MAURY USCG vessel records
← All vessels

VIRGINIAN

Built
1983
Last inspected
8 June 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.

Inspection record

Last inspected 8 June 2026
…with no type recorded19
Operational controls None recorded without a removal date
Years with a record 36 calendar years (1987–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDF6332
242476
Flag
UNITED STATES
Tonnage
1100 - Simplified, Gross Ton 1100 - Simplified, Net Ton 2052 - Dead Weight, Ton
Maury page id
psix-242476
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. Only barges and towing vessels are in this archive, so any other vessel type in the same activity does not appear here: these lists are a floor, not a complete manifest.

ELIZABETH ANN Towing Vessel · MISLE 211711 · 8 November 2022 · activity 7592426MISS CATE Towing Vessel · MISLE 231407 · 30 June 2020 · activity 6992874MISS CATE Towing Vessel · MISLE 231407 · 23 October 2016 · activity 6031536MERIDIAN Towing Vessel · MISLE 111947 · 3 November 2002 · activity 1700547

Inspection history · 80

8 June 2026 Deficiency Check · COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8394756
6 January 2026 Deficiency Check · Internal Structural Exam · Vessel Attendance · Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8290526
11 June 2025 Annual Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8157204
7 November 2024 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8032168
14 August 2024 Periodic Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7977719
31 July 2023 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7756950
12 July 2023 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7740527
27 December 2022 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7612254
8 November 2022 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7592426
9 September 2022 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7556809
20 April 2021 Examination of Repairs · Internal Structural Exam · COI Inspection · Drydock Exam · Hull Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7178925
30 June 2020 Administrative Inspection · Damage Survey · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6991670
30 June 2020 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6992874
23 September 2019 Administrative Inspection · Plan Review (Other than "T") · Special
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6839599
29 April 2019 Periodic Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6663545
16 July 2018 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6481302
1 June 2018 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6431531
2 March 2018 Hull Examination · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6364220
5 July 2017 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6198834
5 June 2017 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6165098
23 October 2016 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6031536
25 August 2016 In-Service Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 5982841
14 June 2016 COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5902551
26 April 2016 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5863294
23 March 2016 Hull Examination · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5838465
11 September 2015 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5232067
26 August 2015 Type not recorded
No type recorded · Station Charleston · USCG Southeast District (CGD-SE) · Activity 5227764
10 September 2014 Periodic Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4979491
13 November 2013 Annual Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4747738
26 November 2012 Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 4490390
24 August 2011 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 4126181
19 August 2011 COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4120750
22 December 2010 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3911346
25 October 2010 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3878756
16 September 2009 Periodic Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3595393
13 May 2009 Drydock Exam · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3473870
14 October 2008 Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3344199
3 January 2008 Examination of Repairs · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3124007
29 December 2007 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3128228
4 December 2007 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3104729
16 July 2007 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2997189
26 March 2007 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2946603
23 October 2006 Administrative Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2806201
18 September 2006 COI Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2780864
8 May 2006 In-Service Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2643990
14 February 2006 Administrative Inspection
Administrative · USCG East District (dp) · USCG East District (CGD-E) · Activity 2584960
8 August 2005 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2448812
28 September 2004 Hull Examination · Internal Structural Exam
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2206978
7 September 2004 Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2190541
2 August 2004 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2153500
15 July 2003 Periodic Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1847166
29 January 2003 Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1736776
3 November 2002 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1700547
28 May 2002 Administrative Inspection
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1621811
12 December 2001 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1405303
16 May 2001 Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1454947
6 May 2001 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 70327
30 April 2001 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1061867
6 April 2001 Drydock Extension
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1062609
26 September 2000 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1408598
10 December 1999 Hull Examination · COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1393273
20 October 1999 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 791562
26 July 1999 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1106610
19 May 1999 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 802082
7 May 1998 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1126349
6 May 1998 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1416706
11 July 1997 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1114052
30 June 1997 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1392720
20 May 1996 Hull Examination · COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1460869
3 August 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 642873
28 July 1995 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 871802
30 May 1995 Deficiency Check · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1427072
29 September 1994 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 863724
26 May 1994 COI Inspection · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1403795
15 March 1994 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 642869
16 July 1993 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 848272
24 July 1992 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1269348
29 May 1992 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1257446
4 May 1987 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1315747
12 March 1987 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1323592

Deficiency record · 106

11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 8 June 2026 Resolved
Each cargo vessel must carry an immersion suit approved under approval series 160.171 of an appropriate size for each person on board. Vsl had no immersion suits on board. 46 CFR 199.273 (a)
Action required: 705 - Other - as specified
Resolved 30 June 2026
Resolution: VSl obtained required Immersion Suits
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 2 September 2025 Resolved
No repairs or alterations affecting the safety of the vessel with regard to the hull, machinery, or equipment, shall be made without the knowledge of the Officer in Charge, Marine Inspection. During deficiency check MI identified new steel repair in vicinity of the locker room and the exterior portside aft hull bulkhead in way of the tug notch that was not reported to the Coast Guard. 46 CFR 91.45-1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 October 2025
Resolved 22 September 2025
Resolution: Received class survey report attesting to satisfactory repair and testing.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 11 June 2025 Resolved
All vessels shall have efficient guard rails or bulwarks on decks and bridges. There are no rails present on the port aft side of the deck located on top of the accommodation space due to missing mate’s shack. Replace mate’s shack or install compliant rails prior to dredging operations. 46 CFR 92.25-5(a), 705c prior to operations.
