GINGA KITE is a 2000 tank ship. The Coast Guard has recorded 19 inspections since 2001, most recently in May 2023, along with 6 deficiencies and 4 operational controls.

Records from 2001 to 2023. Most recent: inspection, 8 May 2023.

Built
2000
Last inspected
8 May 2023
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9228291 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9V6437
Flag
SINGAPORE
—
Maury page id
psix-24191

Inspections, by type

…with no type recorded6
Years with a record 11 calendar years (2001–2023)
The 19 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it25901 - Displacement, Ton
19997 - Dead Weight, Ton
12044 - Convention (Subpart B), Gross Ton
12044 - Regulatory (Subpart C or D), Gross Ton
6194 - Convention (Subpart B), Net Ton
6194 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 19

8 May 2023 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7683877
5 May 2023 PSC B · Administrative Inspection · COC-CHEM Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7680221
29 September 2010 Ballast Water Examination · COC-CHEM Renew · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3859344
24 February 2009 ISPS II Exam · COC-CHEM Annual
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3422346
29 March 2008 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3174980
6 March 2008 COC-CHEM Renew · ISPS II Exam · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3159718
26 April 2007 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2916098
24 July 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2723770
24 July 2006 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2725564
15 July 2006 Ballast Water Examination · ISPS II Exam · COC-CHEM Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2713405
5 July 2005 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2415188
29 June 2005 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2407995
23 June 2005 COC-CHEM Renew · ISPS III Exam · Ballast Water Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2400007
18 April 2005 Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2336991
19 October 2004 PII Safety Exam · ISPS II Exam
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2224010
15 May 2003 Certificate of Compliance · Ballast Water Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1794126
4 October 2002 Certificate of Compliance
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1685853
14 April 2001 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 289117
14 April 2001 Letter of Compliance (Initial/Renewal)
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1062961

Deficiency record · 6

Personnel › Certificates/Documents/Licenses › License, Chief Engineer
Issued 15 July 2006 Resolved
Chief Engineer license has been issued for a period greater than 5 years. Prior to departure, provide flag state attestation to the validity of his license.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 July 2006
Resolution: Received satisfactory Flag State attestation letter.
Fire Fighting › Fixed Deck Foam System › Main Control Station
Issued 23 June 2005 Resolved
The operating instructions for the Foam need to be incorporated into the Fire Training Manual. Reference SOLAS Amendment 2000 II-2 Reg. 15.
Due 7 July 2005
Resolved 29 June 2005
Resolution: Instructions for the foam have been added to the fire training manual.
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 23 June 2005 Resolved
The [name withheld] needs to conduct Ballast Water Training and record the attendees into in the Ballast Water Manual.
Due 7 July 2005
Resolved 29 June 2005
Resolution: The [name withheld] conducted training as required by section 7 of the Ballast Water Manual.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 23 June 2005 Resolved
The Cargo and Bunker transfer procedures were not in accordance with the CFR'S.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 June 2005
Resolved 23 June 2005
Resolution: Samples of both transfer procedures were given to the Master, [name withheld] and [name withheld] conducted training on each of the procedures and recommended they incorporate them into the company operating procedures.
Deck/Cargo › Vapor Control Systems › Vapor Recovery Unit
Issued 23 June 2005 Resolved
Vapor training needs to be conducted by a company representative in order to meet the requirements of 33 CFR part 39 and ISGOTT part 7.
Due 7 July 2005
Resolved 29 June 2005
Resolution: The [name withheld] was given Vapor Control training by the company on 16 November 2004.
Electrical › Electric Generation Source (service) › Neutral Ground
Issued 23 June 2005 Resolved
The company needs to provide written proof that the electrical matting meets the requirements of 29 CFR 1910, SOLAS II-1 Reg. 40 and 45.
Due 7 July 2005
Resolved 29 June 2005
Resolution: The Classification Society (NKK) sent a letter stating that the rubber matting on board meets the SOLAS and 29 CFR requirements.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.