE STUFFING BOXES.
Condition: Unknown
Due 15 February 1996
Resolved 16 February 1996
Lifesaving
Issued 1 February 1996 Resolved
PROVIDE ANOTHER WEAK LINK WITH TAG RATING AND INSTALL ON LIFEFLOAT._x001C_
Condition: Unknown
Due 15 February 1996
Resolved 16 February 1996
Navigation
Issued 1 February 1996 Resolved
OBTAIN FOLLOWING FEDERAL REGULATIONS AND MAINTAIN ONBOARD VESSEL: 46CFR41- 69, 46CFR 90-139, 33CFR 01-199.
Condition: Unknown
Due 15 February 1996
Resolved 16 February 1996
Documentation
Issued 10 February 1994 Resolved
PROVIDE ONBOARD A VALID COAST GUARD ISSUED STABILITY LETTER.
Condition: Unknown
Due 10 February 1994
Resolved 10 February 1994
Documentation
Issued 10 February 1994 Resolved
PROVIDE ONBOARD A COAST GUARD APPROVED AND STAMPED OPERATING MANUAL.
Condition: Unknown
Due 10 February 1994
Resolved 10 February 1994
Documentation
Issued 15 February 1991 Resolved
SUBMIT FOR REVIEW AN OPERATING MANUAL (3 COPIES) TO [name withheld] TOFORWARD TO COMMANDANT (G-MSC) THIS MANUAL SHALL INCLUDE LOCATIONS AND REPAIR PROCEDURES FOR ALL HIGH TENSILE STEEL USED IN VESSEL CONSTRUCTION.
Condition: Unknown
Due 15 February 1991
Resolved 15 February 1991
Documentation
Issued 15 February 1991 Resolved
SUBMIT FOR REVIEW THE FOLLOWING PLANS TO [name withheld] TO FORWARD TOCOMMANDANT (G-MSC): GENERAL ARRANGEMENTS INBOARD AND OUTBOARD PROFILES, LEG STRUCTURES JACKING TOWER STRUCTURES, HYDAULIC SYSTEMS AND STABILITY CALCULATIONS.
Condition: Unknown
Due 15 February 1991
Resolved 15 February 1991

Casualty record · 1

30 July 2005Significant Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 2457122
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

ALLIED ELEVATOR NO. 2 (2005). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.