Action required: 705 - Other - as specified
Resolved 22 September 2025
Resolution: Received objective evidence that shack had been replaced and welded.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 11 June 2025 Resolved
Where the extinguishing agent can be released by remote control, the system must have a manual local control at the cylinders. Fixed halon firefighting system can be released by remote controls located near the entrance/exit of the protected space. Release instructions direct the actuator to “proceed to the FM-200 local actuation station and follow the operation instructions.” There are no operation instructions posted locally at the FM-200 bottles, nor was the crew in attendance aware of how to actuate the system locally. Rectify prior to dredging operations. 46 CFR 95.15-5(a), 705 prior to operations
Action required: 705 - Other - as specified
Resolved 2 September 2025
Resolution: Verified signage and instructions were correct.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 11 June 2025 Resolved
The owner of a vessel subject to inspection under section 3301 shall: (1) ensure that such vessel is equipped with a vessel master key control system, manual or electronic, which provides controlled access to all copies of the vessel’s master key of which access shall only be available to the individuals described in paragraph (2); (2) establish a list of all crew, identified by position, allowed to access and use the master key and maintain such list upon the vessel, within owner records and included in the vessel safety management system; (3) record in a log book information on all access and use of the vessel’s master key, including—dates and times of access; the room or location accessed; and the name and rank of the crew member that used the master key; and (4) make the list under paragraph (2) and the log book under paragraph (3) available upon request to any agent of the Federal Bureau of Investigation, any member of the Coast Guard, and any law enforcement officer performing official duties in the course and scope of an investigation. Vessel is not equipped with a vessel master key control system and log book. 46 USC 3106, 50c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 July 2025
Resolved 5 September 2025
Resolution: Reviewed master key log procedures and verified all elements were accounted for.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 11 June 2025 Resolved
On a merchant vessel of the United States the construction of which began after March 4, 1915: (5) each crew berthing area shall be equipped with information regarding- (A) vessel owner or company policies prohibiting sexual assault and sexual harassment, retaliation, and drug and alcohol usage; and (B) procedures and resources to report crimes, including sexual assault and sexual harassment, including information- (i) on the telephone number, website address, and email address for reporting allegations of sexual assault and sexual harassment to the Coast Guard; (ii) on vessel owner or company procedures to report violations of company policy and access resources; (iii) on resources provided by outside organizations such as sexual assault hotlines and counseling; (iv) on the retention period for surveillance video recording after an incident of sexual harassment or sexual assault is reported. Crew berthing areas were not equipped with the required information. 46 USC 11101, 50c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 July 2025
Resolved 2 September 2025
Resolution: Verified signage was posted for company and CG reporting.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 11 June 2025 Resolved
The provisions of this subpart apply to all industrial vessels of 300 gross tons or more but less than 4,000 gross tons, contracted for on or after July 1, 1968, which carry in excess of 12 industrial personnel. The boundary bulkheads separating the accommodations from galleys shall be of “A” Class construction. The two doors separating the galley space from to the accommodation space were not of “A” class construction. 46 CFR 92.07-1(b), 46 CFR 92.07-10, 50c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 July 2025
Resolved 2 September 2025
Resolution: Verified crew accomodations are now below 12 industrial personnel, so that the SFP is no longer required.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 June 2025 Resolved
Each battery deck box must be weathertight. The battery deck box located on top of the accommodation space is wasted such that it is no longer weathertight. 46 CFR 111.15-10, 50c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 July 2025
Resolved 19 August 2025
Resolution: Received objective evidence battery box was renewed to be weathertight.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 11 June 2025 Resolved
Electric installations on vessels must ensure protection of passengers, crew, other persons, and the vessel from electrical hazards. There were dead end wires located on the second level of the crane house, stbd side. Corrected on the spot. 46 CFR 111.01(a)(2), 10c
Action required: 10 - Deficiency Rectified
Resolved 11 June 2025
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 14 August 2024 Resolved
Each life raft must be stowed to permit manual release from its securing arrangement. Life rafts are stowed on top of the accommodation house unable to be launched from their stowage location into the water. 46CFR199.130(c)(1)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 September 2024
Resolved 28 August 2024
Resolution: Liferafts moved to main deck allowing them to actually be launched. Safety Plan updated and stamped.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 14 August 2024 Resolved
On vessels in Oceans and coastwise service, suitable storm rails shall be installed in all passageways. Handrails on stairwell heading down to engineering space were wasted and holed. 46CFR92.25-10(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 September 2024
Resolved 28 August 2024
Resolution: New Handrails welded and installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 14 August 2024 Resolved
Openings in enclosed deck houses or super structure shall be protected for weather tightness. Wastage hole in office overhead. 46CFR42.15-40(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 September 2024
Resolved 18 February 2026
Resolution: Wastage hole clad welded to MI satisfaction.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 14 August 2024 Resolved
Openings in enclosed deck houses or super structure shall be protected for weather tightness. Wastage holes in exhaust trunk. 46CFR42.15-40(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 September 2024
Resolved 18 February 2026
Resolution: Exhaust trunk wastage holes cropped and renewed to ABS/Coast Guard satisfaction.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 14 August 2024 Resolved
Nothing in this subpart shall be construed as limiting inspector from making such tests or inspections as he deems necessary to be assured of the safety of the vessel. Descale & Provide UT shots in 8" x 8" pattern in deck of exhaust trunk. 46CFR91.25-50
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 September 2024
Resolved 18 February 2026
Resolution: Area has been cropped and renewed to CG and ABS satisfaction.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 August 2024 Resolved
All piping shall run insight whenever practicable, protected against mechanical injury and secured to against excessive movement and vibration. Piping supports missing for fuel supply & return lines in Crane Tub. 46CFR56.50-70(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 September 2024
Resolved 28 August 2024
Resolution: Piping clamps installed.
