FISHIN XPRESS

FISHIN XPRESS is a 1983 passenger vessel (inspected). The Coast Guard has recorded 90 inspections since 1985, most recently in August 2025, along with 271 deficiencies and 1 operational control.

Records from 1985 to 2025. Most recent: inspection, 13 August 2025.

Built
1983
Last inspected
13 August 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCZ9781
242041
Flag
UNITED STATES
367463930, 368305080
Maury page id
psix-242041

Inspections, by type

…with no type recorded8
Years with a record 38 calendar years (1985–2025)
The 90 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)46.7 ft × 15.2 ft × 6.2 ft
Registered tonnagegross 40 / net 27
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDMR YACHTS INC. · ARUNDEL, ME, UNITED STATES · built 1983
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portFORT MYERS BEACH, FL
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 26 August 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it27 - Regulatory (Subpart C or D), Net Ton
40 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDN7078MMSI 368305080 · active · compulsorily equipped · granted 30 March 2023, expires 30 March 2033
WDN5889MMSI 367463930 · active · compulsorily equipped · granted 26 January 2023, expires 26 January 2033 · licensed under a name not among this hull’s recorded names (not shown)
WCZ9781MMSI 367463930 · expired · voluntarily equipped · granted 17 August 2010, cancelled 10 October 2020 · licensed under a name not among this hull’s recorded names (not shown)
WAJ6864MMSI not assigned · expired · voluntarily equipped · granted 31 March 1995, cancelled 21 May 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 90

13 August 2025 Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8205403
21 August 2024 Annual Inspection · Hull Examination · Examination of Repairs
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7985299
31 May 2023 Deficiency Check · COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7700515
24 January 2023 Hull Examination · Drydock Exam · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7627686
19 January 2023 COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7620717
29 March 2022 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7420571
29 January 2021 Administrative Inspection · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7133219
25 January 2021 Administrative Inspection · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7130623
20 April 2020 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6941458
18 March 2019 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6644853
6 March 2019 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6637513
13 December 2018 Examination of Repairs · Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6597424
3 May 2018 Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6405113
23 February 2018 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6360615
20 April 2017 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6129374
21 February 2017 Administrative Inspection · COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6091926
17 January 2017 Administrative Inspection · Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6072295
3 March 2016 DAPI Audit · Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5828198
4 February 2016 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5809758
14 February 2012 COI Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4231998
23 February 2011 Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3937030
1 March 2010 Deficiency Check · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3677855
12 May 2009 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3472712
15 April 2009 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3373958
18 February 2009 Hull Examination · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3373955
26 February 2008 Deficiency Check · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3145812
16 April 2007 COI Inspection · Deficiency Check · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2902451
26 February 2007 Hull Examination · Deficiency Check · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2876495
23 May 2006 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2657113
22 May 2006 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2655627
20 September 2005 Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2497320
28 March 2005 Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2321520
14 February 2005 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2292533
4 October 2004 Administrative Inspection · Plan Review "T" Boat · Damage Survey
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2212736
11 February 2004 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2005036
11 August 2003 Plan Review "T" Boat
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1873489
10 July 2003 In-Service Inspection · Deficiency Check · Administrative Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1841866
6 May 2003 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1798273
22 April 2003 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1784120
22 April 2003 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1798247
3 January 2003 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1725009
17 September 2002 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1676576
17 May 2002 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1616503
12 September 2001 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1072428
14 May 2001 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1065480
4 January 2001 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 825337
21 September 2000 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1053680
20 July 2000 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1051732
3 May 2000 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1049557
6 May 1999 Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1369167
29 April 1999 Inclining Experiment
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1468064
23 February 1999 Plan Review "T" Boat
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1121644
24 December 1998 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 807397
14 April 1998 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1126761
3 March 1998 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1124519
17 February 1998 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1460165
5 May 1997 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1453367
14 April 1997 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1098186
31 March 1997 COI Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1390487
8 April 1996 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1404150
3 April 1995 Re-Inspection · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1454184
16 February 1995 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1394276
3 May 1994 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 858145
18 April 1994 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1168652
22 November 1993 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 669126
23 October 1993 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 82926
30 April 1993 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1148454
16 February 1993 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1150576
11 September 1992 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 936717
2 September 1992 Drydock Extension
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1259111
14 April 1992 Re-Inspection · Inclining Experiment
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1267925
6 May 1991 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1217926
18 April 1991 Deficiency Check · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 900015
13 February 1991 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1232037
20 September 1990 Drydock Extension
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1222876
8 May 1990 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1235139
23 April 1990 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 913378
15 November 1989 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1224102
31 August 1989 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 900633
27 April 1989 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1030611
28 March 1989 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1349211
26 April 1988 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1042430
4 April 1988 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 991744
22 February 1988 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1335294
1 July 1987 Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1321061
27 May 1987 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1027327
29 September 1986 Credit Drydock · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1006158
16 April 1986 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1306825
29 April 1985 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1285625
22 February 1985 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 978474

Deficiency record · 271

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 May 2023 Resolved
Starboard rudder stuffing box is excessively leaking. Repack/repair to mitigate water ingress to satisfaction of attending marine inspector. 46 CFR 182.200
Action required: 60 - Rectify deficiencies prior to movement
Due 31 May 2023
Resolved 5 June 2023
Resolution: Stuffing box was adequately repaired and leak was mitigated.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 19 January 2023 Resolved
Vessels operating on an Oceans route must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Vessel had no fire detection in accommodation space or operating station.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 February 2023
Resolved 10 February 2023
Resolution: MI observed smoke detectors installed and UL 217 rated.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 19 January 2023 Resolved
Stations in the maritime service must be licensed by the FCC either individually or by fleet. Vessel did not provide FCC Station Authorization. Limited to within 1000' of shore.
Action required: 705 - Other - as specified
Resolved 26 January 2023
Resolution: Received copy of Station Authorization Certificate.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 19 January 2023 Resolved
No marine employer shall engage or employ any individual to serve as a crewmember unless the individual passes a chemical test for dangerous drugs for that employer. Drug consortium enrollment letter indicated no proof of negative test. Provide evidence of negative drug test/satisfactory enrollment in consortium for master and crew prior to passenger operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 February 2023
Resolution: Received updated consortium list.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 19 January 2023 Resolved
Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Rotten wood was found in "tank room" overhead structural member. Submit repair proposal within 30 days.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 February 2023
Resolved 8 February 2023
Resolution: Received pictures of repaired deck beam.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 19 January 2023 Resolved
Each vessel that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. The hydrostatic release on the EPIRB was expired. Vessel is limited to operation within 3 miles from shore.
Action required: 705 - Other - as specified
Resolved 20 January 2023
Resolution: New hydrostatic release installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 January 2023 Resolved
Fuel lines must be effectively secured against excessive movement and vibration by the use of soft nonferrous metal straps which have no sharp edges and are insulated to protect against corrosion. Fuel line on port side of "tank room" was missing a bracket.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 February 2023
Resolved 3 February 2023
Resolution: Received photo of replaced bracket.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 January 2023 Resolved
Electrical equipment used a machinery space must be dripproof. Batteries in vessel machinery spaces did not have sufficient covers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 February 2023
Resolved 24 January 2023
Resolution: Inspectors observed covers in place on batteries.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 January 2023 Resolved
Rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passengers or crew. The top rail at the embarkation station did not have a bolt to keep it in place.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 February 2023
Resolution: Received photo from vessel rep showing bolt in place.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 19 January 2023 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Vessel's starboard navigation running light was inoperable. Vessel is limited to daytime operations.
Action required: 705 - Other - as specified
Resolved 20 January 2023
Resolution: Picture of functional running light
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 January 2023 Resolved
All cable and wire must be installed with metal supports spaced not more than 610 millimeters (24 inches) apart, and in such a manner as to avoid chafing and other damage. Electrical cable in "tank room" was missing a bracket.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 February 2023
Resolved 3 February 2023
Resolution: Received photo of replaced bracket.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 March 2022 Resolved
Immediately after the addressing of resultant safety concerns, the owner, master, or person in charge of a vessel involved in a marine casualty shall notify the nearest Sector Office, Marine Inspection Office, or Coast Guard Group Office whenever a vessel is involved in a marine casualty consisting of: loss of main propulsion or primary steering, or any associated component or control system. Vessel was discovered to have a ruptured oil cooler without notification to Sector Mobile Inspection office. Repair or replace STBD engine. 46 CFR 185.202
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 January 2023
Resolution: Engine repairs complete.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 29 March 2022 Resolved
he Certificate of Inspection and any SOLAS Certificates must be posted under glass or other suitable transparent material, such that all pages are visible, in a conspicuous place on the vessel where observation by passengers is likely. If posting is impracticable, such as in an open boat, the certificates must be kept on board in a weathertight container readily available for use by the crew and display to passengers and others on request. Vessel was found with expired COI posted. Post most up to date and complete COI. 46 CFR 176.302
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2023
Resolution: Issued temporary COI, new COI routed.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 29 January 2021 Resolved
Commercial vessel equipped with radio communications must have a FCC station license
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2021
Resolved 9 February 2021
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 29 January 2021 Resolved
Vessels are required to provide Coast Guard approved first aid kit. Vessel's first aid kit is expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2021
Resolved 18 February 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 20 April 2020 Resolved
Vessel must comply with the applicable requirements for any radio and EPIRB installations, including the requirements for a station license and installation certificates to be issued by the FCC as set forth in 47 CFR 80. Vessels radio telephony safety certificate has expired, review certificate and provide copy to marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2020
Resolved 18 May 2020
Resolution: Vessel obtained new FCC Radiotelephony Safety Certificate effective until MAY2025
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 12 March 2019 Resolved
Failed to provide fire exinguishing servicing reports. Provide reports once serviced.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2019
Resolution: Provided servicing reports of fire extinguishing systems.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 12 March 2019 Resolved
EPIRB not availalable for inspection. Updated NOAA registration not available. Provide EPIRB for inspection and vaild NOAA registration.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2019
Resolution: Provided EPIRB for inspection and valid NOAA registration.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 12 March 2019 Resolved
Stowage of lifefloats not in accordance with 46 CFR 180.137. Arrange lifefloats in accordance with regulations.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2019
Resolution: Arranged lifefloats IAW 46 CFR 180.137
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 5 March 2018 Resolved
Replace PVC pipe with non-metallic hose IAW 46 CFR 182.520
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 April 2018
Resolved 3 May 2018
Resolution: PVC pipe replaced with proper hose.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 5 March 2018 Resolved
Place current COD on board IAW 46 CFR 67
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 April 2018
Resolved 6 April 2018
Resolution: New owner vessel COD has been provided.
