NOTHIN BUT FUN is a 1983 passenger vessel (inspected). The Coast Guard has recorded 12 inspections since 2016, most recently in March 2023, along with 20 deficiencies.

Records from 2016 to 2023. Most recent: inspection, 12 March 2023.

Built
1983
Last inspected
12 March 2023
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 12 March 2023
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2016–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDF5536
242146
Flag
UNITED STATES
Maury page id
psix-242146

Documentation record

Registered dimensions (L × B × D)64.3 ft × 28.0 ft × 7.0 ft
Registered tonnagegross 22 / net 20
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSAND CITY, CA, UNITED STATES · built 1983
Hull materialFRP (Fiberglass)
PropulsionAuxiliary Sail
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSANTA CRUZ, CA
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationValid · issued 6 May 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it20 - Regulatory (Subpart C or D), Net Ton
22 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 12

12 March 2023 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7649665
10 March 2022 Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7405339
1 December 2021 Construction Oversight · Hull Examination · Internal Structural Exam · Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7360984
1 September 2021 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7301159
28 July 2020 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7017776
5 February 2020 Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6902021
12 June 2019 Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6711588
19 June 2018 Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6442200
16 January 2018 Administrative Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6339219
28 June 2017 Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6181839
27 September 2016 Annual Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6009775
18 February 2016 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5823605

Deficiency record · 20

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 March 2022 Resolved
Compartment for stowing adult life jackets found to have two "dead end" wires. Terminate wires in a junction box and cap with pressure type connectors.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 March 2022
Resolution: Terminated wires with pressure type connectors in a junction box.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 10 March 2022 Resolved
Life floats found to be missing float free link secured to the end of the painter/vessel. Install weak link of proper strength for the size of life float and certified to meet 46CFR 160.073.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 April 2022
Resolution: POC installed new float free links rated for the appropriate size life floats.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 10 March 2022 Resolved
Ring Buoy found to be missing floating water-light. Attach floating water-light with a lanyard of at least 3 feet in length but not more than 6 feet, secure the water-light around the body of the ring with a corrosion resistant clip rated at at least 50lbs allowing for the light to be quickly disconnected.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2022
Resolved 14 March 2022
Resolution: Atending MI verified required floating water light was installed
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 10 March 2022 Resolved
Ring buoy found to be missing retro-reflective tape. Mark ring buoy with type 2 retro-reflective material approved IAW 46CFR 164.018.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2022
Resolved 25 April 2022
Resolution: POC Installed retro-reflective tape IAW 46CFR 164.018.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 March 2022 Resolved
Remote fuel shutoff markings found to be of non contrasting colors. Replace fuel shutoff instructions with clearly legible letters at least 1 inch high.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2022
Resolved 6 June 2022
Resolution: Labeled fuel shutoff locations properly; verified by MI.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 10 March 2022 Resolved
Vessel found to lack a means of shutting down ventilation to engine space when fixed gas fire extinguishing system is actuated. Provide means of shutting off ventilation to engine room spaces during fixed gas fire extinguishing.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 June 2022
Resolution: Provided means to close ventillation to space.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 10 March 2022 Resolved
Life floats found to be missing floating water lights. Each life float must be fitted with a lifeline, pendant, two paddles, a painter and a light.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 March 2022
Resolution: Verified floating water lights installed on life floats.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 December 2021 Resolved
Name of the vessel must be marked on some clearly visible exterior part of the port and starboard bow and the stern of the vessel. The hailing port of the vessel must be marked on some clearly visible exterior part of the stern of the vessel. Vessel name and hailing port do not match the COI. Update name and hailing port.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 February 2022
Resolved 28 February 2022
Resolution: Updated vessel name and hailing port on hull
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 1 December 2021 Resolved
During the examination all accessible parts of the vessel's underwater body shall be made available for examination. Damage to hull found on STBD quarter. Repair hull damage.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 February 2022
Resolved 28 February 2022
Resolution: Repaired hull damage.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 1 December 2021 Resolved
During the examination all accessible parts of the vessel's underwater body shall be made available for examination. Hull cracking found on crossbeam. Verify no internal fiberglass damage and repair area.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 February 2022
Resolved 28 February 2022
Resolution: repaired hull damage
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 1 December 2021 Resolved
Resin used must be fire retardant and meet as accepted by the Commandant as meeting NPFC MIL-R-21607E. Resin systems that have not been accepted as meeting NPFC MIL-R-21607E(SH) may be accepted as fire retardant if they have an ASTM E-84 flame spread rating of not more than 100 when tested in laminate form. Provide proof that resin used with deck insert is fire retardant.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 March 2022
Resolution: Provided proof that resin used was fire retardant. Data sheet saved to vessel file.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 1 December 2021 Resolved
If weight change exceeds 2% plus or minus vessel total weight, a new stability test SHALL be conducted. Provide total weight of installed ladder system.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 March 2022
Resolution: Provided total weight for project 622 lbs, which is 1.4% change. special note added.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 1 September 2021 Resolved
A pre-engineered fixed gas fire extinguishing system must be capable of manual activation. Activation handles at operating station are corroded. Service handles and ensure proper operation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 September 2021
Resolved 16 September 2021
Resolution: Operator sent photo of handles cleaned and serviceable.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 1 September 2021 Resolved
A pre-engineered fixed gas fire extinguishing system must be capable of manual activation. The two separate activation handles are not labeled as to which machinery space (Port or Starboard) will correspond to activation of handles. Label activation handles at primary operating station.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 September 2021
Resolved 16 September 2021
Resolution: Operator sent photo of handles labeled "P" and "S".
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 September 2021 Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford adequate protection against hazards that might endanger the vessel and the persons being transported. Seizing wire missing on mainsheet system. Seize all shackles in mainsheet system.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 September 2021
Resolved 16 September 2021
Resolution: Operator sent photos of mainsheet blocks seized with wire.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 September 2021 Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford adequate protection against hazards that might endanger the vessel and the persons being transported. Baby Stay is missing cotter pin in turnbuckle. Ensure rig tune and install cotter pin.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 September 2021
Resolved 16 September 2021
Resolution: Operator sent photo of cotter pins installed in baby stay turnbuckle.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 1 September 2021 Resolved
As appropriate for intended voyage, a vessel must carry adequate and up to date: U.S. Coast Pilot or similar and Coast Guard Light List. Vessel has outdated U.S. Coast Pilot. Vessel does not carry official Coast Guard Light List. Provide publications onboard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 September 2021
Resolved 16 September 2021
Resolution: Operator provided photos of Coast Pilot and Tide Tables.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 12 June 2019 Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. Vessel is required to have valid up to date certificates. FCC Radiotelephony Certificate has been expired since August 2018. 47 CFR 80.903
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2019
Resolved 9 July 2019
Resolution: Received copy of the updated certificate.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 12 June 2019 Resolved
EAP education program: Each EAP education program must include at least the following elements: display and distribution of informational material; display and distribution of a community service hot-line telephone number for crewmember assistance, and display and distribution of the employer's policy regarding drug and alcohol use in the workplace. Vessel does not have required EAP program documentation posted.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2019
Resolved 9 July 2019
Resolution: Received proof of posting the EAP assistance number.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 12 June 2019 Resolved
Life floats and buoyant apparatus must not be stowed in tiers more than 1,220 millimeters (4 feet) high. When stowed in tiers, the separate units must be kept apart by spacers.Vessel's stacking lifefloats must separate the lifefloats with spacers. Vessel's lifefloat stacks do not have spacers between them.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2019
Resolved 9 July 2019
Resolution: Saw spacers.

Ownership record