04 - Emergency Systems › N/A - No Subsystem › Low level lighting in corridors
Issued 14 August 2024 Resolved
The construction of each lighting fixture for non-hazardous area must meet UL 1598A or IEC 60092. LED Light above wire spool in crane tub was missing cover and had multiple bulbs not illuminate. 46CFR111.75-20(a)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 September 2024
Resolved 28 August 2024
Resolution: New light installed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 14 August 2024 Resolved
Openings in enclosed deck houses or super structure shall be protected for weather tightness. STBD Mate shack is wasted away. Remove or C/R at next drydock. 46CFR42.15-40(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 August 2024
Resolved 6 January 2026
Resolution: Mate shack has been replaced.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 19 July 2023 Resolved
Nothing in this subpart shall be construed as limiting the inspector from making such tests and inspections as he deems necessary to be assured to the seaworthiness of the vessel. IAW 47 CFR 80.103 when using DSC (digital selective calling) techniques, coast stations and ship stations must use maritime mobile service identities (MMSI) assigned by the commission. The vessels VHF radio is not currently connected to GPS and the MMSI is not input into the radio. Correct installation to allow for the DSC button to properly notify when pressed during an emergency. 46 CFR 91.27-15
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2023
Resolved 11 June 2025
Resolution: Verified MMSI number and connectivity to GPS
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 18 July 2023 Resolved
Approved hand portable fire extinguishers and semiportable fire extinguishing systems shall be installed in accordance with Table 95.50–10(a). Portable Fire extinguishers were observed not installed in brackets. 46 CFR 95.50-10
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2023
Resolved 31 July 2023
Resolution: Installed in proper brackets.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 July 2023 Resolved
Each marine shipboard cable must meet all the requirements for construction and identification of either IEEE 1580, UL 1309, IEC 60092-353, or NPFC MIL-C-24640A or NPFC MIL-C-24643A. Connections made to battery in port control house were without any type of lug, just bare wire wrapped around threaded battery post. 46 CFR 111.60-1
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2023
Resolved 31 July 2023
Resolution: Battery removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 July 2023 Resolved
Each battery tray must be chocked with wood strips or their equivalent to prevent movement. Battery noted in deficiency No. 03 was not installed in a tray. 46 CFR 111.15-5
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2023
Resolved 31 July 2023
Resolution: Battery removed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 July 2023 Resolved
Each marine shipboard cable must meet all the requirements for construction and identification of either IEEE 1580, UL 1309, IEC 60092-353, or NPFC MIL-C-24640A or NPFC MIL-C-24643A. Bushing for wire penetration entering HVAC unit on top deck was pulled free from installation. 46 CFR 111.60-1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2023
Resolved 31 July 2023
Resolution: Properly wired and repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 July 2023 Resolved
Each marine shipboard cable must meet all the requirements for construction and identification of either IEEE 1580, UL 1309, IEC 60092-353, or NPFC MIL-C-24640A or NPFC MIL-C-24643A. Conduit for wiring to emergency lighting battery bank was disconnected at union on top deck, outboard of fixed halocarbon stowage. 46 CFR 111.60-1
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2023
Resolved 24 July 2023
Resolution: Repaired sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 July 2023 Resolved
Each lifebuoy must be marked in block capital letters with the name of the vessel and the name of the port required to be marked on the stern of the vessel. 46 CFR 199.70 (a)(2)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2023
Resolved 31 July 2023
Resolution: All marked and properly mounted.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 18 July 2023 Resolved
Branch lines connected to the fire main for purposes other than fire and deck wash shall be so arranged that adequate water can be made continuously available for firefighting purposes. Valve for branch line off of Fire Station 2 was missing a handle and could not be closed. 46 CFR 95.10-5 (f)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2023
Resolved 31 July 2023
Resolution: Handle replaced.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 July 2023 Resolved
An aggregate of more than 7.6 liters (two gallons) of flammable or combustible liquids stowed outside of an accommodation, control, or service, space (other than a paint locker) or outside of a machinery space must be stowed in a paint locker. Several cans were found stowed just outside of aft paint locker. 46 CFR 147.45 (b)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2023
Resolved 31 July 2023
Resolution: All items placed inside of paint locker and new safety chain installed on rail.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 18 July 2023 Resolved
A ship of 300 gross tons or more constructed after June 30, 1974 must have a fixed container or enclosed deck area under or around each fuel oil...fill pipe. Both diesel fill pipe connections were noted extending beyond the containment and the drain plug for the port side containment was missing. 46 CFR 155.320
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2023
Resolved 31 July 2023
Resolution: Fill pipes moved to inside of the containment.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 July 2023 Resolved
Each fire hydrant must have at least one length of firehose, a spanner wrench, and a hose rack or other device for stowing the hose. Fire Stations Nos. 5 and 6 were missing spanner wrenches. 46 CFR 95.10-10 (g)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2023
Resolved 31 July 2023
Resolution: All stations have spanner wrenchs installed.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 18 July 2023 Resolved