Lifesaving › Lifefloat › Platform
Issued 5 March 2018 Resolved
Properly tie lifefloats together IAW 46 CFR 180.137
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 April 2018
Resolved 3 May 2018
Resolution: Life floats tied together properly.
Communications › Radio Communications › VHF Radiotelephone
Issued 5 March 2018 Resolved
Link GPS to DCS capable radio and program MMSI number IAW 46 CFR 185.402
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 April 2018
Resolved 3 May 2018
Resolution: DSC and GPS installed to VHF radio.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 14 March 2017 Resolved
Ensure original and current certificate of documentation is onboard vessel.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 March 2017
Resolution: Provided the original document
Communications › Radio Communications › EPIRB
Issued 14 March 2017 Resolved
Provide current EPIRB registration.
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 April 2017
Resolved 17 March 2017
Resolution: Registered EPIRB
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 14 March 2017 Resolved
Fit first aid kit with ammonia inhalant, tourniquet, and ophthalmic ointment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 April 2017
Resolved 20 April 2017
Resolution: New med kit purchased.
Engineering › Bilge Water Management System › Pump
Issued 14 March 2017 Resolved
Ensure portable bilge suction operates.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 April 2017
Resolved 20 April 2017
Resolution: New hand pump purchased.
Operations/Management › Drills/Instruction › Not Conducted
Issued 14 March 2017 Resolved
Ensure proper documentation and description for drills and training.
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 April 2017
Resolved 14 March 2017
Resolution: Logged all drills and instruction for the day.
Electrical › Electric Generation Source (service) › Generator
Issued 22 March 2016 Resolved
Generator needs to meet TIER III requirement or provide paper work that newly installed generator already does.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 March 2017
Resolved 20 April 2017
Resolution: Generator replaced with Tier III.
Documentation › Certificates/Documents › Stability Letter
Issued 22 March 2016 Resolved
Stability test form found and reduced upper deck to 19 people from 22 till stability letter is issued or found.
Condition: Invalid
Action required: 705 - Other - as specified
Due 12 April 2016
Resolved 6 April 2016
Resolution: Issued new stability addeneum letter authorizing 19 psgrs on upper deck.
Engineering › Fuel Oil Service System › Hose
Issued 7 March 2016 Resolved
Port fuel branch line, just off fuel tank had a broken male pressure fitting. Replace fitting.
Condition: Invalid
Action required: 705 - Other - as specified
Due 22 March 2016
Resolved 22 March 2016
Documentation › Certificates/Documents › Certificate of Inspection
Issued 24 February 2016 Resolved
Original COI was not posted and was not available. Post original COI, as per 46 CFR 176.302.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2016
Resolved 7 March 2016
Resolution: COI Posted.
Documentation › Certificates/Documents › Stability Letter
Issued 24 February 2016 Resolved
Stability letter was not posted at operating station; it was not on vessel. Post stability letter at operating station, as per 46 CFR 176.306.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2016
Resolved 22 March 2016
Resolution: Stability letter was posted but was wrong letter. Sector Mobile is working with owner to rectify.
Fire Fighting › Fire Pumps › Arrangement
Issued 24 February 2016 Resolved
Fire pump was recently replaced and was not fully/properly installed and secured in place. Properly install fire pump as per 46 CFR 181.10-1 (OLD T)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2016
Resolved 22 March 2016
Resolution: This was not a fire pump it is only a wash down pump and working properly.
Stability › Weathertight Integrity › General
Issued 24 February 2016 Resolved
Doors to accommodation space freely flapped open and were not weathertight. Make doors weathertight, and not flap open, as per 46 CFR 171.124(d) OLD S
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2016
Resolved 7 March 2016
Resolution: Doors secured and made weathertight.
Stability › Watertight Integrity › General
Issued 24 February 2016 Resolved
Rudder posts leaked excessively while underway for drills. Repair/adjust to minimize water intrusion, as per 46 CFR 182.30-1 (OLD T)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2016
Resolved 22 March 2016
Resolution: Rudder post bearing changed out, leak fixed.
Stability › Watertight Integrity › General
Issued 24 February 2016 Resolved
Starboard shaft log leaked while underway for drills. Repair/adjust to minimize water intrusion as per 46 CFR 182.05-1 (OLD T)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2016
Resolved 7 March 2016
Resolution: Repair all Sat.
Communications › Alarms/Indicators › Bilge Alarm
Issued 24 February 2016 Resolved
Rudder space bilge pump high water level alarm not audible. Repair alarm, as per 46 CFR 182.115(d) then 46 CFR 182.530
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2016
Resolved 7 March 2016
Resolution: Repaired bilge pump high water level alarm.
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 February 2016 Resolved
Dead-ended wires, non-marine type wires, improperly spliced wires, and burnt/damaged wires found throughout vessel (under operating station, outside pilot house, outside main deck house, in accomodation space, in forward V space, in engine room, in tank room, and in rudder room). Properly repair damaged wires and remove or cap and enclose all dead-ended wires as per 46 CFR 183.01-15
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2016
Resolved 7 March 2016
Resolution: Repair all Sat.
Stability › Watertight Integrity › General
Issued 24 February 2016 Resolved
Access covers to fuel shut-offs and fuel fill piping were broken and not watertight. Replace to make watertight, as per 46 CFR 171.124(a) (OLD S)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2016
Resolved 7 March 2016
Resolution: Covers replaced
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 24 February 2016 Resolved
Exhaust supports were wood and broken. Replace with non-combustible supports as per 46 CFR 182.20-15 and 182.15-15 (OLD T)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2016
Resolved 22 March 2016
Resolution: Installed metal brackets.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 24 February 2016 Resolved
Rescue ladder was unable to be taken off bracket due to new sign on side of vessel. Reposition for ease of use and availability as per 46 CFR 176.830
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2016
Resolved 7 March 2016
Resolution: Reposition all Sat.
Operations/Management › Drills/Instruction › Fire
Issued 24 February 2016 Resolved
Fire drills have not been performed and/or logged as required. Conduct and log accordingly as per 46 CFR 185.524
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2016
Resolved 7 March 2016
Resolution: Drills and records Sat.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 24 February 2016 Resolved
EPIRB has not been tested and/or logged as required. Test monthly and log as per 46 CFR 185.728
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2016
Resolved 7 March 2016
Resolution: log and test sat.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 24 February 2016 Resolved
Vessel had no radio log. Create and log all radio maintenance and required information, as per 46 CFR 184.502
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2016
Resolved 7 March 2016
Resolution: Radio log created
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 24 February 2016 Resolved
Man overboard drills have not been performed and/or logged as required. Conduct drills and log accordingly, as required by 46 CFR 185.520
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2016
Resolved 7 March 2016
Resolution: Drills and logs all sat.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 24 February 2016 Resolved
The portable fire extinguisher bracket in the accommodation space was wasted and could not hold the fire extinguisher as designed. Replace bracket. IAW 46 CFR 181.30-10 (OLD T)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2016
Resolved 7 March 2016
Resolution: bracket replaced
Lifesaving › Lifejacket/PFD (Type II) › Lights
Issued 24 February 2016 Resolved
Several life jacket lights were non-operational and retroreflective tape damaged. Repair tape and replace light batteries or remove jackets with non-operational lights and damaged tape from vessel IAW 46 CFR 180.75 and 185.604
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2016
Resolved 7 March 2016
Resolution: Life jackets are all sat.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 24 February 2016 Resolved
Vessel had no Employee Assistance Program (EAP) information. Provide required information as per 46 CFR 185.210 and 46 CFR 16.401
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2016
Resolved 7 March 2016
Resolution: EAP info was established
Documentation › Markings/Placards › Oil Discharge Placard
Issued 24 February 2016 Resolved
Oil pollution placard was damaged. Replace with new placard, as per 33 CFR 155.450
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2016
Resolved 7 March 2016
Resolution: placard replaced
Electrical › Electric Generation Source (service) › Generator
Issued 24 February 2016 Resolved
Generator was replaced without notice to OCMI or plan review. Provide details of previous equipment and new installation as per 46 CFR 176.700
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2016
Resolved 22 March 2016
Resolution: Generator installed and working properly. Still needs to be TIER III and am working with owner. Activity 5828198 for more info.
Electrical › Electric Generation Source (service) › Generator
Issued 24 February 2016 Resolved
Generator was rated for 40 degrees Celsius but did not have a de-rated placard. Provide documentation of proof of de-rated to 80% of full load rating, as per 46 CFR 183.10-5 (OLD T)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2016
Resolved 7 March 2016
Resolution: Vessel provided letter from installer of the generator was derated at the electrical breaker to 80%.
