Records from 2001 to 2025. Most recent: inspection, 1 November 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 35
1 November 2025
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8259408
15 September 2025
Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8230928
23 September 2024
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8008355
3 November 2023
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7819461
25 September 2023
Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7790181
17 November 2022
Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7596257
30 November 2021
Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7359248
7 September 2021
COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7306477
22 September 2020
Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7062074
5 November 2019
Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6846340
17 September 2019
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6808695
2 October 2018
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6547621
4 December 2017
Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6317835
2 October 2017
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6274292
10 February 2017
Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6085979
21 September 2016
Deficiency Check · COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 5988975
4 December 2015
Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 5775543
6 October 2015
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 5731509
6 December 2011
Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 4201716
26 September 2011
COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 4152830
5 October 2010
Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 3863831
3 March 2010
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 3689332
18 September 2008
Re-Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 3335498
25 August 2008
Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 3308900
24 January 2008
Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 3135729
2 October 2007
Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 3070317
28 September 2006
COI Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 2788767
13 September 2005
Re-Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 2492156
16 September 2004
Re-Inspection
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 2197395
17 December 2003
Hull Examination
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 1965713
8 October 2003
Drydock Extension
Administrative · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 1923737
2 October 2003
Re-Inspection
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 1919949
9 October 2002
Re-Inspection
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 1686481
20 June 2002
Deficiency Check
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 1633910
28 September 2001
Initial Construction-Excluding Oversight · COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1457014
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 23 September 2024
Resolved
Stbd side light inop, repair replace.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 October 2024
Resolved 24 September 2024
Resolution: New Bulb installed test sat.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 25 September 2023
Resolved
A vessel on an oceans, coastwise, limited coastwise, or Great Lakes route must carry— (1) Six hand red flare distress signals; and (2) Six hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter, or other standard specified by the Commandant.
Vessel only had 4 flairs during time of inspection.
46 CFR 180.68(a)
Action required: 17 - Rectify deficiencies prior to departure
Due 25 September 2023
Resolved 26 September 2023
Resolution: Vessel sent pictures showing purchase of the additional flairs.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 25 September 2023
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules.
Vessel stern light was inoperable during time of inspection. Vessel is limited to day time operations until rectified.
46 CFR 183.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2023
Resolved 26 September 2023
Resolution: Vessel sent pictures showing deficiency rectified.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 25 September 2023
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. .
Vessels FCC Radio Certificate was expired during time of inspection. Vessel has until April 2024 when vessel goes back into the water to rectify deficiency or will be limited to 1000ft from shore.
47 CFR 80.903
Action required: 705 - Other - as specified
Resolved 12 July 2024
Resolution: Vessel sent pictures of FCC cert.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 25 September 2023
Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed. Vessel POC need to confirm date of service on EPIRD Hydrostatic release.
Vessel is done with operations for the year and would like to renew the Hydro during or after completion of dry dock to align dates with IBA Hydro Release. Vessel is limited to 3nm from shore until deficiency rectified.
Action required: 705 - Other - as specified
Resolved 12 July 2024
Resolution: Vessel sent pictures of EPIRB registration and battery exp date
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 17 November 2022
Resolved
Complete drills prior to operation in the spring 2023.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 June 2023
Resolved 23 September 2024
Resolution: Drills completed, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 7 September 2021
Resolved
Hydro release expired. Renew hydro release / limited vessel route to LBS not more than 3 Mile from shore warm water months thru Sept 31.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 September 2021
Resolved 30 November 2021
Resolution: New hydro release installed.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 21 September 2016
Resolved
Renew the vls's name on the ring buoy.
Action required: 705 - Other - as specified
Due 21 October 2016
Resolved 27 September 2016
Resolution: Rcvd documentation that markings were renewed on the lifebuoy.
Stability › Unintentional Flooding › General
Issued 21 September 2016
Resolved
High water alarm did not work in the Lazerette space; vsl to repair/replace.
Action required: 705 - Other - as specified
Due 21 October 2016
Resolved 27 September 2016
Resolution: Rcvd documentation that the Lazerette high water alarm light was repaired.
Lifesaving › Lifebuoys › Serviceable
Issued 6 October 2015
Resolved
Replace Ring Buoy.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 6 November 2015
Resolved 21 October 2015
Resolution: New ring has been purchased.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 6 October 2015
Resolved
Prove operation of anchor light.
Action required: 705 - Other - as specified
Due 6 November 2015
Resolved 21 October 2015
Resolution: O/O advised that light was not operational due to a secured breaker. Light works.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 6 October 2015
Resolved
Replace expired aspirin.
Action required: 705 - Other - as specified
Due 6 November 2015
Resolved 21 October 2015
Resolution: O/O advised that new aspirin was purchased.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 6 October 2015
Resolved
Replace expired alcohol testing kits.
Action required: 705 - Other - as specified
Due 6 November 2015
Resolved 21 October 2015
Resolution: O/O provided receipt for new kits.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 23 September 2011
Resolved
Provide current hydrostatic release unit for EPIRB.