Sufficient illumination must be provided by the emergency lighting source under emergency conditions to effect damage control procedures and to provide for safe egress from each space. Emergency lighting at base of internal accommodation stairway was inoperable. 46 CFR 111.75-15 (c) (2)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2023
Resolved 31 July 2023
Resolution: Emergency light tested sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 July 2023 Resolved
Each cargo vessel must carry the number of lifebuoys prescribed in table 199.271 of this section (a vessel of under 100 meters must carry a total of 8). Vessel outfitted with 6. Vessel route is for "Oceans" and does not qualify for alternative (6) allowed by § 199.640. 46 CFR 199.271
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2023
Resolved 31 July 2023
Resolution: Eight on board and properly mounted.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for rating for watchkeeping
Issued 18 July 2023 Resolved
The holder of a credential may not voluntarily part with it or place beyond his or her personal control by pledging or depositing it with any other person. Vessel's Certificate of Inspection requires that there be two certified life boatman on board when the vessel is manned. The life boatman was unable to show proof of his credential and will need to have credential on board the vessel to the satisfaction of the attending MI. 46 CFR 10.233
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2023
Resolved 31 July 2023
Resolution: Two on board and varified MMC.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 July 2023 Resolved
All vessels except unmanned barges shall be provided with a satisfactory bilge pumping plant capable of pumping from and draining any water tight compartment. The suction point in the aft section of the Port spud room was unable to draw suction. Demonstrated suction from this point to the satisfaction of the attending MI. 46 CFR 56.50-50 (a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2023
Resolved 31 July 2023
Resolution: Tested sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 July 2023 Resolved
Each bilge suction must lead from a manifold except as otherwise approved by MSC. As far as practicable, each manifold must be in or be capable of remote control operations from the same space as the bilge pump that normally takes suction on the manifold. The bilge suction manifold labeling is covered in grime and paint, renew or clean to the satisfaction of the attending MI. 46 CFR 56.50-50 (c) (1)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2023
Resolved 31 July 2023
Resolution: New labels placed on valves.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 18 July 2023 Resolved
Alarm details- Be provided with a means to test audible and visual annunciators. The ship service diesel generator alarms required by 46 CFR 62.35-50 were tested and have a visual annunciator but the audible annunciator is OOC, repair or replace to the satisfaction of the attending MI. 46 CFR 62.25-20 (e) (iii)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2023
Resolved 31 July 2023
Resolution: Audible alarm installed and tested.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 18 July 2023 Resolved
There shall be at least two means of escape from all general areas accessible to the passengers, if carried, or where the crew may be quartered or normally employed. At least one of these two means of escape shall be independent of watertight doors. Both Port and STBD spud rooms have an escape scuttle and ladder way that are located on the other side of the winch. Persons would be required to move over the top of moving machinery to exit the space in the event of an emergency. Install a means to escape safely to the satisfaction of the attending MI at the vessel's next dry dock. 46 CFR 92.10-5
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 18 February 2026
Resolution: Escape hatches and ladders relocated to allow crew to escape from spaces withough having to move over exposed machinery.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 July 2023 Resolved
Each generator switch board must have a disconnect switch or link for each generator conductor. Vessel is not set up for parallel operations, there is not a safety interlock on either switch for the 2 gen sets, off line generator is to be locked out to prevent inadvertent closure of the switch. Corrected on the spot. 46 CFR 111.30-25
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 18 July 2023
Resolution: Placed lock out tag out control on stand by generator.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 13 July 2020 Resolved
The applicable standards established by the ABS Steel Vessel Rules (incorporated by reference, see 46 CFR 58.03-1), may be used as the standard for the design, construction, and testing of main and auxiliary machinery except as modified in this subchapter. 3412 Generator/HPU has fuel leak from double jacketed fuel system and missing guards.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2020
Resolved 4 August 2020
Resolution: Vessel replaced fuel line on 3412 with satisfactory results
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 13 July 2020 Resolved
Approved hand portable fire extinguishers and semiportable fire extinguishing systems shall be installed on all vessels, as set forth in subpart 95.50. Paint locker CO2 needs to be serviced
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2020
Resolved 4 August 2020
Resolution: Fire extinguisher was serviced and hose and union replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 13 July 2020 Resolved
An automatic emergency lighting and power system is one in which a reduction in potential from the ship's service power and lighting. E/R e-light was extinguished
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2020
Resolved 4 August 2020
Resolution: Replaced emergency light and conducted satisfactory test
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 13 July 2020 Resolved
The applicable standards established by the ABS Steel Vessel Rules (incorporated by reference, see 46 CFR 58.03-1), may be used as the standard for the design, construction, and testing of main and auxiliary machinery except as modified in this subchapter. Crane hoist engine has hydraulic oil leak and oil leak on the turbo.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2020