Electrical › Electric Generation Source (service) › Grounding Conductor
Issued 24 February 2016 Resolved
Several grounding/bonding wires were not connected as designed. Reattach or replace all grounding wires (engine room, tank room, rudder room), as per 46 CFR 183.01-15 (OLD T)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2016
Resolved 7 March 2016
Resolution: Wires all grounded/bonded
Engineering › Steering Gear System › Piping
Issued 24 February 2016 Resolved
Piping for steering systems was sagging and not properly secured in tank room. Properly secure piping in place with appropriate holders IAW 46 CFR 176.814
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2016
Resolved 7 March 2016
Resolution: piping secured
Deck/Cargo › Mooring/Anchoring › Anchoring Arrangement
Issued 24 February 2016 Resolved
Anchoring/mooring gear was stoward in Forward V compartment under large cooler and not readily accessible. Move gear and replace wasted shackles to make more readily accessible IAW 46 CFR 184.300
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2016
Resolved 7 March 2016
Resolution: all sat
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 24 February 2016 Resolved
The first valve out of the bottom of the starboard fuel tank was seized open and severely wasted. Replace valve IAW 46 CFR 182.20-40 (OLD T)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2016
Resolved 7 March 2016
Resolution: valve replaced
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 24 February 2016 Resolved
Ring buoy lights had expired batteries. Replace with new approved batteries as per 46 CFR 180.70
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2016
Resolved 7 March 2016
Resolution: batteries replaced
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 24 February 2016 Resolved
Life float lights had expired batteries. Replace with new approved batteries as per 46 CFR 180.175(d)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2016
Resolved 7 March 2016
Resolution: batteries replaced
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 24 February 2016 Resolved
Ring buoy on bow was missing name of vessel and the retro-reflective tape was damaged. Ensure name of vessel is on ring buoy and replace retro tape IAW 46 CFR 185.604
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2016
Resolved 7 March 2016
Resolution: ring buoy was properly marked
Lifesaving › Lifefloat › Platform
Issued 24 February 2016 Resolved
Life floats were not seperated by spacers. Place spacers in between life floats when stacked, as per 46 CFR 180.137(f)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2016
Resolved 7 March 2016
Resolution: spacers in place
Engineering › Bilge Water Management System › Strainer
Issued 24 February 2016 Resolved
Bilges in all spaces contained debris and trash. Clean out all bilges to prevent the bilge pumps from being clogged IAW 46 CFR 176.830
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2016
Resolved 7 March 2016
Resolution: bilges cleaned
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 24 February 2016 Resolved
Side lights not installed IAW Nav Rules. Covers must be installed, IAW 46 CFR 183.420.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2016
Resolved 7 March 2016
Resolution: covers installed
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 24 February 2016 Resolved
Generator had no guard over moving parts. Place guard over belt IAW 46 CFR 177.960
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2016
Resolved 7 March 2016
Resolution: guards in place
Engineering › Fuel Oil Service System › Piping
Issued 24 February 2016 Resolved
Fittings on most lines on starboard side of starboard engine were severely wasted. Replace with new fittings. 46 CFR 176.800.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2016
Resolved 7 March 2016
Resolution: fittings replaced
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 24 February 2016 Resolved
Dampers to engine space could not all be closed, particularly starboard foward vent and port forward vent. Replace covers where needed, IAW 46 CFR 181.20-35
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2016
Resolved 7 March 2016
Resolution: covers all sat.
Electrical › Lighting (service) › Lighting Fixture
Issued 24 February 2016 Resolved
Water and mud found in lighting fixture in rudder room. Clean out light, replace if necessary, and seal properly to make watertight, IAW 46 CFR 183.01-15
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2016
Resolved 7 March 2016
Resolution: lighting fixture all sat.
Electrical › Electric Supply System (service) › Battery Installation
Issued 24 February 2016 Resolved
Battery box was missing cover in Forward V room. Replace cover, IAW 46 CFR 183.05-20
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2016
Resolved 7 March 2016
Resolution: cover replaced
Electrical › Lighting (service) › Outlet Box
Issued 24 February 2016 Resolved
Outlet in forward engine room missing cover. Replace cover or renew outlet IAW 46 CFR 183.01-15
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2016
Resolved 7 March 2016
Resolution: outlet all sat.
Engineering › Steering Gear System › Rudder
Issued 24 February 2016 Resolved
Port rudder reference unit not connected to rudder. Reconnect to rudder, IAW 46 CFR 176.814.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2016
Resolved 7 March 2016
Resolution: rudder all sat
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 24 February 2016 Resolved
Vessel had fuel tanks in accommodation spaces (day tanks). Remove tanks from accommodation spaces, IAW 46 CFR 182.20-25(b) (OLD T)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2016
Resolved 7 March 2016
Resolution: tanks removed
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 24 February 2016 Resolved
Throughout vessel, where double hose clamping is required, missing and broken clamps were found. Renew where needed, IAW 46 CFR 176.830
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2016
Resolved 7 March 2016
Resolution: clamps were replaced
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 24 February 2016 Resolved
Access/egress ladder rung to forward V space was damaged. Replace rung to ensure safe access/egress to space, IAW 46 CFR 176.830
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2016
Resolved 7 March 2016
Resolution: ladder all sat
Accommodation/Occupational Safety › Potable Water System › General
Issued 24 February 2016 Resolved
Wash down pump in tank room was new and not completely installed. Finish installation and secure to vessel IAW 46 CFR 176.830
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2016
Resolved 7 March 2016
Resolution: wash down pump was installed
Electrical › Electrical Distribution System (service) › Switch
Issued 24 February 2016 Resolved
Vessel was using vice pliers for switch from shore to generator power behind a seat in accommodation space. Provide proper switch for shore/generator power IAW 46 CFR 176.830
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2016
Resolved 7 March 2016
Resolution: switch installed
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 24 February 2016 Resolved
One of the brackets holding an ice chest in place on deck was missing. Replace bracket to ensure chest is secure IAW 46 CFR 176.830
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2016
Resolved 7 March 2016
Resolution: brackets replaced
Engineering › Fuel Oil Service System › Filter
Issued 24 February 2016 Resolved
Fuel was leaking from fuel filter in engine room and pooling in flame shield. Repair or replace IAW 46 CFR 176.830
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2016
Resolved 7 March 2016
Resolution: fuel filter all sat
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 14 February 2012 Resolved
Renew or service pre-engineered extinguishing system as per 46 CFR 181.420.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2012
Resolved 13 March 2012
Resolution: A new system was purchased, installed and properly tested.
Navigation › Piloting/Steering › Marine Charts
Issued 14 February 2012 Resolved
Provide current and update charts, Coast Pilot [name withheld], Tidal Current Table, and Light List 46 CFR 184.420
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2012
Resolved 13 March 2012
Resolution: All charts and publications were renewed.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (electric)
Issued 14 February 2012 Resolved
Prove proper operation of the port clutch and reduction gear to secure the gear oil leak and broken parts from coming out of the vent as per 46 CFR176.800.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 March 2012
Resolved 13 March 2012
Resolution: The port clutch and reduction gear was rebuilt and the engine was re-align and were satisfactorily tested.
Engineering › Fuel Oil Service System › Discharge Strainer
Issued 14 February 2012 Resolved
Properly install the fuel filter strainer bowl on the stbd fuel filter as per 46 CFR 182.455.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2012
Resolved 13 March 2012
Resolution: The bowl was properly installed.
Electrical › Electric Supply System (service) › Battery Installation
Issued 14 February 2012 Resolved
Provide battery box covers for the batteries in the engine room as per 46 CFR 183.350.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2012
Resolved 13 March 2012
Resolution: The covers were properly installed and secured.
Documentation › Logs/Records › Logbook (official)
Issued 14 February 2012 Resolved
Provide a lifesaving equipment log as per 46 CFR 185.702.
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 March 2012
Resolved 13 March 2012
Resolution: A log was onboard.
Engineering › Bilge Water Management System › Not Operational
Issued 14 February 2012 Resolved
Prove operation of the bilge high level alarm in the rudder room as per 46 CFR 182.530.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2012
Resolved 13 March 2012
Resolution: The alarm was repaired and tested.
Engineering › Steering Gear System › Rudder Bearing
Issued 14 February 2012 Resolved
Properly secure the packing or repack the stbd rudder gudgon packing gland.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2012
Resolved 13 March 2012
Resolution: The packing gland was tighten.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 14 February 2012 Resolved
Provide and install an EPRIB onboard the vessel as per 46 CFR180.64
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 March 2012
Resolved 13 March 2012
Resolution: A new registered EPIRB was onboard, installed and tested.
Communications › Audible Communications › Bell
Issued 1 March 2010 Resolved
Prove operation of the bilge high level alarm in the engine room and lazarette.
Action required: 705 - Other - as specified
Due 1 April 2010
Resolved 8 March 2010
Resolution: The alarms were proven.
Engineering › Fuel Oil Service System › Valve
Issued 1 March 2010 Resolved
Install fuel shut off valves on both main diesel engines at the engines.
Action required: 705 - Other - as specified
Due 1 April 2010
Resolved 8 March 2010
Resolution: Valves were installed at the fuel tanks.
Electrical › Electric Supply System (service) › Battery Installation
Issued 1 March 2010 Resolved
Make repairs to the deteriorated battery box stand on the starboard side in the engine room.
Action required: 705 - Other - as specified
Due 1 April 2010
Resolved 8 March 2010
Resolution: The stand was replaced.
Construction/Loadline › Hull › Stringer
Issued 1 March 2010 Resolved
Make repairs to the sagging structural members in the overhead of the engine room.
Due 1 April 2010
Resolved 8 March 2010
Resolution: The structural member was reattached to the deck beam.
Electrical › Electric Supply System (service) › Cable
Issued 1 March 2010 Resolved
Conduct maintenance on the port side battery bank in the engine room.
Action required: 705 - Other - as specified
Due 1 April 2010
Resolved 8 March 2010
Resolution: Maintenance was conducted.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 1 March 2010 Resolved
Repair the water leak in the port main engine exhaust piping.
Action required: 705 - Other - as specified
Due 1 April 2010
Resolved 8 March 2010
Resolution: New clamps were installed.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 1 March 2010 Resolved
Prove the shut down on the generator shut down for the pre-engineered extinguishing system.
Action required: 705 - Other - as specified
Due 1 April 2010
Resolved 8 March 2010
Resolution: The shutdown was satisfactorily tested.
Engineering › Fuel Oil Service System › Valve, Control
Issued 1 March 2010 Resolved
Prove proper operation of the remote fuel shut off's
Action required: 705 - Other - as specified
Due 1 April 2010
Resolved 8 March 2010
Resolution: The remote fuel shut off were satisfactorily tested.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 15 April 2009 Resolved
Provide Certificate of Documentation
Action required: 705 - Other - as specified
Due 15 May 2009
Resolved 15 April 2009
Resolution: COD was not onboard during inspection, owner provided it after inspection.
Navigation › Piloting/Steering › US Coast Pilot
Issued 15 April 2009 Resolved
Provide a current US Coast Pilot
Action required: 705 - Other - as specified
Due 15 May 2009
Resolved 12 May 2009
Resolution: New Coast Pilot purchased
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 15 April 2009 Resolved
Provide current tidal current tables.