Action required: 705 - Other - as specified
Due 26 October 2011
Resolved 27 September 2011
Engineering › Bilge Water Management System › Interface Detector
Issued 2 October 2007
Resolved
Visual alarm was inoperable for high water alarm. Master must Prove operation of visual detector on High water alarm.
*Update 17OCT07: O/O stated that he will be installing a new panel this winter. He was advised to notify this office when completed.
Action required: 705 - Other - as specified
Due 2 November 2007
Resolved 24 January 2008
Resolution: O/O has installed new panel for high water alarm. Witnessed satisfactory test of all three high water alarms both visual and audible.
Engineering › Sea-water System (primary cooling) › Piping
Issued 2 October 2007
Resolved
piping system for cooling water discharge only had one hose clamp. Master must provide double hose clamp on cooling water discharge/wet exhaust.
Action required: 705 - Other - as specified
Due 2 November 2007
Resolved 17 October 2007
Resolution: Received phone call from [name withheld] hose clamps have been installed.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 2 October 2007
Resolved
The batteries on the Floating elecetric waterlight were expired. Master must renew batteries in waterlights.
Action required: 705 - Other - as specified
Due 2 November 2007
Resolved 17 October 2007
Resolution: Received phone call from [name withheld] have been renewed.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 2 October 2007
Resolved
Line on lifefloat was inadequate length. Master must provide 18 foot line on lifefloat waterlights
Action required: 705 - Other - as specified
Due 2 November 2007
Resolved 17 October 2007
Resolution: Received phone call from [name withheld]. 18'' floating line is now in place.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 2 October 2007
Resolved
Vessel did not have current copy of U.S. Coast pilot on board. Vessel Master must Provide copy of current U.S. Coast Pilot.
*Update-17OCT07: O/O sent link for downloadable/printable version. Will verify that it was printed off at next visit.
Action required: 705 - Other - as specified
Due 2 November 2007
Resolved 25 August 2008
Resolution: O/O confirmed that he has printed off applicable section of Coast Pilot.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 2 October 2007
Resolved
Vessel did not have a plan for recording passenger count. Master must provide a means of accounting for passengers.
Action required: 705 - Other - as specified
Due 2 November 2007
Resolved 17 October 2007
Resolution: Received phone call from [name withheld] will leave the information with his wife at his office.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 2 October 2007
Resolved
Vessel first aid kit was missing asprin. Kit had expired medications (eye wash and sea sick tablets). Master must place expired first aid kit items.
Action required: 705 - Other - as specified
Due 2 November 2007
Resolved 17 October 2007
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Documentation › Certificates/Documents › FCC SSL
Issued 2 October 2007
Resolved
Vessel's FCC safety certificate was expired. Master must provide valid FCC safety certificate.
Action required: 705 - Other - as specified
Due 2 November 2007
Resolved 17 October 2007
Resolution: Received phone call from [name withheld] Certificate was issued on October 3 2007.
Lifesaving › Lifefloat › Float-free Link
Issued 13 September 2005
Resolved
PROPERLY RIG LIFEFLOATS WITH WEAK LINKS
Action required: 705 - Other - as specified
Due 20 September 2005
Resolved 13 September 2005
Resolution: LIFE FLOATS RIGGED PROPERLY
Lifesaving › Hand Flares › Quantity
Issued 13 September 2005
Resolved
PROVIDE SIX RED FLARES AND SIX DAY SMOKES
Action required: 705 - Other - as specified
Due 20 September 2005
Resolved 13 September 2005
Resolution: SIX RED FLARES AND SIX DAY SMOKES PROVIDED
Communications › Radio Communications
Issued 2 October 2003
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 16 October 2003
Resolved 2 October 2003
Construction/Loadline › Hull
Issued 2 October 2003
Resolved
COMPLETE CREDIT DRYDOCK EXAMINATION. (VESSEL MAY NOT CARRY PASSENGERS UNTIL 2-YR CREDIT DRYDOCK RECEIVED).
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 October 2003
Resolved 17 December 2003
Resolution: Drydock examination completed and 2 drydock credit granted.
Lifesaving
Issued 28 September 2001
Resolved
CONDUCT UNDERWAY DRILLS PRIOR TO THE 2002 OPERATING SEASON. THIS ITEM IS TO BE CORRECTED PRIOR TO THE CARRAGE OF PASSENGERS.
Condition: Unknown
Due 30 June 2002
Resolved 20 June 2002
Resolution: got underway with vessel to conduct man overboard drill
Construction/Loadline
Issued 28 September 2001
Resolved
INSTALL VALVES ON BILGE PUMP DISCHARGE HOSES AT HULL PENETRATIONS.
Condition: Unknown
Due 20 June 2002
Resolved 20 June 2002
Resolution: Checked valves on visit for man overboard drill
Lifesaving
Issued 28 September 2001
Resolved
ATTACH A SINGLE LANYARD FROM EACH LIFEFLOAT AND ATTACH EACH LANYARD TO A SINGLE PAINTER WITH WEAK LINK.
Condition: Unknown
Due 20 June 2002
Resolved 20 June 2002
Resolution: Checked lifesaving equipment on visit for man overboard drill