Resolved 4 August 2020
Resolution: vessel replaced gasket, oil leak stopped on 3512 Cat hoist eng
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 13 July 2020 Resolved
Suitable hand covers, guards, or rails shall be installed in way of all exposed and dangerous places such as gears, machinery, etc. Crane main engine is missing guards
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2020
Resolved 4 August 2020
Resolution: Guards around machinery were installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 July 2020 Resolved
A nonmetallic expansion joint must be replaced 10 years after it has been placed into service if it is located in a system which penetrates the side of the vessel and both the penetration and the nonmetallic expansion joint are located below the deepest load waterline. Expansion joints were installed in 2009.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2020
Resolved 9 September 2020
Resolution: Vessel installed new expansion joints.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 13 July 2020 Resolved
Approved fire extinguishing systems may be used or required in locations delineated in this section on the following vessels. FM-200 system was overcharged due to heat in storage location.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2020
Resolved 4 August 2020
Resolution: FM 200 system has a vent installed to prevent heat build up
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 13 July 2020 Resolved
Strainers. A suitable twin strainer shall be fitted in the fuel supply line in the engine compartment. Strainers shall be of the type opening on top for cleaning screens. A drip pan shall be fitted under the strainer. 3412 Strainer has drain valve that can not be plugged and leaking.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2020
Resolved 4 August 2020
Resolution: Ball valve and plug have been installed on Racor bowl to prevent leaking
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 13 July 2020 Resolved
Each production device must be legibly marked in accordance with paragraph (b) of this section with the following information: (1) The name of the manufacturer. (2) The name and model number of the device. (3) The month and year of completion of manufacture. (4) Serial number. (5) Whether the device is certified for use on an inspected or an uninspected vessel. Placard is missing
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2020
Resolved 13 July 2020
Resolution: Vessel recieved new MSD label from MFG
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 13 July 2020 Resolved
Each device must have a placard suitable for posting on which is printed the operating instructions, safety precautions, and warnings pertinent to the device. The size of the letters printed on the placard must be one-eighth of an inch or larger. Placard is missing
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2020
Resolved 13 July 2020
Resolution: Vessel installed new operating instruction on the MSD unit.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 July 2020 Resolved
Twist-on type of connectors may not be used for making joints in cables, facilitating a conductor splice, or extending the length of a circuit. Embarkation lighting battery box had multiple wire nuts installed.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2020
Resolved 4 August 2020
Resolution: wire nuts have been removed and suitable connectors have been installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 July 2020 Resolved
Each general emergency alarm signal must be marked “GENERAL ALARM—WHEN EMERGENCY ALARM SIGNAL RINGS GO TO YOUR STATION” in red letters at least 1/2 inch high. General alarm markings were missing.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2020
Resolved 4 August 2020
Resolution: General alarm placards have been installed.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 13 July 2020 Resolved
The general construction of the vessel shall be such as to minimize fire hazards insofar as is reasonable and practicable. engines have plastic oil catch cans which are a fire hazard.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2020
Resolved 4 August 2020
Resolution: Plastic catch cans have been removed
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 13 July 2020 Resolved
The load line certificates for which the Government of the United States of America assumes full responsibility may be issued by the Commandant, the American Bureau of Shipping, or a recognized classification society when appointed as an authorized assigning and issuing authority for specifically designated vessels. Can not operate beyond boundary line till Load Line Certificate is endorsed.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 14 July 2020
Resolution: Class endorsed the load line certifcate
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 3 July 2020 Resolved
A survey, either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel or the efficacy or completeness of its lifesaving appliances, fire-fighting or other equipment, or whenever any important repairs or renewals are made. The survey shall be such as to insure that the necessary repairs or renewals have been effectively made, that the material and the workmanship of such repairs or renewals are in all respects satisfactory, and that the vessel complies in all respects with the regulations in this subchapter. Ensure all machinery and its vital components are installed as per applicable CFR requirements, manufacture requirements and safe to operate. Prove proper operation of all emergency lighting. Prove all required fire extinguishing appliance are ready for use. Ensure all items are cleared prior to operations.
Action required: 705 - Other - as specified
Due 17 July 2020
Resolved 13 July 2020
Resolution: Inspection of repairs conducted during annual inspection.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Health protection, medical care?)
Issued 30 June 2020 Resolved
A damage survey shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel. Damage survey must be conducted for fire onboard prior to operating. Crew member tested positive for COVID-19 after direct contact with other personnel onboard. Vessel deemed unsafe/hazardous for Marine Inspectors. Provide sufficient COVID-19 mitigation plan to allow for proper damage survey of vessel.