Action required: 705 - Other - as specified
Due 15 May 2009
Resolved 12 May 2009
Resolution: Provided Tidal Current tables
Electrical › Electric Generation Source (service) › Generator
Issued 15 April 2009 Resolved
Remove paint from data plate on generator as per 46 CFR 183.320 (e)
Action required: 705 - Other - as specified
Due 15 May 2009
Resolved 12 May 2009
Resolution: New plate installed
Engineering › Diesel Engine (propulsion-reduction gear) › Crankcase
Issued 15 April 2009 Resolved
Make repairs to secure leak from the cooler to the injection port on port main engine.
Action required: 705 - Other - as specified
Due 15 May 2009
Resolved 12 May 2009
Resolution: Leaking secured
Engineering › Diesel Engine (propulsion-reduction gear) › Valve
Issued 15 April 2009 Resolved
Make repairs to secure lube oil leak on port main engine.
Action required: 705 - Other - as specified
Due 15 May 2009
Resolved 12 May 2009
Resolution: Oil leak secured
Engineering › Diesel Engine (propulsion-reduction gear) › Silencer (exhaust)
Issued 15 April 2009 Resolved
Make repairs to secure exhaust leak on starboard main engine.
Action required: 705 - Other - as specified
Due 15 May 2009
Resolved 12 May 2009
Resolution: New exhaust piping installed
Engineering › Steering Gear System › Interlock
Issued 15 April 2009 Resolved
Make repairs to tiller arm connection on port rudder.
Action required: 705 - Other - as specified
Due 15 May 2009
Resolved 12 May 2009
Resolution: Tiller arm adjusted and operating properly.
Fire Fighting › Remote Fuel Shutoff › General
Issued 15 April 2009 Resolved
Prove proper operation of fuel shutdowns.
Action required: 705 - Other - as specified
Due 15 May 2009
Resolved 12 May 2009
Resolution: Fuel shutoffs operation satisfactory.
Electrical › Electrical Distribution System (service) › Cable
Issued 15 April 2009 Resolved
Remove wire nuts or install junction box for wiring on macerator pump.
Action required: 705 - Other - as specified
Due 15 May 2009
Resolved 12 May 2009
Resolution: Junction box installed
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 15 April 2009 Resolved
Provide waterlight for one (1) lifefloat.
Action required: 705 - Other - as specified
Due 15 May 2009
Resolved 12 May 2009
Resolution: New waterlight provided.
Construction/Loadline › Penetrations › Valve Flange
Issued 26 February 2009 Resolved
Replace seawater intake valve handle on port engine.
Action required: 705 - Other - as specified
Resolved 2 March 2009
Resolution: Entire valve for seawater intake on port engine was replaced.
Construction/Loadline › Penetrations › Valve Flange
Issued 26 February 2009 Resolved
Provide nut to secure washwater valve handle on port side.
Action required: 705 - Other - as specified
Resolved 2 March 2009
Resolution: Entire port side washwater valve was replaced.
Construction/Loadline › Hull › Side Shell
Issued 26 February 2009 Resolved
Grind out areas on hull as marked and repair as original with polyester resin and cloth fiberglass.
Action required: 705 - Other - as specified
Resolved 2 March 2009
Resolution: All areas of the hull that showed delaminating were properly ground out and repaired as original.
Construction/Loadline › Hull › Bottom Plating
Issued 26 February 2009 Resolved
Remove and renew both propellers.
Action required: 705 - Other - as specified
Resolved 2 March 2009
Resolution: Both propellers were serviced, and areas that showed pitting were renewed.
Lifesaving › Lifefloat › Serviceable
Issued 26 February 2008 Resolved
Replace grabline on bottom lifefloat as per 46 CFR 180.150.
Due 26 March 2008
Resolved 13 March 2008
Resolution: Grabline was replaced on lifefloat.
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 26 February 2008 Resolved
Replace the safety glass in the starboard side main deck door as per 46 CFR 177.1010.
Due 26 March 2008
Resolved 13 March 2008
Resolution: Safety glass was replaced.
Engineering › Generator (propulsion/auxiliary-electric) › Junction Box
Issued 26 February 2008 Resolved
Replace the plastic control box for the generator as per 46 CFR 176.800.
Due 26 March 2008
Resolved 13 March 2008
Resolution: Plastic box was replaced.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 26 February 2008 Resolved
Replace the rubber hose for the exhaust cooling on the generator as per 46 CFR 182.430.
Due 26 March 2008
Resolved 13 March 2008
Resolution: Rubber hose was replaced.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 26 February 2008 Resolved
Replace 2 rubber hoses on the outboard side of the port engine for the fuel return and drain for crank case pressure as per 46 CFR 182.430.
Due 26 March 2008
Resolved 13 March 2008
Resolution: Two rubber hoses were replaced.
Stability › Unintentional Flooding › General
Issued 26 February 2008 Resolved
Plug the through hull penetration in the side shell of the aft, starboard side of the engine room as per 46 CFR 176.800.
Due 26 March 2008
Resolved 13 March 2008
Resolution: Through hull penetration was plugged.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 16 April 2007 Resolved
Provide and install a fire extinguisher mounting bracket to replace the deteriorated mounting bracket for the extinguishers in the wheel house and the forward salon in accordance with 46 CFR 181.520.
Action required: 705 - Other - as specified
Due 16 May 2007
Resolved 19 April 2007
Resolution: New mounting brackets were purchased and installed.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 16 April 2007 Resolved
Prove proper operation of the navigation lights (running lights) on the port and starboard sides in accordance with 46 CFR 183.420.
Due 16 May 2007
Resolved 19 April 2007
Resolution: New light were purchased and installed and properly tested with satisfactory results.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 16 April 2007 Resolved
Prove proper operation of the anchor light in accordance with 46 CFR 183.420.
Action required: 705 - Other - as specified
Due 16 May 2007
Resolved 19 April 2007
Resolution: The anchor light was tested with satisfactory results.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 16 April 2007 Resolved
Illuminate the magnetic compass in accordance with 46 CFR 184.402.
Action required: 705 - Other - as specified
Due 16 May 2007
Resolved 19 April 2007
Resolution: The compass was properly illuminated.
Stability › Weathertight Integrity › General
Issued 16 April 2007 Resolved
Replace the deteriorated combing at the wheel house weather tight door in accordance with NVIC 8-87.
Action required: 705 - Other - as specified
Due 16 May 2007
Resolved 19 April 2007
Resolution: The combing was replaced.
Construction/Loadline › Penetrations › Pipe Flange
Issued 16 April 2007 Resolved
Make repairs to the deck drain in the wheel house by replacing the missing piping to fill the hole in the deck in accordance with 46 CFR 176.800.
Due 16 May 2007
Resolved 20 April 2007
Resolution: The drain was repaired.
Communications › Radio Communications › EPIRB
Issued 16 April 2007 Resolved
Register the EPIRB and prove it has been registered in accordance with 46 CFR 180.64.
Action required: 705 - Other - as specified
Due 16 May 2007
Resolved 19 April 2007
Resolution: The EPIRB is now registered.
Electrical › Lighting (service) › Lighting Fixture
Issued 16 April 2007 Resolved
Provide a lens cover for the lights in the wheel house and the forward salon in accordance with 46 CFR 183.410.
Action required: 705 - Other - as specified
Due 16 May 2007
Resolved 19 April 2007
Resolution: The entire light fixture in the wheel house was replaced and a lens cover was place of the over the tubes in the salon.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 16 April 2007 Resolved
Replace the deteriorated boards on the fixed seating on the 01 deck in accordance with 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 16 May 2007
Resolved 20 April 2007
Resolution: All of the boards were replaced on the fixed seating on the 01 deck.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 16 April 2007 Resolved
Properly attach the water lights to the life floats in accordance with 46 CFR 180.175.
Action required: 705 - Other - as specified
Due 16 May 2007
Resolved 19 April 2007
Resolution: The water lights were properly attached to the life floats by splicing the line/lanyards back into itself which alleviated the knots.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 16 April 2007 Resolved
Provide and install the proper batteries in the water lights for the life floats and the ring buoy in accordance with 46 CFR 108.70 and 46 CFR 180.175.
Action required: 705 - Other - as specified
Due 16 May 2007
Resolved 19 April 2007
Resolution: The spring type 6 volt batteries were replace with the screw down type batteries called for on the light itself.
Lifesaving › Lifefloat › Netting
Issued 16 April 2007 Resolved
Replace the deteriorated 22 persons life float with the broken/deteriorated metal retainer for the basket in accordance with 46 CFR 180.200.
Action required: 705 - Other - as specified
Due 16 May 2007
Resolved 19 April 2007
Resolution: A new 22 person life float was purchased and placed onboard properly stowed.
Lifesaving › Lifefloat › Painter
Issued 16 April 2007 Resolved
Properly attach the painter line around the body of the life float. in accordance with 46 CFR 180.175
Action required: 705 - Other - as specified
Due 16 May 2007
Resolved 19 April 2007
Resolution: The painter lines were properly attached to the life float.
Lifesaving › Lifebuoys › Serviceable
Issued 16 April 2007 Resolved
Replace the grab lines on the two life rings or replace both life rings in accordance with 46 CFR 180.70.
Action required: 705 - Other - as specified
Due 16 May 2007
Resolved 19 April 2007
Resolution: The two deteriorated life rings were replaced.
Stability › Watertight Integrity › General
Issued 16 April 2007 Resolved
Prove proper operation of the watertight hatch in the deck of the forepeak in accordance with 46 CFR 179.360.
Action required: 705 - Other - as specified
Due 16 May 2007
Resolved 20 April 2007
Resolution: The watertight hatch was serviced by disassembling and performing proper maintenance. The gasket was also replaced.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 16 April 2007 Resolved
Provide life jackets for 66 adults and 7 child and properly clean, stencil, retape and replace the life jackets as needed in accordance with 46 CFR 180.71.
Action required: 705 - Other - as specified
Due 16 May 2007
Resolved 19 April 2007
Resolution: The lifejackets were cleaned, properly stenciled and retaped. Also all of the child life were discarded and replaced along with several adult lifejackets. The total number of adult/child lifejackets on board were 66/10 respectively.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 16 April 2007 Resolved
Replace the water light on the life ring on the bow or prove proper operation of the existing lights in accordance with 46 CFR 180.70.
Action required: 705 - Other - as specified
Due 16 May 2007
Resolved 19 April 2007
Resolution: The water light was replaced on the life ring.
Electrical › Electric Generation Source (service) › Generator
Issued 16 April 2007 Resolved
Prove the ships service generator has been derated in accordance with 46 CFR 183.320
Action required: 705 - Other - as specified
Due 16 May 2007
Resolved 19 April 2007
Resolution: The Main breaker was replaced to meet the requirement of using only 80 % of the maximum output.
Engineering › Fuel Oil Service System › Filter
Issued 16 April 2007 Resolved
Remove the plastic drain plug from the generator fuel oil filter and install a metal plug in accordance with 46 CFR 182.455.
Action required: 705 - Other - as specified
Due 16 May 2007
Resolved 19 April 2007
Resolution: A metal plug was installed in the generator fuel oil filter drain.
Electrical › Lighting (service) › Lighting Fixture
Issued 16 April 2007 Resolved
Prove proper operation of the engine room lights, several of the lights were not working in accordance with 46 CFR 183.410.
Action required: 705 - Other - as specified
Due 16 May 2007
Resolved 19 April 2007
Resolution: All lights in the engine room were working.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 16 April 2007 Resolved
Clean the vessel by properly stowing loose gear and cleaning in accordance with 46 CFR 176.800.
Due 16 May 2007
Resolved 20 April 2007
Resolution: All loose gear was properly stowed or removed and the vessel was cleaned.
Personnel › Training › Familiarization Training
Issued 16 April 2007 Resolved
Make the crew and vessel ready for all drills prior to receiving the COI in accordance with 46 CFR 185.520 and 46 CFR 185.524.
Action required: 705 - Other - as specified
Due 16 May 2007
Resolved 19 April 2007
Resolution: A drills were conducted with satisfactory results.
Stability › Weathertight Integrity › General
Issued 5 April 2007 Resolved
Replace the two plexi glass windows in the wheel house and replace with safety glass in accordance with 46 CFR 177.1010.
Action required: 705 - Other - as specified
Due 16 May 2007
Resolved 20 April 2007
Resolution: The windows were replaced with safety glass.
Engineering › Bilge Water Management System › Valve
Issued 26 February 2007 Resolved
Replace the valve at the hull for the bilge overboard discharge in the lazarette in accordance with 46 CFR 182.520.
Action required: 705 - Other - as specified
Due 26 March 2007
Resolved 1 March 2007
Resolution: Replaced the valve at the hull for the bilge overboard discharge in the lazarette.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 26 February 2007 Resolved
Repair the sewage line in the lazarette in accordance with 46 CFR 182.720.
Action required: 705 - Other - as specified
Due 26 March 2007
Resolved 1 March 2007
Resolution: Properly repaired the sewage line in the lazarette.
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 26 February 2007 Resolved
Properly cap the old sewage line in the lazarette in accordance with 46 CFR 182.720.
Action required: 705 - Other - as specified
Due 26 March 2007
Resolved 1 March 2007
Resolution: Properly capped the old sewage line in the lazarette.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 26 February 2007 Resolved
Provide and install hose clamps on starboard exhaust fitting in the lazarette in accordance with 46 CFR 182.430.
Action required: 705 - Other - as specified
Due 26 March 2007
Resolved 1 March 2007
Resolution: Provided and installed hose clamps on the starboard exhaust fitting in the lazarette.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 26 February 2007 Resolved
Replace all marked stanchions for the deck rail in accordance with 46 CFR 177.900.
Action required: 705 - Other - as specified
Due 26 March 2007
Resolved 1 March 2007
Resolution: Replaced all marked stanchions for the deck rail.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 26 February 2007 Resolved
Properly mount the stanchion for the deck rail on the upper deck near the lifefloats in accrodance with 46 CFR 177.900.
Action required: 705 - Other - as specified
Due 26 March 2007
Resolved 1 March 2007
Resolution: Properly mounted the stanchion for the deck rail on the upper deck near the lifefloats.
Stability › Watertight Integrity › General
Issued 26 February 2007 Resolved
Replace the gasket on the hatch leading into the collision bulkhead space in accordance with 46 CFR 179.310.
Action required: 705 - Other - as specified
Due 26 March 2007
Resolved 1 March 2007
Resolution: Replaced the gasket on the hatch leading inot the collision bulkhead space.
Construction/Loadline › Hull › Hull Plating
Issued 26 February 2007 Resolved
Grind out and repair the patch on the hull inside the forward peak in accordance with NVIC 8-87.
Action required: 705 - Other - as specified
Due 26 March 2007
Resolved 1 March 2007
Resolution: Properly repaired the patch on the hull inside the forward peak.
Engineering › Bilge Water Management System › Valve
Issued 26 February 2007 Resolved
Make all sea-valves ready for inspection in accordance with 46 CFR 176.802.
Action required: 705 - Other - as specified
Due 26 March 2007
Resolved 1 March 2007
Resolution: All sea valves were made ready for inspection and satisfactorily inspected.
Construction/Loadline › Hull › Hull Plating
Issued 26 February 2007 Resolved
Grind out all marked areas on the hull and make ready for inspeciton prior to making repairs in accordance with NVIC 8-87.
Action required: 705 - Other - as specified
Due 26 March 2007
Resolved 1 March 2007
Resolution: All marked areas were ground out and properly inspected.
Engineering › Fuel Oil Service System › Piping
Issued 22 May 2006 Resolved
Replace all fuel ooil tubing in tank space in accordance with 46CFR182.455
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2006
Resolved 18 July 2006
Resolution: Replaced all fuel oil tubing in tank space in accordance with 46 CFR 182.455.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 22 May 2006 Resolved
Repair leaking weld on starboard engine cooling piping outboard side in accordance with 46CFR182.720
Action required: 705 - Other - as specified
Due 22 June 2006
Resolved 18 July 2006
Resolution: Repaired leaking weld on starboard engine cooling piping outboard side in accordance with 46 CFR 182.720.
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 May 2006 Resolved
Remove wire nuts from live well pump and connect using proper connecting methods in accordance with 46CFR183.340
Action required: 705 - Other - as specified
Due 22 June 2006
Resolved 18 July 2006
Resolution: Removed wire nuts from live well pump and connected using proper methods in accordance with 46 CFR 183.340.
Electrical › Lighting (service) › Lighting Fixture
Issued 22 May 2006 Resolved
Provide cover for flourescent light in engine room in accordance with 46CFR183.410
Action required: 705 - Other - as specified
Due 22 June 2006
Resolved 18 July 2006
Resolution: Provided cover for fluorescent light in engine room in accordance with 46 CFR 183.410.
Electrical › Lighting (service) › Lighting Fixture
Issued 22 May 2006 Resolved
Remove unused lighting fixtures in the engine room in accordance with 46CFR183.200
Action required: 705 - Other - as specified
Due 22 June 2006
Resolved 18 July 2006
Resolution: Removed unused lighting fixtures in the engine room in accordance with 46 CFR 183.200.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 22 May 2006 Resolved
Provide a bank for generator breaker panel in accordance with 46CFR183.200
Action required: 705 - Other - as specified
Due 22 June 2006
Resolved 18 July 2006
Resolution: Provided a bank for generator breaker panel in accordance with 46 CFR 183.200.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 22 May 2006 Resolved
Provide covers for plugs in the engine room spaces 46 CFR 183.200
Action required: 705 - Other - as specified
Due 22 June 2006
Resolved 18 July 2006
Resolution: Provided covers for plugs in the engine room spaces 46 CFR 183.200.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 22 May 2006 Resolved
Tighten clamp on port main exhaust in the engine room. 46CFR182.720
Action required: 705 - Other - as specified
Due 22 June 2006
Resolved 18 July 2006
Resolution: Tightened clamp on port main exhaust in the engine room. 46 CFR 182.720.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 22 May 2006 Resolved
Remove oil and trash from engine room and tank space bilges 46CFR176.830
Action required: 705 - Other - as specified
Due 22 June 2006
Resolved 18 July 2006
Resolution: Removed oil and trash from engine room and tank space bilges. 46 CFR 176.830
Engineering › Bilge Water Management System › Piping
Issued 22 May 2006 Resolved
Replace melted hose in lazarette 46CFR182.720
Action required: 705 - Other - as specified
Due 22 June 2006
Resolved 18 July 2006
Resolution: Replaced melted hose in lazarette. 46 CFR 182.720
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 22 May 2006 Resolved
Provide 5 adult life jackets and provide retro on all jackets where needed in accordance with 46CFR180.71
Action required: 705 - Other - as specified
Due 22 June 2006
Resolved 18 July 2006
Resolution: Provided 5 adult life jackets and provide on all jackets where needed in accordance with 46 CFR 180.71
Communications › Radio Communications › VHF Radiotelephone
Issued 22 May 2006 Resolved
Provide FCC marine radio operator permit in accordance with 47CFR
Action required: 705 - Other - as specified
Due 22 June 2006
Resolved 18 July 2006
Resolution: Provided FCC marine radio operator permit in accordance with 47 CFR.
Documentation › Markings/Placards › Capacity Marking
Issued 22 May 2006 Resolved
Properly mark upper deck for amount of passengers allowed topside in accordance with 46CFR185.602
Action required: 705 - Other - as specified
Due 22 June 2006
Resolved 18 July 2006
Resolution: Properly marked upper deck for amount of passengers allowed topside in accordance with 46 CFR 185.602.
Lifesaving › Lifefloat › Float-free Link
Issued 22 May 2006 Resolved
Prove installed weak link for the lifefloats is the appropriate size for the number of persons in accordance with 46CFR180.130
Action required: 705 - Other - as specified
Due 22 June 2006
Resolved 18 July 2006
Resolution: Proved the installed weak link for the lifefloats is the appropriate size for the number of persons in accordance with 46 CFR 180.130.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 5 April 2005 Resolved
Provide valid certificate of documentation IAW 46 CFR 67.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 April 2005
Resolution: Certificate was provided.