Action required: 705 - Other - as specified
Due 1 July 2020
Resolved 3 July 2020
Resolution: Exam completed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 June 2020 Resolved
The lifejackets stowage positions must be marked with the words “LIFEJACKETS” or “CHILD LIFEJACKETS” as appropriate, or with the appropriate symbol from IMO Resolution A.760(18). Stowage locations not marked.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2020
Resolved 4 August 2020
Resolution: appropriate symbol from IMO Resolution A.760(18)was installed to mark stowage location.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 April 2019 Resolved
It shall be the duty of the owner, master, or person in charge to require and have performed at least once in every 12 months the tests and inspections of all hand portable fire extinguishing systems. Found more than half portable fire extinguishers not serviced. (46 CFR 97.15-60(b))
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 May 2019
Resolution: All portable fire extinguishers had been serviced and this was verified by a current servicing certificate.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 29 April 2019 Resolved
No repairs or alterations affecting safety of the vessel with regard to hull, machinery, or equipment shall be made without the knowledge of OCMI. Found two unapproved repairs and one bolt welded onto fire line. (46 CFR 91.45-1(a))
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 May 2019
Resolution: Fire main had been repaired. Witnessed a hydrostatic test of the fire main at 1.5 times the working pressure; 195 psi for ten minutes, all connections and welds were inspected for leak tightness; all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 April 2019 Resolved
Electrical installations on vessels must ensure protection of passengers, crew, other persons, and the vessel from electrical hazards. Found screen on generator 3412 dirty; caked with residue. (46 CFR 111.01-1(a)(2))
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2019
Resolved 3 May 2019
Resolution: Generator was cleaned and inspected satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 April 2019 Resolved
At least one-half the total number of lifebuoys on the vessel must each be fitted with a self-igniting light approved under approval series 161.010. The self-igniting light may not be attached to the lifebuoys required by this section to be fitted with lifelines. Found all ring life buoys fitted with both self-igniting lights and lifelines. (46 CFR 199.70(a)(3)(ii))
Action required: 10 - Deficiency Rectified
Resolved 29 April 2019
Resolution: Mate went around vessel to fix deficiency while inspectors were still onboard the vessel.
Construction/Loadline › Hull › Side Shell
Issued 2 March 2018 Resolved
Complete remaining worklist items prior to operating under the authority of COI and to the satisfaction of the attending CG Marine Inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 April 2018
Resolved 12 April 2018
Resolution: All Work list items have been completed
Documentation › Certificates/Documents › Permit, Other
Issued 2 March 2018 Resolved
The submitted welding procedure for the welding of the vessel's seawater piping system called for a backing strip to be utilized. The seawater pipes were subsequently welded without backing strips in place. The removal of the backing strips is considered a change of an essential vairable as defined in ASME IX QW-400. Resubmit an approved welding procedure without the use of a backing strip along with corresponding welder qualifications for the procedure once it is tested and approved. Upon receipt of this documentation the seawater piping repairs will be considered permanent.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2018
Resolved 1 June 2018
Resolution: Vessel rep provided updated welding certificates approved by ABS for the welding conducted on vessel's seawater piping without the use of backing strips.
Engineering › Pressure Vessel › Safety Valve
Issued 5 June 2017 Resolved
Pressure vessel safety valves shall meet service requirements for which they are intended. Safety valve did not adequately relieve excess pressure as designed. Provide servicing to valve to the satisfaction of the attending CGMI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 July 2017
Resolved 5 July 2017
Resolution: Witnessed pop test on 02 air receivers relief valves, one in the engine room set at 179 psi and one in crane set at 200 psi;
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 5 June 2017 Resolved
There must be enough receptical outlets throughout vessel for electrical equipment for safe operation. Remove daisy chain wiring and provide sufficient electrical outlets to the satisfaction of the attending CGMI.
Action required: 705 - Other - as specified
Due 5 July 2017
Resolved 5 July 2017
Resolution: Examined electrical equipment located in the crew birthing areas; all daisy chain wiring was removed and all 120V electrical receptacle 2gang outlets were replaced to 4gang. Wiring circuits were tested and schematics were reviewed for proper circuit break
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 13 November 2013 Resolved
Provide proof of crew members enrollment in a random drug testing program.
Due 27 November 2013
Resolved 15 November 2013
Resolution: Received crew enrollment list from Taylor Made Diagnostics; Cleared CG-835.
Lifesaving › Lifebuoys › Stowage
Issued 13 November 2013 Resolved
Two life buoy storage areas are not properly labeled. Label life buoy storage area.
Due 20 November 2013
Resolved 14 November 2013
Resolution: Life buoys were moved out of storage area and are now mounted on a bulkhead. Cleared CG-835.
Lifesaving › Lifebuoys › Serviceable
Issued 13 November 2013 Resolved
3 life buoys require additional reflective tape. Repair or renew 3 life buoys.
Due 20 November 2013
Resolved 14 November 2013
Resolution: Inspected new life buoys; all sat. Cleared CG-835.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 13 November 2013 Resolved
Lifejacket donning placard missing. Provide proper placard.
Due 20 November 2013
Resolved 14 November 2013
Resolution: Vessel rep installed new lifejacket donning placard. Cleared CG-835.
Electrical › Lighting (service) › Lighting Feeder
Issued 13 November 2013 Resolved
Permanently wire lights in crane machinery room.
Due 20 November 2013
Resolved 14 November 2013
Resolution: Inspected lighting in crane machinery room; all sat. Cleared CG-835.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 25 October 2010 Resolved
Hydrostatic test date is past due. Vessel to conduct a test at 1 1/4% MAWP. Amend COI, inspection status, to reflect the correct hydro dates.
Action required: 705 - Other - as specified
Due 25 November 2010
Resolved 22 December 2010
Resolution: Witnessed hydro test of supply air receiver at 1 1/2% MAWP (375 PSI), test sat.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 25 October 2010 Resolved
Retro reflective material has deteriorated beyond service. Replace with new.
Action required: 705 - Other - as specified
Due 25 November 2010
Resolved 22 December 2010
Resolution: Witnessed replacement of retro reflective material.
Engineering › Diesel Engine (auxiliary) › Injector (fuel injection)
Issued 14 October 2008 Resolved
Repair fuel leak on main generator.
Due 17 October 2008
Resolved 17 October 2008
Resolution: Repaired
Communications › Alarms/Indicators › High Water Alarm
Issued 14 October 2008 Resolved
Repair cooling water sensor.
Due 17 October 2008
Resolved 17 October 2008
Resolution: Installed new sensor.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 4 December 2007 Resolved
Prove proper operation of ground detection system to the satisfaction of the attending marine inspector in accordance with 46 CFR 111.05-21
Action required: 705 - Other - as specified
Due 4 January 2008
Resolved 3 January 2008
Resolution: Proved proper operation of ground detection system.
Electrical › Lighting (service) › Lighting Fixture
Issued 4 December 2007 Resolved
Provide guards for the fluorescent lights in the machinery space to the satisfaction of the attending marine inspector in accordance with 46 CFR 111.75-20.
Action required: 705 - Other - as specified
Due 4 January 2008
Resolved 3 January 2008
Resolution: Provided guards for all of the flourescent lights in the machinery space.
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 11 October 2006 Resolved
Provide proof of a valid COFR as the current certificate will expire on 15 OCT 2006.
Action required: 705 - Other - as specified
Due 15 October 2006
Resolved 23 October 2006
Resolution: Inspected validated COFR
Lifesaving › Rescue Boat › Carriage Requirement
Issued 11 October 2006 Resolved
Provide proof of a rescue boat prior to the carriage of industrial personnel. The boat was left on the pier in Charleston during the dry dock period.
Action required: 705 - Other - as specified
Due 10 November 2006
Resolved 1 November 2006
Resolution: Rescue boat placed back on deck
Lifesaving › Rescue Boat Equipment › Whistle/Sound Signal
Issued 11 October 2006 Resolved
Provide proof of ALL required rescue boat equipment prior to the carriage of industrial personnel. All the equipment was left in Charleston during dry dock period.
Action required: 705 - Other - as specified
Due 10 November 2006
Resolved 1 November 2006
Resolution: Corrected
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 14 February 2006 Resolved
Company is required to have names of Substance Abuse Professionals in case employees need assistance. Employer was making it the responsibility of the employee to seek this information on their own, which is not the responsibility of the employee.
Due 7 March 2006
Resolved 13 April 2006
Resolution: Documentation/Information was sent to District DAPI by [name withheld] Issued Ltr April 13th 2006 stating compliance.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 14 February 2006 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 7 March 2006
Resolved 13 April 2006
Resolution: Documentation/Information was sent to District DAPI by [name withheld] Issued Ltr April 13th 2006 stating compliance.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 14 February 2006 Resolved
Company has not submitted MIS reports to US Coast Guard since conducting chemical testing.
Due 7 March 2006
Resolved 13 April 2006
Lifesaving › Lifebuoys › Quantity
Issued 8 August 2005 Resolved
Provide two lifebuoys for a total of six lifebuoys IAW vessel COI.
Due 15 August 2005
Resolved 11 August 2005
Resolution: Vessel rep provided digital pictures of the two additional lifebuoy installations.
Fire Fighting › Means of Escape › Number
Issued 15 July 2003 Resolved
Provide proposal to USCG, addressing emergency escape routes & exit arrangement in machinery space. Existing escape routes & scuttles blocked by spud winches.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 15 August 2003
Resolved 29 July 2004
Resolution: Installed new escape hatch.
Engineering › Diesel Engine (propulsion-electric) › Nozzle, Injection (fuel injection)
Issued 29 January 2003 Resolved
racor fuel filter missing flame bowl
Due 29 January 2003
Resolved 29 January 2003
Construction/Loadline › Penetrations › Bottom Plug Packing
Issued 29 January 2003 Resolved
Thru hull fitting missing packing around wires fwd entrance to genarator room
Due 29 January 2003
Resolved 29 January 2003
Deck/Cargo
Issued 26 September 2000 Resolved
DREDGE CRANE INSPECTION OVERDUE.
Condition: Unknown
Due 10 October 2000
Resolved 18 October 2000
Unknown
Issued 26 July 1999 Resolved
UPON REQUEST FROM VESSEL OWNERS, CONDUCT A SATISFACTORY CERTIFICATE OF INSPECTION, AFTER SATISFACTORILY COMPLETING DRYDOCK INSPECTION, IN THE PRESENCE OF COAST GUARD MARINE INSPECTORS.
Condition: Unknown
Due 26 July 1999
Resolved 26 July 1999
Construction/Loadline
Issued 26 July 1999 Resolved
CONDUCT A SATISFACTORY DRYDOCK INSPECTION IN THE PRESENCE OF COAST GUARD MARINE INSPECTORS PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF INSPECTION.
Condition: Unknown
Due 26 July 1999
Resolved 26 July 1999
Documentation
Issued 26 July 1999 Resolved
UPON SATISFACTORY COMPLETION OF CERTIFICATE OF INSPECTION ENSURE VESSEL OWNERS PROVIDE PROOF OF USER FEE PAYMENT PRIOR TO ISSUING CERTIFICATE OF INSPECTION DOCUMENT.