Documentation › Certificates/Documents › FCC SSL
Issued 5 April 2005 Resolved
Provide FCC Safety Certificate IAW 47 CFR 80.
Action required: 705 - Other - as specified
Due 5 May 2005
Resolved 7 April 2005
Resolution: FCC Safety Certificate was provided.
Personnel › Certificates/Documents/Licenses › Certificate, CPR Course Completion
Issued 5 April 2005 Resolved
Provide valid CPR/First Aid cards for 50% of the crew IAW NVIC 1-91
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 April 2005
Resolution: CPR/ First aid cards were provided.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 5 April 2005 Resolved
Provide proof of enrollment in a drug and alcohol program IAW 46 CFR 16
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 April 2005
Resolution: Proof of enrollment was provided.
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 5 April 2005 Resolved
Provide marine radio operator's permit IAW 47 CFR 80
Action required: 705 - Other - as specified
Due 5 May 2005
Resolved 7 April 2005
Resolution: Marine radio operator''s permit was provided.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 5 April 2005 Resolved
Provide Coast Guard Light List IAW 46 CFR 184-420
Action required: 705 - Other - as specified
Due 5 May 2005
Resolved 7 April 2005
Resolution: Light list was provided.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 5 April 2005 Resolved
Provide current tables IAW 46 CFR 184.420
Action required: 705 - Other - as specified
Due 5 May 2005
Resolved 7 April 2005
Resolution: Current tables were provided.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 5 April 2005 Resolved
Provide tide tables IAW 46 CFR 184.420
Action required: 705 - Other - as specified
Due 5 May 2005
Resolved 7 April 2005
Resolution: Tide tables were provided.
Navigation › Piloting/Steering › US Coast Pilot
Issued 5 April 2005 Resolved
Provide US Coast Pilot. IAW 46 CFR 184.420
Action required: 705 - Other - as specified
Due 5 May 2005
Resolved 7 April 2005
Resolution: Coast Pilot was provided.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 5 April 2005 Resolved
Provide rules of the road IAW 46 CFR 184.420
Action required: 705 - Other - as specified
Due 5 May 2005
Resolved 7 April 2005
Resolution: Rules of the Road was provided.
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 5 April 2005 Resolved
Repair SSB as required IAW 46 CFR 184.502
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2005
Resolved 7 April 2005
Resolution: SSB was repaired and operable.
Communications › Radio Communications › EPIRB
Issued 5 April 2005 Resolved
Provide proof that EPIRB is registered w/ NOAA IAW 46 CFR 184.502
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 April 2005
Resolution: EPIRB was registered w/ NOAA
Lifesaving › Lifefloat › Retroreflective Material
Issued 5 April 2005 Resolved
Renew retroreflective material on lifefloat IAW NVIC 2-63
Action required: 705 - Other - as specified
Due 5 May 2005
Resolved 7 April 2005
Resolution: Retroreflective material was renewed.
Lifesaving › Lifefloat › Painter
Issued 5 April 2005 Resolved
Connect painter to lifefloat IAW 46 CFR 180.137
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 April 2005
Resolution: Painter was connected IAW 46 CFR 180.137
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 5 April 2005 Resolved
Repair leak in cooling water system IAW 46 CFR 182.420
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 April 2005
Resolution: Leak was repaired by tightening the hose clamps on non metallic piping connection.
Communications › Alarms/Indicators › Bilge Alarm
Issued 5 April 2005 Resolved
Provide visual indicator for engine room bilge pump IAW 46 CFR 182.530
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2005
Resolved 7 April 2005
Resolution: Visual indicator was provided and operationally.
Engineering › Bilge Water Management System › Pump
Issued 5 April 2005 Resolved
Repair bilge pump in aft compartment IAW 46 CFR 182.520
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 April 2005
Resolution: Bilge pump in aft compartment was repaired and operational.
Engineering › Steering Gear System › Ram
Issued 5 April 2005 Resolved
Repair rudder arm by way of ram on bulkhead IAW 46 CFR 176.800
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 April 2005
Resolution: Ram was secured against bulkhead reducing friction in steering system.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 5 April 2005 Resolved
Provide one B-I fire extinguisher IAW 46 CFR 181.500
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 April 2005
Resolution: One B-I extinguisher was provided.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 28 March 2005 Resolved
Renew retro on 10 PFDs IAW 46 CFR 185.604
Action required: 705 - Other - as specified
Due 5 May 2005
Resolved 7 April 2005
Resolution: Retro was renewed
Engineering › Sea-water System (primary cooling) › Valve
Issued 16 February 2005 Resolved
Renew or repair starboard main engine raw water intake valve handle and prove operation of valve as per 46 CFR 179.350(c).
Action required: 705 - Other - as specified
Due 16 March 2005
Resolved 5 April 2005
Resolution: Valve handle replaced and proven operational..
Engineering › Bilge Water Management System › Valve
Issued 16 February 2005 Resolved
Renew or repair bilge pump through hull valve handle in stern compartment and prove operation as per 46 CFR 179.350(c).
Action required: 705 - Other - as specified
Due 16 March 2005
Resolved 5 April 2005
Resolution: Valve handle was replaced.
Construction/Loadline › Hull › Hull Plating
Issued 16 February 2005 Resolved
Repair two blisters and one delaminated area on stbd. side IAW NVIC 8-87.
Action required: 705 - Other - as specified
Due 16 March 2005
Resolved 17 February 2005
Resolution: The blisters were ground out, faired and painted IAW 8-87. The delaminated portion was ground out and refiberglassed IAW the guidlines given in NVIC 8-87.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 11 February 2004 Resolved
Secure ladder to engine room per 46 CFR 177.500(k). LEGACY COMPONENT DESC: Ladder
Due 11 March 2004
Resolved 5 April 2005
Resolution: Ladder was secured.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 11 February 2004 Resolved
Replace bonding/grounding straps in forward compartment. 46 CFR 183.340(b) LEGACY COMPONENT DESC: Grounding Conductor
Due 11 March 2004
Resolved 5 April 2005
Resolution: Bonding straps were replaced
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 11 February 2004 Resolved
Replace the bottom cover plate on the battery charger in the forward compartment. 46 CFR 183.200 LEGACY COMPONENT DESC: Battery Charger
Due 11 March 2004
Resolved 5 April 2005
Resolution: Cover plate was replaced
Electrical › Electrical Distribution System (emergency) › Ground Detection
Issued 11 February 2004 Resolved
Provide battery covers for all three battery boxes. 46 CFR 183.354(b) LEGACY COMPONENT DESC: battery boxes
Due 11 March 2004
Resolved 5 April 2005
Resolution: Battery covers were provided.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 11 February 2004 Resolved
Provide electrical face plate cover for electrical outlet in the engine room. 46 CFR 183.200 LEGACY COMPONENT DESC: cover plates
Due 11 March 2004
Resolved 5 April 2005
Resolution: Face covers were provided.
Engineering › Fuel Oil Service System › Valve
Issued 11 February 2004 Resolved
Secure wood supports for the fuel shutoff valves. 46 CFR 182.455(b)(4).
Due 11 March 2004
Resolved 5 April 2005
Resolution: Wood supports were secured.
Fire Fighting › Fire Hoses › Condition
Issued 11 February 2004 Resolved
Provide commercial grade hose nozzle made of brass or equivalent material. 46 CFR 181.320(d) LEGACY COMPONENT DESC: Nozzle
Due 11 March 2004
Resolved 5 April 2005
Resolution: Commercial grade hose was provided.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 11 February 2004 Resolved
Provide 2 adult lifejackets with lifejacket light, including markings. Vessel is limited to carrying 60 passengers. 46 CFR 180.71
Action required: 705 - Other - as specified
Due 11 March 2004
Resolved 5 April 2005
Resolution: Two pfd w/ required equipment was provided.
Electrical › Electrical Distribution System (service) › Overcurrent Device
Issued 11 February 2004 Resolved
Provide amp meter and frequency meter to monitor electrical power from the generator. 46 CFR 183.320(c). LEGACY COMPONENT DESC: amp meter/frequency meter
Due 11 March 2004
Resolved 5 April 2005
Resolution: Ammeter and frequency meter was provided.
Operations/Management › Drug and Alcohol Testing
Issued 1 May 2003 Resolved
Provide drug testing enrollment card for crewmember as per 46 CFR part 16. LEGACY COMPONENT DESC: Proof of Enrollment
Due 22 May 2003
Resolved 14 July 2003
Resolution: Master provided proof that all crewmembers are enrolled in drug testing program.
Personnel › Certificates/Documents/Licenses
Issued 1 May 2003 Resolved
Provide FCC Radio Operators Permit as per 47 CFR part 80. LEGACY COMPONENT DESC: FCC Operators Permit
Due 22 May 2003
Resolved 14 July 2003
Resolution: Master provided re-issued FCC Radio Operator''s Permit. Original was lost.
Engineering › Steering Gear System
Issued 1 May 2003 Resolved
Make permanent repairs to starboard rudder tube packing gland as per 46 CFR 176.802. LEGACY COMPONENT DESC: Rudder
Due 22 May 2003
Resolved 6 May 2003
Resolution: Permanent repairs made to rudder.
Pollution Prevention/Response › Prevention Equipment
Issued 1 May 2003 Resolved
Provide locking mechanism for MSD overboard discharge valve as per 46 CFR 159.95 LEGACY COMPONENT DESC: Sewage System Valve
Due 22 May 2003
Resolved 6 May 2003
Resolution: Lock provided.
Lifesaving › Lifebuoys
Issued 1 May 2003 Resolved
Renew retro-reflective material on ring life buoy as per 46 CFR 180.72. LEGACY COMPONENT DESC: Retro Tape
Due 22 May 2003
Resolved 6 May 2003
Resolution: New retro placed on ring buoy.
Electrical › Electric Generation Source (service)
Issued 1 May 2003 Resolved
Install directory of circuits for each electrical distribution panel. LEGACY COMPONENT DESC: Panelboard
Due 22 May 2003
Resolved 6 May 2003
Resolution: Panel labeled
Engineering › Bilge Water Management System
Issued 31 March 2003 Resolved
Remove oily waste from forward void as required 46 CFR 176.610. LEGACY COMPONENT DESC: OIl in Bilges
Due 31 March 2003
Resolved 31 March 2003
Resolution: oil removed.
Electrical › Electric Generation Source (service)
Issued 31 March 2003 Resolved
Removed temporary battery installation in forward void as required by 46 CFR 183.340. LEGACY COMPONENT DESC: Temp battery installation
Due 31 March 2003
Resolved 31 March 2003
Resolution: Battery removed.
Engineering › Diesel Engine (auxiliary)
Issued 31 March 2003 Resolved
Provide permanant mount for generator exhaust as required by 46 CFR 182.430. LEGACY COMPONENT DESC: Exhuast
Due 22 April 2003
Resolved 22 April 2003
Resolution: repairs made
Construction/Loadline › Hull
Issued 31 March 2003 Resolved
Provide bolt for engine room main deck stringer mounting bracket (forward bulkhead) as required by 46 CFR 176.610. LEGACY COMPONENT DESC: Longitudinal Frame
Due 31 March 2003
Resolved 31 March 2003
Resolution: bolt provided.
Engineering › Bilge Water Management System
Issued 31 March 2003 Resolved
Remove filter from engine room submersible pump hose as required by 46 CFR 182.510. LEGACY COMPONENT DESC: Filter
Due 31 March 2003
Resolved 31 March 2003
Resolution: filter removed.
Construction/Loadline › Structures
Issued 31 March 2003 Resolved
Provide flange on both fiberglass exhaust bulkhead penetrations for plans for new installation as required by 46 CFR 182.430. LEGACY COMPONENT DESC: Transverse Bulkhead
Due 22 April 2003
Resolved 22 April 2003
Resolution: repairs made to bulkhead.
Engineering › Bilge Water Management System
Issued 31 March 2003 Resolved
Remove oily water from lazerette and make ready for inspection as required by 46 CFR 176.610. LEGACY COMPONENT DESC: Oily waste
Due 31 March 2003
Resolved 31 March 2003
Resolution: oily water removed.
Stability › Watertight Integrity
Issued 17 May 2002 Resolved
All penetrations in the vessel's required watertight bulkheads must be as high and as far inboard as practicable , and made watertight to the satisfaction of the attending marine inspector as required by 46 CFR 179.320. Vessel is restricted to the carriage of not more than forty-nine passengers. LEGACY COMPONENT DESC: Pipe Penetrations
Condition: Improper Installation
Due 17 August 2002
Resolved 17 September 2002
Resolution: Amended COI, max 49 passengers at time of Inspection for Certification. Vessel passenger capacity will remain 49 untill subdivision requirments are met.
Documentation
Issued 14 May 2001 Resolved
PROVIDE VALID FCC OPERATORS PERMIT AS REQUIRED BY 47 CFR 80.155
Condition: Unknown
Due 25 May 2001
Resolved 25 May 2001
Lifesaving
Issued 14 May 2001 Resolved
PROVIDE PROPER WATERTIGHT CONTAINER FOR DISTRESS FLARES AS REQUIRED BY 46 CFR 180.68(E)(I)
Condition: Unknown
Due 25 May 2001
Resolved 25 May 2001
Fire Fighting
Issued 14 May 2001 Resolved
PROVIDE B-1 FIRE EXTINGUISHER AS REQUIRED BY 46 CFR 176.810
Condition: Unknown
Due 25 May 2001
Resolved 25 May 2001
Fire Fighting
Issued 14 May 2001 Resolved
PROVE PROPER OPERATION OF PORT ENGINE SHUTDOWN FOR FIXED FIRE EXTINGUISHINGSYSTEM AS REQUIRED BY 46 CFR 181.410_x001C_ CORRECT PRIOR TO CARRYING PASSENGERS FOR HIRE
Condition: Unknown
Due 25 May 2001
Resolved 25 May 2001
Accommodation/Occupational Safety
Issued 14 May 2001 Resolved
PROVIDE DERATING PLACARD FOR GENERATOR AS REQUIRED BY 46 CFR 183.320(E)
Condition: Unknown
Due 14 May 2001
Resolved 14 May 2001
Navigation
Issued 14 May 2001 Resolved
PROVIDE LIGHT FOR MAGNITIC COMPASS AS REQUIRED BY 46 CFR 184.402
Condition: Unknown
Due 14 May 2001
Resolved 14 May 2001
Navigation
Issued 14 May 2001 Resolved
PROVE PROPER OPERATION OF SINGLE SIDE BAND RADIO AS REQUIRED BY 46 CFR 184.502._x001C_ CORRECT PRIOR TO OPERATING GREATER THAN -20- NAUTICAL MILES FROM A HARBOR OF SAFE REFUGE
Condition: Unknown
Due 14 May 2001
Resolved 14 May 2001
Construction/Loadline
Issued 14 May 2001 Resolved
MAKE E/R AND LAZARETTE BULKHEADS WATERTIGHT AS REQUIRED BY 46 CFR 176.802._x001C_CORRECT PRIOR TO CARRYING PASSENGERS FOR HIRE
Condition: Unknown
Due 25 May 2001
Resolved 25 May 2001
Engineering
Issued 14 May 2001 Resolved
PROVIDE DOUBLE HOSE CLAMPS FOR STBD EXHAUST PIPING IN FUEL TANK SPACE AS REQUIRED BY 46 CFR 182.430
Condition: Unknown
Due 25 May 2001
Resolved 25 May 2001
Engineering
Issued 14 May 2001 Resolved
PROPERLY REPAIR LEAKS IN PORT MAIN ENGINE EXHAUST PIPING AS REQUIRED BY 46_x001C_CFR 182.430._x001C_ CORRECT PRIOR TO CARRYING PASSENGERS FOR HIRE
Condition: Unknown
Due 25 May 2001
Resolved 25 May 2001
Electrical
Issued 14 May 2001 Resolved
PROVIDE PROPER SUPPORTS FOR BATTERY CABLES AS REQUIRED BY 46 CFR 183.340
Condition: Unknown
Due 14 May 2001
Resolved 14 May 2001
Electrical
Issued 20 July 2000 Resolved
PROVIDE AND INSTALL BATTERY SWITCHES ON BOTH MDE'S BATTERY SUPPLY CABLES AND THE S/S GEN BATTERY CABLE AS REQUIRED BY 46 CFR 183.05-20
Condition: Unknown
Due 20 July 2000
Resolved 20 July 2000
Electrical
Issued 20 July 2000 Resolved
REPLACE EXISTING WELDING CABLE FOUND ON S/S GEN STARTING CIRCUT WITH PROPERWIRE AS REQUIRED BY 46 CFR 183.340.
Condition: Unknown
Due 20 July 2000
Resolved 20 July 2000
Navigation
Issued 3 May 2000 Resolved
PROVIDE FCC SAFETY RADIO CERTIFICATE AS REQUIRED BY 47 CFR 80.903.
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Lifesaving
Issued 3 May 2000 Resolved
PROVIDE EPIRB TEST LOG AS REQUIRED BY 46 CFR 185.604(c).
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Engineering
Issued 3 May 2000 Resolved
PROVIDE SUPPORT BRACKETS FOR THE EXHAUST MUFFLERS AS REQUIRED BY 46 CFR 182.425.
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Engineering
Issued 3 May 2000 Resolved
PROVIDE AND INSTALL FUEL OIL STRAINER WITH METAL HEAT SHIELD FOR THE GENERATOR AS REQUIRED BY 46 CFR 182.455.
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Navigation
Issued 3 May 2000 Resolved
PROVIDE FCC STATION LICENSE AS REQUIRED BY 47CFR 80.15.
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Navigation
Issued 3 May 2000 Resolved
PROVIDE NAV PUBS AS REQUIRED BY 46 CFR 184.420
Condition: Unknown
Due 3 May 2000
Resolved 3 May 2000
Lifesaving
Issued 17 February 1998 Resolved
PROPERLY REPAIR LIFEFLOATS WHERE THE COATING IS CRACKING AS PER 46 CFR 180.200.
Condition: Unknown
Due 17 March 1998
Resolved 26 March 1998
Engineering
Issued 17 February 1998 Resolved
REPAIR FUEL SHUT OFF VALVE FOR THE PORT TANK AS PER 46 CFR 176.804.
Condition: Unknown
Due 17 March 1998
Resolved 26 March 1998
Engineering
Issued 17 February 1998 Resolved
PROPERLY ADJUST BOTH SHAFT PACKING GLANDS AS PER 46 CFR 176.800.
Condition: Unknown
Due 17 March 1998
Resolved 27 April 1998
Construction/Loadline
Issued 17 February 1998 Resolved
REMOVE AND TREAT ANGLE HAIR FUNGUS IN ENGINE ROOM. SEE NVIC 7-95.
Condition: Unknown
Due 17 March 1998
Resolved 27 April 1998
Construction/Loadline
Issued 17 February 1998 Resolved
PROPERLY REPAIR SAGGING DECK PORT AND STARBOARD SIDES NEAR THE AFT END OF THE SUPERSTRUCTURE. SEE NVIC 8-87.
Condition: Unknown
Due 17 March 1998
Resolved 26 March 1998
Construction/Loadline
Issued 17 February 1998 Resolved
PROPERLY REPAIR AREA ON COLLISION BULKHEAD ON FORWARD SIDE WHERE IT TABS INTO THE DECKHEAD. SEE NVIC 8-87.
Condition: Unknown
Due 17 March 1998
Resolved 27 April 1998
Navigation
Issued 17 February 1998 Resolved
PROVE PROPER OPERATION OF THE SINGLE SIDE BAND RADIO AS PER 47 CFR 80.903(3).
Condition: Unknown
Due 17 March 1998
Resolved 27 April 1998
Construction/Loadline
Issued 17 February 1998 Resolved
INSTALL AN INSPECTION PORT IN THE DECK FORWARD OF THE COLLISION BULKHEAD TOALLOW INSPECTION OFTHE VOID. SEE 46 CFR 176.25-5(1).