Condition: Unknown
Due 26 July 1999
Resolved 26 July 1999
Lifesaving
Issued 6 May 1998 Resolved
REPLACE ALL SIX LIFE RING BOUYS WITH AN APPROVED TYPE, INTERNATIONAL ORANGEIN COLOR WITH RETROREFLECTIVE TAPE IN ACCORDANCE WITH 46 CFR 108.649.
Condition: Unknown
Due 19 May 1998
Resolved 19 May 1998
Lifesaving
Issued 6 May 1998 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 19 May 1998
Resolved 19 May 1998
Engineering
Issued 6 May 1998 Resolved
PROPERLY LABLE EMERGENCY FUEL SHUT OFF PULL CABLE.
Condition: Unknown
Due 19 May 1998
Resolved 19 May 1998
Unknown
Issued 6 May 1998 Resolved
REPLACE NON-METALLIC EXPANSION JOINTS IN THE PORT AND STARBOARD SPUD WINCH ROOM AND THE ENGINE ROOM (CTR) AT NEXT DRY DOCK.
Condition: Unknown
Due 6 May 1998
Resolved 6 May 1998
Engineering
Issued 6 May 1998 Resolved
PROPERLY LABLE PORT AND STARBOARD FUEL SHUT OFF VALVES ON MAIN DECK.
Condition: Unknown
Due 19 May 1998
Resolved 19 May 1998
Lifesaving
Issued 6 May 1998 Resolved
STOW WORK VESTS SEPARATELY FROM PFDs AND STENCIL STOWAGE AREA "WORK VESTS ONLY".
Condition: Unknown
Due 19 May 1998
Resolved 19 May 1998
Lifesaving
Issued 6 May 1998 Resolved
STENCIL ALL LIFE BOUY LOCATIONS "LIFE BOUY".
Condition: Unknown
Due 19 May 1998
Resolved 19 May 1998
Lifesaving
Issued 6 May 1998 Resolved
STENCIL ALL WORK VESTS "WORK VEST" IN ACCORDANCE WITH 46 CFR 108.636.
Condition: Unknown
Due 19 May 1998
Resolved 19 May 1998
Fire Fighting
Issued 6 May 1998 Resolved
REPLACE PORTABLE FIRE EXTINGUISHER ON O-2 LEVEL NEAR SPUD CONTROLS WITH APPROVED B-IIs.
Condition: Unknown
Due 19 May 1998
Resolved 19 May 1998
Engineering
Issued 6 May 1998 Resolved
PROVIDE SEVEN (7) MECHANICAL CLOSURES FOR THE COAMING IN WAY OF THE CRANE OPERATING AREA.
Condition: Unknown
Due 19 May 1998
Resolved 19 May 1998
Lifesaving
Issued 6 May 1998 Resolved
PROPERLY LABLE ESCAPE HATCHES LEADING FROM THE ENGINE ROOM.
Condition: Unknown
Due 19 May 1998
Resolved 19 May 1998
Fire Fighting
Issued 6 May 1998 Resolved
MAKE PERMANENT REPAIRS TO PIN HOLES IN FIRE MAIN DISCHARGE LINE.
Condition: Unknown
Due 19 May 1998
Resolved 19 May 1998
Fire Fighting
Issued 6 May 1998 Resolved
ADJUST FIRE EXTINGUISHER MOUNTING BRACKET TO FIT EXTINGUISHER.
Condition: Unknown
Due 19 May 1998
Resolved 19 May 1998
Documentation
Issued 30 June 1997 Resolved
PROVIDE PROOF OF A DRUG TESTING PROGRAM.
Condition: Unknown
Due 30 June 1997
Resolved 30 June 1997
Lifesaving
Issued 30 June 1997 Resolved
PROVIDE PERSON IN CHARGE LIST FOR TRANSFER PROCEDURES.
Condition: Unknown
Due 30 June 1997
Resolved 30 June 1997
Navigation
Issued 30 June 1997 Resolved
STRAIGHTEN PORT RUNNING LIGHT SUPPORT BRACKET.
Condition: Unknown
Due 30 June 1997
Resolved 30 June 1997
Fire Fighting
Issued 30 May 1995 Resolved
Demonstrate operation of number 1 fire pump.
Condition: Unknown
Due 3 August 1995
Resolved 3 August 1995
Documentation
Issued 30 May 1995 Resolved
Provide copy of Coast Guard approved shipboard oil pollution emergency plan(SOPEP) on board. Vessel is to provide surety bond or letter of undertakingfor $25,000 prior to departing the port of Miami.
Condition: Unknown
Due 30 June 1995
Resolved 20 October 1995
Electrical
Issued 30 May 1995 Resolved
Demonstrate operation of stand-by generator.
Condition: Unknown
Due 3 August 1995
Resolved 3 August 1995
Electrical
Issued 29 May 1992 Resolved
INSTALL EMERGENCY POWERED EMBARKATION LIGHTS FOR THE PORT AND STBD LIFERAFTS AND THE RESCUE BOAT._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 May 1992
Resolved 29 May 1992

Source. US Coast Guard records through 23 August 2026, retrieved 5 September 2026. Vessels the Coast Guard classes as Barge or Towing Vessel. Coverage and known gaps.

Maury does not score, rate, or grade vessels. What Maury does not do · Glossary · Correct a record.