Condition: Unknown
Due 17 March 1998
Resolved 27 April 1998
Construction/Loadline
Issued 17 February 1998 Resolved
PROPERLY REPAIR CRACKS AND DELAMINATION ON DECKS AND ALONG SIDE OF THE SUPERSTRUCTURE. NVIC 8-87.
Condition: Unknown
Due 17 March 1998
Resolved 26 March 1998
Lifesaving
Issued 5 May 1997 Resolved
PROVIDE ONBOARD THE VESSEL, A 406 MHZ EPIRB IN A FLOAT FREE ARRANGEMENT IAW46 CFR 180.64_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 May 1997
Resolved 25 May 1997
Lifesaving
Issued 5 May 1997 Resolved
PROPERLY INSTALL VESSEL'S PRIMARY LIFESAVING EQUIPMENT IN A FLOAT FREE ARANGEMENT._x001C_ 46 CFR 180.20-1(a)(7)_x001C_ _x001C_
Condition: Unknown
Due 18 June 1997
Resolved 18 June 1997
Lifesaving
Issued 5 May 1997 Resolved
PROVIDE THE REQUIRED CREW IN ACCORDANCE WITH THE MANNING REQUIREMENTS OF THE VESSEL'S COI._x001C_ 46 CFR 185.20-1_x001C_ 46 CFR 15.501
Condition: Unknown
Due 18 June 1997
Resolved 18 June 1997
Navigation
Issued 5 May 1997 Resolved
PROVIDE ONBOARD VESSEL, ADEQUATE AND UP TO DATE NAUTICAL CHARTS AND PUBLICATIONS THAT COVER THE VESSEL'S INTENDED AREA OF OPERATION.
Condition: Unknown
Due 18 June 1997
Resolved 18 June 1997
Documentation
Issued 5 May 1997 Resolved
PROVIDE AND POST ONBOARD VESSEL, A VALID CERTIFICATE OF INSPECTION._x001C_ 46 CFR 176.01-40
Condition: Unknown
Due 18 June 1997
Resolved 18 June 1997
Lifesaving
Issued 5 May 1997 Resolved
PROVIDE AN OPERABLE WATERLIGHT FOR EACH LIFEFLOAT._x001C_ 46 CFR 180.15-1(a)
Condition: Unknown
Due 18 June 1997
Resolved 18 June 1997
Engineering
Issued 31 March 1997 Resolved
PORT ENGINE TACHOMETER WAS INOPERATIVE. REPAIR OR REPLACE TACHOMETER IN ACCORDANCE WITH 46 CFR 182.410(b) PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 31 March 1997
Resolved 31 March 1997
Lifesaving
Issued 31 March 1997 Resolved
CREW WAS NOT ABLE TO PERFORM LIFESAVING AND FIREFIGHTING DRILLS ADEQUATELY.PERFORM DRILLS IN PRESENCE OF USCG INSPECTOR IN ACCORDANCE WITH 46 CFR 185.520 AND 185.524 PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 31 March 1997
Resolved 31 March 1997
Fire Fighting
Issued 31 March 1997 Resolved
PORTABLE FIRE EXTINGUISHER MOUNT IN ENGINEROOM IS EXCESSIVELY WASTED AND PARTED. REMOUNT EXTINGUISHER IN ACCORDANCE WITH 46 CFR 181.500(a) and 520 PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 31 March 1997
Resolved 31 March 1997
Accommodation/Occupational Safety
Issued 31 March 1997 Resolved
THE UPPER LEVEL DECK ACCESS FOR MAXIMUM PASSENGERS AS INDICATED BY THE STABILITY LETTER WAS MISSING. INSTALL MARKING IN ACCORDANCE WITH 46 CFR 185.602(g) PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 31 March 1997
Resolved 31 March 1997
Lifesaving
Issued 31 March 1997 Resolved
NO EVIDENCE WAS PROVIDED INDICATING 50% OF DECKHANDS HAD TRAINING IN CPR. PROVIDE EVIDENCE OF TRAINING IN ACCORDANCE WITH NVIC 1-91 PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 31 March 1997
Resolved 31 March 1997
Engineering
Issued 3 April 1995 Resolved
REPLACE REMOTE FUEL CUTOUT VALVES AND DEMONSTRATE OPERATION.
Condition: Unknown
Due 30 April 1995
Resolved 8 May 1995
Navigation
Issued 3 April 1995 Resolved
DEMONSTRATE OPERATION OF ANCHOR LIGHT, REPLACE HOUSEHOLD LAMP CORD.
Condition: Unknown
Due 30 April 1995
Resolved 8 May 1995
Navigation
Issued 3 April 1995 Resolved
DEMONSTRATE OPERATION OF AM/HF RADIO, VSL RESTIRCTED TO NMT 20NM FROM SHOREUNTIL CORRECTED.
Condition: Unknown
Due 30 April 1995
Resolved 8 May 1995
Electrical
Issued 16 February 1995 Resolved
INSTALL PULLEY GUARDS ON P/S MAIN ENGINES.
Condition: Unknown
Due 16 February 1995
Resolved 16 February 1995
Navigation
Issued 16 February 1995 Resolved
INSTALL DOUBLE HOSE CLAMPS ON ALL HYDRAULIC STEERING SYSTEM HOSES.
Condition: Unknown
Due 16 February 1995
Resolved 16 February 1995
Engineering
Issued 16 February 1995 Resolved
PERMANENTLY MOUNT AUX. LUBE OIL DRAIN PUMP.
Condition: Unknown
Due 16 February 1995
Resolved 16 February 1995
Electrical
Issued 16 February 1995 Resolved
INSTALL METAL SUPPORT BANDS ON ALL ELEC. CABLES AND WIRES THRU OUT VESSEL.
Condition: Unknown
Due 16 February 1995
Resolved 16 February 1995
Accommodation/Occupational Safety
Issued 16 February 1995 Resolved
INSTALL A 3/4 FULL LEVEL INDICATOR ON FWD AND AFT SEWAGE TANKS.
Condition: Unknown
Due 16 February 1995
Resolved 16 February 1995
Electrical
Issued 16 February 1995 Resolved
REMOVE ALL DEAD END WIRES THRU OUT VESSEL.
Condition: Unknown
Due 16 February 1995
Resolved 16 February 1995
Engineering
Issued 18 April 1994 Resolved
REPAIR SMALL OIL LEAK ON LUBE OIL FILTER STARBAORD MAIN ENGINE.
Condition: Unknown
Due 29 April 1994
Resolved 6 May 1994
Unknown
Issued 11 September 1992 Resolved
RENEW LINE ON RING BUOY.
Condition: Unknown
Due 21 October 1992
Resolved 21 October 1992
Electrical
Issued 18 April 1991 Resolved
REMOVE ALL DEAD END WIRES.
Condition: Unknown
Due 18 April 1991
Resolved 18 April 1991
Accommodation/Occupational Safety
Issued 18 April 1991 Resolved
NO PASSENGERS ALLOWED TOPSIDE UNTIL STABILITY TEST WITNESSED AND APPROVED BY USCG.
Condition: Unknown
Due 18 April 1991
Resolved 18 April 1991
Electrical
Issued 23 April 1990 Resolved
REMOVE ALL WIRE NUTS USED ON VESSEL AND REPLACE WITH PRESSURE TYPE CONNECTORS.
Condition: Unknown
Due 23 April 1990
Resolved 23 April 1990
Electrical
Issued 23 April 1990 Resolved
PROVIDE FACEPLATES FOR ELECTRIC REEL RECEPTACLES UNDER BULWARK OVERHANG OR REMOVE WIRING AND RECEPTACLES.
Condition: Unknown
Due 23 April 1990
Resolved 23 April 1990
Documentation
Issued 23 April 1990 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 23 April 1990
Resolved 23 April 1990
Electrical
Issued 23 April 1990 Resolved
REINSTALL LIGHT FIXTURE IN LAZARETTE.
Condition: Unknown
Due 23 April 1990
Resolved 23 April 1990
Electrical
Issued 23 April 1990 Resolved
REMOVE DEAD END WIRING IN COMPARTMENT FORWARD OF LAZARETTE.
Condition: Unknown
Due 23 April 1990
Resolved 23 April 1990
Electrical
Issued 27 April 1989 Resolved
REMOVE DEAD ENDED WIRES IN ENGINE COMPARTMENT.
Condition: Unknown
Due 27 April 1989
Resolved 27 April 1989
Electrical
Issued 27 April 1989 Resolved
STRAP UP/SUPPORT WIRE BUNDLE IN ENGINE COMPARTMENT ABOVE GENERATOR AND IN COMPARTMENT UNDER WHEEL HOUSE.
Condition: Unknown
Due 27 April 1989
Resolved 27 April 1989
Electrical
Issued 27 April 1989 Resolved
PROVE PROPER OPERATION OF LIVE WELL PUMP OR REMOVE PUMPS, WIRING AND PIPING.
Condition: Unknown
Due 27 April 1989
Resolved 27 April 1989
Construction/Loadline
Issued 22 February 1985 Resolved
INCREASE FREEING PORT AREA TO APPROXIMATELY 1420 SQUARE INCHES PRIOR TO REQUESTING A ROUTE EXTENSION TO 100 MILES.
Condition: Unknown
Due 22 February 1985
Resolved 22 February 1985
Lifesaving
Issued 22 February 1985 Resolved
PLACE 100% LIFEFLOATS ONBOARD FOR ALL PERSONS IN LIEU OF BUOYANT APPARATUS PRIOR TO REQUESTING A ROUTE EXTENSION TO 100 MILES.
Condition: Unknown
Due 22 February 1985
Resolved 22 February 1985
Engineering
Issued 22 February 1985 Resolved
REPLACE DAMAGED FLAME SCREEN IN FUEL TANK VENT.
Condition: Unknown
Due 22 February 1985
Resolved 22 February 1985
Fire Fighting
Issued 22 February 1985 Resolved
REPLACE UNDERWEIGHT DRY CHEMICAL FIRE EXTINGUISHER WITH A UL LISTED SIZE B-II.
Condition: Unknown
Due 22 February 1985
Resolved 22 February 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.